Options
| Step
4 - Select Memory Options |
- Memory options are engineered specifically for use with this series and include
additional components, which are integral to the system architecture.
|
- Memory options consist of a series of base modules that contain one memory array. A
second array (called ?/font> upgrades?/font>
in the table) may be added to a base module in the factory or in the field.
|
|
0.5-GB GS80/160/320 base memory
module |
3X-MS8AA-AB |
|
0.5-GB GS80/160/320 memory DIMM
upgrade |
3X-MS8AA-AU |
|
1-GB GS80/160/320 base memory
module |
3X-MS8AA-BB |
|
1-GB GS80/160/320 memory DIMM
upgrade |
3X-MS8AA-BU |
|
2-GB GS80/160/320 base memory
module |
3X-MS8AA-CB |
|
2-GB GS80/160/320 memory DIMM
upgrade |
3X-MS8AA-CU |
|
4-GB GS80/160/320 base memory
module |
3X-MS8AA-DB |
|
4-GB GS80/160/320 memory DIMM
upgrade |
3X-MS8AA-DU |
| |
| Memory
Configuration Guidelines |
| Memory options should
be selected in the context of the application's sensitivity to memory bandwidth and memory
capacity, and the number of hardware partitions. This will determine the number of memory
base modules and upgrades needed. The total capacity required will determine the size of
the arrays to be chosen. |
The configuration of
memory may influence the performance of applications, and there are numerous ways to
configure the choices of memory base modules and upgrade DIMMs. The following general
guidelines can lead to several configuration choices. Application-specific guidelines will
help narrow down the choices.
- Configuring for capacity: The highest capacity is achieved when the 3X-MS8AA-DB/DU
combination is used.
- Configuring for performance: Interleaved operations reduce the average latency and
increase the memory throughput over non-interleaved operations. Each memory base module is
capable of 4-way interleaving with one array (no upgrades added) or 8-way interleaving
with two arrays (base module plus one upgrade). A system drawer is configured with eight
arrays (four base modules plus four array upgrades) provides 32-way interleaving and has
the maximum potential memory bandwidth. Refer to ?/font> Memory
Applications Examples?/font> below to determine which applications
gain the most benefit from this bandwidth.
- Memory modules should be configured in powers of 2: That is, 0, 1, 2, or 4 base modules
in a system drawer. Upgrades should also be installed in powers of 2: 0, 1, 2, or 4 base
modules in a system drawer.
- Although mixed-capacity memory modules may be configured, the highest bandwidth is
achieved when a system drawer is populated with eight identical arrays: four base modules
and four upgrades. The next-highest bandwidth would be four base modules (four arrays).
- If it is not possible to match the capacities of all the arrays, the next best choice is
to configure pairs of identical base modules, or base module/upgrade combinations. For
example, a configuration of two 2-GB base modules (3X-MS8AA-CB), each with a 1-GB upgrade
(3X-MS8AA-BU) is a better choice than a configuration of three 2-GB modules (3X-MS8AA-CB).
|
| |
| Memory Application
Examples |
Configuring memory is
a compromise between cost, total memory capacity, and memory bandwidth requirements. The
behavior of the application must be used to define the most-desired configuration. Some
applications are sensitive to memory capacity, some are sensitive to memory bandwidth,
some are sensitive to neither. If actual application measurements are not available, the
following may be used as guidelines:
- Large memory (VLM) applications, in which large amounts of memory can substantially
reduce I/O, may be optimized for total memory capacity and future capacity growth. In VLM
applications, the right balance might be one memory base module, with upgrade, for every
two CPUs. This would result in one memory array per CPU.
- Typical commercial applications, such as transaction processing (OLTP) and multi-user
timesharing, usually operate efficiently from cache and may not be materially affected by
memory bandwidth. Memory configuration is a balance between memory bandwidth and future
capacity growth. It is advisable to match the number of arrays to the number of CPUs.
- Data mining can benefit from additional memory bandwidth. It is best to match the number
of memory base modules to the number of CPUs.
- The most demanding high-performance technical applications (HPTC) achieve a performance
level that is directly proportional to memory bandwidth. In these cases, configure one
memory base module, with upgrade, per CPU. This results in two memory arrays per CPU.
The following table represents how 8 GB could be configured in a 4-CPU QBB system
drawer in each of the four referenced applications. The numbers under each application
represent how many of each memory option should be ordered. |
| |
| Memory Configuration Examples
Configuring a system drawer with a total of 8 GB for specific applications |
| |
Application |
| |
|
VLM |
OLTP, Timesharing |
Data Mining |
HPTC |
| 1-GB base module |
(3X-MS8AA-BB) |
- |
- |
- |
4 |
| 1-GB upgrade |
(3X-MS8AA-BU) |
- |
- |
- |
4 |
| 2-GB base module |
(3X-MS8AA-CB) |
2 |
2 |
4 |
- |
| 2-GB upgrade |
(3X-MS8AA-CU) |
2 |
2 |
- |
- |
| The following additional
configuration options utilizing the 4-GB base module are available: |
| 4-GB base module |
(3X-MS8AA-DB) |
2 |
2 |
N/R |
N/R |
| 4-GB upgrade |
(3X-MS8AA-DU) |
- |
- |
|
|
| NOTE: N/R
= Not recommended - For these applications, configure either
four or eight like-sized memory options rather than one or two. |
| |
| Step 5 - Evaluate
Configuration Requirements to Support Optional Partitioning |
| Configuration Requirements for Partitions |
- Configuring partitions requires some attention to detail with respect to minimum
requirements for option selection, population, and option placement.
|
- A single AlphaServer GS80 Model 8 can be divided into two logical hardware partitions,
each running an instance of Tru64 UNIX or an instance of OpenVMS. Each partition is
allocated its own dedicated ?/font> shared-nothing?/font> set of hardware resources: System Drawer (s), CPU module(s),
memory module(s), and I/O.
|
- Multiple-drawer (QBB) hard partitions within a GS80 server do not provide complete
hardware failure isolation across hard partitions. Single hard partitioned drawers (QBBs)
within the server do provide hardware failure isolation.
|
- Each hardware partition is viewed as a unique node, from a system point-of-view, with
its own instance of Tru64 UNIX or OpenVMS operating system and application software,
independent system console, and error log.
|
- In the AlphaServer GS80, each of the two hardware partitions is defined by a single
system drawer.
|
- One system management console (3X-DS8xA-xx) and one console hub (3X-DS8AA-AA)
recommended per system.
|
- Supported option rules apply for maximum configurations of each AlphaServer GS80 system
partition. Care must be exercised to ensure that any planned reconfiguration of hardware
partitions will not violate option support rules.
|
| |
| Minimum Hardware Required per AlphaServer
GS80 Hardware Partition |
| Each hardware partition requires one system
drawer and that drawer must be configured with the minimum hardware listed below. Each
system drawer can be configured with additional hardware once this minimum requirement is
met. |
- One Alpha 21264 6/1001-MHz CPU module
|
- One 3X-MS8AA-BB/CB/DB memory module (1 GB, 2 GB, 4 GB)
|
- One 3X-KFWHA-BA system I/O module and one 3X-DWWPA-AA master PCI drawer. Depending upon
the configuration, this may require the use of a 3X-H9A20-AD/AE/AF expansion cabinet.
|
- AlphaServer GS80 systems are normally configured according to standard module placement
rules, and are shipped with one copy of the operating system installed at the factory
(Tru64 UNIX or OpenVMS). However, systems with hardware partitions offer hardware and
software configuration flexibility. Factory Integration Services (VIS) are recommended to
enable custom module configuration and factory installation of multiple copies of the
operating system on hardware partitioned systems.
|
| |
| Optimizing System Resources |
| The following configuration guidelines can be
used to improve performance in systems or in each partition of a hardware-partitioned
system. |
- Balance the resources in the system (or hardware partition) based upon the available
backplane space and the proposed option populations:
- Sparsely configured systems, those that are using half or less than half of their
available capacity for CPUs, memory, and PCI drawers, should be configured with the
options concentrated in as few system drawers as possible. For example, a GS80 Model 8
with four CPUs, four memory modules, and two PCI drawers would usually be configured in
the first system drawer. The first system drawer would be ?/font>
active?/font> and the second system drawer would be available for
expansion.
- Densely populated systems, those that are using more than half of their available
capacity for CPUs, memory, and PCI drawers, should be configured with the options spread
out across both system drawers.
|
- Configure active system drawers symmetrically, each with CPUs, memory, and PCI drawers.
|
- Configure the I/O adapters so that each active system drawer has direct access to the
most frequently accessed data.
|
| |
| System Software Required for AlphaServer
GS80 Hardware Partition Support |
| Software Licensing for Hardware Partitions |
- Base systems include operating system license (Tru64 UNIX or OpenVMS) that licenses up
to two hardware partitions
|
| User and capacity-based licensing is
unaffected by hardware partitions. Examples: |
- If a product is licensed for 200 concurrent users, these users can be split among the
partitions, but cannot exceed 200 total users.
|
- If users have a departmental (license code ?/font> G?/font> ) capacity license for a product, that license can be loaded into
the license databases on each of the hardware partitions.
|
| |
| Licensing Partitioned AlphaServer GS80
Systems for Both OpenVMS and Tru64 UNIX |
- If the system requires both OpenVMS and Tru64 UNIX operating systems be licensed, one
operating system license is included in the base system and the second is added as a line
item. The second operating system license upgrade, which includes the license for only one
CPU, would be added to the order using the following part numbers. Order appropriate media
and documentation kits from Step 13.
|
|
OpenVMS software upgrade for GS80 |
QB-63PAG-AG |
|
Tru64 UNIX software upgrade for
GS80 |
QB-595AM-AA |
| |
- Only those SMP processors intended for use with the second operating system must be
similarly licensed. Use the following license-only part numbers to add an SMP license for
any CPUs intended for use with the second operating system:
|
|
OpenVMS Alpha SMP license for
GS80 |
QL-MT1A9-6Q |
|
Tru64 UNIX Alpha SMP license for
GS80 |
QL-MT4A9-6Q |
| |
- The order of licensing is not important, but the following examples are similarly
constructed for clarity: The configuration starts with a Tru64 UNIX base system part
number and the addition of OpenVMS licenses.
|
Example 1: 8-CPU GS80
system in which all processors are licensed for both OpenVMS and Tru64 UNIX:
- Base system order would include a DA-A80BE-Ax and seven 3X-KN8AB-AB SMP upgrade CPUs
- Add one QB-63PAG-AG OpenVMS software upgrade and seven QL-MT1A9-6Q OpenVMS Alpha SMP
licenses
|
| |
Example 2: 8-CPU GS80
system in which all the processors are licensed for Tru64 UNIX and four processors are
also licensed for OpenVMS
- Base system order would include a DA-A80AE-Ax and seven 3X-KN8AB-AB SMP upgrade CPUs
- Add one QB-63PAG-AG OpenVMS software upgrade and three QL-MT1A9-6Q OpenVMS Alpha SMP
licenses
|
- User and capacity-based licenses would be added for the second operating system
environment as though it were a standalone system.
|
| |
| Step
6 - Configure Packaging Options |
| Step
6a - Redundant (N+1) Power Supplies |
- Power supplies included with Model 4 and Model 8 systems can support all combinations of
CPUs, memory, and I/O that can be configured within the system boxes.
|
- Additional 48V power regulators can be ordered to provide N+1 power redundancy.
|
- For Model 4 systems, order one power supply to achieve N+1 capability; for Model 8
systems, order two power supplies to achieve N+1 capability.
|
|
1000 W 48V power
supply |
H7510-AA |
| |
| Step
6b - Internal System Expansion |
- AlphaServer GS80 Model 4 and Model 8 systems can support one additional PCI drawer
(master or expansion) or one BA36R or
DS-SL13R-xx StorageWorks?/font> shelf in the system
cabinet.
