contents
 Overview   Standard Features   SystemsOptions   Options   Upgrades   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) QuickSpecs

hp AlphaServer ES80

spacerw.gif (802 bytes)  

 

11031_OV.jpg (58500 bytes)
spacerw.gif (802 bytes)
At A Glance

AlphaServer?/font> ES80 systems  

  • Two, four, six, or eight 1000-MHz Alpha 21364 processors
  • Advanced on-chip memory controllers and switch logic capable of providing 10.7-GB/s of peak memory bandwidth per processor
  • Choice of memory options; up to 4-GB of RDRAM memory per processor (32-GB total for an 8P system) - Future expansion to 8-GB/processor planned
  • Redundant features providing maximum uptime - N+1 Voltage Regulator Modules (VRMs); hot- plug redundant power supplies; cooling provided by four hot-plug redundant system fans
  • Optional RAID memory support
  • Up to 42 PCI/PCI-X I/O slots
    (8P system with I/O expansion)
  • Up to six AGP slots
    (8P system with I/O expansion))
  • Internal hot-plug drive storage of 1.1TB (8P system)
  • Integrated Ultra3 SCSI controller (one per System Building Block Drawer)
  • CD-RW drive
  • Dual USB port (one per System Building Block Drawer)
  • Enhanced reliability with ECC-protected memory, processor cache and system data paths
  • Tru64 UNIX or OpenVMS factory installed software (FIS); optional high availability support with Tru64 UNIX and OpenVMS cluster solutions
  • Product warranty, 1-year hardware, on-site next business day and 90-day software, telephone support delivered by HP Services
  • Consult the HP Customer Support Center at 1-800-345- 1518 for details
contents
 Overview   Standard Features   SystemsOptions   Options   Upgrades   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) Standard Features
Processor Two, four, six, or eight Alpha 21364 1000-MHz CPUs
 
Cache Memory 1.75-MB ECC L2 on-chip cache per CPU
 
Architecture Glue-less processor-to-processor multiprocessor architecture constructed from a set of basic components:
  • System Building Block Drawers
  • CPU Building Block Modules
  • I/O Expansion Drawers
 
CPUs, Memory, and I/O slots ES80 Model 2 ES80 Model 4 ES80 Model 6 ES80 Model 8
Maximum CPUs supported 2 4 6 8
Maximum memory supported 8 GB 16 GB 24 GB 32 GB
Maximum PCI/PCI-X slots supported 16 32 48 64
Maximum AGP slots supported 2 4 6 8
       
Storage Controller Integrated Ultra3 SCSI controller for internal disk drives (One per System Building Block Drawer)
 
Interfaces USB One Dual USB port per System Building Block Drawer
Server Management One MBM Server Management LAN Connection per System Building Block Drawer
Serial One MBM serial connection per System Building Block Drawer
 
Form Factor Rack (mounting slide rails included)
  
Boot/Diagnostic Devices CD-R Slim-line multi-bay 16X/10X/24X CD-RW
Hard Drives Choice of 18.2/36.4/72.8/146-GB SCSI disk drives
Internal Disk Expansion Total Internal Drive Bays Model 2 - Up to 2 drives may be mounted in the System Building Block Drawer
Model 4 - Up to 4 drives may be mounted in the two System Building Block Drawers
Model 6 - Up to 6 drives may be mounted in the three System Building Block Drawers
Model 8 - Up to 8 drives may be mounted in the four System Building Block Drawers
Up to 14 drives may be mounted in each optional StorageWorks Universal Shelves
 
Power Supplies Two @208V (700–Watt @120V) 48V auto-sensing power supplies, hot swappable, N+1
Cabinets require power distribution units, NA or International variant
  
OS Support AlphaServer ES80Tru64 UNIX systems include pre-installed software, Base license, Unlimited User license, Server Extension license, Internet Express, and Secure Web Server
AlphaServer ES80 OpenVMS systems include pre-installed software, Base license with System Manager license and Enterprise Integration Server License Package for OpenVMS
Minimum OS support - Tru64 UNIX V5.1B + IPK or OpenVMS V7.3-1 plus VMS731-EV7_V0100 upgrade kit
NOTE: For the complete list of supported options, refer to the following Web page:
http://h18002.www1.hp.com/alphaserver/es80/es80_tech.html
 
Service and Support Protected by HP Services including a 1-year on-site hardware warranty Training, consulting, network integration, software support, comprehensive system maintenance and guaranteed uptime services are also available for customers requiring higher levels of service and support.
contents
 Overview   Standard Features   SystemsOptions   Options   Upgrades   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) SystemsOptions
Step 1 - Assess Application Requirements
  • Selection of system components must be made in the context of total application requirements. Although the configuration of system components must be done in steps (for example, base system, CPUs, memories, etc.), these steps should not be done in isolation.
  • The order in which requirements are assessed is also important, since one requirement may impact others. Before proceeding, it would be useful to assess the total application requirements in the following order:
  • What level of availability is required?
  • If no single points of failure are allowed, then the solution should be configured as a multi-system cluster.
  • If access to specific devices must be assured, consider redundant adapters, RAID, redundant I/O Expansion Drawers, etc.
  • What overall capacities are required in terms of performance, memory capacity, and disk storage?
  • How should the system be configured to optimize performance?
  • In most cases, optimum performance is achieved if the system resources (CPUs, memory and I/O adapters) are balanced across the System Building Blocks in the system.
  • Memory should be configured according to application guidelines listed in Step 4.
  • What are the near-term system expansion needs?
NOTE: Most configuration steps require that the above data be considered in whole or in part. Be sure to execute each step in the context of the total application requirements.
NOTE: Support for hard partioning and soft partioning (Galaxy) planned for a future date.
 
System Ordering Requirements:
Certain system components or services are either required for normal operation or are recommended for best system performance and/or operation. This document uses the following definitions to specify these options:
  • Mandatory purchase: The system cannot function without this option or service - the option or service must be ordered with the system.
  • Required to function: This option or service is needed to support a working system - the option or service must be ordered with the system or be available onsite.
  • Recommended: System performance or function will be enhanced if this option or service is ordered.
  
Step 1b - System Requirements
AlphaServer ES80 systems require selection of the following items:
Mandatory Purchases:
  • One Base System (see Step 2)
  • One CPU Building Block Module (see Step 3)
  • Memory option(s) (see Step 4)
  • One system disk drive (see Step 5)
  • Ethernet adapter (see Step 11)
Optional Purchases:
  • Software media and documentation only required for first system onsite
  • Country-specific keyboard and mouse only if required (see Step 14)
  • See Step 7 for 11000 Series Cabinet, PDU, and Factory Integration Service if required
Recommended Services:
  • CarePaq Priority Service Plan
   
System Management Hardware/Software Requirements
NOTE: The following Server Management requirements only apply to customers who prefer to use the AMS or AMU Server Management software.
  • The AlphaServer Management Station (AMS) provides the highest level of server management for a single or multi platform environment.
    The AMS provides for a local or remote web accessible central point of management and control for a multiple ES47/ES80/GS1280 environment
  • The AlphaServer Management Station (AMS) software requires the following hardware in order to operate:
    - Tru64 UNIX platform with 1-GB memory, 1-GB disk space, and two network interface cards running Tru64 UNIX V5.1B
  • The AlphaServer Management Utility provides the next highest level of server management. The AMU is a GUI based application that provides a sophisticated, yet user-friendly graphics interface to monitor and manage a single ES47/ES80/GS1280 system. From this application, the user can monitor the status of the platform, and provide a significant level of control of the platform. The AMU is a Web based utility, which allows a user local and remote access from a browser.
  • The AlphaServer Management Utility (AMU) requires one of the following hardware platforms in order to operate:
    - Wintel Platform running Windows 2000, 500-MHz CPU or faster, 1-GB memory, 10-GB disk space
    - Tru64 UNIX platform running V5.1B or later, 1-GB memory, 10-GB disk space
  • Both the AMS and AMU Software require Internet Explorer 5 or later or Netscape 6
    
Step 2 - Select base system
  • Mandatory selection of at least one Base System required
Base Systems include:
  • Model 2 systems include one System Building Block Drawer
  • Model 4 systems include two System Building Block Drawers
  • Model 6 systems include three System Building Block Drawers
  • Model 8 systems include four System Building Block Drawers

NOTE: Base systems do not include CPUs or memory (see Steps 3 and 4)
Each System Building Block Drawer includes:

  • Space for one CPU Building Block Module (CPU Building Block Module contains two processors (Step 3) and space for four memory options (Step 4)
  • Five PCI-X slots, one AGP 2X slot
  • Two redundant power supplies
  • Two disk drive bays (see Step 5)
 
AlphaServer ES80 Base Systems
Model OS CPUs Supported
(See Step 3)
I/O Slots Order No.
Model 2 Tru64 UNIX 2 5 PCI-X, 1 AGP DA-20AAA-AA
Model 2 OpenVMS 2 5 PCI-X, 1 AGP DY-20AAA-AA
Model 4 Tru64 UNIX 4 10 PCI-X, 2 AGP DA-40AAA-AA
Model 4 OpenVMS 4 10 PCI-X, 2 AGP DY-40AAA-AA
Model 6 Tru64 UNIX 6 15 PCI-X, 3 AGP DA-60AAA-AA
Model 6 OpenVMS 6 15 PCI-X, 3 AGP DY-60AAA-AA
Model 8 Tru64 UNIX 8 20 PCI-X, 4 AGP DA-80AAA-AA
Model 8 OpenVMS 8 20 PCI-X, 4 AGP DY-80AAA-AA
  
