Options
| Step 4- Memory -
Mandatory |
| Memory Configuration Guidelines |
Memory options should be selected in the
context of the applications sensitivity to memory bandwidth and future memory
capacity expansion. This will determine the number of memory options to order. The total
capacity required will determine the size of the options to be ordered.
- Mandatory
selection of memory option required
- ES47 Model 2 systems require a minimum of one memory option
- ES47 Model 2 systems ordered with one I/O Expansion Drawer requires a minimum of two
memory options
- ES47 Model 4 systems require a minimum of two memory options
- ES47 Model 4 systems ordered with one I/O Expansion Drawer requires a minimum of three
memory options
- ES47 Model 4 systems ordered with two I/O Expansion Drawers require a minimum of four
memory options
- Each ES47 Model 2 system supports up to four memory options (four RIMMs each) and up to
four memory RAID options
(one RIMM each) for a total of 20 RIMMs.
- ES47 Model 4 system supports up to eight memory options and up to eight memory RAID
options for a total of 40 RIMMs.
- If an I/O Expansion Drawer is ordered (see Step 6), both CPUs in the CPU Building Block
Module connected to the I/O Drawer must contain memory in at least one memory
controller.
- Each CPU has two memory controllers Each memory controller can support four RIMMs
(one memory option) and a fifth
RIMM slot for redundancy (RAID option).
- If populated, the two memory controllers per CPU must contain the same size
RIMMs.
- Order one RAID option (one RIMM) per memory option if desired.
- If RAID memory option is selected, the number of RAID options selected must equal
the number of memory options selected.
The following examples illustrate different ways of configuring an ES47 Model 4 system
with a total of 4 GB (1 GB per CPU) |
| |
CPU
Building Block Module 1 |
CPU
Building Block Module 2 |
| Memory Option |
CPU
1 |
CPU
2 |
CPU
3 |
CPU
4 |
| Controller 1 |
Controller 2 |
Controller 1 |
Controller 2 |
Controller 1 |
Controller 2 |
Controller 1 |
Controller 2 |
| 3X-MS7AB-AA (4x128MB) |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
| 3X-MS7AB-BA (4x256MB) |
1 |
- |
1 |
- |
1 |
- |
1 |
- |
| 3X-MS7AB-CA (4x512MB) |
1 |
- |
- |
- |
1 |
- |
- |
- |
| |
| Memory Application Examples |
| Configuring memory is a
compromise between cost, total memory capacity, and memory bandwidth requirements. The
behavior of the application must be used to define the most-desired configuration. Some
applications are sensitive to memory capacity while some are sensitive to memory
bandwidth. If actual application measurements are not available, the following may be used
as guidelines: |
- Large memory (VLM) applications, in which large amounts of memory can substantially
reduce I/O, may be optimized for total memory capacity and future capacity growth. In VLM
applications, the right balance might be one memory option per CPU. (Case B)
- Typical commercial applications, such as transaction processing (OLTP) and multi-user
timesharing, usually operate efficiently from cache and may not be materially affected by
memory bandwidth. Memory configuration is a balance between memory bandwidth and future
capacity growth. It is advisable to match the number of memory options to the number of
CPUs. (Case B)
- Data mining can benefit from additional memory bandwidth. In these cases, configure four
memory options, two per CPU. (Case A)
The most demanding high-performance technical applications (HPTC) achieve a performance
level that is directly proportional to memory bandwidth. In these cases, configure four
memory options, two per CPU. (Case A) |
|
512-MB RDRAM
Memory (4x128) Option |
3X-MS7AB-AA |
|
512-MB RDRAM
Memory (1x128) RAID Option |
3X-MS7AB-AC |
|
1-GB RDRAM Memory
(4x256) Option |
3X-MS7AB-BA |
|
1-GB RDRAM Memory
(1x256) RAID Option |
3X-MS7AB-BC |
|
2-GB RDRAM Memory (4x512)
Option |
3X-MS7AB-CA |
|
2-GB RDRAM Memory (1x512) RAID
Option |
3X-MS7AB-CC |
| |
| Step 5 -
Select System Disk |
- Mandatory
selection of at least one system disk drive is required for each ES47
system ordered. NOTE: Integrated
Ultra3 SCSI controller and cabling included.