|
| |
| Internal
StorageWorks Expansion |
- System cabinet provides space for one forward facing StorageWorks shelf. There are two
configuration options:
- One BA36R-RC/RD StorageWorks shelf; shelf holds a maximum of two 5.25-inch devices and
one 3.5-inch device or seven 3.5-inch devices or
- One DS-SL13x-xx Ultra3 SCSI (LVD) shelf; shelf supports a maximum of 14 Ultra3 disk
drives
|
|
- Each UltraSCSI StorageWorks shelf requires a SCSI controller and a SCSI cable to connect
controller to shelf
|
|
|
- StorageWorks drives are listed in a subsequent section
|
|
| |
|
|
| Configuring BA36R StorageWorks
Shelf |
UltraSCSI single-channel SE
StorageWorks shelf includes 16-bit I/O personality module (DS-BA35X-FA), 180W ac power
supply, dc fans, and RETMA rackmounting hardware; supports 16-bit UltraSCSI devices and
some 8-bit narrow SCSI devices depending on compliance with minimum revision levels |
BA36R-RC |
|
UltraSCSI dual-channel SE
StorageWorks shelf, includes 16-bit I/O personality module
(DSBA35X-FB), 180W ac power supply, dc fans, and RETMA rackmounting hardware; supports
16-bit UltraSCSI devices and some 8-bit narrow SCSI devices depending on compliance with
minimum revision levels |
BA36R-RD |
|
UltraSCSI StorageWorks
Differential personality card; installs in BA36R-RC and is cabled to the KZPBA-CB or
3X-KZPBA-CC; field installed only |
DS-BA35X-DA |
| |
| Configuring DS-SL13R-xx Ultra3
(LVD) Shelf |
- Single-bus Ultra3 shelf requires a 3X-KZPCA-AA Ultra2 (LVD) SCSI adapter or
DS-KZPCC-xx RAID controller and a SCSI cable to connect controller to shelf
|
|
|
- Split-bus Ultra3 shelf requires two 3X-KZPCA-AA Ultra2 (LVD) SCSI adapters or
DS-KZPCC-xx RAID controllers and SCSI cables to connect controller to shelf
|
|
|
- Ultra3 shelves connected to 3X-KZPCA-AA adapters in the power cabinet require BN38C-02
2-meter cables; DS-KZPCC-xx RAID controllers require BN37A-02
2-meter cables.
|
|
|
- Ultra3 shelves connected to 3X-KZPCA-AA adapters in an attached expander cabinet require
BN38C-10 10-meter cables; DS-KZPCC-xx RAID controllers require BN37A-10 10-meter cables.
|
|
|
- Ultra3 shelves connected to 3X-KZPCA-AA adapters in a remote expander cabinet require 10
20-meter BN38C-xx cables, depending upon physical cabinet location;
DS-KZPCC-xx RAID controllers require BN37A-xx cables.
|
|
|
- Ultra3 Universal drives are listed in a subsequent section
|
|
|
StorageWorks Model
4314R Ultra3 SCSI (LVD) single-bus Universal drive rack-mount shelf, International except
Japan |
DS-SL13R-AA |
|
StorageWorks Model
4314R Ultra3 SCSI (LVD) single-bus Universal drive rack-mount shelf, Japan |
DS-SL13R-AJ |
|
StorageWorks Model
4354R Ultra3 SCSI (LVD) split-bus Universal drive rack-mount shelf, International except
Japan |
DS-SL13R-BA |
|
StorageWorks Model
4354R Ultra3 SCSI (LVD) split-bus Universal drive rack-mount shelf, Japan |
DS-SL13R-BJ |
| |
| Power Option for
BA36R Shelves |
- Additional power supply provides N+1 power for StorageWorks shelves; power supply uses
3.5-inch slot in StorageWorks shelf reducing total number of devices supported by one
|
|
- StorageWorks drives are listed in a subsequent section
|
|
|
180W redundant power supply for
StorageWorks shelf; includes power cord |
CK-BA35X-HH |
| |
|
|
| Power Option for DS-SL13R-xx
Shelves |
- Additional power supply provides N+1 power for 4314R Ultra3 (LVD) StorageWorks shelves;
power supply uses a dedicated location in the shelf.
|
|
|
- Not required for 4354R shelves.
|
|
|
Redundant power supply for 4314R
Ultra3 (LVD) StorageWorks shelf, North America |
DS-SE2UP-AA |
|
Redundant power supply for 4314R
Ultra3 (LVD) StorageWorks shelf, International |
DS-SE2UP-AI |
| |
|
|
| System I/O
Expansion |
- Model 4 systems support up to two PCI drawers; Model 8 systems support up to four PCI
drawers. One PCI drawer included in Model 4 and Model 8 base systems.
|
|
- Model 4 and Model 8 system cabinets provide space for one additional PCI drawer or one
internal storage shelf.
|
|
|
- Additional PCI drawers and storage shelves can be configured in 3X-H9A20-AD/AE/AF I/O
expansion cabinets, described in a subsequent section.
|
|
|
- All PCI drawers contain 14 PCI slots configured into four PCI buses; two of the buses
have four slots each, the other two buses have three slots each.
|
|
|
- There are two types of PCI drawers: expansion drawers and master drawers. Base system
configurations include one PCI master drawer with 12 configurable PCI slots.
|
|
|
- Expansion drawers contain 14 PCI slots and N+1 redundant power system; expansion drawers
are used for most PCI expansion applications.
|
|
|
- Optional master PCI drawers contain 13 configurable PCI slots, N+1 redundant power
system, plus the console ports and storage devices required for use as a system console.
(These devices are listed on page 2. Note that the Fast Ethernet adapter is not included
in optional master PCI drawers.) Optional master PCI drawers have two applications:
- As redundant console sub-systems
- As consoles for individual partitions in hardware partitioned systems
|
|
|
- PCI drawers are connected to a drawer utilizing a 3X-KFWHA-BA system I/O module that
connects to the PCI drawer using two BN39B cables.
|
|
| |
|
|
| PCI Drawer
Expansion |
- PCI drawers are connected to a drawer utilizing a 3X-KFWHA-BA system I/O module that
connects to the PCI drawer using two BN39B cables.
|
|
- Maximum one additional drawer in the system power cabinet see ?/font>
External Expansion Cabinets?/font> for more details.
|
|
|
- PCI drawers can be split between multiple system drawers as long as all system drawers
are contained within the same hardware partition.
|
|
|
- PCI drawers mounted in a common H9A20 Expansion Cabinet can server multiple systems.
|
|
|
Master PCI shelf mount box for
system and I/O expansion cabinets with standard I/O PCI module and 13 PCI expansion slots.
(The 1st master comes standard with all systems and includes a standard dual Ethernet
network card and the system module and cable pair for connection to the system drawer). |
3X-DWWPA-AA
|
|
Expansion PCI shelf mount box for
system and I/O expansion cabinets with 14 PCI expansion slots |
3X-DWWPA-BA |
|
System I/O module for connecting
to master or expansion PCI shelves |
3X-KFWHA-BA |
|
I/O module cable for connection
between I/O module and master or expansion PCI shelves is mounted in system cabinet; two
are mandatory per system I/O module |
BN39B-04
|
| |
|
|
| Step 6c - External Expansion Cabinets |
- Additional PCI drawers and storage shelves can be installed in an optional
3X-H9A20-AD/AE/AF expansion cabinet. One 3X-H9A20-AD/AE/AF expansion cabinet is supported
|
- The 3X-H9A20-AD/AE/AF I/O expansion cabinet can be configured to hold all disk BA36R
StorageWorks shelves or
DS-SL13R-xx Ultra3 StorageWorks shelves or combination of StorageWorks shelves and PCI
drawers.
- If no PCI drawers are configured, cabinet supports up to eight BA36R or five DS-SL13R-xx
StorageWorks shelves.
- If one PCI drawer is configured, cabinet supports up to five BA36R or four DS-SL13R-xx
StorageWorks shelves.
- If two PCI drawers are configured, cabinet supports up to four BA36R or three
DS-SL13R-xx StorageWorks shelves.
- If three PCI drawers are configured, cabinet supports up to two BA36R or two DS-SL13R-xx
StorageWorks shelves.
|
| |
- BA36R and DSSL13x-xx StorageWorks shelves can be combined in the same expansion cabinet,
but cannot be factory configured
|
|
Black I/O expansion cabinet for
use with GS80 systems, includes two 120V single-phase power controllers and cords for use
in US and Canada does not support dual AC input configurations |
3X-H9A20-AD |
|
Black I/O expansion cabinet for
use with GS80 systems, includes two 220-240V single-phase power controllers and cords for
use in Europe supports dual AC input configurations |
3X-H9A20-AE |
|
Black I/O expansion cabinet for
use with GS80 systems, includes two 200-240V single-phase power controllers and cords for
use in U.S., Canada, and Japan supports dual AC input configurations |
3X-H9A20-AF |
- If large quantities of disks are required, the use of StorageWorks Storage Array
cabinets and components is highly recommended.
|
- Systems installed in the US and Canada may use the 3X-H9A20-AD cabinet when 120V input
power is required. In all other cases, the 3X-H9A20-AF cabinet is preferred because of the
ability to support dual AC input.
|
- 3X-H9A20-AD/AE/AF cabinets may be joined to a GS80 system. PCI drawers placed in these
cabinets require 7-meter I/O cables.
|
- 3X-H9A20-AD/AE/AF cabinets may be placed up to 6 meters from the system cabinet.
Multiple expander cabinets may be connected to one another or placed separately. Each
group of free-standing H9A20 cabinets requires an end-panel trim kit (CK-H9A20-AB).
|
- PCI drawers placed in remote cabinets require 10-meter I/O cables.
|
|
Black end-panel trim kit for
remote 3X-H9A20-AD/AE/AF cabinets |
CK-H9A20-AB |
|
I/O module cables for connection
between I/O module and master or expansion PCI drawers mounted in 3X-H9A20-AD/AE/AF
expansion cabinet adjacent to system; two cables (BN39B-07 or BN39B-10) are mandatory per
PCI drawer. |
BN39B-07 |
|
I/O module cables for connection
between I/O module and master or expansion PCI drawers mounted in second expansion cabinet
or in remote 3X-H9A20-AD/AE/AF expansion cabinets; two cables (BN39B-07 or BN39B-10) are
mandatory per PCI drawer. |
BN39B-10 |
| |
| Step 7 - Storage |
| Step 7a - PCI UltraSCSI Adapters and Controllers |
- Tru64 UNIX can support more SCSI controllers per hardware partition than can be
configured in the AlphaServer GS80 system. Refer to the ?/font>
Supported Options List?/font> for specific rules.
|
- OpenVMS supports 24 KZPBA-CB/3X-KZPBA-CC SCSI controllers per system.
|
- Each master PCI drawer contains an embedded SCSI controllers that must be included in
the total count of SCSI controllers configured in the system (or partition). Tru64 UNIX
counts FIS disk and CD-ROM as an embedded SCSI device. OpenVMS counts the FIS disk only as
an embedded SCSI device. Therefore, one (OpenVMS) or two (Tru64 UNIX) SCSI controllers per
master PCI drawer must be included in the total count of SCSI devices in the system.
|
- For cluster configurations, use Y cable (BN39A-0G).
|
- Manufacturing may substitute correct cable lengths depending on configuration.