Step 3 - CPU Building Block Module - Mandatory
  • Mandatory selection of one CPU Building Block Module required per ES80 Model 2 system
  • Mandatory selection of two CPU Building Blocks Modules required per ES80 Model 4 system
  • Mandatory selection of three CPU Building Block Modules required per ES80 Model 6 system
  • Mandatory selection of four CPU Building Blocks Modules required per ES80 Model 8 system
  • CPU Building Block Module includes two Alpha 21364 CPUs
  • Selection of CPU Building Block Module type (Tru64 UNIX or OpenVMS) must match base system operating system selected in Step 2
AlphaServer ES80, Dual CPU Building Block, 2xEV7 CPUs, 1000-MHz, Tru64 UNIX SMP License 3X-KN73A-AB
AlphaServer ES80, Dual CPU Building Block, 2xEV7 CPUs, 1000-MHz, OpenVMS SMP License 3X-KN73A-AC
contents
 Overview   Standard Features   SystemsOptions   Options   Upgrades   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) Options
Step 4- Memory - Mandatory
Memory Configuration Guidelines
Memory options should be selected in the context of the application’s sensitivity to memory bandwidth and future memory capacity expansion. This will determine the number of memory options to order. The total capacity required will determine the size of the options to be ordered.
  • Mandatory selection of memory option required
    • ES80 Model 2 systems require a minimum of one memory option
    • ES80 Model 2 systems ordered with one I/O Expansion Drawer require a minimum of two memory options
    • ES80 Model 4 systems require a minimum of two memory options
    • ES80 Model 4 systems ordered with one I/O Expansion Drawer require a minimum of three memory options
    • ES80 Model 4 systems ordered with two I/O Expansion Drawers require a minimum of four memory options
    • ES80 Model 6 systems require a minimum of three memory options
    • ES80 Model 6 systems ordered with one I/O Expansion Drawer require a minimum of four memory options
    • ES80 Model 6 systems ordered with two I/O Expansion Drawers require a minimum of five memory options
    • ES80 Model 8 systems require a minimum of four memory options
    • ES80 Model 8 systems ordered with one I/O Expansion Drawer require a minimum of five memory options
    • ES80 Model 8 systems ordered with two I/O Expansion Drawers require a minimum of six memory options
  • Each ES80 Model 2 system supports up to four memory options (four RIMMs each) and up to four memory RAID options
    (one RIMM each) for a total of 20 RIMMs.
  • ES80 Model 4 system supports up to eight memory options and up to eight memory RAID options for a total of 40 RIMMs.
  • ES80 Model 6 system supports up to 12 memory options and up to 12 memory RAID options for a total of 60 RIMMs.
  • ES80 Model 8 system supports up to 16 memory options and up to 16 memory RAID options for a total of 80 RIMMs.
  • If an I/O Expansion Drawer is ordered (see Step 6), both CPUs in the CPU Building Block Module connected to the I/O Drawer must contain memory in at least one memory controller.
  • Each CPU has two memory controllers – Each memory controller can support four RIMMs (one memory option) and a fifth
    RIMM slot for redundancy (RAID option).
  • If populated, the two memory controllers per CPU must contain the same size RIMMs.
  • Order one RAID option (one RIMM) per memory option if desired.
    • If RAID memory option is selected, the number of RAID options selected must equal the number of memory options selected.

The following examples illustrate different ways of configuring an ES80 Model 4 system with a total of 4 GB (1 GB per CPU)

       CPU Building Block Module 1 CPU Building Block Module 2
Memory Option CPU 1 CPU 2 CPU 3 CPU 4
Controller 1 Controller 2 Controller 1 Controller 2 Controller 1 Controller 2 Controller 1 Controller 2
3X-MS7AB-AA (4x128MB) 1 1 1 1 1 1 1 1
3X-MS7AB-BA (4x256MB) 1 - 1 - 1 - 1 -
3X-MS7AB-CA (4x512MB) 1 - - - 1 - - -
 
Memory Application Examples
Configuring memory is a compromise between cost, total memory capacity, and memory bandwidth requirements. The behavior of the application must be used to define the most-desired configuration. Some applications are sensitive to memory capacity while some are sensitive to memory bandwidth. If actual application measurements are not available, the following may be used as guidelines:
  • Large memory (VLM) applications, in which large amounts of memory can substantially reduce I/O, may be optimized for total memory capacity and future capacity growth. In VLM applications, the right balance might be one memory option per CPU. (Case B)
  • Typical commercial applications, such as transaction processing (OLTP) and multi-user timesharing, usually operate efficiently from cache and may not be materially affected by memory bandwidth. Memory configuration is a balance between memory bandwidth and future capacity growth. It is advisable to match the number of memory options to the number of CPUs. (Case B)
  • Data mining can benefit from additional memory bandwidth. In these cases, configure four memory options, two per CPU. (Case A)

The most demanding high-performance technical applications (HPTC) achieve a performance level that is directly proportional to memory bandwidth. In these cases, configure four memory options, two per CPU. (Case A)

512-MB RDRAM Memory (4x128) Option

3X-MS7AB-AA

512-MB RDRAM Memory (1x128) RAID Option

3X-MS7AB-AC

1-GB RDRAM Memory (4x256) Option

3X-MS7AB-BA

1-GB RDRAM Memory (1x256) RAID Option

3X-MS7AB-BC

2-GB RDRAM Memory (4x512) Option

3X-MS7AB-CA

2-GB RDRAM Memory (1x512) RAID Option

3X-MS7AB-CC

 
Step 5 - Select System Disk
  • Mandatory selection of at least one system disk drive is required for each ES80 system ordered. NOTE: Integrated Ultra3 SCSI controller for internal disk drives and cabling included.
  • AlphaServer ES80 Model 2 systems support up to two internal hard disk drives
  • AlphaServer ES80 Model 4 systems support up to four internal hard disk drives
  • AlphaServer ES80 Model 6 systems support up to six internal hard disk drives
  • AlphaServer ES80 Model 8 systems support up to eight internal hard disk drives
36.4-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive

3R-A3838-AA

72.8-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive

3R-A3839-AA

146-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive

3R-A3841-AA

18.2-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive

3R-A3848-AA

36.4-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive

3R-A3849-AA

72.8-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive

3R-A3851-AA

I/O Configuration Guidelines:
  • Each System Building Block Drawer in an AlphaServer ES80 system supports six total slots spread over three buses (ports). The following details the internal I/O slots:
Port # Slot # Maximum Bus Speed Signal Voltage Number of Devices Supported
0 1 133 MHz 3.3V 1 – 133 MHz or 66 MHz PCI-X or
1 – 66 or 33 MHz PCI
1 1 66 MHz 3.3V 2 – 66 MHz PCI-X or
2 – 66 MHz PCI or
4 – 33 MHz PCI
2 66 MHz 3.3V
3 66 MHz 3.3V
4 66 MHz 3.3V
3 1 2X AGP 1.5V 1 – 1X or 2X AGP
NOTE: ES80 Model 2 Base Systems contain one System Building Block Drawer; ES80 Model 4 Base Systems contain two System Building Block Drawers; ES80 Model 6 Base Systems contain three System Building Block Drawers; ES80 Model 8 Base Systems contain four System Building Block Drawers
  • AlphaServer ES80 Model 2 system supports one optional I/O Expansion Drawer
  • AlphaServer ES80 Model 4 systems support up to two optional I/O Expansion Drawer
  • AlphaServer ES80 Model 6 supports up to three optional I/O Expansion Drawers; Model 8 systems support up to four I/O Expansion Drawers
  • Each I/O Expansion Drawer supports 12 total slots spread over four buses (ports)

The following details the External I/O Expansion Drawer slots:
Port # Slot # Maximum Bus Speed Signal Voltage Number of Devices Supported
0 1 33 MHz 3.3V 1 – 33 MHz PCI
2 33 MHz 5.0V 1 – CCMAB-AA (Memory Channel) or
1 – CIPCA-BA or
2 – 3X- KZPBA-CC
(NOTE: No mixing of options within 5v slots)
3 33 MHz 5.0V
1 1 133 MHz 3.3V 2 – 66 or 33 MHz PCI or
2 – 66 MHz PCI-X or
1(1) – 133 MHz PCI-X
2 133 MHz 3.3V
2 1 66 MHz 3.3V 6 – 33 MHz PCI or
3(2) – 66 MHz PCI or
2 – 66 MHz PCI- X
2 66 MHz 3.3V
3 66 MHz 3.3V
4 66 MHz 3.3V
5 66 MHz 3.3V
6 66 MHz 3.3V
3 1 2X AGP 1.5V 1 – 1X or 2X AGP
NOTE: (1) Two 133 MHz PCI-X devices are supported in Port 1, slots 1 and 2; they will however operate at 100 MHz.
(2) Five 66 MHz PCI devices are supported in Port 2, slots 1-5; they will however operate at 50 MHz.
Modules designed for 5.0v signaling and 33-MHz bus speed can only operate in Port 0 – slots 2 and 3 (reserved for Memory Channel or CIPCA)
Modules designed for 3.3v signaling and 66-MHz bus speed can not operate in Port 0 – slots 2 and 3
Universal PCI modules capable of operating at 66 MHz will operate at 33 MHz when placed in a 33-MHz slot
Step 6 - I/O System Expansion (Optional)
I/O Expansion Drawer
  • Model 2 systems support one I/O Expansion Drawer; Model 4 supports two, Model 6 supports three, and Model 8 supports four
  • I/O Expansion Drawers contain 11 PCI/PCI-X slots and one AGP 2X slot and an N+1 redundant power system
  • I/O Expansion Drawer required for Memory Channel network adapter or CIPCA (PCI-CI) adapter
I/O Expansion Drawer – Factory Installed

3X-BA70A-BA

I/O Expansion Drawer – Field Installable

3X-BA70A-ZB

I/O cable for connection between System Building Block Drawer and I/O Expansion Drawer shelves mounted in system power cabinet; one mandatory per each I/O Expansion Drawer ordered