- AlphaServer ES47 Model 2 systems support up to two internal hard disk drives
- AlphaServer ES47 Model 4 systems support up to four internal
hard disk drives
|
|
36.4-GB Ultra320 SCSI 10,000 rpm
1-inch Universal disk drive |
3R-A3838-AA |
|
72.8-GB Ultra320 SCSI 10,000 rpm
1-inch Universal disk drive |
3R-A3839-AA |
|
146-GB Ultra320 SCSI 10,000 rpm
1-inch Universal disk drive |
3R-A3841-AA |
|
18.2-GB Ultra320 SCSI 15,000 rpm
1-inch Universal disk drive |
3R-A3848-AA |
|
36.4-GB Ultra320 SCSI 15,000 rpm
1-inch Universal disk drive |
3R-A3849-AA |
|
72.8-GB Ultra320 SCSI 15,000 rpm
1-inch Universal disk drive |
3R-A3851-AA |
| I/O Configuration Guidelines: |
- Each System Building Block Drawer in an AlphaServer ES47
system supports six total slots spread over three buses (ports). The following details the
internal I/O slots:
|
| Port # |
Slot # |
Maximum Bus Speed |
Signal Voltage |
Number of Devices Supported |
| 0 |
1 |
133 MHz |
3.3 V |
1 133 MHz or 66 MHz PCI-X
or
1 66 or 33 MHz PCI |
| 1 |
1 |
66 MHz |
3.3 V |
2 66 MHz PCI-X
or
2 66 MHz PCI or
4 33 MHz PCI
|
| 2 |
66 MHz |
3.3 V |
| 3 |
66 MHz |
3.3 V |
| 4 |
66 MHz |
3.3 V |
| 3 |
1 |
2X AGP |
1.5 V |
1 1X or 2X AGP |
| NOTE: ES47 Model 2
Base Systems contain one System Building Block Drawer; ES47 Model 4 Base Systems contain
two System Building Block Drawers |
- AlphaServer ES47 Model 2 system supports one optional I/O Expansion Drawer
|
- AlphaServer ES47 Model 4 systems support up to two optional I/O Expansion Drawers
|
- Each I/O Expansion Drawer supports 12 total slots spread over four buses (ports)
|
| |
| The following chart details the External I/O
Expansion Drawer slots: |
| Port # |
Slot # |
Maximum Bus Speed |
Signal Voltage |
Number of Devices Supported |
| 0 |
1 |
33 MHz |
3.3V |
1 33 MHz PCI |
| 2 |
33 MHz |
5.0V |
1 CCMAB-AA
(Memory Channel) or
1 CIPCA-BA or
2 3X- KZPBA-CC
(NOTE: No mixing of options within 5V
slots) |
| 3 |
33 MHz |
5.0V |
| 1 |
1 |
133 MHz |
3.3V |
2 66 or 33 MHz
PCI or
2 66 MHz PCI-X or
1(1) 133 MHz PCI-X |
| 2 |
133 MHz |
3.3V |
| 2 |
1 |
66 MHz |
3.3V |
6
33 MHz PCI or
3(2) 66 MHz PCI or
2 66 MHz PCI- X |
| 2 |
66 MHz |
3.3V |
| 3 |
66 MHz |
3.3V |
| 4 |
66 MHz |
3.3V |
| 5 |
66 MHz |
3.3V |
| 6 |
66 MHz |
3.3V |
| 3 |
1 |
2X AGP |
1.5V |
1 1X or 2X AGP |
NOTE: (1)
Two 133 MHz PCI-X devices are supported in Port 1, slots 1 and 2; they will however
operate at 100 MHz.
(2) Five 66 MHz PCI devices are supported in Port 2, slots 1-5; they will however operate
at 50 MHz. |
Modules designed for 5.0v
signaling and 33-MHz bus speed can only operate in Port 0 slots 2 and 3
(reserved for Memory Channel or CIPCA)
Modules designed for 3.3v signaling and 66-MHz bus speed can not operate in Port 0
slots 2 and 3 |
| Universal PCI modules capable of
operating at 66 MHz will operate at 33 MHz when placed in a 33-MHz slot |
| |
| Step 6 - I/O
System Expansion (Optional) |
| I/O Expansion Drawer |
- Model 2 systems support one I/O Expansion Drawer; Model 4 systems support up to two
|
|
- I/O Expansion Drawers contain 11 PCI/PCI-X slots and one AGP 2X slot; an N+1 redundant
power system
|
|
- I/O Expansion Drawer required for memory channel network adapter or CIPCA (PCI-CI)
adapter
|
|
I/O Expansion Drawer
Factory Installed |
3X-BA70A-BA |
|
I/O Expansion Drawer Field
Installable |
3X-BA70A-ZB |
|
I/O cable for connection between
System Building Block Drawer and I/O Expansion Drawer shelves mounted in system power
cabinet; one mandatory per each I/O Expansion Drawer ordered |
3X-BNPCB-02 |
| |
| Step 7 -
11000 Series Cabinets |
- 11000 Series Cabinet enclosures support ES47 System Building Block Drawers, I/O
Expansion Drawers, and StorageWorks shelves (see configuration chart below)
|