|
| NOTE: ?/font> Per System?/font> quantities apply to
systems or to each hardware partition. The SCSI adapters included in the base system or in
3x-DWWPA-AA master PCI drawers must be included in this calculation. |
| |
| |
Maximum #
Supported |
|
| |
Tru64 UNIX |
OpenVMS |
|
| |
Per System |
Per
System Drawer |
Per PCI Drawer |
Per
System |
Per
System Drawer |
Per PCI Drawer |
|
| PCI Fibre Channel adapter (uses
one PCI slot); requires Fibre Channel with SC connector for adapter |
26/54* |
26/26* |
13 |
26 |
26 |
13 |
DS-KGPSA-CA |
| 2-GB, PCI Fibre Channel adapter,
(uses one PCI slot); requires Fibre Channel cable with LC connector for adapter |
54 |
26 |
13 |
26 |
26 |
4 |
DS-KGPSA-DA |
Fibre Channel SC-SC cable
(BNGBX-xx),
xx=02, 03, 05, 10, 15, 30, 50 meters |
|
|
|
|
|
|
BNGBX-xx |
| Fibre Channel SC-LC cable,
2-meter (2976), 5-meter (2977), 15-meter (2978), 30-meter (3458), 50-meter (3459) |
|
|
|
|
|
|
3R-Axxxx-AA |
| Fibre Channel LC-LC cable,
2-meter (2979), 5-meter (2980), 15-meter (2981), 30-meter (3454), 50-meter (3455) |
|
|
|
|
|
|
3R-Axxxx-AA |
| |
| PCI 1-port UltraSCSI single-ended
host adapter (uses one PCI slot) |
8 |
8 |
8 |
8 |
8 |
8 |
KZPBA-CA |
| PCI 1-port UltraSCSI differential
host adapter (uses one PCI slot); requires BN38C-xx cable |
24/54* |
24/26* |
12/13* |
24 |
24 |
12 |
3X-KZPBA-CC |
VHDCI male-to-68-pin HD male
UltraSCSI cable xx=02, 05, 10, 20
(use -02 for connecting SCSI adapter to SCSI devices when both PCI shelf and StorageWorks
shelf are in system cabinet or in adjacent expansion cabinet; use -05, -10, and -20 for
connecting SCSI adapter to SCSI devices when the PCI shelf and StorageWorks shelf are in
two different cabinets) |
|
|
|
|
|
|
BN38C-xx |
| NOTE:
* = Tru64 UNIX V5.1 required to support 54 adapters per partition and 13 adapters
per PCI drawer. Tru64 UNIX 4.0G supports 24 adapters per partition |
| PCI 1-port Ultra 2 (LVD) SCSI
adapter, 32-bit, single-channel (uses one PCI slot); includes external 68-pin HD
connectors; requires BN38C-xx cable to connect adapter to Ultra2 or Ultra3 shelf; HSZxx
RAID controllers not supported |
8 |
8 |
8 |
8 |
8 |
8 |
3X-KZPCA-AA |
68-pin HD male-to-VHDCI male
UltraSCSI cable;
xx=02, 03, 05, 10, 20 meter |
|
|
|
|
|
|
BN38C-xx |
| |
| PCI 2-channel Ultra3 (LVD) SCSI
adapter, 64-bit/66-MHz (uses one PCI slot); includes internal 68-pin HD and external
68-pin VHDCI connectors; requires 3X-BC56J-xx cable to connect adapter to DS-SL13R-Bx/
DS-SSL14-xx Ultra3 shelf. NOTE:
OpenVMS 7.2-2, or later, is required; maximum cable length is 12 meters. |
- |
- |
- |
4 |
4 |
4 |
3X-KZPEA-DB |
68-pin VHDCI male-to-VHDCI male
UltraSCSI cable;
xx = 02, 03, 04, for 6, 12, and 24 meters respectively |
|
|
|
|
|
|
3X-BC56J-xx |
| |
| PCI 1-channel Ultra2 (LVD) SCSI
RAID controller, 16-MB cache, (uses one PCI slot); supports 14 disks per channel with
DS-SL13R-xx Ultra3 shelves; requires BN37A-xx cable to connect adapter to DS-SL13R-xx
Ultra3 shelf. |
8** |
8 |
8 |
- |
- |
- |
DS-KZPCC-AC |
| PCI 3-channel Ultra2 (LVD) SCSI
RAID controller, 64-MB cache, (uses one PCI slot); supports 14 disks per channel with
DS-SL13R-xx Ultra3 shelves; requires BN37A-xx cable to connect adapter to DS-SL13R-xx
Ultra3 shelf. |
8** |
8 |
8 |
- |
- |
- |
DS-KZPCC-CE |
68-pin VHDCI male-to-VHDCI male
UltraSCSI cable;
xx=02, 03, 05, 10, 20 meter |
|
|
|
|
|
|
BN37A-xx |
| NOTE:
** = Requires a Graphics Adapter or Graphical Display Station for its configuration
utility (other than the base system console). |
| |
NOTE:
- Use 2-meter cable to connect adapters, controllers, and shelf within the GS80 cabinet.
- Use 10-meter cable to connect adapters, controllers to shelves in attached H9A20
expander cabinets.
- Use 10-25-meter cables to connect adapters, controllers to shelves in remote expander
cabinets.
|
| |
|
|
| CI Adapters (OpenVMS only) |
PCI CI adapter, maximum 26 per
system or hardware partition (12 per drawer, six per PCI drawer); requires two PCI slots |
CIPCA-BA |
|
Computer interconnect cable set,
connects CIPCA to star coupler; select length xx=10, 20, 45 meters |
BNCIA-xx |
| |
| Step
7b - Internal Storage |
UltraSCSI Storage
Devices
(for use with BA356) |
9.1-GB 10,000 rpm 16-bit
UltraSCSI disk drive SBB |
DS-RZ1DD-VW |
| 18.2-GB 10,000 rpm 16-bit
UltraSCSI disk drive SBB |
DS-RZ1ED-VW |
|
36.4-GB 10,000 rpm 16-bit
UltraSCSI disk drive SBB |
DS-RZ1FC-VW |
| |
|
|
UltraSCSI Tape
Devices
(for use with BA356) |
12/24-GB 4 mm DAT SCSI tape drive
in 3.5-inch StorageWorks carrier |
DS-TLZ10-VA |
| 40/80-GB DLT SCSI tape drive in
5.25-inch StorageWorks carrier |
DS-TZ90N-VW |
| |
|
|
Ultra3 SCSI (LVD)
Storage Devices
(for use with DS-SL13R-xx) |
18.2-GB Ultra3 SCSI 10,000 rpm
Universal 1-inch disk drive |
3R-A0585-AA |
| 18.2-GB Ultra3 SCSI 15,000 rpm
Universal 1-inch disk drive |
3R-A1543-AA |
|
36.4-GB Ultra3 SCSI 10,000 rpm
Universal 1-inch disk drive |
3R-A0919-AA |
|
36.4-GB Ultra3 SCSI 15,000 rpm
Universal 1-inch disk drive |
3R-A3079-AA |
|
72.8-GB Ultra3 SCSI 10,000 rpm
Universal 1-inch disk drive |
3R-A3050-AA |
| |
|
|
Ultra2 SCSI (LVD)
Tape Devices
(for use with DS-SL13R-xx) |
AIT-351B, 35-GB tape drive
embedded in hot plug Universal carrier |
3R-A2396-AA |
| AIT-50, 50-GB tape drive embedded
in hot plug Universal carrier |
3R-A2779-AA |
|
SDT-10,000, 20/40-GB DAT tape
drive embedded in hot plug Universal carrier |
3R-A2780-AA |
| |
| Step 7c - Tape Devices |
| 3U Rackmount Tape Drive
Enclosure |
3U LVD Rackmount Tape Drive
Enclosure for use in H9Axx Series Cabinets, 0 drives, carbon black |
274338-B21 |
|
Rackmount kit for H9Axx Series
Cabinet, carbon black required for mounting 3U Rackmount Tape Drive Enclosure in
H9Axx cabinets |
3R-A3804-AA |
|
NOTE: The
3U Tape Drive Enclosure supports up to four internal half-height removable devices, or up
to two full height devices. Select up to four AIT or DAT devices, or two DLT/SDLT devices
with 3U Rackmount Tape Drive Enclosure (274338-B21), or select preconfigured
configurations listed below. |
|
| |
|
|
| Tape Drives for
Use in 3U Rackmount Tape Drive Enclosure |
AIT 35/70-GB 3U internal tape
drive, carbon black; requires 3X-KZPCA-AA LVD adapter |
216884-B21 |
| AIT 50/100-GB 3U internal tape
drive, carbon black; requires 3X-KZPCA-AA LVD adapter |
3R-A3753-AA
157766-B22 |
|
DAT 20/40-GB 3U internal tape
drive, carbon black; requires 3X-KZPCA-AA LVD adapter |
3R-A3752-AA
157769-B22 |
|
DLT8000 40/80-GB internal tape
drive, carbon black; requires 3X-KZPCA-AA LVD adapter |
146196-B22 |
|
SDLT 110/220-GB internal tape
drive, carbon black; requires 3X-KZPCA-AA LVD adapter |
192106-B25 |
|
SDLT 160/320-GB internal tape
drive, carbon black; requires 3X-KZPCA-AA LVD adapter |
257319-B21 |
| |
|
|
| Preconfigured
Configurations |
AIT 50-GB, 3U rackmount kit,
carbon black |
274333-B21 |
| DLT 40/80-GB, 3U rackmount kit,
carbon black |
274332-B21 |
|
DLT 40/80-GB, dual-drive, 3U
rackmount kit, carbon black |
274335-B21 |
|
SDLT 110/220-GB, single drive, 3U
rackmount kit, carbon black |
274331-B21 |
|
SDLT 110/220-GB, dual-drive, 3U
rackmount kit, carbon black |
274334-B21 |
| |
|
|
| 5U Rackmount Tape Drive
Enclosure |
5U LVD Rackmount Tape Drive
Enclosure, carbon black, or use in H9Axx Series Cabinet, 0 drives |
274339-B21 |
|
Rackmount Kit for H9Axx Series
Cabinet, carbon black required for mounting 5U Rackmount Tape Drive Enclosure in
H9Axx cabinets |
254795-001 |
|
NOTE: The
5U Rackmount Tape Drive Enclosure supports four full-height devices; select up to four DLT
or SDLT devices with 274339-B21, or select preconfigured configurations listed below. |
|
| |
|
|
| Tape Drives for
Use in 5U Tape Drive Enclosure |
DLT8000 40/80-GB tape drive,
requires 3X-KZPCA-AA LVD adapter, carbon black |
146196-B22 |
| SDLT 110/220-GB tape drive,
requires 3X-KZPCA-AA LVD adapter, carbon black |
192106-B25 |
|
SDLT 160/320-GB tape drive,
requires 3X-KZPCA-AA LVD adapter, carbon black |
257319-B21 |
| |
|
|
| Preconfigured Configurations |
SDLT 110/220-GB Tape Array III,
5U rackmount kit, carbon black |
274336-B21 |
|
DLT 40/80-GB Tape Array III, 5U
rackmount kit, carbon black |
274337-B21 |
|
DLT Tape Array III Model 0
enclosure, U.S. |
168047-001 |
|
Same as above, International |
168047-B31 |
|
Same as above, Japan |
168047-291 |
| |
|
|
| AIT Tabletop Tape Drives |
AIT 35/70-GB 8-mm LVD tabletop
tape drive, North America carbon black; requires LVD adapter |
216885-001 |
|
Same as above, International |
216885-B31 |
|
Same as above, Japan |
216885-291 |
|
AIT 50/100-GB 8-mm SCSI tabletop
tape drive with 120V North American power cord, carbon black; requires Ultra2 (LVD)
adapter |
157767-002 |
|
Same as above, International |
157767-B32 |
|
Same as above, Japan |
155767-292 |
| |
|
|
| AIT Hot-plug Tape Drives |
AIT 35/70-GB hot-plug LVD
Universal tape drive, uses two slots in 43xxx shelves |
3R-A2396-AA |
|
AIT 50/100-GB hot-plug LVD
Universal tape drive, uses two slots in or 43xxx shelves |
3R-A2779-AA |
| |
|
|
| AIT Autoloaders |
AIT 35-GB tabletop autoloader, 8
cartridge, U.S. |
292355-001 |
|
Same as above, International |
292355-B31 |
|
AIT 35-GB rackmount autoloader, 8
cartridge, U.S. |
280349-001 |
|
Same as above, International |
280349-B31 |
|
AIT Rail kit for rackmount
autoloader |
284930-001 |
| |
|
|
| AIT Tape Libraries |
SSL2020 AIT tabletop library with
one AIT 50-GB drive and 20 slots, LVD |
175195-B21 |
|
SSL2020 AIT tabletop library with
two AIT 50-GB drives and 20 slots, LVD |
175195-B22 |
|
SSL2020 AIT rackmount library
with one AIT 50-GB drive and 20 slots, LVD |
175196-B21 |
|
SSL2020 AIT rackmount library
with two AIT 50-GB drives and 20 slots, LVD |
175196-B22 |
| |
|
|
| DAT Tabletop Tape Drives |
DAT 12/24-GB 4-mm narrow
single-ended tabletop SCSI tape drive with 120V North American power cord; requires
BN31W-xx SCSI cable |
DS-TLZ10-DB |
|
DAT 20/40-GB 4-mm Wide Ultra2
(LVD) tabletop SCSI tape drive with 120V North American power cord, carbon black; requires
Ultra2 (LVD) adapter |
157770-002 |
|
Same as above, International |
157770-B32 |
|
Same as above, Japan |
157770-292 |
| |
|
|
| DAT Hot-plug Tape Drive |
DAT 20/40-GB DDS4 hot-plug LVD
Universal tape drive, uses two slots in 43xxx shelves |
3R-A2780-AA |
| |
|
|
| DAT Autoloaders |
DAT 20/40-GB auto loader
external; requires BN31W-xx SCSI cable and 3X-KZPCA-AA, or 3X-DEPVZ-AA adapter, North
America |
166505-001 |
|
Same as above, International |
166505-B31 |
|