3X-BNPCB-02

 
Step 7 - 11000 Series Cabinets
  • 11000 Series Cabinet enclosures support ES80 System Building Block Drawers, I/O Expansion Drawers, and
    StorageWorks Shelves (see configuration chart below)
  • All ES80 Base Systems include all necessary hardware to mount the systems in an 11000 Series Cabinet
  • All ES80 Base Systems include all required internal IEC/IEC power cords
  • 11000 Series Cabinets require the mandatory selection of the following items:
      1. 11000 Series Cabinets: 3X-H9A45-ZD (41U) or 3X-H9A40-ZA (34U)
      2. Three-phase Power Distribution Unit(s): Choice of 3X-H7606-AA (North America 120/208V) or
        3X-H7606-AB (International 380/415V)
      3. Factory integration: YS-ASCAA-AA
  • 3X-H9A45-ZD/3X-H9A40-ZA includes one Cable/DSL Hub
NOTE: For configurations beyond those listed in the following charts, or for mounting ES80 systems in non-11000 series cabinet, contact CustomSystems.
Number of Systems for mounting in
3X-H9A45-ZD (41U) Cabinet – Using one 30A
three-phase PDU (3X-H7606-AA/AB)
Number of I/O Drawers and/or DS43XX StorageWorks
Shelves for mounting in
3X-H9A45-ZD (41U) Cabinet
  ES80 Model 2   ES80 Model 4 ES80 Model 6   ES80 Model 8 I/O Expansion
Drawers
Max. DS43xx
SW Shelves
Total U’s Consumed 3X-H9A45-ZA Cab Extra
U’s
Size in U's 4U   8U 12U   16U 4U 3U   41U  
Configuration #1 1   - -   - 0 10 40 41 1
Configuration #2 1   - -   - 1 9 41 41 0
Configuration #3 2 or 1 -   - 0 9 41 41 0
Configuration #4 2 or 1 -   - 1 7 39 41 2
Configuration #5 2 or 1 -   - 2 6 40 41 1
Configuration #6 3 or - 1   - 0 7 39 41 2
Configuration #7 3 or - 1   - 1 6 40 41 1
Configuration #8 3 or - 1   - 2 5 41 41 0
Configuration #9 3 or - 1   - 3 3 39 41 2
Configuration #10 4 or 2 - or 1 0 6 40 41 1
Configuration #11 4 or 2 - or 1 1 5 41 41 0
Configuration #12 4 or 2 - or 1 2 3 39 41 2
Configuration #13 4 or - -   1 3 2 40 41 1
Configuration #14 4 or - -   1 4 1 41 41 0
NOTE: For redundancy on any configuration listed above, order second PDU (3X-H7606-AA/AB).
Each 3X-H9A45-ZD/3X-H9A40-ZA cabinet includes one Cable/DSL Hub. In order to fully utilize the Server Management capabilities (i.e. running AMS or AMU software), each Model 2 or Model 4 system ordered must have a Cable/DSL Hub.
The Hub included with the cabinet supports the 1st system (Model 2 or Model 4) mounted in the cabinet.
An additional Hub is required for each additional system (Model 2 or Model 4) mounted in the cabinet.
For serial console or VGA operation of the system, the Cable/DSL Hub is not required.
  

Number of Systems for mounting in
3X-H9A40-ZA (34U) Cabinet – Using one 30A
three-phase PDU (3X-H7606-AA/AB)

Number of I/O Drawers and/or DS43XX StorageWorks
Shelves for mounting in
3X-H9A40-ZA (34U) Cabinet

    ES80 Model 2   ES80 Model 4 ES80 Model 6   ES80 Model 8 I/O Expansion
Drawers
Max. DS43xx
SW Shelves
Total U’s Consumed 3X-H9A40-ZA Cab Extra
U’s
Size in U's 4U   8U 12U   16U 4U 3U   34U  
Configuration #1 1   - -   - 0 8 34 34 0
Configuration #2 1   - -   - 1 6 32 34 2
Configuration #3 2 or 1 -   - 0 6 32 34 2
Configuration #4 2 or 1 -   - 1 5 33 34 1
Configuration #5 2 or 1 -   - 2 4 34 34 0
Configuration #6 3 or - 1   - 0 5 33 34 1
Configuration #7 3 or - 1   - 1 4 34 34 0
Configuration #8 3 or - 1   - 2 2 32 34 2
Configuration #9 3 or - 1   - 3 1 33 34 1
Configuration #10 4 or 2 - or 1 0 4 34 34 0
Configuration #11 4 or 2 - or 1 1 2 32 34 2
Configuration #12 4 or 2 - or 1 2 1 33 34 1
Configuration #13 4 or - -   1 3 0 34 34 0
Configuration #14 4 or - -   1 3 0 34 34 0
NOTE: For redundancy on any configuration listed above, order second PDU (3X-H7606-AA/AB).
Each 3X-H9A45-ZD/3X-H9A40-ZA cabinet includes one Cable/DSL Hub. In order to fully utilize the Server Management capabilities (i.e., running AMS or AMU software, each Model 2 or Model 4 system ordered must have a Cable/DSL Hub.
The Hub included with the cabinet supports the 1st system (Model 2 or Model 4) mounted in the cabinet.
An additional Hub is required for each additional system (Model 2 or Model 4) mounted in the cabinet.
For serial console or VGA operation of the system, the Cable/DSL Hub is not required.
11000 Series Cabinets
11000 Series Cabinets 41U 11000 Series Cabinet 3X-H9A45-ZD
34U 11000-Series Cabinet 3X-H9A40-ZA
Power Distribution Unit – Mandatory
(if cabinet is ordered)
120/208V Y or 200V, 30A NEMA L21-30P plug 3 x C19 outlets plus 24 x C13 outlets 3X-H7606-AA
380/415V Y, IEC 309 32A 6h/230/400~ plug 3 x C19 outlets plus 24 x C13 outlets 3X-H7606-AB
Factory Integration – Mandatory
(if cabinet is ordered)
Factory Integration of systems and storage devices assembled and configured in cabinet enclosure in predefined locations YS-ASCAA-AA
Cable/DSL Hub - Optional Cable/DSL 8-port Hub - only required when more than one Model 2 or Model 4 is mounted in the same cabinet and the Server Management capabilities need to be fully utilized. 3X-DGHUB-AA
 
Step 8- Storage Adapters/Controllers
  Maximum # Supported    
Tru64 UNIX OpenVMS


Per
System
Per External I/O Drawer Per 2P Building Block Drawer

Per
System
Per External I/O Drawer Per 2P Building Block Drawer Speed PCI/
PCI-X
Slot
 
SCSI
NOTE: Maximum storage controllers per systems, all types - Tru64 UNIX: 32, OpenVMS: 26
PCI 2-port Ultra3 (LVD) SCSI adapter, 64-bit/66-MHz
dual-channel (uses one PCI slot); includes internal 68-pin and external 68-pin VHDCI connectors; requires
3X-BC56J-xx cable to connect adapter to DS-SL13R-Bx shelf; HSZxx RAID controllers not supported. No shared SCSI or tape support, no SDLT tape support. No support for Model 4314R single-bus shelves with 3X-KZPEA-DB adapter. Tru64 UNIX requires graphics adapter to run console utilities (RUN BIOS).
16 8 4 12 8 4 66 MHz 3.3V PCI

3X-KZPEA-DB

Ultra160 cable, VHDCI to VHDCI (341174-B21 – 6-feet, 341175-B21 – 12-feet, 164604-B21 – 24-feet) xx = 02 (6-feet), 03 (12-feet), 04 (24-feet)  

3X-BC56J-xx

 
PCI 1-port Ultra2 (LVD) SCSI adapter, 32-bit/33-MHz, single-channel (uses one PCI slot); includes internal
68-pin and external 68-pin HD connectors; order
BN38C-xx cable to connect adapter to Ultra3 shelf, or order VHDCI converter (BN38E-0B) for use with included cable; HSZxx RAID controllers not supported. No support for shared SCSI.
8 8 4 8 8 4 33 MHz 3.3V PCI

3X-KZPCA-AA

 
PCI 1-port UltraSCSI wide differential 32-bit/33-MHz PCI adapter (uses one PCI slot); includes external 68-pin HD connector, requires BN38C-xx cable (2 to 25 meters) to connect adapter to differential UltraSCSI shelf or RAID controller 4 2 0 4 2 0 33 MHz 3.3V PCI

3X-KZPBA-CC

68-pin HD male-to-VHDCI male UltraSCSI cable;
xx = 02, 03, 05, 10, 20, meters
  

BN38C-xx

  
RAID
Ultra160 2-channel internal RAID controller with 128-MB cache. NOTE: One controller supported per bus segment; supported only as a data device. - - - 1 1 1 66 MHz 3.3V PCI

3X-KZPDC-BE

Ultra160 4-channel internal RAID controller with 256-MB cache. NOTE: One controller supported per bus segment; supported only as a data device. - - - 1 1 1 66 MHz 3.3V PCI

3X-KZPDC-DF

Ultra160 cable, VHDCI to VHDCI (341174-B21 – 6-feet, 341175-B21 – 12-feet,   164604-B21 – 24-feet)
xx = 02 (6-feet), 03 (12-feet), 04  (24-feet)
  

3X-BC56J-XX

  
Fibre Channel
PCI to 2-Gbit Fibre Channel adapter, 64-bit/66-MHz, single-channel 16 8 4 16 8 4 66 MHz 3.3V PCI

DS-KGPSA-DA

PCI to Fibre Channel Host Bus Adapter, 64-bit/66-MHz             66 MHz 3.3V PCI

DS-SWLA4-PD

Fibre Channel cable (BNGBX-xx)
xx=02, 03, 05, 10, 15, 30, 50 meters
  

BNGBX-xx

     
CI    
PCI CI adapter, requires two PCI slots - Each PCI CI adapter ordered requires the mandatory selection of an I/O Expansion Drawer (see Step 6) NA NA NA 2 1 0 33 MHz 5V

CIPCA-BA

Computer interconnect cable set, connects CIPCA to star coupler; select length xx=10, 20, 45 meters  

BNCIA-xx

Step 9- StorageWorks Universal Shelves
StorageWorks Model 4314R and Model 4354R Universal Drive Shelves
StorageWorks Model 4314R and 4354R Ultra3 SCSI (LVD) single-bus and split-bus Universal drive shelves; refer to StorageWorks Enclosure 4300 Family QuickSpecs when configuring shelves. When selecting a DS-SL13R-Bx split-bus shelf, two SCSI channels are required. No support for Model 4314R or 4314T single-bus shelves with 3X-KZPEA-DB adapter. Note that the depth of a DS-SL13R-xx shelf does not allow front and rear mounting. Note: DS-SL13R single-bus shelves include one 12-foot VHDCI to VHDCI SCSI cable; dual-bus shelves include two 12-foot VHDCI to VHDCI SCSI cables.
StorageWorks Model 4314R Ultra3 SCSI (LVD) single-bus Universal drive rackmount shelf, includes one power supply. No support for Model 4314R single-bus shelves with embedded Ultra3 SCSI adapter or 3X-KZPEA-DB adapter

DS-SL13R-AA

StorageWorks Model 4314R Ultra3 SCSI (LVD) single-bus Universal drive rackmount shelf, includes one power supply. No support for Model 4314R single-bus shelves with embedded Ultra3 SCSI adapter or 3X-KZPEA-DB adapter

DS-SL13R-AJ

StorageWorks Model 4354R Ultra3 SCSI (LVD) split-bus Universal drive rackmount shelf, includes two redundant power supplies, U.S.