- All ES47 Base Systems include all necessary hardware to mount the systems in an
11000-Series cabinet
|
- All ES47 Base Systems include all required internal IEC/IEC power cords
|
- 11000 Series Cabinets require the mandatory selection of the following items:
- 11000 Series Cabinets: 3X-H9A45-ZD (41U) or 3X-H9A40-ZA (34U)
- Three-phase Power Distribution Unit(s): Choice of 3X-H7606-AA (North America 120/208V)
or 3X-H7606-AB (International 380/415V)
- Factory integration: YS-ASCAA-AA
|
- 3X-H9A45-ZD/3X-H9A40-ZA includes one Cable/DSL Hub
|
| NOTE: For
configurations beyond those listed in the following chart, or for mounting ES47 systems in
non-11000 series cabinet, contact CustomSystems. |
Number
of systems for mounting in 3X-H9A45-ZD (41U) Cabinet Using one 30A
three-phase PDU (3X-H7606-AA/AB) |
Number
of I/O Drawers and/or DS43XX StorageWorks
Shelves for-mounting in
3X-H9A45-ZD (41U) Cabinet |
| |
ES47 Model 2 |
|
ES47 Model 4 |
I/O Expansion
Drawers |
Max. DS43xx
SW Shelves |
Total Us Consumed |
3X-H9A45-ZD Cabinet |
Extra
Us |
| Size in U's |
4U |
|
8U |
4U |
3U |
|
41U |
|
| Configuration #1 |
1 |
|
- |
0 |
10 |
40 |
41 |
1 |
| Configuration #2 |
1 |
|
- |
1 |
9 |
41 |
41 |
0 |
| Configuration #3 |
2 |
or |
1 |
0 |
9 |
41 |
41 |
0 |
| Configuration #4 |
2 |
or |
1 |
1 |
7 |
39 |
41 |
2 |
| Configuration #5 |
2 |
or |
1 |
2 |
6 |
40 |
41 |
1 |
| Configuration #6 |
3 |
|
- |
0 |
7 |
39 |
41 |
2 |
| Configuration #7 |
3 |
|
- |
1 |
6 |
40 |
41 |
1 |
| Configuration #8 |
3 |
|
- |
2 |
5 |
41 |
41 |
0 |
| Configuration #9 |
3 |
|
- |
3 |
3 |
39 |
41 |
2 |
| Configuration #10 |
4 |
or |
2 |
0 |
6 |
40 |
41 |
1 |
| Configuration #11 |
4 |
or |
2 |
1 |
5 |
41 |
41 |
0 |
| Configuration #12 |
4 |
or |
2 |
2 |
3 |
39 |
41 |
2 |
| Configuration #13 |
4 |
|
- |
3 |
2 |
40 |
41 |
1 |
| Configuration #14 |
4 |
|
- |
4 |
1 |
41 |
41 |
0 |
NOTE: For
redundancy on any configuration listed above, order second PDU (3X-H7606-AA/AB).
Each 3X-H9A45-ZD/3X-H9A40-ZA cabinet includes one Cable/DSL Hub. In order to fully utilize
the Server Management capabilities,(i.e., running AMS or AMU software), each Model 2 or
Model 4 system ordered must have a Cable/DSL Hub.
The Hub included with the cabinet supports the 1st system (Model 2 or Model 4) mounted in
the cabinet.
An additional Hub is required for each additional system (Model 2 or Model 4) mounted in
the cabinet.
For serial console or VGA operation of the system, the Cable/DSL Hub is not required. |
Number of systems
for mounting in
3X-H9A40-ZA (34U) Cabinet Using one 30A three-phase PDU (3X-H7606-AA/AB) |
Number of I/O
Drawers and/or DS43XX StorageWorks Shelves for mounting in 3X-H9A40-ZA (34U) Cabinet |
| |
ES47 Model 2 |
|
ES47 Model 4 |
I/O Expansion
Drawers |
Max. DS43xx
SW Shelves |
Total Us Consumed |
3X-H9A40-ZA Cabinet |
Extra
Us |
| Size in U's |
4U |
|
8U |
4U |
3U |
|
34U |
|
| Configuration #1 |
1 |
|
- |
0 |
8 |
34 |
34 |
0 |
| Configuration #2 |
1 |
|
- |
1 |
6 |
32 |
34 |
2 |
| Configuration #3 |
2 |
or |
1 |
0 |
6 |
32 |
34 |
2 |
| Configuration #4 |
2 |
or |
1 |
1 |
5 |
33 |
34 |
1 |
| Configuration #5 |
2 |
or |
1 |
2 |
4 |
34 |
34 |
0 |
| Configuration #6 |
3 |
|
- |
0 |
5 |
33 |
34 |
1 |
| Configuration #7 |
3 |
|
- |
1 |
4 |
34 |
34 |
0 |
| Configuration #8 |
3 |
|
- |
2 |
2 |
32 |
34 |
2 |
| Configuration #9 |
3 |
|
- |
3 |
1 |
33 |
34 |
1 |
| Configuration #10 |
4 |
or |
2 |
0 |
4 |
34 |
34 |
0 |
| Configuration #11 |
4 |
or |
2 |
1 |
2 |
32 |
34 |
2 |
| Configuration #12 |
4 |
or |
2 |
2 |
1 |
33 |
34 |
1 |
| Configuration #13 |
4 |
|
- |
3 |
0 |
34 |
34 |
0 |
| Configuration #14 |
4 |
|
- |
3 |
0 |
34 |
34 |
0 |
NOTE: For
redundancy on any configuration listed above, order second PDU (3X-H7606-AA/AB).