Same as above, Japan |
166505-291 |
| |
|
|
| DLT/SDLT Tabletop Tape Drives |
DLT8000 tabletop 40/80-GB DLT
external tape drive, carbon black - requires 3X-KZPCA-AA LVD
adapter - U.S. |
146197-B23 |
|
Same as above Japan |
146197-292 |
|
SDLT tabletop 110/220-GB external
tape drive, carbon black- requires 3X-KZPCA-AA LVD adapter - U.S. |
192103-002 |
|
Same as above
International |
192103-B32 |
|
Same as above Japan |
192103-292 |
|
SDLT tabletop 160/320-GB external
tape drive, carbon black - requires 3X-KZPCA-AA LVD adapter - U.S. |
257319-001 |
|
Same as above -
International |
257319-B31 |
|
Same as above -
Japan |
257319-291 |
| |
|
|
| Library Rackmount Kit for
MSL5xxx Tape Libraries in H9Axx Cabinet Series |
Rackmount kit for H9Axx Series
cabinets required for mounting MSL5000 series in H9Axx cabinets |
254795-001 |
| |
|
|
| DLT/SDLT Tape
Libraries |
|
StorageWorks
MSL5026DLX DLT
40/80-GB Tape Library |
MSL5026DLX, DLT tabletop library
with one 40/80-GB DLT tape drive, LVD |
231821-B21 |
| MSL5026DLX, DLT tabletop library
with two 40/80-GB DLT tape drives, LVD |
231821-B22 |
|
MSL5026DLX or MSL5026SL, DLT/SDLT
rackmount library, 0 drives requires rackmount kit (254795-001) |
231979-B21 |
|
MSL5026DLX, DLT rackmount library
with one 40/80-GB DLT tape drive, LVD requires rackmount kit (254795-001) |
231891-B21 |
|
MSL5026DLX, DLT rackmount library
with two 40/80-GB DLT tape drives, LVD requires rackmount kit (254795-001) |
231891-B22 |
| |
|
|
| StorageWorks
MSL5026SL SDLT 110/220-GB Tape Library |
MSL5026SL, SDLT tabletop library
with one 110/220-GB SDLT tape drive, LVD; graphite |
302511-B21 |
| MSL5026SL, SDLT tabletop library
with two 110/220-GB SDLT tape drives, LVD; graphite |
302511-B22 |
|
MSL5026SL, SDLT rackmount library
with one 110/220-GB SDLT tape drive, LVD; graphite requires rackmount kit
(254795-001) |
302512-B21 |
|
MSL5026SL, SDLT rackmount library
with two 110/220-GB SDLT tape drives, LVD; graphite requires rackmount kit
(254795-001) |
302512-B22 |
| |
|
|
| StorageWorks
MSL5026S2 SDLT 160/320-GB Tape Library |
MSL5026S2, SDLT rackmount library
with 0 drives, LVD; graphite requires rackmount kit (254795-001) |
293472-B21 |
| MSL5026S2, SDLT rackmount library
with one 160/320-GB SDLT tape drive, LVD; graphite requires rackmount kit
(254795-001) |
293472-B22 |
|
MSL5026S2, SDLT rackmount library
with one 160/320-GB SDLT tape drive, LVD; graphite requires rackmount kit
(254795-001) |
293472-B23 |
|
MSL5026S2, SDLT rackmount library
with one 160/320-GB SDLT tape drive, Fibre Channel Interface; graphite requires
rackmount kit (254795-001) |
293472-B24 |
|
MSL5026S2, SDLT rackmount library
with two 160/320-GB SDLT tape drives, Fibre Channel Interface; graphite requires
rackmount kit (254795-001) |
293472-B25 |
|
MSL5026S2, SDLT tabletop library
with one 160/320-GB SDLT tape drive, LVD; graphite |
293473-B21 |
|
MSL5026S2, SDLT tabletop library
with two 160/320-GB SDLT tape drives, LVD; graphite |
293473-B21 |
|
MSL5000 SDLT2 upgrade drive, all |
293475-B21 |
| |
|
|
| StorageWorks
MSL5052SL SDLT 110/220-GB Tape Library |
MSL5052, 0 drives, LVD, rackmount |
255102-B21 |
| MSL5052SL SDLT tabletop library
with two 110/220-GB tape drives, LVD |
249490-B21 |
|
MSL5052SL SDLT rackmount library
with two 110/220-GB tape drives, LVD requires rackmount kit (254795-001) |
249491-B21 |
|
MSL5052SL SDLT 110/220-GB drive
field upgrade, LVD |
231823-B22 |
| |
|
|
| StorageWorks MSL5052S2 SDLT
160/320-GB Tape Library |
MSL5052S2, SDLT rackmount library
with two 160/320-GB SDLT tape drives, LVD; graphite requires rackmount kit
(254795-001) |
293474-B21 |
|
MSL5052S2, SDLT rackmount library
with two 160/320-GB SDLT tape drives, Fibre Channel Interface; graphite requires
rackmount kit (254795-001) |
293474-B24 |
|
MSL5052S2, SDLT tabletop library
with two 160/320-GB SDLT tape drives, LVD; graphite |
293476-B21 |
| |
|
|
| StorageWorks ESL9322S2 SDLT
160/320-GB Tape Library |
ESL9322S2 SDLT tape library, with
two 160/320-GB SDLT tape drives, 222 slots - requires
3X-KZPCA-AA adapter |
293409-B22 |
|
ESL9322S2 SDLT tape library, with
eight 160/320-GB SDLT tape drives, 222 slots - requires
3X-KZPCA-AA adapter |
293409-B28 |
|
ESL9322S2 SDLT tape library, with
two 160/320-GB SDLT tape drives, 322 slots - requires
3X-KZPCA-AA adapter |
293410-B22 |
|
ESL9322S2 SDLT tape library, with
eight 160/320-GB SDLT tape drives, 322 slots - requires
3X-KZPCA-AA adapter |
293410-B28 |
|
ESL9000 SDLT2 LVD upgrade drive |
293414-B21 |
| |
|
|
| StorageWorks
ESL9595SL SDLT 110/220-GB Tape Library |
ESL9595SL SDLT tape library, 0
drives, 400 slots - requires 3X-KZPCA-AA adapter |
274672-B21 |
ESL9595SL SDLT tape library, two
110/220-GB SDLT tape drives, 400 slots - requires
3X-KZPCA-AA adapter |
274672-B22 |
|
ESL9595SL SDLT tape library with
16 110/220-GB SDLT tape drives, 400 slots - requires
3X-KZPCA-AA adapter |
274672-B28 |
|
ESL9595SL SDLT tape library with
0 drives, 500 slots - requires 3X-KZPCA-AA adapter |
281627-B21 |
|
ESL9595SL SDLT tape library with
two 110/220-GB SDLT tape drives, 500 slots - requires
3X-KZPCA-AA adapter |
281627-B22 |
|
ESL9595SL SDLT tape library with
16 110/220-GB SDLT tape drives, 500 slots - requires
3X-KZPCA-AA adapter |
281627-B28 |
|
ESL9595SL SDLT tape library, 0
drives, 595 slots - requires 3X-KZPCA-AA adapter |
281628-B21 |
|
ESL9595SL SDLT tape library with
two 110/220-GB SDLT tape drives, 595 slots - requires
3X-KZPCA-AA adapter |
281628-B22 |
|
ESL9595SL SDLT tape library with
16 drives 110/220-GB SDLT tape drives, 595 slots - requires
3X-KZPCA-AA adapter |
281628-B28 |
| |
|
|
| StorageWorks ESL9595S2 SDLT
160/320-GB Tape Library |
ESL9595S2 SDLT2 tape library, two
160/320-GB tape drives, 400 slots - requires
3X-KZPCA-AA adapter |
293411-B22 |
|
ESL9595S2 SDLT2 tape library with
16 160/320-GB tape drives, 400 slots - requires
3X-KZPCA-AA adapter |
293411-B28 |
|
ESL9595S2 SDLT2 tape library with
two 160/320-GB tape drives, 500 slots - requires 3X-KZPCA-AA
adapter |
293412-B22 |
|
ESL9595S2 SDLT2 tape library with
16 160/320-GB tape drives, 500 slots - requires
3X-KZPCA-AA adapter |
293412-B28 |
|
ESL9595S2 SDLT2 tape library with
two 160/320-GB tape drives, 595 slots - requires 3X-KZPCA-AA
adapter |
293413-B22 |
|
ESL9595S2 SDLT2 tape library with
16 160/320-GB tape drives, 595 slots - requires
3X-KZPCA-AA adapter |
293413-B28 |
|
ESL9000 SDLT2 LVD upgrade drive |
293414-B21 |
| |
|
|
| StorageWorks
ESL9198SL SDLT 110/220-GB Tape Library |
ESL9198SL SDLT tape library with
four 110/220-GB SDLT tape drives, 198 slots; requires 3X-KZPCA-AA adapter |
234618-B21 |
| ESL9198SL SDLT tape library with
eight 110/220-GB SDLT tape drives, 198 slots; requires 3X-KZPCA-AA adapter |
234618-B22 |
| |
|
|
| Compatible Storage Devices |
The following tape drives are
compatible with the AlphaServer GS80: |
|
|
- TZ88, TSZ07, TLZ09, TKZ62, TKZ63, TKZ90, TLZ9L, TL800, TL891, TL892, TL890, TL893,
TL894, TL895, TL896, DS-TLZ10-VA, TSZ20, TSZ08, DLT7000, AIT35, TZ89N
|
|
| |
| Step 7d
External Storage |
| External Storage Arrays |
- ESA 12000 Storage Arrays and RAID Array 8000 (HSG80/HSZ80 product set) are supported on
Tru64 UNIX and OpenVMS systems.
|
- ESA 10000 Storage is supported on Tru64 UNIX and OpenVMS systems.
|
- SW800 CI Storage Arrays (HSJ5x product set) are supported on OpenVMS systems.
|
| NOTE: This web site is available in English
only.
|
| |
| Storage Array Controllers |
| The following controllers are
used in StorageWorks array packaging: |
| HSZ80 RAID Controllers |
- HSZ80 UltraSCSI RAID controllers for RA8000 and ESA12000 are supported under Tru64 UNIX
and OpenVMS.
|
|
|
- HSZ80 UltraSCSI RAID controllers require platform kit 400569-001 for Tru64 UNIX or
400571-001 for OpenVMS. PCMCIA software kit, 400566-001/QB-678AA-SA, also required for
each controller.
|
|
|
- HSZ80 UltraSCSI controllers require KZPBA-CB/3X-KZPBA-CC adapters and BN38C cables (and
UltraSCSI hubs if used).
|
|
|
NOTE:
For system integration of the following options, contact CustomSystems. |
|
DS-HSZ80-AH UltraSCSI controller,
includes 64-MB cache expandable to128 MB |
400564-B21 |
|
DS-HSZ80-AJ UltraSCSI controller,
includes 256-MB cache expandable to 512 MB |
400565-B21 |
|
64-MB cache upgrade for HSx80
(DS-HSDIM-AB) |
380673-B21 |
|
256-MB cache upgrade for HSx80
(DS-HSDIM-AC) |
380674-B21 |
| |
|
|
| HSG80 Fibre Channel
Controllers |
- HSG80 Fibre Channel controllers for RA8000, MA8000, ESA12000, EMA12000 are supported
under Tru64 UNIX and OpenVMS.
|
|
|
- HSG80 Fibre Channel controllers require platform kit 380553-001/QB-65RAB-SA for Tru64
UNIX or 380555-001/QB-65RAC-SA for OpenVMS. Software kit, 128697-B21 HSG80 ACS V8.4F or
128698-B21 V8.4P, also required for each HSG80 ordered.
|
|
|
- HSG80 Fibre Channel controllers require DS-KGPSA-CA or DS-KGPSA-DA Fibre Channel
adapters, BNGBX cables, and fiber hubs or switches (see Fiber Hubs, Switches, and
Components)
|
|
|
NOTE:
For system integration of the following options, contact CustomSystems. |
|
DS-HSG80-BH Fibre Channel
controller, includes 64-MB cache expandable to 128 MB |
380671-B21 |
|
DS-HSG80-BJ Fibre Channel
controller, includes 256-MB cache expandable to 512 MB |
380672-B21 |
|
64-MB cache upgrade for HSx80
(DS-HSDIM-AB) |
380673-B21 |
|
256-MB cache upgrade for HSx80
(DS-HSDIM-AC) |
380674-B21 |
| |
|
|
| HSV110 Enterprise
Virtual Storage Array Fibre Channel Controllers |
- HSV110 Enterprise Virtual Storage Array Fibre Channel Controllers are supported with a
minimum of Tru64 UNIX V5.1 at this time only
|
|
- HSV110 Storage Controllers require a platform kit for Tru64 UNIX V5.1 - 250193-B21, SAN VCS Controller Software kit -
250203-B22 also required for each controller pair
|
|
|
NOTE:
For system integration of the following options, contact CustomSystems. |
|
DS-SV110-AA EVA 12000 42U (2C +
6D), 60 HZ |
234345-B21 |
|
DS-SV110-AB EVA 12000 42U (2C +
6D), 50 HZ |
234345-B22 |
|
DS-SV110-BA EVA 12000 42U (2C +
12D), 60 HZ |
234346-B21 |
|
DS-SV110-BB EVA 12000 42U (2C +
12D), 50 HZ |
234346-B22 |
|
DS-SV110-EA EVA 12000 42U (8C +
8D), 60 HZ |
239782-001 |
|
DS-SV110-EB EVA 12000 42U (8C +
8D), 50 HZ |
249977-B21 |
| |
|
|
| HSJ54 CI Storage Array
Controller |
- HSJ54 CI Storage Array controllers are supported under OpenVMS V7.2-1H1 with CIPCA-BA CI
controllers; QB-5C4AA-SA software kits required for each external cache (one for HSJ50,
two for HSJ52, four for HSJ54).