DS-SL13R-BA

StorageWorks Model 4354R Ultra3 SCSI (LVD) split-bus Universal drive rackmount shelf, includes two redundant power supplies, Japan

DS-SL13R-BJ

 
Disk Drives (Supported in Model 4314R and 4354R Universal Drive Enclosures)
36.4-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive

3R-A3838-AA

72.8-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive

3R-A3839-AA

146-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive

3R-A3841-AA

18.2-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive

3R-A3848-AA

36.4-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive

3R-A3849-AA

72.8-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive

3R-A3851-AA

 
Step 10 - Storage Options
Step 10a – Tape Devices
AIT Hot-plug Tape Drives (for use in StorageWorks Model 4314R and 4354R Universal Drive Shelves)
  • AIT hot-plug tape drives require two Universal slots
AIT 35/70-GB hot-plug LVD Universal tape drive, uses two slots in 43xxx shelves

3R-A2396-AA

AIT 50/100-GB hot-plug LVD Universal tape drive, uses two slots in 43xxx shelves

3R-A2779-AA

 
Autoloaders AIT 35-GB rackmount autoloader, 8 cartridge, U.S.

280349-001

Same as above, International

280349-B31

AIT rail kit for rackmount autoloader

284930-001

 
AIT Tape Libraries SSL2020 AIT rackmount library with one AIT 50-GB drive and 20 slots, LVD

175196-B21

SSL2020 AIT rackmount library with two AIT 50-GB drives and 20 slots, LVD

175196-B22

 
DAT Hot-plug Tape Drive DAT 20/40-GB DDS4 hot-plug LVD Universal tape drive, uses two slots in 43xxx shelves

3R-A2780-AA

  
DLT/SDLT Tape Libraries MSL5026DLX, DLT rackmount library with 1 40/80-GB DLT tape drive, LVD

231891-B21

MSL5026DLX, DLT rackmount library with 2 40/80-GB DLT tape drives, LVD

231891-B22

MSL5026SL, SDLT rackmount library with 1 110/220-GB SDLT tape drive, LVD; graphite

302512-B21

MSL5026SL, SDLT rackmount library with 2 110/220-GB SDLT tape drives, LVD; graphite

302512-B22

 
MSL5026S2, SDLT rackmount library with 0 drives, LVD; graphite

293472-B21

MSL5026S2, SDLT rackmount library with 1 160/220-GB SDLT tape drive, LVD; graphite

293472-B22

MSL5026S2, SDLT rackmount library with 1 160/220-GB SDLT tape drive, LVD; graphite

293472-B23

MSL5026S2, SDLT rackmount library with 1 160/220-GB SDLT tape drive, Fibre Channel Interface; graphite

293472-B24

MSL5026S2, SDLT rackmount library with 2 160/220-GB SDLT tape drives, Fibre Channel Interface; graphite

293472-B25

MSL5000 SDLT2 upgrade drive, all

293475-B21

MSL5052SL SDLT rackmount library, 0 drives, LVD

255102-B21

MSL5052SL SDLT rackmount library with 2 110/220-GB drives, LVD

249491-B21

MSL5052SL SDLT 110/220-GB drive field upgrade, LVD

231823-B22

MSL5052S2, SDLT rackmount library with 2 160/220-GB SDLT tape drives, LVD; graphite

293474-B21

MSL5052S2, SDLT rackmount library with 2 160/220-GB SDLT tape drives, Fibre Channel Interface; graphite

293474-B24

ESL9322S2 SDLT tape library, with 2 160/320-GB SDLT tape drives, 222 slots - requires 3X-KZPCA-AA adapter

293409-B22

ESL9322S2 SDLT tape library, with 8 160/320-GB SDLT tape drives, 222 slots - requires 3X-KZPCA-AA adapter

293409-B28

ESL9322S2 SDLT tape library, with 2 160/320-GB SDLT tape drives, 322 slots - requires 3X-KZPCA-AA adapter

293410-B22

ESL9322S2 SDLT tape library, with 8 160/320-GB SDLT tape drives, 322 slots - requires 3X-KZPCA-AA adapter

293410-B28

ESL9000 SDLT2 LVD Upgrade Drive

293414-B21

ESL9595SL SDLT tape library, 0 drives, 400 slots - requires 3X-KZPCA-AA adapter

274672-B21

ESL9595SL SDLT tape library, 2 drives, 400 slots - requires 3X-KZPCA-AA adapter

274672-B22

ESL9595SL SDLT tape library, 16 drives, 400 slots - requires 3X-KZPCA-AA adapter

274672-B28

ESL9595SL SDLT tape library, 0 drives, 500 slots - requires 3X-KZPCA-AA adapter

281627-B21

ESL9595SL SDLT tape library, 2 drives, 500 slots - requires 3X-KZPCA-AA adapter

281627-B22

ESL9595SL SDLT tape library, 16 drives, 500 slots - requires 3X-KZPCA-AA adapter

281627-B28

ESL9595SL SDLT tape library, 0 drives, 595 slots - requires 3X-KZPCA-AA adapter

281628-B21

ESL9595SL SDLT tape library, 2 drives, 595 slots - requires 3X-KZPCA-AA adapter

281628-B22

ESL9595SL SDLT tape library, 16 drives, 595 slots - requires 3X-KZPCA-AA adapter

281628-B28

ESL9595S2 SDLT2 tape library, 2 drives, 400 slots - requires 3X-KZPCA-AA adapter

293411-B22

ESL9595S2 SDLT2 tape library, 16 drives, 400 slots - requires 3X-KZPCA-AA adapter

293411-B28

ESL9595S2 SDLT2 tape library, 2 drives, 500 slots - requires 3X-KZPCA-AA adapter

293412-B22

ESL9595S2 SDLT2 tape library, 16 drives, 500 slots - requires 3X-KZPCA-AA adapter

293412-B28

ESL9595S2 SDLT2 tape library, 2 drives, 595 slots - requires 3X-KZPCA-AA adapter

293413-B22

ESL9595S2 SDLT2 tape library, 16 drives, 595 slots - requires 3X-KZPCA-AA adapter

293413-B28

ESL9000 SDLT2 LVD upgrade drive

293414-B21

 
3U 3U Rackmount Tape Drive Enclosure NOTE: The 3U Tape Drive Enclosure supports up to four internal half-height removable devices, or up to two full height devices. Select up to four AIT or DAT devices, or two DLT/SDLT devices with 3U Rackmount Tape Drive Enclosure (274338-B21), or select preconfigured configurations listed below
AIT 35/70-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black

216884-B21

AIT 50/100-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black

3R-A3753-AA

DAT 20/40-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black

3R-A3752-AA

DLT8000 40/80-GB tape drive, requires 3X-KZPCA-AA LVD adapter

146196-B22

SDLT 110/220-GB tape drive, requires 3X-KZPCA-AA LVD adapter

192106-B25

SDLT 160/320-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black

257319-B21

Preconfigured configurations
AIT 50-GB 3U rackmount kit, carbon black

274333-B21

DLT 40/80-GB, 3U rackmount kit, carbon black

274332-B21

DLT 40/80-GB, dual-drive, 3U rackmount kit, carbon black

274335-B21

SDLT 110/220-GB, 3U rackmount kit, carbon black

274331-B21

SDLT 110/220-GB, dual-drive, 3U rackmount kit, carbon black

274334-B21

 
5U 5U Rackmount Tape Drive Enclosure NOTE: The 5U Rackmount Tape Drive Enclosure supports four full-height devices; select up to four DLT or SDLT devices with 274339-B21, or select preconfigured configurations listed below
DLT8000 40/80-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black

146196-B22

SDLT 110/220-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black

192106-B25

SDLT 160/320-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black

257319-B21

Preconfigured configurations
SDLT 110/220-GB Tape Array III, 5U rackmount kit, carbon black

274336-B21

DLT 40/80-GB Tape Array III, 5U rackmount kit, carbon black

274337-B21

DLT Tape Array III Model 0 enclosure, U.S.

168047-001

Same as above, International

168047-B31

Same as above, Japan

168047-291

 
Step 10b – hp StorageWorks Network Storage Router M2402
2 Fibre Channel x 4 LVD SCSI Ports

3R-A3740-AA

2 Fibre Channel x 4 HVD SCSI Ports

3R-A3741-AA

Two Fibre Channel x 4 HVD FC to SCSI Data Router

3R-A3741-AA

Two Fibre Channel x 4 LVD FC to SCSI Data Router

3R-A3740-AA

 
Step 10c – External Storage Solutions/Controllers
41U graphite storage cabinet, M3220 Controller assembly with dual HSV110 controllers, 6 M5214 dual FC loop 14-bay drive enclosures, 4 FC loop switches; Model 2C6D-B, 60 Hz

DS-SV110-JA

41U graphite storage cabinet, M3220 Controller assembly with dual HSV110 controllers, 6 M5214 dual FC loop 14-bay drive enclosures, 4 FC loop switches; Model 2C6D-B, 50 Hz

DS-SV110-JB

41U graphite storage cabinet, M3220 Controller assembly with dual HSV110 controllers, 12 M5214 dual FC loop 14-bay drive enclosures, 4 FC loop switches; Model 2C12D-B, 60 Hz

DS-SV110-KA

41U graphite storage cabinet, M3220 Controller assembly with dual HSV110 controllers, 12 M5214 dual FC loop 14-bay drive enclosures, 4 FC loop switches; Model 2C12D-B, 50 Hz

DS-SV110-KB

Fibre Channel Controller (HSG80), includes 256-MB cache, requires following firmware:

8.6-4F ACS FW (222318-B22, QB-6BUAA-SD), one per controller
8.6-4S ACS FW (222364-B22, QB-6ENAA-SC), one per controller
8.6-4P ACS FW (222316-B22, QB-6CAAA-SD), one per controller
Requires Tru64 UNIX software: 222320-B23, QB-65RAB-SE, one per controller
Requires OpenVMS software: 222321-B22, QB-65RAC-SD, one per controller