Each 3X-H9A45-ZD/3X-H9A40-ZA cabinet includes one Cable/DSL Hub. In order to fully utilize
the Server Management capabilities, (i.e., running AMS or AMU softare) each Model 2 or
Model 4 system ordered must have a Cable/DSL Hub.
The Hub included with the cabinet supports the 1st system (Model 2 or Model 4) mounted in
the cabinet.
An additional Hub is required for each additional system (Model 2 or Model 4) mounted in
the cabinet.
For serial console or VGA operation of the system, the Cable/DSL Hub is not required. |
| |
| 11000-Series
Cabinets |
| 11000-Series Cabinets |
41U 11000-Series
Cabinet |
3X-H9A45-ZD |
|
34U 11000-Series
Cabinet |
3X-H9A40-ZA |
Power
Distribution Unit Mandatory
(if cabinet is ordered) |
120/208V Y or 200V,
30A NEMA L21-30P plug 3 x C19 outlets plus 24 x C13 outlets |
3X-H7606-AA |
| 380/415V Y, IEC 309
32A 6h/230/400~ plug 3 x C19 outlets plus 24 x C13 outlets |
3X-H7606-AB |
Factory Integration
Mandatory
(if cabinet is ordered) |
Factory Integration
of systems and storage devices assembled and configured in cabinet enclosure in predefined
locations |
YS-ASCAA-AA |
| Cable/DSL Hub - Optional |
Cable/DSL 8-port Hub
only required when more than one Model 2 or Model 4 is mounted in the same cabinet
and the Server Management capabilities need to be fully utilized. |
3X-DGHUB-AA |
| |
| Step 8-
Storage Adapters/Controllers |
| |
Maximum
# Supported |
Speed |
PCI/
PCI-
X
Slot |
|
| |
Tru64
UNIX |
OpenVMS |
| |
Per
System |
Per
External I/O
Drawer |
Per 2P Building Block Drawer |
Per
System |
Per External I/O Drawer |
Per 2P Building Block
Drawer |
SCSI
NOTE: Maximum storage controllers
per systems all types - Tru64 UNIX: 32, OpenVMS: 26 |
PCI 2-port Ultra3
(LVD) SCSI adapter, 64-bit/66-MHz dual-channel (uses one PCI slot); includes internal
68-pin and external 68-pin VHDCI connectors; requires
3X-BC56J-xx cable to connect adapter to DS-SL13R-Bx shelf; HSZxx RAID controllers not
supported. No shared SCSI or tape support, no SDLT tape support. No support for Model
4314R single-bus shelves with 3X-KZPEA-DB adapter. Tru64 UNIX requires graphics adapter to
run console utilities (RUN BIOS). |
16 |
8 |
4 |
12 |
8 |
4 |
66 MHz |
3.3V PCI |
3X-KZPEA-DB |
U160 cable, VHDCI to
VHDCI (341174-B21 6-feet,
341175-B21 12-feet, 164604-B21 24-feet)
xx = 02 (6-feet), 03 (12-feet), 04 (24-feet) |
|
3X-BC56J-xx |
| |
PCI 1-port Ultra2
(LVD) SCSI adapter, 32-bit/33-MHz, single-channel (uses one PCI slot); includes internal
68-pin and external 68-pin HD connectors; order
BN38C-xx cable to connect adapter to Ultra3 shelf, or order VHDCI converter (BN38E-0B) for
use with included cable; HSZxx RAID controllers not supported. No support for shared SCSI.
|
8 |
8 |
4 |
8 |
8 |
4 |
33 MHz |
3.3V PCI |
3X-KZPCA-AA |
| |
| PCI 1-port UltraSCSI
wide differential 32-bit/33-MHz PCI adapter (uses one PCI slot); includes external 68-pin
HD connector, requires BN38C-xx cable (2 to 25 meters) to connect adapter to differential
UltraSCSI shelf or RAID controller |
4 |
2 |
0 |
4 |
2 |
0 |
33 MHz |
5V PCI |
3X-KZPBA-CC |
68-pin HD
male-to-VHDCI male UltraSCSI cable;
xx = 02, 03, 05, 10, 20, meters |
|
BN38C-xx |
| |
| RAID |
Ultra160 2-channel
internal RAID controller with 128-MB cache.