|
|
|
- HSJ54 CI Storage Array controllers require star couplers (SC008-AB, -AC or -AD) with
CIPCA-BA adapters and BNCIA cables.
|
|
|
- Controllers require KZPBA or CIPCA SCSI adapters or controllers, as appropriate.
|
|
|
NOTE:
For system integration of the following option, contact CustomSystems. |
|
Quad 512-MB cache CI array
controller with cache batteries |
HSJ54-AJ |
| |
|
|
| UltraSCSI Hubs |
- UltraSCSI hubs are supported with KZPBA-CB/3X-KZPBA-CC PCI differential SCSI adapters.
|
|
|
UltraSCSI hub with three
differential ports, no single-ended ports, consists of two host ports and one storage port
in 3.5-inch SBB, UltraSCSI cables not included |
DS-DWZZH-03 |
|
UltraSCSI hub with five
differential ports, no single ended ports, consists of four host ports and one storage
port in 5.25-inch SBB, UltraSCSI cables not included |
DS-DWZZH-05 |
| |
|
|
| Step 7e
Fibre Channel Options |
| Fibre Channel
Hubs, Switches, and Components |
NOTE: For
system integration of the following options, contact CustomSystems. |
|
| Fibre Channel SAN Switch, 8
ports, 2 Gb, with Fabric Operating Software |
258707-B21
DS-DSGGD-AC |
|
Fibre Channel SAN Switch, 16
ports, 2 Gb with Fabric Operating Software |
283056-B21
DS-DSGGD-AD |
|
Fibre Channel SAN Switch, 16
ports, 2 Gb with Fabric Operating Software, two power supplies |
287055-B21
DS-DSGGD-BA |
|
Unmanaged Fibre Channel 7-port
Storage Hub, North America (Tru64 UNIX only) |
234453-001
DS-SWXHB-07 |
|
Fibre Channel 7-port Storage Hub,
International (Tru64 UNIX only) |
234453-B31
DS-SWXHB-17 |
|
Fibre Channel 7-port Storage Hub,
Japan (Tru64 UNIX only) |
234453-291
DS-SWXHB-J7 |
|
Fibre Channel 7-port hub,
Universal mount kit |
136127-B21
DS-SWXHX-07 |
|
Long wave GBIC |
127508-B21
DS-DSGGA-MA |
|
Short wave optical GBIC |
380561-B21
DS-DSGGA-SA |
|
Fibre Channel 3 GBIC connection
kit |
380579-B21
DS-DXGK1-SA |
|
Fibre Channel 2 GBIC connection
kit |
380596-B21
DS-DXGK2-SA |
|
1 Fibre Channel x 2 HVD data
router |
163082-B21
3R-A2673-AA |
|
1 Fibre Channel x 2 LVD data
router |
163083-B21
3R-A2774-AA |
|
2 x 4 LVD Fiber Channel-to-SCSI
Network Storage Router |
262653-B21
3R-A3740-AA |
| 2 x 4 HVD Fiber Channel-to-SCSI
Network Storage Router |
262654-B21
3R-A3741-AA |
| |
|
|
| McData 64-port
Fibre Channel SAN Director Class Switch |
SAN Director 64 (1 Gb) 32 ports,
base model |
DS-DMGGD-AA |
| SAN Director Connectivity Manager
Kit |
DS-DMGGO-AA |
| SAN Director 2 Gb, 64 ports |
DS-DMGGD-BA |
|
SAN Edge Switch 2 Gb, 32 ports |
DS-DMGGE-BC |
|
SAN Edge Switch 2 Gb, 16-ports |
DS-DMGGE-BB |
|
SAN Director 64 Long-wave 4-port
module kit |
DS-DMGGD-AC |
|
SAN Director 64 Short-wave 4-port
module kit |
DS-DMGGD-AD |
|
SAN Director 64 Combo, Long
1 port/Short 3 ports - Wave Module Kit |
DS-DMGGD-AE |
| |
| Step 8 -
Networks and Communications |
- One Fast Ethernet adapter included in base systems. Connection of system to Ethernet
requires twisted-pair cable.
|
| |
| PCI LAN Communications
Controllers |
- Requires 3X-DWWPA-AA /BA PCI shelf mount box
|
- Each adapter/controller uses one PCI slot
|
- A maximum of 16 network adapters - 3X-DE602-xx, DEGPA-xx,
3X-DEFPA-xx - are supported per system or hardware partition.
|
| |
| NOTE: ?/font>Per System?/font> quantities apply to systems
or to each hardware partition. The 3X-DE602-xx included in base system must be included in
these calculations. Operating System limitations may further limit the maximum number of
configurable options. |
|
| |
Maximum #
Supported |
|
| |
Tru64 UNIX |
OpenVMS |
|
| |
Per System |
Per
System Drawer |
Per PCI Drawer |
Per System |
Per
System Drawer |
Per PCI Drawer |
|
| 10/100-Mbit Fast
Ethernet Adapter |
| PCI Dual-port 10/100 UTP Fast
Ethernet adapter and base module |
8 |
8 |
8 |
8 |
8 |
8 |
3X-DE602-AA
|
| Single-port multi-mode fiber
(MMF) add-on daughter card |
8 |
8 |
8 |
8 |
8 |
8 |
3X-DE602-FA |
Category 5 cross-over cable for
point-to-point, unshielded
xx=01, 03, 04, 07, 0E for 1, 3, 4, 7, 0.5 meters |
|
|
|
|
|
|
BN24Q-xx |
Category 5 cross-over cable for
point-to-point, shielded
xx=01, 03, 04, 07, 0E for 1, 3, 4, 7, 0.5 meters |
|
|
|
|
|
|
BN28Q-xx |
| Category 5 straight through for
system to repeater or hub, unshielded, xx=01, 03, 04, 07, 0E, 0B for 1, 3, 4, 7, 0.5, 0.2
meters |
|
|
|
|
|
|
BN25G-xx |
Twisted pair, shielded cable,
xx=01, 03, 04, 07, 0E for 1, 3, 4, 7, 0.5 meters |
|
|
|
|
|
|
BN26M-xx |
| |
| FDDI Controllers |
| PCI FDDIcontroller, fiber,
single-attachment station multimode fiber, requires BN34x SC type connecting cable |
8 |
8 |
8 |
8 |
8 |
8 |
3X-DEFPA-AC |
| PCI FDDIcontroller, fiber,
dual-attachment station multimode fiber, requires BN34x SC type connecting cable |
8 |
8 |
8 |
8 |
8 |
8 |
3X-DEFPA-DC |
Multimode fiber optic duplex
cable, SC connector-to-ST connector,
xx=01, 03, 10, 20, 30, 2E, 4E for 01, 03, 10, 20, 30, 2.5, 4.5 meters |
|
|
|
|
|
|
BN34A-xx |
Multimode fiber optic duplex
cable, SC connector-to-SC connector,
xx=01, 03, 10, 20, 30, 2E, 4E for 01, 03, 10, 20, 30, 2.5, 4.5 meters |
|
|
|
|
|
|
BN34B-xx |
Multimode fiber optic duplex
cable, SC connector-to-MIC connector,
xx=01, 03, 10 for 01, 03, 10 meters |
|
|
|
|
|
|
BN34D-xx |
PCI FDDIcontroller, copper,
dual-attachment station UTP, requires
BN26x or BN25H connecting cables |
8 |
8 |
8 |
8 |
8 |
8 |
3X-DEFPA-MC |
PCI FDDIcontroller, copper,
single-attachment station UTP, requires
BN26x or BN25H connecting cables |
8 |
8 |
8 |
8 |
8 |
8 |
3X-DEFPA-UC |
| 8-pin MP-to-8-pin MP, screened,
EIA/TIA category 5 cable |
|
|
|
|
|
|
BN26M-xx |
8-pin MP-to-8-pin MP, screened,
crossover, EIA/TIA category 5 cable,
3 meters |
|
|
|
|
|
|
BN26S-03 |
| 3-meter unshielded twisted pair
RJ45 connectors |
|
|
|
|
|
|
BN25H-03 |
| |
| Gigabit Ethernet
Adapter |
| For maximum
performance, Compaq recommends configuring two DEGPA-SA adapters (or less) per PCI drawer,
however, eight adapters per PCI drawer may be configured to achieve maximum connectivity. |
| PCI Gigabit Ethernet adapter,
does not support network boot (BN34B) |
8/16* |
8/16* |
8 |
16 |
16 |
8 |
DEGPA-SA |
| PCI-to-Gigabit
Ethernet UTP adapter (32-/64-bit) does not support network boot uses BN 24Q, BN28Q, BN25Q,
BN26M cables |
4 |
4 |
4 |
4 |
4 |
4 |
DEGPA-TA |
Multimode fiber optic
duplex cable, SC connector-to-SC connector,
xx=01, 03, 10, 20, 30, 2E, 4E for 01, 03, 10, 20, 30, 2.5, 4.5 meters |
|
|
|
|
|
|
BN34B-xx |
Category 5 cross-over
cable for point-to-point, unshielded
xx=01, 03, 04, 07, 0E for 1, 3, 4, 7, 0.5 meters |
|
|
|
|
|
|
BN24Q-xx |
Category 5 cross-over
cable for point-to-point, shielded
xx=01, 03, 04, 07, 0E for 1, 3, 4, 7, 0.5 meters |
|
|
|
|
|
|
BN28Q-xx |
| Category 5 straight
through for system to repeater or hub, unshielded, xx=01, 03, 04, 07, 0E, 0B for 1, 3, 4,
7, 0.5, 0.2 meters |
|
|
|
|
|
|
BN25G-xx |
Twisted pair,
shielded cable,
xx=01, 03, 04, 07, 0E for 1, 3, 4, 7, 0.5 meters |
|
|
|
|
|
|
BN26M-xx |
| |
|
|
|
|
|
|
|
| NOTE: * = Tru64 UNIX V5.1 is required to support 16 adapters per
System/Drawer. Tru64 UNIX 4.0G supports 8 adapters per system/drawer. |
| |
| ATM Adapters |
| For maximum
performance, Compaq recommends configuring four 3X-DAPCA-FA adapters (or less) per PCI
drawer; however, eight adapters per PCI drawer may be configured to achieve maximum
connectivity. |
| PCI-to-ATMworks 155-Mbit adapter,
fiber, uses BN34B cable |
8 |
8 |
8 |
8 |
8 |
8 |
3X-DAPBA-FA |
| PCI-to-ATMworks 155-Mbit adapter,
UTP, uses BN25G and BN26M cables |
8 |
8 |
8 |
8 |
8 |
8 |
3X-DAPBA-UA |
| PCI-to-ATMworks 622-Mbit adapter,
fiber, uses BN34B cable |
8 |
8 |
8 |
8 |
8 |
8 |
3X-DAPCA-FA |
Multimode fiber optic duplex
cable, SC connector-to-SC connector,
xx=01, 03, 10, 20, 30, 2E, 4E for 01, 03, 10, 20, 30, 2.5, 4.5 meters |
|
|
|
|
|
|
BN34B-xx |
| Category 5 straight through for
system to repeater or hub, unshielded, xx=01, 03, 04, 07, 0E, 0B for 1, 3, 4, 7, 0.5, 0.2
meters |
|
|
|
|
|
|
BN25G-xx |
Category 5 straight through for
system to repeater of hub, shielded
xx=01, 03, 04, 07, 0E for 1, 3, 4, 7, 0.5 meters |
|
|
|
|
|
|
BN26M-xx |
| |
| Synchronous
Controllers |
| PCI 2-port intelligent
synchronous controller (OpenVMS/Tru64 UNIX systems require a WAN/X.25 Kit. Refer to the
latest option QuickSpecs for further information |
4 |
4 |
4 |
10 |
10 |
10 |
3X-PBXDD-AA |
| PCI 4-port intelligent
synchronous controller (OpenVMS/Tru64 UNIX systems require a WAN/X.25 Kit. Refer to the
latest option QuickSpecs for further information. |
4 |
4 |
4 |
10 |
10 |
10 |
3X-PBXDD-AB |
| DataFire SYNC 2000 EIA-530
single-port cable |
|
|
|
|
|
|
3X-BC34G-06 |
| DataFire SYNC 2000 V.11/x.21
single-port cable |
|
|
|
|
|
|
3X-BC34S-06 |
| DataFire SYNC 2000 V.35
single-port cable |
|
|
|
|
|
|
3X-BC34T-06 |
| DataFire SYNC 2000 V.24/EIA232
single-port cable |
|
|
|
|
|
|
3X-BC34L-06 |
- Up to two PCI System Area Network controllers supported on a GS80e partition
|
- Two-node clusters can be configured by ordering a CCMAB-AA for each node and one
BN39B-04 or BN39B-10 cable; cable connects directly to CCMAB-AA in each node.