DS-HSG80-BK

Additional 256-MB cache for HSG80

DS-HSDIM-AC

Single cache battery, one per HSG80 controller

DS-SE2CS-CB

Model 2200 controller shelf for HSG80 controller – only supported in 9000 Series and M-Series Cabinets

DS-SE2ZS-C8

 
Step 10d – Fibre Channel Options
The following disk drives, hubs, data routers, switches, and cables are used in Fibre Channel configurations using the DS-KGPSA-xx adapter.
Fibre Channel Disk Drives 36-GB 10K rpm dual-port 2-Gb/sec FC-AL 1-inch (25.4 mm) drive

3R-A3239-AA

36-GB 15K rpm dual-port 2-Gb/sec FC-AL 1-inch (25.4 mm) drive

3R-A3210-AA

72-GB 10K rpm dual-port 2-Gb/sec FC-AL 1-inch (25.4 mm) drive

3R-A3260-AA

Fibre Channel Hubs Fibre Channel 7-port Storage Hub, International (Tru64 UNIX only)

DS-SWXHB-I7

Fibre Channel 7-port Storage Hub, North America (Tru64 UNIX only)

DS-SWXHB-07

Fibre Channel 7-port Storage Hub, Japan (Tru64 UNIX only)

DS-SWXHB-J7

Fibre Channel Data Routers 1 Fibre Channel x 2 HVD data router

3R-A2673-AA

1 Fibre Channel x 2 LVD data router

3R-A2774-AA

2 x 4 LVD Fiber Channel to SCSI Network Storage Router

3R-A3740-AA

2 x 4 HVD Fiber Channel to SCSI Network Storage Router

3R-A3741-AA

Fibre Channel Switches Fibre Channel 2-Gb 8-port SAN switch

DS-DSGGD-AC

Fibre Channel 2-Gb 16-port SAN switch

DS-DSGGD-AD

Fibre Channel 2-Gb SAN switch – 16-port;

DS-DSGGD-BA

Fibre Channel 2-Gb 64-port Core Switch

DS-DSGGE-AB

McData 64-port Fibre Channel Director/Edge Class Switches SAN Director 64 (1 Gb) 32 ports, base model

DS-DMGGD-BA

SAN Director 64 Long-wave 4-port module kit

DS-DMGGD-AC

SAN Director 64 Short-wave 4-port module kit

DS-DMGGD-AD

SAN Director 64 Combo, Long – 1 port/Short – 3 ports - Wave Module Kit

DS-DMGGD-AE

HP StorageWorks Edge Switch 2/16

DS-DMGGE-BB

HP StorageWorks Edge Switch 2/32

DS-DMGGE-BC

NOTE: Connection for, or between, 1-Gb and/or 2-Gb SAN switches require different cables. Refer to the Switches, Hubs, and Interconnects QuickSpecs at: http://www.compaq.com/products/quickspecs/
North_America/10490.html
 
Fibre Channel Cables NOTE: The following LC-SC connector cables support connectivity between 1-Gb and 2-Gb devices.
2-meter LC-SC multi-mode Fibre Channel cable

3R-A2976-AA

5-meter LC-SC multi-mode Fibre Channel cable

3R-A2977-AA

15-meter LC-SC multi-mode Fibre Channel cable

3R-A2978-AA

NOTE: The following LC-LC connector cables support connectivity between 2-Gb and 2-Gb devices.
2-meter LC-LC multi-mode Fibre Channel cable

3R-A2979-AA

5-meter LC-LC multi-mode Fibre Channel cable

3R-A2980-AA

15-meter LC-LC multi-mode Fibre Channel cable

3R-A2981-AA

Step 11 - Networks and Communications
Step 11a - Networks and Communications - Mandatory
  • Mandatory selection of at least one of the following Ethernet adapters is required for each ES80 system ordered
  • Maximum network adapters supported per system, all types - Tru64 UNIX: 16, OpenVMS: 16
  Maximum # Supported  
Tru64 UNIX OpenVMS


Per
System
Per External I/O Drawer Per 2P Building Block Drawer

Per
System
Per External I/O Drawer Per 2P Building Block Drawer Speed PCI/
PCI-
X
Slot
 
Ethernet Adapters
PCI (32/64-bit, 33-MHz to 66-MHz) dual-port 10/100 Ethernet (UTP/RJ45s) NIC and Base Module. (One
3X-DE602-TA or 3X-DE602-FA optional add-on daughter card can be combined with this module.)

NOTE: Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
8 8 4 8 8 4 66 MHz 3.3/
5V

3X-DE602-BB

PCI-X/PCI Single-port 10/100/1000 Mbps (Twisted-pair Copper with RJ45) Gigabit Ethernet NIC. Cables - BN25G, BN26M, BN24Q, BN28Q, or equivalent with RJ45 connectors
NOTE: Only supported in PCI mode. Supported as a cluster interconnect under OpenVMS only. OpenVMS remedial kit required: EV7 Tima: DEC-AXPVMS–
VMS731_EV7-
V0100-
-4.PCSI
LAN Tima: DEC-AXPVMS-
VMS731_LAN-
V0100-
-4.PCSI
8 8 4 8 8 4 66 MHz 3.3V

3X-DEGXA-TA

  
Ethernet Adapters
Dual-port 10/100 Ethernet (UTP/RJ45) add-on daughter card for use with the 3X-DE602-BB only. The combined
3X-DE602-BB and 3X-DE602-TA modules provide four 10/100 (UTP/RJ45s) ports in a single PCI slot option

NOTE: 3X-DE602-TA cannot be used standalone.
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
8 8 4 8 8 4 33 MHz 3.3/
5V

3X-DE602-TA

Single-port 100 Mbps (MMF/duplex-SC) add-on daughter card for use with the 3X-DE602-BB. The combined 3X-DE602-BB and 3X-DE602-FA provides two 10/100 (UTP/RJ45s) and one 100Mbps (MMF/SC) ports in a single PCI slot option.
NOTE: 3X-DE602-FA cannot be used standalone. Use BN34A or BN34B cables.
8 8 4 8 8 4 33 MHz 3.3/
5V

3X-DE602-FA

PCI-X/PCI Single-port 1000 Mbps (Fiber with duplex-SC) Gigabit Ethernet NIC. Cables - BN34A, BN34B, or equivalent with SC connectors.
NOTE: Only supported in PCI mode. Supported as a cluster interconnect under OpenVMS only. OpenVMS remedial kit required:
EV7 Tima: DEC-AXPVMS–
VMS731_EV7-
V0100- -4.PCSI
LAN Tima: DEC-AXPVMS-
VMS731_LAN-
V0100-
-4.PCSI
8 8 4 8 8 4 66 MHz 3.3V

3X-DEGXA-SA

  
FDDI Controllers
PCI (32-bit, 33-MHz) to FDDI SAS (MMF/duplex-SC) NIC
Use BN34A, BN34B, or BN34D cables.
8 8 4 8 8 4 33 MHz 3.3/
5V

3X-DEFPA-AC

PCI (32-bit, 33-MHz) to FDDI DAS (MMF/duplex-SC) NIC
Use BN34A, BN34B, or BN34D cables.
8 8 4 8 8 4 33 MHz 3.3/
5V

3X-DEFPA-DC

PCI (32-bit, 33-MHz) to FDDI DAS (UTP/RJ45) NIC
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
8 8 4 8 8 4 33 MHz 3.3/
5V

3X-DEFPA-MC

PCI (32-bit, 33-MHz) to FDDI SAS (UTP/RJ45) NIC
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
8 8 4 8 8 4 33 MHz 3.3/
5V

3X-DEFPA-UC

Multimode fiber optic (MMF) 62.5/125um duplex cable with SC-to-MIC connectors xx = available lengths:
(01, 03, and 10) for 1, 3, and 10 meters
 

BN34D-xx

   
Synchronous/Asynchronous Controllers
PCI (32-bit, 33-MHz) to Dual-port Intelligent Synchronous Communications NIC – Requires at least one (maximum two) BN34x sync cable listed below. - - - 4 4 2 33 MHz 3.3V PCI

3X-PBXDD-AA

PCI (32-bit, 33-MHz) to Quad-port Intelligent Synchronous Communications NIC – Requires at least one (maximum four) BN34x sync cable listed below. - - - 4 4 2 33 MHz 3.3V PCI

3X-PBXDD-AB

 
Synchronous-specific Cables
EIA-530 Single-port cable    

3X-BC34G-06

V.24/EIA-232 Single-port cable  

3X-BC34L-06

V.11/x.21 Single-port cable    

3X-BC33S-06

V.35 Single-port cable    

3X-BC34T-06

    
Asynchronous Communications
PCI (32-bit, 33-MHz) to 4-port Async Communications NIC with DB-25 octopus cable 2 2 2 2 2 2 33 MHz 3.3/
5V

PBXDA-BA

PCI (32-bit, 33-MHz) to 16-port Async Communications Controller and rackmount 16-port distribution box with RJ45 connectors 2 2 2 2 2 2 33 MHz 3.3/
5V

PBXDA-AC

 
Asynchronous Connector Cables
RJ45-to-DB-25 Converter Cable  

CXI01-AC

RJ45-to-DEC MJ11 Converter Cable (8 pack)  

CXI01-AF

   
ATM Adapters
PCI (32-bit, 33-MHz) to 155 Mbps ATM, Copper NIC with RJ45 connector. Use BN25G-xx, or BN26M-xx cables. 8 8 4 8 8 4 33 MHz 3.3/
5V

3X-DAPBA-UA

PCI (32-bit, 33-MHz) to 155 Mbps ATM Fiber NIC with SC connector. Use BN34B-xx cable. 8 8 4 8 8 4 33 MHz 3.3/
5V

3X-DAPBA-FA

 
Ethernet, FDDI, ATM Cables
Multimode fiber optic (MMF) 62.5/125um duplex cable, with SC-to-ST connectors. Xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, and 30 meters  

BN34A-xx

Multimode fiber optic (MMF) 62.5/125um duplex cable, with SC-to-SC connectors. Xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, and 30 meters  

BN34B-xx

Category 5e (4-Unshielded Twisted Pairs / UTP) straight-through cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity. Xx = available lengths: (0B, 0E, 01, 03, 04, 07) for 0.2, 0.5, 1, 3, 4, and 7 meters  

BN25G-xx

Category 5e (4-Twisted Pairs, Screened/ ScTP) straight-through cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity. Xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters  