NOTE: One controller supported per bus
segment; supported only as a data device. |
- |
- |
- |
1 |
1 |
1 |
66 MHz |
3.3V PCI |
3X-KZPDC-BE |
Ultra160 4-channel
internal RAID controller with 256-MB cache
NOTE: One controller supported per bus
segment; supported only as a data device. |
- |
- |
- |
1 |
1 |
1 |
66 MHz |
3.3V PCI |
3X-KZPDC-DF |
Ultra160 cable, VHDCI
to VHDCI (341174-B21 6-feet, 341175-B21 12-feet, 164604-B21 24-feet)
xx = 02 (6-feet), 03 (12-feet), 04 (24-feet) |
|
3X-BC56J-xx |
| |
|
|
| Fibre
Channel |
| PCI to 2-Gbit Fibre
Channel adapter, 64-bit/66-MHz, single-channel |
16 |
8 |
4 |
16 |
8 |
4 |
66 MHz |
3.3V PCI |
DS-KGPSA-DA |
| PCI to Fibre Channel
Host Bus Adapter, 64-bit/66-MHz |
|
|
|
|
|
|
66 MHz |
3.3V PCI |
DS-SWLA4-PD |
Fibre Channel cable
(BNGBX-xx)
xx=02, 03, 05, 10, 15, 30, 50 meters |
|
BNGBX-xx |
| |
|
|
| CI |
|
|
| PCI CI adapter,
requires two PCI slots Each PCI CI adapter ordered requires the mandatory
selection of an I/O Expansion Drawer (see Step 6) |
NA |
NA |
NA |
2 |
1 |
0 |
33 MHz |
5V |
CIPCA-BA |
| Computer interconnect
cable set, connects CIPCA to star coupler; select length xx=10, 20, 45 meters |
|
BNCIA-xx |
| |
| Step 9- StorageWorks Universal Shelves |
| StorageWorks
Model 4314R and Model 4354R Universal Drive Shelves |
StorageWorks
Model 4314R and 4354R Ultra3 SCSI (LVD) single-bus and split-bus Universal drive shelves;
refer to StorageWorks Enclosure 4300 Family QuickSpecs when configuring shelves. When
selecting a DS-SL13R-Bx split-bus shelf, two SCSI channels are required. No support for
Model 4314R or 4314T single-bus shelves with 3X-KZPEA-DB adapter.. Note that the depth of
a DS-SL13R-xx shelf does not allow front and rear mounting.
NOTE: DS-SL13R single-bus shelves
include one 12-foot VHDCI to VHDCI SCSI cable; dual-bus shelves include two 12-foot VHDCI
TO VHDCI SCSI cables. |
|
StorageWorks Model
4314R Ultra3 SCSI (LVD) single-bus Universal drive rackmount shelf includes one power
supply. No support for Model 4314R single-bus shelves with embedded Ultra3SCSI adapter or
3X-KZPEA-DB adapter, US |
DS-SL13R-AA
|
|
StorageWorks Model
4314R Ultra3 SCSI (LVD) single-bus Universal drive rackmount shelf includes one power
supply. No support for Model 4314R single-bus shelves with embedded Ultra3SCSI adapter or
3X-KZPEA-DB adapter, Japan |
DS-SL13R-AJ
|
|
StorageWorks Model
4354R Ultra3 SCSI (LVD) split-bus Universal drive rackmount shelf, includes two redundant
power supplies, U.S. |
DS-SL13R-BA |
|
StorageWorks Model
4354R Ultra3 SCSI (LVD) split-bus Universal drive rackmount shelf, includes two redundant
power supplies, Japan |
DS-SL13R-BJ
|
| |
| Disk
Drives (Supported in Model 4314R and 4354R Universal Drive Enclosures) |
|
36.4-GB Ultra320 SCSI
10,000 rpm 1-inch Universal disk drive |
3R-A3838-AA |
|
72.8-GB Ultra320 SCSI
10,000 rpm 1-inch Universal disk drive |
3R-A3839-AA |
|
146-GB Ultra320 SCSI
10,000 rpm 1-inch Universal disk drive |
3R-A3841-AA |
|
18.2-GB Ultra320 SCSI
15,000 rpm 1-inch Universal disk drive |
3R-A3848-AA |
|
36.4-GB Ultra320 SCSI
15,000 rpm 1-inch Universal disk drive |
3R-A3849-AA |
|
72.8-GB Ultra320 SCSI
15,000 rpm 1-inch Universal disk drive |
3R-A3851-AA |
| |
| Step 10 - Storage Options |
| Step 10a -- Tape Devices |
| AIT
Hot-plug Tape Drives (for use in StorageWorks Model 4314R and 4354R Universal Drive
Shelves) |
- AIT hot-plug tape drives require two Universal slots
|
|
| AIT 35/70-GB hot-plug
LVD Universal tape drive, uses two slots in 43xxx shelves |
3R-A2396-AA |
| AIT 50/100-GB hot-plug
LVD Universal tape drive, uses two slots in 43xxx shelves |
3R-A2779-AA |
| |
|
|
| Autoloaders |