|
- For a two-node cluster that will not be rebooted when adding additional members, order
one CCMAB-AA adapter and one BN39B-04 or BN39B-10 cable for each node, and one CCMHB-AA
hub for the cluster.
|
- For three or four node clusters, order one CCMAB-AA adapter and one BN39B-04 or BN39B-10
cable for each node and one CCMHB-AA hub for the cluster
|
- CCMHB-AA includes four CCMLB-AA line cards and supports up to four nodes; expansion up
to eight system nodes can be achieved by adding up to four additional CCMLB-AA line cards
|
- If two or more CCMAB-AA controllers are configured in each node (dual rail), a second
CCMHB-AA hub is required
|
- If using a MEMORY CHANNEL adapter module (54-24962-01) prior to revision D02, up to two
MEMORY CHANNEL adapters can be placed on a PCI bus, however, no additional PCI devices can
be placed on the same PCI bus, and the remaining slots must be left empty
|
| |
| Tru64 UNIX Systems (V5.1
and later) in Clusters using MEMORY CHANNEL Interconnect |
- Each system in the cluster requires a TruCluster Server software license
(QL-6BRAG-AA)
- Alternately a TruCluster Plus Software package including licenses for: TruCluster
Server, Logical Storage Manager, and AdvFS Utilities can be ordered
(QP-6R9AG-AA)
|
|
| |
|
|
| OpenVMS Systems in Clusters
using MEMORY CHANNEL Interconnect |
- Requires OpenVMS V7.2-1H1 or later and OpenVMS Cluster license
(QL-MUZAG-AA)
|
|
| |
|
|
| MEMORY CHANNEL Fiber Optic
Cable Option |
- In cases where nodes must be separated by a longer distance than standard copper cables
allow, the CCMFB option converts the output of the standard CCMAB controller or CCMLB line
card to single-mode fiber optic cable. The fiber optic connection may be up to 2,000
meters long between two CCMAB controllers connected in virtual hub mode, or 3,000 meters
between a CCMAB controller and a CCMHB hub. (The connection from the CCMHB hub to a second
system may also be 3,000 meters). The CCMFB option requires a second PCI slot in the
system from which it draws power only. It is normally connected to the corresponding CCMAB
controller with the short BN39B-01 cable. The CCMFB is also used in the CCMHB hub where it
occupies a slot normally used by the CCMLB line card, limiting expansion to four radial
fiber optic connections.
|
|
|
- The CCMHB-BA hub expansion box provides additional slots for up to eight fiber optic
connections. Two standard length, single-mode fiber optic cables are available (BN34R-10
and BN34R-31); however, users normally provide this connection. Customers should reference
the TIA/EIA 568-A Commercial Building Telecommunications Cabling Standard, Section 12.3.4.
Fiber optic connectivity is completely transparent to the systems using it and has no
performance impact.
|
|
|
- Up to two CCMHB-AA hubs may be mounted in a 3X-H9A20-AD expansion cabinet by utilizing a
2T-MAVRK-AA rack-mounting kit for each hub. A second MEMORY CHANNEL Hub (CCMHB-AA or
CCMHM-BA) mounted in an expansion cabinet reduces the amount of StorageWorks shelves by
one.
|
|
| |
|
|
| MEMORY CHANNEL Controller |
PCI System Area Network
controller, maximum two per system, two per node |
CCMAB-AA |
|
System Area Network hub with four
line cards; includes BN19P-2E power cord for Canada, Japan, and U.S. operations;
country-specific power cord for other regions is required |
CCMHB-AA |
|
MEMORY CHANNEL hub expansion box
with no line cards |
CCMHB-BA |
|
MEMORY CHANNEL hub rack-mounting
kit |
2T-MAVRK-AA |
|
Expansion line card for CCMHB hub |
CCMLB-AA |
|
1-meter cable for CCMAB and CCMHB |
BN39B-01 |
|
4-meter cable for CCMAB and CCMHB |
BN39B-04 |
|
10-meter cable for CCMAB and
CCMHB |
BN39B-10 |
|
Copper-to-single mode fiber optic
converter |
CCMFB-AA |
| |
|
|
| Country-specific
Power Cords for Standalone MEMORY CHANNEL Hubs |
Australia, New Zealand |
BN19H-2E |
| Central Europe |
BN19C-2E |
| Denmark |
BN19K-2E |
|
Egypt, India |
BN19S-2E |
|
Ireland, United Kingdom |
BN19A-2E |
|
Israel |
BN18L-2E |
|
Italy |
BN35M-02 |
|
Japan |
3X-BN46F-02 |
|
Switzerland |
BN19E-2E |
| |
|
|
| Power Cord for
MEMORY CHANNEL Hubs Rackmounted in 3X-H9A20-AE/AF Cabinets |
IEC 320 power cord (one mandatory
per hub) |
BN35S-02 |
| NOTE:
MEMORY CHANNEL hubs mounted in 3X-H9A20-AD cabinets do not require additional power cords. |
| |
|
|
| Step
10 - System Console Support |
| System Management Console |
- AlphaServer GS80 systems require the ability to log console messages, provide remote
access for service and support, and, in some cases, manage multiple hardware partitions.
The system management console is mandatory if the customer has no other means to provide
these capabilities.
|
|
|
- PC-based system management console is required for system power-up, diagnostics, console
partitioning, and console display and logging for use with AlphaServer GS80 systems.
|
|
|
- Includes network interface cards, universal modem, Compaq console software, 101-key
keyboard, mouse, and console documentation kit
|
|
|
- A monitor is required for use with the system management console. Choose monitor listed
in Step 12.
|
|
|
- Systems configured with redundant consoles or employing hardware partitioning require
the ability to connect multiple consoles. A console hub is mandatory if the customer has
no other means to provide these capabilities.
|
|
|
- Console printer recommended, but not required.
|
|
|
PC-based Windows NT?/font> system management console in tower package, includes network
interface cards and console software (Last Shipment date June 30, 2002) |
3X-DS8BA-AA |
|
PC-based Windows 2000 system
management console in tower package, includes network interface cards and console software |
3X-DS8DA-AA |
|
PC-based Windows NT system
management console in mini-tower package, includes network interface cards and console
software, Europe (Last Shipment date June 30, 2002) |
3X-DS8BA-AB |
|
PC-based Windows 2000 system
management console in mini-tower package, includes network interface cards and console
software, Europe |
3X-DS8DA-AB |
|
PC-based Wiindows NT system
management console in desktop package, includes network interface cards and console
software, U.S./Canada/Japan (Last Shipment date June 30, 2002) |
3X-DS8BA-BA |
|
PC-based Windows 2000 system
management console in desktop package, includes network interface cards and console
software, U.S./Canada/Japan |
3X-DS8DA-BA |
|
PC-based Windows NT system
management console in desktop package, includes network interface cards and Compaq console
software, Europe (Last Shipment date June 30, 2002) |
3X-DS8BA-BB |
|
PC-based Windows 2000 system
management console in desktop package, includes network interface cards and console
software, Europe |
3X-DS8DA-BB |
|
Console hub for use with system
management console, includes console concentrator, cables, and universal power supply;
mounts in system cabinet and communicates with the system management console over Ethernet
using the Telnet protocol. |
3X-DS8AA-AA |
| |
|
|
| System Management Console - ConsoleWorks Upgrade Licenses |
- System management console includes ConsoleWorks, which supports up to eight partitions
on a single system
|
|
|
- Support for additional GS Series partitions on a second GS system require the purchase
of an add-on license for two, four, or eight partitions on that system
|
|
|
- Use of a single console for management of multiple GS systems requires use of a multiple
port Ethernet Hub such as HP Procurve Series
|
|
|
AlphaServer GS System Management,
2 Partitions ConsoleWorks License from TECSys Development LP |
QM-6K4AA-AB |
|
AlphaServer GS System Management,
4 Partitions ConsoleWorks License from TECSys Development LP |
QM-6K4AA-AC |
|
AlphaServer GS System Management,
8 Partitions ConsoleWorks License from TECSys Development LP |
QM-6K4AA-AD |
| |
|
|
| System Management
Console - Modem Localization Kits |
System management consoles
include one adapter kit |
|
- 3X-DS8BA-AA/BA includes a localization kit for use in U.S., Canada, Japan, Mexico,
Brazil, Argentina, Peru, and Taiwan
|
|
|
- 3X-DS8BA-AB/BB includes a localization kit for use in Great Britain, Ireland, Hong Kong,
Singapore, and Malaysia
|
|
|
In all other cases, the
appropriate localization kit is required: |
|
|
Australia |
3R-A1608-AA |
|
Austria |
3R-A1607-AA |
|
Belgium |
3R-A1609-AA |
|
China |
3R-A1594-AA |
|
Denmark |
3R-A1596-AA |
|
Finland, Norway |
3R-A1597-AA |
|
France |
3R-A1598-AA |
|
Germany |
3R-A1595-AA |
|
Greece |
3R-A1606-AA |
|
India |
3R-A1600-AA |
|
Italy |
3R-A1601-AA |
|
Netherlands |
3R-A1602-AA |
|
New Zealand |
3R-A1603-AA |
|
Sweden, Iceland |
3R-A1604-AA |
|
Switzerland |
3R-A1610-AA |
| |
|
|
| System Management Console - Country-specific Power Cords |
- System management console includes a line cord for use in North America. Order a
country-specific line cord if required.
|
|
|
Australia, New Zealand |
BN19H-2E |
|
Central Europe |
BN19C-2E |
|
Denmark |
BN19K-2E |
|
Egypt, India |
BN19S-2E |
|
Ireland, United Kingdom |
BN19A-2E |
|
Israel |
BN18L-2E |
|
Italy |
BN35M-02 |
|
Japan |
3X-BN46F-02 |
|
North America |
BN26J-1K |
|
Switzerland |
BN19E-2E |
| |
|
|
| Step
11 - Graphics Support |
|
- Graphics support for an AlphaServer GS80 can be provided through use of a graphics
adapter
|
|
|
3D Labs Oxygen VX1 32-MB PCI
graphics card, maximum one per system or hardware partition |
SN-PBXGF-AB |
| |
|
|
| Step 12 - Monitors,
Keyboards, Mouse |
- Graphics monitors other than those listed below can be used if compatible with SVGA
graphics ordered with system.
|
- Selection of video extension cable and country-specific power cord is mandatory for all
monitors; order power cord as appropriate.
|
- Add or order appropriate keyboard and mouse
|
- Monitors will ship with, but not be integrated with systems.