BN26M-xx

Category 5e (4-Unshielded Twisted Pairs / UTP) Xover cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity. Xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters  

BN24Q-xx

Category 5e (4-Twisted Pairs, Screened / ScTP) Xover cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity. Xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters  

BN28Q-xx

  
Step 12 - Graphics Support
  Maximum # Supported  
  Tru64 UNIX OpenVMS  
 

Per
System
Per External I/O Drawer Per 2P
Building Block Drawer


Per
System
Per
External I/O Drawer
Per 2P
Building Block Drawer
 

 

Speed



PCI/
AGP
Slot
 
3Dlabs Oxygen VX1 32-MB PCI 2D graphics accelerator 2 2 1 1 1 1 66 MHz 3.3V PCI

SN-PBXGF-AB

3Dlabs Oxygen VX1 32-MB AGP 2D graphics accelerator 1 1 1 1 1 1 4X(1) AGP

SN-PBXGF-BC

ATI Radeon 7500 2D AGP graphics accelerator 1 1 1 - - - 4X(1) AGP

3X-PBXGG-AB

1) Only supported in 2X mode.
Maximum graphics adapters per systems, all types - Tru64 UNIX: 2 (1 AGP and 1 PCI or 2 PCI), OpenVMS: 2 (1 AGP and 1 PCI or 2 PCI)
Step 13- MEMORY CHANNEL
Configuring Information
  • Up to two PCI-to-System Area Network adapters (CCMAB-AA) are supported in a single system.
  • Each PCI-to-System Area Network adapter ordered requires the mandatory selection of an I/O Expansion Drawer (see Step 6)
  • Only supported with Tru64 UNIX
  • Two-node clusters can be configured by ordering a CCMAB-AA for each node and one BN39B-04 or BN39B-10 cable, cable connects directly to CCMAB-AA in each node
  • For a two-node cluster that will not need to be rebooted when adding additional members, order one CCMAB-AA adapter and one BN39B-04 or BN39B-10 cable for each node and one CCMHB-AA hub for the cluster
  • For three or four node clusters, order one CCMAB-AA adapter and one BN39B-04 or BN39B-10 cable for each node and one CCMHB-AA hub for the cluster
  • CCMHB-AA includes four CCMLB-AA line cards and supports up to four nodes; expansion up to eight system nodes can be achieved by adding up to four CCMLB-AA line cards
  • If two CCMAB-AAs are configured in each system, a second CCMHB-AA is required.
  • If nodes must be separated by a distance longer than standard copper cables allow the CCMFB option converts the output of the standard CCMAB controller or CCMLB line card to single-mode fiber optic cable. The fiber optic connection may be up to 2,000 meters long between two CCMAB controllers connected in virtual hub mode, or 3,000 meters between a CCMAB controller and a CCMHB hub. (The connection from the CCMHB hub to a second system may also be 3,000 meters.) The CCMFB option requires a second PCI slot in the system from which it draws power only. It is normally connected to the corresponding CCMAB controller with the short BN39B-01 cable. The CCMFB is also used in the CCMHB hub where it occupies a slot normally used by the CCMLB line card, limiting expansion to four radial fiber optic connections.
  • CCMHB-BA hub expansion box provides additional slots for up to eight fiber optic connections. Two standard length single-mode fiber optic cables are available (BN34R-10 and BN34R-31); however, users normally provide this fiber optic connection. Fiber optic connectivity is completely transparent to the systems using it and has no performance impact.
 
Tru64 UNIX (V5.1B)
  • Each system node in the cluster requires a TruCluster software license
    (QL-6BRAE-AA) or TruCluster Plus Software Package (QP-6R9AE-AA)
 
MEMORY CHANNEL Controller/ System Area Network Hub PCI-to-System Area Network Controller, maximum two – 5V/33 MHz

CCMAB-AA

System Area Network Hub with four line cards; includes BN19P-2E power cord for Canada, Japan, and U.S. - for other regions, order appropriate power cord from the following list:

CCMHB-AA

Hub expansion box with no line cards

CCMHB-BA

Expansion line card for CCMHB hub

CCMLB-AA

1-meter cable for CCMAB and CCMHB

BN39B-01

4-meter cable for CCMAB and CCMHB

BN39B-04

10-meter cable for CCMAB and CCMHB

BN39B-10

Copper-to-single mode fiber optic converter - 5V (clock not affected)

CCMFB-AA

Rackmount kit (3U) for CCMHB (Memory Channel Hub II); required for mounting in
11000 Series Cabinets

3X-BA61R-MD

Power cord for rackmount CCMHB hub

BN35S-02

 
Country-specific Power Cords for Standalone MEMORY CHANNEL Hubs Australia, New Zealand

BN19H-2E

Central Europe

BN19C-2E

Denmark

BN19K-2E

Egypt, India

BN19S-2E

Ireland, United Kingdom

BN19A-2E

Israel

BN18L-2E

Italy

BN35M-02

Japan, 2.5-meter, Dentori approved

3X-BN46F-02

Switzerland

BN19E-2E

NOTE: When using MEMORY CHANNEL, refer to the TruCluster QuickSpecs for configuration guidelines and restrictions: http://www.compaq.com/products/
quickspecs/Division/10657.html

The MEMORY CHANNEL controller, CCMAB-AA, must be revision D02 or later.
  
Step 14 - Mouse, Monitors, Power Cords, Keyboards
Keyboard, Mouse, and Video Extension Cable Kit Two 6-foot/1.8-meter USB keyboard/mouse extension cables and one 6-foot/1.8-meter video extension cable (One per system)

CK-GSKVM-AA

 
Video Extension Cable 6-foot/1.8-meter video extension cable

BN39C-02

 
Mouse 3-button mouse - USB

3X-PBQWS-WB

 
Monitors
  • Graphics monitors other than those listed can be used if compatible with SVGA graphics ordered with system
  • A video cable, 6-foot (1.8-meter) length, is included with all variants of monitors
  • Video extension cable required if monitor is located more than 1 meter from server
  • Monitors will ship with, but not be integrated with systems.
 
Carbon/Silver Monitors V7550 17-inch (16-inch viewable image size) flat-faced shadow mask color monitor,
two-tone (carbon/silver), 0.25mm dot pitch, VGA to 1024 x 768 @85 Hz, MPRII/TCO99/Energy Star compliant, Northern Hemisphere with NA power cord, VGA cable
3R-A4002-AA
Same as above, with Euro power cord 3R-A4201-AA
Same as above, APD, no power cord 3R-A4202-AA
Same as above, with PRC power cord, CCIB 3R-A4446-AA
Same as above, Southern Hemisphere, with Australia/New Zealand power cord 3R-A4203-AA
  
P930 19-inch (18-inch viewable image size) auto-scanning color monitor, Diamondtron NF, 0.24-mm aperture grille pitch, VGA to 1600 x 1200 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable 3R-A4215-AA
Same as above, with Euro power cord 3R-A4391-AA
Same as above, Taiwan, with NA power cord 3R-A4392-AA
Same as above, with PRC power cord, CCIB 3R-A4394-AA
Same as above, Southern Hemisphere, 0.25 to 0.27 mm aperture grille pitch, with Australia/New Zealand power cord 3R-A4393-AA
  
P1130 21-inch (19.8-inch viewable image size) FD Trinitron auto-scanning color monitor, 0.24-mm aperture grille pitch, VGA to 1792 x 1344 @85Hz, dual video input, USB Hub, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable 3R-A4216-AA
Same as above, with Euro power cord 3R-A4396-AA
Same as above, Taiwan, no power cord 3R-A4397-AA
Same as above, with PRC power cord, CCIB 3R-A4400-AA
Same as above, Southern Hemisphere, with Australia/New Zealand power cord 3R-A4398-AA
  
Carbon/Silver Flat Panel Monitors TFT1825, 18-inch (18-inch viewable image size) TFT flat panel monitor, 0.28mm pixel pitch, 1600 x 1200 @60Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, one VGA, one DVI-I input connector. NA power cord, VGA and DVI-I cables

3R-A4292-AA

TFT1520, 15-inch (15-inch viewable image size) TFT flat panel monitor, 0.297 mm pixel pitch, 1024 x 768 @75 Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, two video input connectors (one VGA and one DVI-I), NA power cord, VGA and DVI-I cables

3R-A4249-AA

 
Monitor Power Cords North American, 120V, 75-inch BN26J-1K
Australia, New Zealand, 2.5-meter BN19H-2E
Central Europe, 2.5-meter BN19C-2E
Denmark, 2.5-meter BN19K-2E
Egypt, India, South Africa, 2.5-meter BN19S-2E
Israel, 2.5-meter BN18L-2E
Italy, 2.5-meter BN35M-02
Japan, 2.5-meter, Dentori approved 3X-BN46F-02
Switzerland, 2.5-meter BN19E-2E
UK, Ireland, 2.5-meter BN19A-2E
 
Keyboards - USB Keyboard
/Language
Tru64 UNIX OpenVMS
U.S./English keyboard 3R-LKQ50-AA 3X-LK463-A2
Arabic keyboard 3R-LKQ50-BR -
Belgian keyboard 3R-LKQ50-AB 3X-LK463-AB
BHCSY keyboard 3R-LKQ50-AX -
Canadian/English keyboard - 3X-LK463-AQ
Canadian/French keyboard 3R-LKQ50-AC 3X-LK463-AC
Cyrillic keyboard (Russian) 3R-LKQ50-BT 3X-LK463-BT
Czech keyboard 3R-LKQ50-BV 3X-LK463-BV
Danish keyboard 3R-LKQ50-AD 3X-LK463-AD
Dutch keyboard 3R-LKQ50-AH 3X-LK463-AH
Finnish keyboard - 3X-LK463-AF
French keyboard 3R-LKQ50-AP 3X-LK463-AP
German keyboard 3R-LKQ50-AG 3X-LK463-AG
Greek keyboard 3R-LKQ50-BH 3X-LK463-BH
Hebrew keyboard 3R-LKQ50-AT 3X-LK463-AT
Hungarian keyboard 3R-LKQ50-BQ 3X-LK463-BQ
International keyboard 3R-LKQ50-BA -
Italian keyboard 3R-LKQ50-AI 3X-LK463-AI
Japanese keyboard 3R-LKQ50-AJ -
Korean keyboard 3R-LKQ50-BK -
Latin-American keyboard 3R-LKQ50-AR -
Norwegian keyboard 3R-LKQ50-AN 3X-LK463-AN
Polish keyboard 3R-LKQ50-BP 3X-LK463-BP
Portuguese keyboard 3R-LKQ50-AV 3X-LK463-AV
Romanian keyboard - 3X-LK463-BL
Simplified Chinese keyboard 3R-LKQ50-CV -
Spanish keyboard 3R-LKQ50-AS 3X-LK463-AS
Swedish keyboard 3R-LKQ50-AM 3X-LK463-AM
Swiss/French keyboard 3R-LKQ50-AK 3X-LK463-AK
Swiss/German keyboard - 3X-LK463-AL
Traditional Chinese keyboard 3R-LKQ50-BI -
Thai keyboard 3R-LKQ50-CB -
Turkish keyboard 3R-LKQ50-BU 3X-LK463-BU
Turkish/F keyboard - 3X-LK463-BW
UK keyboard 3R-LKQ50-AE -
Yugoslavian keyboard - 3X-LK463-BY
  