AIT 35-GB rackmount
autoloader, 8 cartridge, U.S. |
280349-001 |
|
Same as above,
International |
280349-B31 |
|
AIT Rail kit for
rackmount autoloader |
284930-001 |
| |
|
|
| AIT
Tape Libraries |
SSL2020 AIT rackmount
library with one AIT 50-GB drive and 20 slots, LVD |
175196-B21 |
| SSL2020 AIT rackmount
library with two AIT 50-GB drives and 20 slots, LVD |
175196-B22 |
| |
|
|
| DAT Hot-plug Tape
Drive |
DAT 20/40-GB DDS4
hot-plug LVD Universal tape drive, uses two slots in 43xxx shelves |
3R-A2780-AA |
| |
|
|
| DLT/SDLT
Tape Libraries |
MSL5026DLX, DLT
rackmount library with 1 40/80-GB DLT tape drive, LVD |
231891-B21 |
| MSL5026DLX, DLT
rackmount library with 2 40/80-GB DLT tape drives, LVD |
231891-B22 |
| MSL5026SL, SDLT
rackmount library with 1 110/220-GB SDLT tape drive, LVD; graphite |
302512-B21 |
| MSL5026SL, SDLT
rackmount library with 2 110/220-GB SDLT tape drives, LVD; graphite |
302512-B22 |
|
MSL5026S2, SDLT
rackmount library with 0 drives, LVD; graphite |
293472-B21 |
| MSL5026S2, SDLT
rackmount library with 1 160/220-GB SDLT tape drive, LVD; graphite |
293472-B22 |
| MSL5026S2, SDLT
rackmount library with 1 160/220-GB SDLT tape drive, LVD; graphite |
293472-B23 |
| MSL5026S2, SDLT
rackmount library with 1 160/220-GB SDLT tape drive, Fibre Channel Interface; graphite |
293472-B24 |
| MSL5026S2, SDLT
rackmount library with 2 160/220-GB SDLT tape drives, Fibre Channel Interface; graphite |
293472-B25 |
| |
|
| MSL5000 SDLT2 upgrade
drive, all |
293475-B21 |
| MSL5052SL SDLT
rackmount library, 0 drives, LVD |
255102-B21 |
| MSL5052SL SDLT
rackmount library with 2 110/220-GB drives, LVD |
249491-B21 |
| MSL5052SL SDLT
110/220-GB drive field upgrade, LVD |
231823-B22 |
| MSL5052S2, SDLT
rackmount library with 2 160/220-GB SDLT tape drives, LVD; graphite |
293474-B21 |
| MSL5052S2, SDLT
rackmount library with 2 160/220-GB SDLT tape drives, Fibre Channel Interface; graphite |
293474-B24 |
| |
|
| ESL9322S2 SDLT tape
library, with 2 160/320-GB SDLT tape drives, 222 slots -
requires 3X-KZPCA-AA adapter |
293409-B22 |
| ESL9322S2 SDLT tape
library, with 8 160/320-GB SDLT tape drives, 222 slots -
requires 3X-KZPCA-AA adapter |
293409-B28 |
| ESL9322S2 SDLT tape
library, with 2 160/320-GB SDLT tape drives, 322 slots -
requires 3X-KZPCA-AA adapter |
293410-B22 |
| ESL9322S2 SDLT tape
library, with 8 160/320-GB SDLT tape drives, 322 slots -
requires 3X-KZPCA-AA adapter |
293410-B28 |
| ESL9000 SDLT2 LVD
Upgrade Drive |
293414-B21 |
| ESL9595SL SDLT tape
library, 0 drives, 400 slots - requires 3X-KZPCA-AA adapter |
274672-B21 |
| ESL9595SL SDLT tape
library, 2 drives, 400 slots - requires 3X-KZPCA-AA adapter |
274672-B22 |
| ESL9595SL SDLT tape
library, 16 drives, 400 slots - requires 3X-KZPCA-AA adapter |
274672-B28 |
| ESL9595SL SDLT tape
library, 0 drives, 500 slots - requires 3X-KZPCA-AA adapter |
281627-B21 |
| ESL9595SL SDLT tape
library, 2 drives, 500 slots - requires 3X-KZPCA-AA adapter |
281627-B22 |
| ESL9595SL SDLT tape
library, 16 drives, 500 slots - requires 3X-KZPCA-AA adapter |
281627-B28 |
| ESL9595SL SDLT tape
library, 0 drives, 595 slots - requires 3X-KZPCA-AA adapter |
281628-B21 |
| ESL9595SL SDLT tape
library, 2 drives, 595 slots - requires 3X-KZPCA-AA adapter |
281628-B22 |
| ESL9595SL SDLT tape
library, 16 drives, 595 slots - requires 3X-KZPCA-AA adapter |
281628-B28 |
|
ESL9595S2 SDLT2 tape
library, 2 drives, 400 slots - requires 3X-KZPCA-AA adapter |
293411-B22 |
| ESL9595S2 SDLT2 tape
library, 16 drives, 400 slots - requires 3X-KZPCA-AA adapter |
293411-B28 |
| ESL9595S2 SDLT2 tape
library, 2 drives, 500 slots - requires 3X-KZPCA-AA adapter |