|
| |
| Keyboard or Mouse Extension
Cable |
6-foot/1.8-meter keyboard or
mouse extension cable (order two cables to extend both keyboard and mouse) |
3X-BC34A-06 |
| |
|
|
| Video Extension Cable |
6-foot/1.8-meter video extension
cable |
BN39C-02 |
| |
|
|
| Mouse |
3-button mouse carbon |
3R-A3480-AA |
| |
|
|
| Carbon/Silver Monitors |
P720 17-inch (16-inch viewable
image size) auto-scanning color monitor, Diamondtron NF, 0.25mm aperture grille pitch, VGA
to 1280 x 1024 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA
power cord, VGA cable |
3R-A3388-AA/244373-001 |
|
Same as above, with Euro-power
cord |
3R-A3389-AA/244373-021 |
|
Same as above, APD, no power cord |
3R-A3390-AA/244373-B24 |
|
Same as above, PRC, with power
cord, CCIB |
3R-A3391-AA/244373-AA1 |
|
Same as above, Southern
Hemisphere, with Australia/New Zealand power cord |
3R-A3392-AA/244373-011 |
|
|
|
|
P920 19-inch (18-inch viewable
image size) auto-scanning color monitor, Diamondtron NF, 0.24mm aperture grille pitch, VGA
to 1600 x 1200 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA
power cord, VGA cable |
3R-A3393-AA/244375-001 |
|
Same as above, with Euro power
cord |
3R-A3394-AA/244375-021 |
|
Same as above, PRC with power
cord, CCIB |
3R-A3396-AA/244375-AA1 |
|
Same as above, Southern
Hemisphere, 0.25 to 0.27 mm aperture grille pitch, with Australia/New Zealand power cord |
3R-A3397-AA/244375-011 |
|
|
|
|
P1220 22-inch (20-inch viewable
image size) auto-scanning color monitor, Diamondtron NF, 0.24mm aperture grille pitch, VGA
to 1792 x 1344 @85Hz, dual video input, USB Hub, MPRII/TCO 99/Energy Star Compliant,
Northern Hemisphere with NA power cord, VGA cable |
3R-A3398-AA/244374-001 |
|
Same as above, with Euro power
cord |
3R-A3399-AA/244374-021 |
|
Same as above, APD, no power cord |
3R-A3400-AA/244374-B24 |
|
Same as above, PRC, with power
cord, CCIB |
3R-A3401-AA/244374-AA1 |
|
Same as above, Southern
Hemisphere, with Australia/New Zealand power cord |
3R-A3402-AA/244374-011 |
| |
|
|
| Carbon/Silver Flat Panel
Monitors |
TFT8030, 18.1-inch (18-inch
viewable image size) TFT flat panel monitor, 0.28mm pixel pitch, 1280 x 1024 @75 Hz,
multi-mode support, MPRII/TCO99/Energy Star compliant, six video input connectors (two
VGA, two DVI-I, one S-video, and one C-video), NA power cord, VGA and DVI-I cables |
3R-A3511-AA/234362-001 |
|
TFT5030, 15.1-inch (15-inch
viewable image size) TFT flat panel monitor, 0.30mm pixel pitch, 1024 x 768 @75 Hz,
multi-mode support, MPRII/TCO99/Energy Star compliant, two video input connectors (one VGA
and one DVI-I), NA power cord, VGA and DVI-I cables |
3R-A3353-AA/228134-001 |
| |
|
|
| Monitor Power Cords |
Australia, New Zealand |
BN19H-2E |
|
Central Europe |
BN19C-2E |
|
Denmark |
BN19K-2E |
|
Egypt, India |
BN19S-2E |
|
Ireland, United Kingdom |
BN19A-2E |
|
Israel |
BN18L-2E |
|
Italy |
BN35M-02 |
|
Japan |
3X-BN46F-02 |
|
North America |
BN26J-1K |
|
Switzerland |
BN19E-2E |
| |
|
|
| Keyboards |
- Select a keyboard and mouse
- Select an opal OpenVMS keyboard for use with VT5xx text terminals.
- All keyboards listed may not be available in all geographies
|
|
| |
|
|
| |
Opal |
Carbon |
| Keyboard/Language |
OpenVMS |
Tru64 UNIX |
OpenVMS |
| U.S./English keyboard |
LK461-A2 |
3R-LKQ48-AA |
3X-LK462-A2 |
| Arabic keyboard |
- |
3R-LKQ48-BR |
- |
| Belgian keyboard |
LK461-AB |
3R-LKQ48-AB |
3X-LK462-AB |
| BHCSY keyboard |
- |
3R-LKQ48-AX |
- |
| Canadian/English keyboard |
LK461-AQ |
- |
3X-LK462-AQ |
| Canadian/French keyboard |
LK461-AC |
3R-LKQ48-AC |
3X-LK462-AC |
| Cyrillic keyboard (Russian) |
LK461-BT |
3R-LKQ48-BT |
3X-LK462-BT |
| Czech keyboard |
LK461-BV |
3R-LKQ48-BV |
3X-LK462-BV |
| Danish keyboard |
LK461-AD |
3R-LKQ48-AD |
3X-LK462-AD |
| Dutch keyboard |
LK461-AH |
3R-LKQ48-AH |
3X-LK462-AH |
| Finnish keyboard |
LK461-AF |
3R-LKQ48-AF |
3X-LK462-AF |
| French keyboard |
LK461-AP |
3R-LKQ48-AP |
3X-LK462-AP |
| German keyboard |
LK461-AG |
3R-LKQ48-AG |
3X-LK462-AG |
| Greek keyboard |
LK461-BH |
3R-LKQ48-BH |
3X-LK462-BH |
| Hebrew keyboard |
LK461-AT |
3R-LKQ48-AT |
3X-LK462-AT |
| Hungarian keyboard |
LK461-BQ |
3R-LKQ48-BQ |
3X-LK462-BQ |
| International keyboard |
- |
3R-LKQ48-BA |
- |
| Italian keyboard |
LK461-AI |
3R-LKQ48-AI |
3X-LK462-AI |
| Japanese keyboard |
- |
3R-LKQ48-AJ |
- |
| Korean keyboard |
- |
3R-LKQ48-BK |
- |
| Latin-American keyboard |
- |
3R-LKQ48-AR |
- |
| Norwegian keyboard |
LK461-AN |
3R-LKQ48-AN |
3X-LK462-AN |
| Polish keyboard |
LK461-BP |
3R-LKQ48-BP |
3X-LK462-BP |
| Portuguese keyboard |
LK461-AV |
3R-LKQ48-AV |
3X-LK462-AV |
| Romanian keyboard |
LK461-BL |
- |
3X-LK462-BL |
| Simplified Chinese keyboard |
- |
3R-LKQ48-CV |
- |
| Slovak keyboard |
LK461-CZ |
3R-LKQ48-CZ |
3X-LK462-CZ |
| Spanish keyboard |
LK461-AS |
3R-LKQ48-AS |
3X-LK462-AS |
| Swedish keyboard |
LK461-AM |
3R-LKQ48-AM |
3X-LK462-AM |
| Swiss/French keyboard |
LK461-AK |
3R-LKQ48-AK |
3X-LK462-AK |
| Swiss/German keyboard |
LK461-AL |
- |
3X-LK462-AL |
| Traditional Chinese keyboard |
- |
3R-LKQ48-BI |
- |
| Thai keyboard |
- |
3R-LKQ48-CB |
- |
| Turkish Q keyboard |
LK461-BU |
3R-LKQ48-BU |
3X-LK462-BU |
| Turkish/F keyboard |
LK461-BW |
- |
3X-LK462-BW |
| UK keyboard |
- |
3R-LKQ48-AE |
- |
| Yugoslavian keyboard |
LK461-BY |
- |
3X-LK462-BY |
| |
| Step 13 - System
Software |
- Media and documentation required for first system on site
|
- Software Processor Code = G
|
| |
| Tru64 UNIX |
- Tru64 UNIX base systems include pre-installed software, Base license, Unlimited User
license, Server Extension license, Internet Express, and iPlanet Web Server Enterprise
Edition 4.0
|
|
| |
|
|
| When
using Tru64 UNIX V5.1 or later |
Tru64 UNIX media and online
documentation on CD-ROM |
QA-6ADAA-H8 |
| Tru64 UNIX full hard copy
documentation |
QA-6ADAA-GZ |
|
TruCluster Plus Software Package
with licenses for TruCluster Server, Logical Storage Manager, and AdvFS Utilities |
QP-6R9AG-AA
|
|
TruCluster Server license |
QL-6BRAG-AA |
|
Logical Storage Manager License |
QL-2GVAG-AA |
|
AdvFS Utilities License |
QL-0EGAG-AA |
|
Advanced Server for Tru64 UNIX,
25 client concurrent use license |
QL-5U29M-3D |
|
Advanced Server for Tru64 UNIX,
50 client concurrent use license |
QL-5U29M-3E |
|
Advanced Server for Tru64 UNIX,
100 client concurrent use license |
QL-5U29M-3F |
|
Advanced Server for Tru64 UNIX,
250 client concurrent use license |
QL-5U29M-3G |
|
Advanced Server for Tru64 UNIX,
500 client concurrent use license |
QL-5U29M-3H |
|
Layered products media and
documentation for Tru64 UNIX on CD-ROM |
QA-054AA-H8 |
|
DECnet/OSI end-system license for
Tru64 UNIX |
QL-MTJAG-AA |
|
DECnet/OSI extended function
license for Tru64 UNIX |
QL-MTKAG-AA |
| |
|
|
| When using Tru64
UNIX V4.0G |
Tru64 UNIX media and online
documentation on CD-ROM |
QA-MT4AA-H8 |
|
Tru64 UNIX full hard copy
documentation |
QA-MT4AA-GZ |
|
StorageWorks software package
with licenses for Logical Storage Manager and AdvFS Utilities |
QB-5RXAG-AA |
|
TruCluster Available Server
license |
QL-05SAG-AA |
|
TruCluster Production Server
license |
QB-3RLAG-AA |
|
Tru64 UNIX Driver for MEMORY
CHANNEL license |
QB-4ZCAG-AA |
|
Advanced Server for Tru64 UNIX,
25 Client Concurrent License |
QL-5U29M-3D |
|
Advanced Server for Tru64 UNIX,
50 Client Concurrent License |
QL-5U29M-3E |
|
Advanced Server for Tru64 UNIX,
100 Client Concurrent License |
QL-5U29M-3F |
|
Advanced Server for Tru64 UNIX,
250 Client Concurrent License |
QL-5U29M-3G |
|
Advanced Server for Tru64 UNIX,
500 Client Concurrent License |
QL-5U29M-3H |
|
Layered products media and
documentation for Tru64 UNIX on CD-ROM |
QA-054AA-H8 |
|
DECnet/OSI end-system license |
QL-MTJAG-AA |
|
DECnet/OSI extended function
license |
QL-MTKAG-AA |
| |
|
|
| OpenVMS |
- OpenVMS system base packages include Base license and Compaq Enterprise Integration
Server for OpenVMS License Package Revision V3.0A
|
|
|
- OpenVMS Concurrent Use licenses provide the right to interactively use the operating
system by the specified number of concurrent users on a designated OpenVMS system. OpenVMS
Concurrent Use licenses can be moved from one system to another at user discretion and can
be shared in a mixed OpenVMS VAX and OpenVMS Alpha cluster.
|
|
|
Concurrent Use 1-user license |
QL-MT3AA-3B |
|
Concurrent Use 2-user license |
QL-MT3AA-3C |
|
Concurrent Use 4-user license |
QL-MT3AA-3D |
|
Concurrent Use 8-user license |
QL-MT3AA-3E |
|
Concurrent Use 16-user license |
QL-MT3AA-3F |
|
Concurrent Use 32-user license |
QL-MT3AA-3G |
|
Concurrent Use 64-user license |
QL-MT3AA-3H |
|
Concurrent Use 128-user license |
QL-MT3AA-3J |
|
Concurrent Use 256-user license |
QL-MT3AA-3K |
|
Traditional unlimited-user
license |
QL-MT2AG-AA |
|
OpenVMS V7.2-1H1 media and online
documentation on CD-ROM |
QA-MT1AU-H8 |
|
OpenVMS media and documentation
on CD-ROM |
QA-MT1AA-H8 |
|
OpenVMS base hard copy
documentation |
QA-09SAA-GZ |
|
Layered products media and
documentation for OpenVMS on CD-ROM; includes Compaq Enterprise Integration Server for
OpenVMS media and documentation |
QA-03XAA-H8 |
|
DECnet/OSI end-system license |
QL-MTFAG-AA |
|
DECnet/OSI extended-function
license |
QL-MTHAG-AA |
|
Cluster License for OpenVMS Alpha |
QL-MUZAG-AA |
| |
|
|
| OpenVMS
Galaxy OpenVMS Galaxy Licensing Requirements |
For more details about OpenVMS
Galaxy licensing requirements, refer to the Software Product Description for the Galaxy
Software Architecture on OpenVMS Alpha: SPD 70.44.xx OpenVMS Update 05 is required.
|
|
- One OpenVMS Base Operating System License (included in base system) is mandatory for
AlphaServer GS80 configured as an OpenVMS Galaxy system.
|
|
|
- One SMP Extension License (included in SMP CPU upgrade) is mandatory for each CPU after
the first CPU.
|
|
|
- For each AlphaServer GS80 CPU in an OpenVMS Galaxy, one OpenVMS Galaxy License is
mandatory.
|
|
|
- Compaq layered products are licensed as follows:
- One capacity license per system
- One user license per use
|
|
|
- Up to two instances of OpenVMS are supported in OpenVMS Galaxy configurations on
AlphaServer GS80 systems.
|
|
|
For more information about
OpenVMS Galaxy requirements, configurations, and procedures, refer to the OpenVMS Alpha
Galaxy Guide. The latest version is always available at http://www.openvms.compaq.com/gsseries/index.html
NOTE: This web site is available
in English only. |
|
|
Galaxy 1-CPU License |
QL-66XAA-3B |
|
Galaxy 2-CPU License |
QL-66XAA-3C |
|
Galaxy 4-CPU License |
QL-66XAA-3D |
|
Galaxy 8-CPU License |
QL-66XAA-3E |
|
- Example: 8 CPU GS80 system in which all processors are licensed for OpenVMS with two
hard partitions (each with four CPUs) and all CPUs licensed for Galaxy:
|
|
- Base system order would include a DY-A80BE-Ax and seven 3X-KN8AB-AC SMP upgrade CPUs
|
|
- Add one QL-66XAA-3E Galaxy 8-CPU License
|
|
|
- No other licenses are required for OpenVMS on the SMP instance in the second hard
partition with four CPUs.
|
|
| |
|
|
| Step
14 - Hardware and Software Support Services |
|
- Installation or Installation and Startup is required for all AlphaServer GS80 systems.
|
|
|
- Select one of the optional CarePaq Priority Service Packages described below that best
supports the customers operational requirements for system availability.
|
|
| |
|
|
| CarePaq Priority
Services |
- CarePaq Priority Services are available for AlphaServer systems running Tru64 UNIX or
OpenVMS operating systems. Priority Services are designed for the growing number of
customers who need support beyond the basic warranty. Five packages are offered -
Priority, Priority 24, Priority Silver, Priority Gold, and Priority Executive with
coverage for both Principal servers systems and SSPs (Subsequent System Packages) - that meet a full range of customer support requirements.
|
|
| |
|
|
| Program Features
Principal Server |
|
| Priority |
|
|
|
- 4-hour response on-site hardware support
|
|
|
- 2-hour response for Bronze software support
|
|
|
- License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
|
|
- Condist update distribution for OpenVMS or Tru64 UNIX and their layered products.