Rackmount Keyboard/Drawer and Keyboard/Monitor Options PS2 to USB Converter - allows for connection of a PS2 keyboard and/or mouse to an AlphaServer ES80 System 3R-A4495-AA
HP Rackmount Flat Panel Monitor 3R-A4220-AA
Integrated Keyboard and Drawers
Integrated Keyboard and Drawer (1U), North America 3R-A4404-AA
Integrated Keyboard and Drawer (1U), International 3R-A4405-AA
Integrated Keyboard and Monitor (TFT5600RKM
Integrated Keyboard and Monitor, North America 3R-A3496-AA
Integrated Keyboard and Monitor, France 3R-A3709-AA
Integrated Keyboard and Monitor, Germany 3R-A3708-AA
Integrated Keyboard and Monitor, International 3R-A3498-AA
Integrated Keyboard and Monitor, Spain 3R-A3710-AA
Integrated Keyboard and Monitor, United Kingdom 3R-A3706-AA
NOTE: Integrated Keyboard and Drawer and Integrated Keyboard and Monitor require one Keyboard and Mouse Adapter for USB (3R-A4495-AA)
  
Step 15 - System Software
Tru64 UNIX
  • Media and documentation required for first system on site
  • Software Processor Code = G
  • Tru64 UNIX base systems include pre-installed software, Base license, Unlimited User license, Server Extension license, Internet Express, and Secure Web Server
Tru64 UNIX media and online documentation on CD-ROM

QA-6ADAA-H8

Tru64 UNIX full hard copy documentation

QA-6ADAA-GZ

TruCluster Plus Software Package with licenses for TruCluster Server, Logical Storage Manager and AdvFS Utilities

QP-6R9AG-AA

TruCluster Server license

QL-6BRAG-AA

Logical Storage Manager license

QL-2GVAG-AA

AdvFS Utilities license

QL-0EGAG-AA

Advanced Server for Tru64 UNIX, 25 client concurrent use license

QL-5U29M-3D

Advanced Server for Tru64 UNIX, 50 client concurrent use license

QL-5U29M-3E

Advanced Server for Tru64 UNIX, 100 client concurrent use license

QL-5U29M-3F

Advanced Server for Tru64 UNIX, 250 client concurrent use license

QL-5U29M-3G

Advanced Server for Tru64 UNIX, 500 client concurrent use license

QL-5U29M-3H

Layered products media and documentation for Tru64 UNIX on CD-ROM

QA-054AA-H8

DECnet/OSI end-system function license for Tru64 UNIX

QL-MTJAG-AA

DECnet/OSI extended license for Tru64 UNIX

QL-MTKAG-AA

 
OpenVMS
  • Media and documentation required for first system on site
  • Software Processor Code = G
  • AlphaServer ES80 OpenVMS systems include Base license with System Manager license and Enterprise Integration Server Package for OpenVMS -- OpenVMS OS media on CD-ROM
  • Enterprise Integration Package includes licenses for TCP/IP Services for OpenVMS, DECwindows Motif for OpenVMS Alpha, DECnet-Plus for OpenVMS Alpha End System, Archive/Backup System for OpenVMS Management Tools, Archive/Backup Agent for Windows NT?/sup>, Office Server for OpenVMS, Office Server Client Access, PATHWORKS 32, PATHWORKS for OpenVMS and Advanced Server.
  • OpenVMS Concurrent Use licenses provide the right to interactively use the operating system by the specified number of concurrent users on a designated OpenVMS system. OpenVMS Concurrent Use licenses can be moved from one system to another at user discretion and can be shared in a mixed OpenVMS VAX and OpenVMS Alpha cluster
  • OpenVMS Traditional Unlimited Use license is system specific and can only be used on one single system at a time. It cannot be shared between systems or in an OpenVMS VAX or OpenVMS Alpha Cluster
Concurrent Use 1-user license

QL-MT3AA-3B

Concurrent Use 2-user license

QL-MT3AA-3C

Concurrent Use 4-user license

QL-MT3AA-3D

Concurrent Use 8-user license

QL-MT3AA-3E

Concurrent Use 16-user license

QL-MT3AA-3F

Concurrent Use 32-user license

QL-MT3AA-3G

Concurrent Use 64-user license

QL-MT3AA-3H

Concurrent Use 128-user license

QL-MT3AA-3J

Concurrent Use 256-user license

QL-MT3AA-3K

Traditional unlimited-user license

QL-MT2AG-AA

OpenVMS media and online documentation on CD-ROM

QA-MT1AA-H8

OpenVMS hard copy documentation

QA-001AA-GZ

OpenVMS base hard copy documentation

QA-09SAA-GZ

OpenVMS Alpha Software Products Library Package: Layered products media and documentation for OpenVMS on CD0ROM, includes media and documentation for all products licensed in the Enterprise Integration Package.

QA-03XAA-H8

DECnet-Plus/DECnet extended function license for OpenVMS

QL-MTGAG-AA

DECnet-Plus/DECnet end-system to extended function upgrade license for OpenVMS

QL-MTHAG-AA

Cluster License for OpenVMS Alpha

QL-MUZAG-AA

OpenVMS Volume Shadowing license

QL-2A1AG-AA

A more complete software list can be found at: http://www.openvms.compaq.com/swcat/index.html
 
Step 16 - Hardware and Software Support Services
  • Select one of the optional CarePaq Priority Service Packages described below that best supports the customer’s operational requirements for system availability.
CarePaq Priority Services
  • CarePaq Priority Services are available for AlphaServer systems running Tru64 UNIX or OpenVMS operating systems. Priority Services are designed for the growing number of customers who need support beyond the basic warranty. Five packages are offered - Priority, Priority 24, Priority Silver, Priority Gold, and Priority Executive with coverage for both Principal servers systems and SSPs (Subsequent System Packages) - that meet a full range of customer support requirements.
 
Program Features – Principal Server
Priority
  • 9x5 HW/SW support
  • 4-hour response on-site hardware support
  • 2-hour response for Bronze software support
  • License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
 
Priority 24
  • 24x7 HW/SW support
  • Named HW engineer
  • 4-hour response on-site hardware support
  • 2-hour response for Bronze software support
  • License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
  • Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their layered products. (Some layered products on Consolidated Media Update Distribution can be ordered separately.)
 
Priority Silver
  • 24x7 HW Support. Named Engineer, 4-hour response
  • 24x7 Silver SW Support - Named Account Rep, 1-hour response Monday – Friday, 8AM-5PM local time; 2-hour response remaining hours
  • License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
  • Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their layered products. (Some layered products on Consolidated Media Update Distribution can be ordered separately.)
  • Technical newsletter and SW activity review
  • Proactive Patch Notification
  • One (1) System Healthcheck per year
 
Priority Gold
  • 24x7 HW support with Named Engineer, 4-hour response for on-site support
  • 24x7 Gold SW support - Named Account Rep
  • 30-minute callback (critical); 1-hour callback (non-critical)
  • License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
  • Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their layered products. (Some layered products on Consolidated Media Update Distribution can be ordered separately.)
  • Technical newsletter, SW activity review and 10 hours Upgrade impact planning
  • Proactive Revision Management
  • Two (2) System Healthchecks per year
  • Mandatory pre-qualification required
 
Priority Gold Executive
  • 24x7 HW support with Named Engineer, two-hour response for on-site support
  • 24x7 Gold SW support - Named Account Rep
  • 30-minute callback (critical); one-hour callback (non-critical)
  • License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
  • Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their layered products. (Some layered products on Consolidated Media Update Distribution can be ordered separately.)
  • Technical newsletter, SW activity review and 10 hours Upgrade impact planning
  • Proactive Revision Management
  • Two (2) System Healthchecks per year
  • Customer site must be within 25 miles of an HP service location
  • Mandatory pre-qualification required
 
Program Features – Additional Services
SSPs (Subsequent System Packages)
  • For Priority, Priority 24, Priority Silver, Priority Gold, and Priority Gold Executive
  • HW Support at same level as corresponding package for Principal server
  • License Subscription: HP O/S (where applicable)
  • Telephone support through Principal server covered by full support package
 
Installation
  • Pre-installation review
  • Unpacking of equipment
  • Assemble and test
  • Basic product usage info
  • No software installation added
 
Installation and Startup HP O/S
  • Pre-installation review
  • Unpacking of equipment
  • Assemble and test
  • Basic product usage info
  • Install operating systems
  • Product configuration
  • Print and network access
  • Orientation
 
Model/CarePaq
Priority Service
Principal Server
1 year
Principal Server
3 years
Subsequent Systems
1 year
Subsequent Systems
3 years
AlphaServer ES80 Model 2 and Model 4
Priority FP-F01HA-12 FP-F01HA-36 FP-F21HA-12 FP-F21HA-36
Priority 24 FP-F02HA-12 FP-F02HA-36 FP-F22HA-12 FP-F22HA-36
Priority Silver FP-F04HA-12 FP-F04HA-36 FP-F24HA-12 FP-F24HA-36
Priority Gold FP-F08HA-12 FP-F08HA-36 FP-F28HA-12 FP-F28HA-36
Priority Gold Exec. FP-F09HA-12 FP-F09HA-36 FP-F29HA-12 FP-F29HA-36
Installation FP-FINST-HA FP-FINST-HA FP-FINST-HA FP-FINST-HA
Installation & Startup FP-FSTAR-HA FP-FSTAR-HA FP-FSTAR-HA FP-FSTAR-HA
         