293412-B22 |
| ESL9595S2 SDLT2 tape
library, 16 drives, 500 slots - requires 3X-KZPCA-AA adapter |
293412-B28 |
| ESL9595S2 SDLT2 tape
library, 2 drives, 595 slots - requires 3X-KZPCA-AA adapter |
293413-B22 |
| ESL9595S2 SDLT2 tape
library, 16 drives, 595 slots - requires 3X-KZPCA-AA adapter |
293413-B28 |
| ESL9000 SDLT2 LVD
upgrade drive |
293414-B21 |
| |
| 3U 3U
Rackmount Tape Drive Enclosure |
NOTE: The 3U Tape Drive Enclosure supports up to four internal
half-height removable devices, or up to two full height devices. Select up to four AIT or
DAT devices, or two DLT/SDLT devices with 3U Rackmount Tape Drive Enclosure (274338-B21),
or select preconfigured configurations listed below |
| AIT 35/70-GB tape
drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
216884-B21 |
| AIT 50/100-GB tape
drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
3R-A3753-AA |
| DAT 20/40-GB tape
drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
3R-A3752-AA |
| DLT8000 40/80-GB tape
drive, requires 3X-KZPCA-AA LVD adapter |
146196-B22 |
| SDLT 110/220-GB tape
drive, requires 3X-KZPCA-AA LVD adapter |
192106-B25 |
| SDLT 160/320-GB tape
drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
257319-B21 |
| Preconfigured
configurations |
| AIT 50-GB 3U rackmount
kit, carbon black |
274333-B21 |
| DLT 40/80-GB, 3U
rackmount kit, carbon black |
274332-B21 |
| DLT 40/80-GB,
dual-drive, 3U rackmount kit, carbon black |
274335-B21 |
| SDLT 110/220-GB, 3U
rackmount kit, carbon black |
274331-B21 |
| SDLT 110/220-GB,
dual-drive, 3U rackmount kit, carbon black |
274334-B21 |
| |
|
|
| 5U 5U
Rackmount Tape Drive Enclosure |
NOTE: The 5U Rackmount Tape Drive Enclosure supports four
full-height devices; select up to four DLT or SDLT devices with 274339-B21, or select
preconfigured configurations listed below |
| DLT8000 40/80-GB tape
drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
146196-B22 |
| SDLT 110/220-GB tape
drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
192106-B25 |
| SDLT 160/320-GB tape
drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
257319-B21 |
| Preconfigured
configurations |
| SDLT 110/220-GB Tape
Array III, 5U rackmount kit, carbon black |
274336-B21 |
| DLT 40/80-GB Tape
Array III, 5U rackmount kit, carbon black |
274337-B21 |
| DLT Tape Array III
Model 0 enclosure, U.S. |
168047-001 |
| Same as above,
International |
168047-B31 |
| Same as above, Japan |
168047-291 |
| |
|
|
| Step 10b hp StorageWorks Network Storage Router M2402 |
|
2 Fibre Channel x 4
LVD SCSI Ports |
3R-A3740-AA |
|
2 Fibre Channel x 4
HVD SCSI Ports |
3R-A3741-AA |
| |
| Step 10c External Storage Solutions/Controllers |
|
41U
graphite storage cabinet, M3220 Controller assembly with dual HSV110 controllers, 6 M5214
dual FC loop 14-bay drive enclosures, 4 FC loop switches; Model 2C6D-B, 60 Hz |
DS-SV110-JA
|
|
41U
graphite storage cabinet, M3220 Controller assembly with dual HSV110 controllers, 6 M5214
dual FC loop 14-bay drive enclosures, 4 FC loop switches; Model 2C6D-B, 50 Hz |
DS-SV110-JB
|
|
41U
graphite storage cabinet, M3220 Controller assembly with dual HSV110 controllers, 12 M5214
dual FC loop 14-bay drive enclosures, 4 FC loop switches; Model 2C12D-B, 60 Hz |
DS-SV110-KA
|
|
41U
graphite storage cabinet, M3220 Controller assembly with dual HSV110 controllers, 12 M5214
dual FC loop 14-bay drive enclosures, 4 FC loop switches; Model 2C12D-B, 50 Hz |
DS-SV110-KB
|
|
Fibre
Channel Controller (HSG80), includes 256-MB cache, requires following firmware: 8.6-4F
ACS FW (222318-B22, QB-6BUAA-SD), one per controller
8.6-4S ACS FW (222364-B22, QB-6ENAA-SC), one per controller