(Layered products not included on Condist can be ordered separately.)
|
|
| |
|
|
| Priority 24 |
|
|
|
|
|
|
- 4-hour response on-site hardware support
|
|
|
- 2-hour response for Bronze software support
|
|
|
- License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
|
|
- Condist update distribution for OpenVMS or Tru64 UNIX and their layered products.
(Layered products not included on Condist can be ordered separately.)
|
|
| |
|
|
| Priority Silver |
- 24 x 7 HW Support. Named Engineer, 4-hour response
|
|
|
- 24 x 7 Silver SW Support - Named Account Rep, 1-hour response Monday Friday,
8AM-5PM local time; 2-hour response remaining hours
|
|
|
- License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
|
|
- Condist update distribution for OpenVMS or Tru64 UNIX and their layered products.
(Layered products not included on Condist can be ordered separately.)
|
|
|
- Technical newsletter and SW activity review
|
|
|
- Proactive Patch Notification
|
|
|
- One (1) System Healthcheck per year
|
|
| |
|
|
| Priority Gold |
- 24 x 7 HW support with Named Engineer, 4-hour response for on-site support
|
|
- 24 x 7 Gold SW support - Named Account Rep
|
|
|
- 30-minute callback (critical); 1-hour callback (non-critical)
|
|
|
- License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
|
|
- Condist update distribution for OpenVMS or Tru64 UNIX and their layered products.
(Layered products not included on Condist can be ordered separately.)
|
|
|
- Technical newsletter, SW activity review and 10 hours Upgrade impact planning
|
|
|
- Proactive Revision Management
|
|
|
- Two (2) System Healthchecks per year
|
|
|
- Mandatory pre-qualification required
|
|
| |
|
|
| Priority Gold
Executive |
- 24 x 7 HW support with Named Engineer, two-hour response for on-site support
|
|
|
- 24 x 7 Gold SW support - Named Account Rep
|
|
|
- 30-minute callback (critical); one-hour callback (non-critical)
|
|
|
- License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
|
|
- Software update distribution on CD-ROM: OpenVMS or Tru64 UNIX and their layered products
(Layered products not included on Condist can be ordered separately.)
|
|
|
- Technical newsletter, SW activity review and 10 hours Upgrade impact planning
|
|
|
- Proactive Revision Management
|
|
|
- Two (2) System Healthchecks per year
|
|
|
- Customer site must be within 25 miles of a Compaq service location
|
|
|
- Mandatory pre-qualification required
|
|
| |
|
|
| SSPs (Subsequent
System Packages) |
- For Priority, Priority 24, Priority Silver, Priority Gold, and Priority Gold Executive
|
|
- HW Support at same level as corresponding package for Principal server
|
|
|
- License Subscription: Compaq O/S (where applicable)
|
|
|
- Telephone support through Principal server covered by full support package
|
|
| |
|
|
| Installation |
|
|
|
|
|
|
|
|
|
|
|
|
- No software installation added
|
|
| |
|
|
| Installation
& Startup Compaq O/S |
|
|
|
|
|
|
|
|
|
|
|
|
- Install operating systems
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
Model/CarePaq
Priority Service |
Principal
Server
1 year |
Principal
Server
3 years |
Subsequent
Systems
1 year |
Subsequent
Systems
3 years |
| AlphaServer
GS80 Model 4 |
|
|
|
| Priority |
FP-W0101-12 |
FP-W0101-36 |
FP-W2101-12 |
FP-W2101-36 |
| Priority 24 |
FP-W0201-12 |
FP-W0201-36 |
FP-W2201-12 |
FP-W2201-36 |
| Priority Silver |
FP-W0401-12 |
FP-W0401-36 |
FP-W2401-12 |
FP-W2401-36 |
| Priority Gold |
FP-W0801-12 |
FP-W0801-36 |
FP-W2801-12 |
FP-W2801-36 |
| Priority Gold Exec. |
FP-W0901-12 |
FP-W0901-36 |
FP-W2901-12 |
FP-W2901-36 |
| Installation |
FP-WINST-80 |
FP-WINST-80 |
FP-WINST-80 |
FP-WINST-80 |
| Installation &
Startup |
FP-WSTAR-80 |
FP-WSTAR-80 |
FP-WSTAR-80 |
FP-WSTAR-80 |
| AlphaServer
GS80 Model 8 |
|
|
|
| Priority |
FP-W0102-12 |
FP-W0102-36 |
FP-W2102-12 |
FP-W2102-36 |
| Priority 24 |
FP-W0202-12 |
FP-W0202-36 |
FP-W2202-12 |
FP-W2202-36 |
| Priority Silver |
FP-W0402-12 |
FP-W0402-36 |
FP-W2402-12 |
FP-W2402-36 |
| Priority Gold |
FP-W0802-12 |
FP-W0802-36 |
FP-W2802-12 |
FP-W2802-36 |
| Priority Gold Exec. |
FP-W0902-12 |
FP-W0902-36 |
FP-W2902-12 |
FP-W2902-36 |
| Installation |
FP-WINST-80 |
FP-WINST-80 |
FP-WINST-80 |
FP-WINST-80 |
| Installation &
Startup |
FP-WSTAR-80 |
FP-WSTAR-80 |
FP-WSTAR-80 |
FP-WSTAR-80 |
| |
NOTES:
- AlphaServer GS80 systems include one-year hardware warranty with 5x9, on-site Next
Business Day response.
- New Compaq hardware options internal to the AlphaServer enclosure receive the same
warranty or service level as purchased with the server.
- External storage devices/cabinets carry their own level of warranty and should be quoted
separately for uplifted warranty services.
- In addition to the CarePaq Priority Services, uplifted warranty CarePaq Supplemental
Services are available for separate hardware and software support. For more information on
Hardware and Software Supplemental Services and other service options available for
AlphaServers, consult your Sales Account Manager or visit
http://www.compaq.com/services/
NOTE: This web site is available in English only. |
| |
| Software -
Americas and Asia Pacific Only |
- Systems include 90-day Conformance to SPD and Telephone Advisory Support. Select
optional Software Supplemental Support Services if required.
|
|
|
- Software service upgrades for Tru64 UNIX include advisory and remedial software support
with new version license rights for Tru64 UNIX Base, unlimited users, and Server
Extensions
|
|
|
- Software service upgrades for OpenVMS include advisory and remedial software support
with new version license rights for OpenVMS Base and Enterprise Integration Package
|
|
| |
|
|
| Recommended Quickstart
Services |
AlphaServer GS80 Quickstart
Service - This service allows customers to quickly
configure and setup their systems for optimal performance and best use of system
management and system maintenance features. This 40-hour service will: |
|
|
- Evaluate their requirements and current systems/applications environment
|
|
|
- Plan the server partitioning, storage layout, installation, and migration of the new
system
|
|
|
- Perform installation and setup
|
|
|
- Provide initial system performance tuning
|
|
|
- Provide training in the use of the System Control Manager
|
|
|
GS80/160 Quickstart Evaluate and
Plan |
QS-GS1A9-CP |
| |
|
|
| Recommended Factory
Integration Services |
Value-added Implementation
Services (VIS) provide systems integration and delivery services. VIS services, including
system integration, extended burn-in, custom documentation, and on-site services can be
custom-quoted for the full range of AlphaServer configurations.
These pre-packaged services are offered for systems shipped to North America and Japan.
For similar services in Europe, e-mail specific requirements to: customsystems.europe@compaq.com |
|
|
- Pre-packaged VIS services are recommended for popular AlphaServer GS80 system
configurations that include one storage array:
- Basic Integration Service (YT-CSSIT-V1) System integration, testing, extended burn-in,
custom documentation, and installation of a single operating system instance
- Partioning Service (YT-CSSIT-P1) Configuration of additional instances of an operating
system
- System integration, testing, extended burn-in, and custom documentation of
hardware-partitioned systems
|
|
| |
|
|
| Basic Integration Service |
Systems integration and delivery
services related to the configuration of the first and/or only instance of an operating
system on a single AlphaServer GS80 platform. Includes the following: |
YT-CSSIT-V1 |
|
- Staging and Integration of the AlphaServer GS80
|
|
|
- Software load of a single instance of an operating system and current revisions of
firmware
|
|
|
- Hardware configuration, custom placement, and integration of internal options of the
server per customer specifications
|
|
|
- Installation of a single instance of either Tru64 UNIX or OpenVMS Operating System
|
|
|
- Configuration, exercise, and test of up to one intelligent RAID array controller and
associated disks per customer requirements
|
|
|
- Testing of the system and its components for a full 100 hour burn-in
|
|
|
- Mini-CCD (Custom Configuration Documentation) containing equipment listing, system
environmental information, and software version levels
|
|
| |
|
|
| Partitioning
Service |
Configuration of multiple,
non-clustered instances of a second or subsequent operating system on a single AlphaServer
GS80 platform. This service is ordered along with the required YT-CSSIT-V1. Order one (1)
YT-CSSIT-P1 option for the second hardware partition and for each additional hardware
partition on an AlphaServer GS80 system. Includes the following: |
YT-CSSIT-P1 |
- Technical edit of order to guide component selection and option placement
|
|
|
- Software load of an instance of an operating system on a hardware/software partition
|
|
|
- Configuration and hardware integration (as described above) of the server partition per
specifications
|
|
|
- Partition testing with the system and its components during the 100 hour burn-in
|
|
| |
|
|
| Extra RAID Pair Service |
Configuration of additional
Intelligent RAID controller pairs beyond the internal and external RAID controllers pairs
included within the scope of the prerequisite
YT-CSSIT-V1 and/or optional YT-CSSIT-P1 services on the same single AlphaServer GS80
platform. The following services are included in the optional YT-CSSIT-R1 Extra RAID Pair
Service per each additional pair of Intelligent RAID controllers configured: |
YT-CSSIT-R1 |
|
- Technical edit of order to guide component selection and option placement
|
|
|
- Configuration of the disks of the additional controller pair per customer specifications
|
|
|
- Hardware configuration verification
|
|
|
- Custom disk placement and verification
|
|
|
- Installation of current revisions of firmware
|
|
|
- Configuration, exercise and testing of up to one pair of additional intelligent array
controller pair and associated disk drives for each YT-CSSIT-R1
|
|
|
- Controller and disk testing with the system and its components during the 100 hour
burn-in
|
|
| |
|
|
| Clustering Service |
Configuration of a single cluster
instance for AlphaServer GS80 platforms. This is a per-cluster service and is ordered
along with the prerequisite YT-CSSIT-V1 services. |
YT-CSSIT-C1 |
|
- Technical edit of order to guide component selection and option placement
|
|
|
- Configuration of a cluster per specifications
|
|
|
- Hardware and software configuration verification
|
|
|
- Installation of either Tru64 UNIX TruCluster software or OpenVMS cluster software and
configuration of node functions
|
|
|
- Installation of current revisions of firmware
|
|
|
- Cluster failover testing with the system and its components during the full 100 hour
burn-in
|
|
| |
|
|
| Full Custom Configurations |
The Integration Service Packages
address the most-common customer requirements. For a wider range of configurations,
customers can also choose additional customized services based upon a Statement of Work
agreement. This includes: cluster add-on nodes, larger storage configurations, custom
option support, custom system packaging, mixed operating system partitions, and configured
multi-system clusters. Contact your Custom Solutions provider or Sales Representative for
these services. |
|
| |
|
|
|