AlphaServer ES80 Model 6 and Model 8
Priority FP-F01HB-12 FP-F01HB-36 FP-F21HB-12 FP-F21HB-36
Priority 24 FP-F02HB-12 FP-F02HB-36 FP-F22HB-12 FP-F22HB-36
Priority Silver FP-F04HB-12 FP-F04HB-36 FP-F24HB-12 FP-F24HB-36
Priority Gold FP-F08HB-12 FP-F08HB-36 FP-F28HB-12 FP-F28HB-36
Priority Gold Exec. FP-F09HB-12 FP-F09HB-36 FP-F29HB-12 FP-F29HB-36
Installation FP-FINST-HB FP-FINST-HB FP-FINST-HB FP-FINST-HB
Installation & Startup FP-FSTAR-HB FP-FSTAR-HB FP-FSTAR-HB FP-FSTAR-HB
         
AlphaServer ES80 Expansion from Model 2 or 4 to Model 6 or 8
Priority FP-F01HU-12 FP-F01HU-36 FP-F21HU-12 FP-F21HU-36
Priority 24 FP-F02HU-12 FP-F02HU-36 FP-F22HU-12 FP-F22HU-36
Priority Silver FP-F04HU-12 FP-F04HU-36 FP-F24HU-12 FP-F24HU-36
Priority Gold FP-F08HU-12 FP-F08HU-36 FP-F28HU-12 FP-F28HU-36
Priority Gold Exec. FP-F09HU-12 FP-F09HU-36 FP-F29HU-12 FP-F29HU-36
Installation FP-FINST-HU FP-FINST-HU FP-FINST-HU FP-FINST-HU
Installation & Startup FP-FSTAR-HU FP-FSTAR-HU FP-FSTAR-HU FP-FSTAR-HU
         
NOTES:
  • AlphaServer ES80 systems include one-year parts and labor warranty with 5x9, on-site Next Business Day response.
  • Priority Services include support for new HP branded hardware options internal to the AlphaServer enclosure plus a monitor (17-inch or less excluding flat panel models).
  • External storage devices/cabinets carry their own level of warranty and should be quoted separately for uplifted warranty services.
  • Five-year CarePaq Priority Service is available upon request. To quote five-year service, change the last two part number digits from 12 or 36 to 60.
  • In addition to the CarePaq Priority Services, uplifted warranty. Supplemental Services are available for separate hardware and software support. For more information on Hardware and Software Supplemental Services and other HP service options available for AlphaServers, please consult your Sales Account Manager or visit: http://www.hp.com/services/

NOTES: This website is available in English only.

contents
 Overview   Standard Features   SystemsOptions   Options   Upgrades   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) Upgrades
Step 17 – AlphaServer ES80 System Hardware Upgrades
AlphaServer ES80 systems can be field upgradeable with the following options
  • AlphaServer ES80 Model 2 to AlphaServer ES80 Model 4 Upgrade
  • AlphaServer ES80 Model 4 to AlphaServer ES80 Model 6 Upgrade
  • AlphaServer ES80 Model 6 to AlphaServer ES80 Model 8 Upgrade
    
System Upgrades
  • AlphaServer ES80 upgraded by ordering the appropriate 3X-BA60B-xx upgrade kit
System expansion hardware to upgrade an AlphaServer ES80 Model 2 to an AlphaServer ES80 Model 4. Includes one System Building Block Drawer with two power supplies; one rackmount slide kit; associated inter-processor cabling. (CPU Building Block Module and memory options required. See Steps 3 and 4.) 3X-BA60B-AB
System expansion hardware to upgrade an AlphaServer ES80 Model 4 to an AlphaServer ES80 Model 6. Includes one System Building Block Drawer with two power supplies; one rackmount slide kit; associated inter-processor cabling. (CPU Building Block Module and memory options required. See Steps 3 and 4.) 3X-BA60B-AC
System expansion hardware to upgrade an AlphaServer ES80 Model 6 to an AlphaServer ES80 Model 8. Includes one System Building Block Drawer with two power supplies; one rackmount slide kit; associated inter-processor cabling. (CPU Building Block Module and memory options required. See Steps 3 and 4.) 3X-BA60B-AD
contents
 Overview   Standard Features   SystemsOptions   Options   Upgrades   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) TechSpecs
Power Requirements       
ES80 System US/Canada Japan Europe
PDU Part Number 3X-H7606-AA 3X-H7606-AA 3X-H7606-AB
Nominal voltage(s) 208 200 380/415
Rated Current 24A 24A 24A
Kva Model 6, 2 I/O Expansion Drawers,
5 StorageWorks Shelves
6.349 6.349 6.349
Kva Model 8, 2 I/O Expansion Drawers,
3 StorageWorks Shelves
5.932 5.932 5.932
Frequency range 50-60 Hz 50- 60 Hz 50-60 Hz
Phases 3W+N+G 3W+N+G 3W+N+G
Number of Auxiliary PDUs required 0 0 0
Rating 10/7A per cord 10/7A per cord 10/7A per cord
Receptacle (site) L21-30P, Hubbell 2811 L21-30P, Hubbell 2811 Hubbell 532P6W
Physical Characteristics - ES80 System
Dimensions (H x W x D) 79 x 24 x 47 in (200 x 60 120 cm) (41U Rack)
6 x 17.5 x 34 in (15 x 44.5 x 86 cm) (Drawer)
Shipping Dimensions 86 x 32 x 48 in (217 x 92.5 142 cm) (41U Rack)
  
    ES80 Model 2 – 1 I/O Expansion Drawer,
1 StorageWorks Shelf,
41U Rack
ES80 Model 4 – 2 I/O Expansion Drawers,
1 StorageWorks Shelf,
41U Rack
ES80 Model 6 – 3 I/O Expansion Drawers,
1 StorageWorks Shelf,
41U Rack
ES80 Model 8 – 4 I/O Expansion Drawers,
1 StorageWorks Shelf, 41U Rack
Weight Maximum Configuration 706 lb (320 kg) 910 lb (412 kg) 1104 lb (500 kg) 1304 lb (591 kg)
Shipping Weight - Maximum Configuration - cardboard outside wrap not included 883 lb (400 kg) 1088 lb (493 kg) 1282 lb (581 kg) 1483 lb (672 kg)
Heat dissipation ES80 Model 2 – 1 I/O Expansion Drawer,
1 StorageWorks Shelf,
41U Rack
ES80 Model 4 – 2 I/O Expansion Drawers,
1 StorageWorks Shelf,
41U Rack
ES80 Model 6 – 3 I/O Expansion Drawers,
1 StorageWorks Shelf,
41U Rack
ES80 Model 8 – 4 I/O Expansion Drawers,
1 StorageWorks Shelf, 41U Rack
Minimally configured system (1 PCI option,
1 disk, 8 memory RDRAMs) I/O Expansion Drawer, no storage shelf
894 W 1788 W 2682 W 3576 W
Btu/hr 3051 6102 9153 12204
Airflow@20C DT, cfm 336 617 1063 1399
Fully configured system (3 PCI, 1 AGP,
2 disks, 20 RDRAMs) ES80, I/O Expansion Drawer, one StorageWorks Shelf
1930 W 3860 W 4596 W 5928 W
Btu/hr 6587 13174 15686 20230
Airflow@20C DT, cfm 201 348 1063 1399
  
Clearances – All Models Operating Service
Front 32 in (81 cm) 32 in (81 cm)
Rear 44 in (111 cm) 44 in (111 cm)
Left Side None None
Right Side None None
  
Environmental Operating Non-Operating
Temperature 50?/font> to 104?/font> F
(10?/font> to 40?/font> C)
–40?/font> to 151?/font> F (–40?/font> to 66?/font> C)
Humidity 10% to 90% 10% to 95%, Storage (60 days) 115?/font> F/16?/font> C
Altitude 10,000 ft (3,050 m)
NOTE: Maximum operating temperature at sea level; reduce by 1.8?/font> F (1?/font> C) for each 2,000 ft (600 m) above sea level
40,000 ft (12,200 m)
Vibration 10 to 500 Hz 0.1G peak 1.03 Grms 5-300 Hz
Shock 5G 30ms, half sine
Acoustics (Declared values per ISO 9296 and ISO 7779) Idle/Operating (Bystander pos.)
Part Description LwAd, B LpAm, dBA
ES80 Model 2 1 x 2P SBB Drawer 6.6 48
ES80 Model 4 2 x 2P SBB Drawer 6.9 51
ES80 Model 6 3 x 2P SBB Drawer 7.1 53
ES80 Model 8 4 x 2P SBB Drawer 7.2 54
ES80 System Building Block Drawer 6.6 48
3X-BA70A-BA I/O Expansion Drawer 7.1 51
DS-SL13R-xx StorageWorks Shelf 6.9 53
NOTE: Current values for specific configurations are available. 1 B = 10 dBA  
Regulatory - Agency approvals UL: Listed to UL 60950; cUL: Listed to CAN/CSA-C22.2 No.6950-00
CB Report to IEC 950:1991+A1: 1992 + A2:1993 + A3: 1995 + A4:1996
CB Report to EN60950 (1992) with Amdts. 1, 2, 3, 4 and 11
FCC: Part 15.B Class A
IC ICES-003 Class A
CE: EN55022: 1998, EN55024: 1998, EN61000-3-2: 1995, EN61000-3-3: 1995
VCCI: V-3/02.04 Class A
BSMI: CNS 13438 Class A
C-Tick:AS/NZS 3548:1995 Class A

?2003 Hewlett-Packard Company

Hewlett-Packard, the Hewlett-Packard logo, AlphaServer, OpenVMS, StorageWorks, CarePaq, Tru64, and TruCluster are trademarks of Hewlett-Packard Company in the U.S. and/or other countries. UNIX is a registered trademark or trademark of The Open Group in the U.S. and/or other countries. All other product names mentioned herein may be trademarks of their respective companies.

Hewlett-Packard shall not be liable for technical or editorial errors or omissions contained herein. The information is provided ?/font> as is?/font> without warranty of any kind and is subject to change without notice. The warranties for Hewlett-Packard products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty.


   DA-11031 - U.S. - Version 8 - March 7, 2008