8.6-4P ACS FW (222316-B22, QB-6CAAA-SD), one per controller
requires Tru64 UNIX software: 222320-B23, QB-65RAB-SE, one per controller
requires OpenVMS software: 222321-B22, QB-65RAC-SD, one per controller |
DS-HSG80-BK |
|
Additional
256-MB cache for HSG80 |
DS-HSDIM-AC |
|
Single
cache battery, one per HSG80 controller |
DS-SE2CS-CB |
|
Model 2200
controller shelf for HSG80 controller only supported in 9000 Series and M-Series
Cabinets |
DS-SE2ZS-C8 |
| |
|
|
| Step 10d Fibre Channel Options |
|
The
following disk drives, hubs, data routers, switches, and cables are used in Fibre Channel
configurations using the DS-KGPSA-xx adapter. |
|
| |
|
|
| Fibre Channel Disk
Drives |
36-GB 10K
rpm dual-port 2-Gb/sec FC-AL 1-inch (25.4 mm) drive |
3R-A3239-AA |
|
36-GB 15K
rpm dual-port 2-Gb/sec FC-AL 1-inch (25.4 mm) drive |
3R-A3210-AA |
|
72-GB 10K
rpm dual-port 2-Gb/sec FC-AL 1-inch (25.4 mm) drive |
3R-A3260-AA |
| |
|
|
| Fibre Channel Hubs |
Fibre
Channel 7-port Storage Hub, International (Tru64 UNIX only) |
DS-SWXHB-I7 |
|
Fibre
Channel 7-port Storage Hub, North America (Tru64 UNIX only) |
DS-SWXHB-07 |
|
Fibre
Channel 7-port Storage Hub, Japan (Tru64 UNIX only) |
DS-SWXHB-J7 |
| |
|
|
| Fibre
Channel Data Routers |
1 Fibre
Channel x 2 HVD data router |
3R-A2673-AA |
| 1 Fibre
Channel x 2 LVD data router |
3R-A2774-AA |
|
2 x 4 LVD
Fiber Channel to SCSI Network Storage Router |
3R-A3740-AA |
|
2 x 4 HVD
Fiber Channel to SCSI Network Storage Router |
3R-A3741-AA |
| |
|
|
| Fibre
Channel Switches |
Fibre
Channel 2-Gb 8-port SAN switch |
DS-DSGGD-AC |
| Fibre
Channel 2-Gb 16-port SAN switch |
DS-DSGGD-AD |
|
Fibre
Channel 2-Gb SAN switch 16-port; |
DS-DSGGD-BA |
|
Fibre
Channel 2-Gb 64-port Core Switch |
DS-DSGGE-AB |
| |
| McData
64-port Fibre Channel Director/Edge Class Switches |
SAN
Director 64 (1 Gb) 32 ports, base model |
DS-DMGGD-BA |
| SAN
Director 64 Long-wave 4-port module kit |
DS-DMGGD-AC |
|
SAN
Director 64 Short-wave 4-port module kit |
DS-DMGGD-AD |
|
SAN
Director 64 Combo, Long 1 port/Short 3 ports Wave Module Kit |
DS-DMGGD-AE |
|
HP
StorageWorks Edge Switch 2/16 |
DS-DMGGE-BB |
|
HP
StorageWorks Edge Switch 2/32 |
DS-DMGGE-BC |
| |
|
|
| Fibre Channel
Cables |
NOTE:
The following LC-SC connector cables support connectivity between 1-Gb and
2-Gb devices. |
|
|
2-meter LC-SC
multi-mode Fibre Channel cable |
3R-A2976-AA |
|
5-meter LC-SC
multi-mode Fibre Channel cable |
3R-A2977-AA |
|
15-meter LC-SC
multi-mode Fibre Channel cable |
3R-A2978-AA |
| |
|
|
|
NOTE:
The following LC-LC connector cables support connectivity between 2-Gb and
2-Gb devices. |
|
|
2-meter LC-LC
multi-mode Fibre Channel cable |
3R-A2979-AA |
|
5-meter LC-LC
multi-mode Fibre Channel cable |
3R-A2980-AA |
|
15-meter LC-LC
multi-mode Fibre Channel cable |
3R-A2981-AA |
| |
|
|
| Step 11 - Networks and Communications |
| Step 11a - Networks and Communications - Mandatory |
- Mandatory
selection of at least one of the following Ethernet adapters is required
for each ES47 system ordered
- Maximum network adapters supported per system, all types - Tru64 UNIX: 16, OpenVMS: 16
|
| |
Maximum # Supported |
Speed |
PCI/
PCI-
X
Slot |
|
| |
Tru64 UNIX |
OpenVMS |
| |
Per
System |
Per External I/O
Drawer |
Per 2P Building Block
Drawer |
Per
System |
Per External I/O
Drawer |
Per 2P Building Block
Drawer |
| Ethernet
Adapters |
PCI (32/64-bit,
33-MHz to 66-MHz) dual-port 10/100 Ethernet (UTP/RJ45s) NIC and Base Module. (One
3X-DE602-TA or 3X-DE602-FA optional add-on daughter card can be combined with this
module.)
NOTE: Use BN25G, BN26M, BN24Q, or BN28Q
twisted pair RJ45 cables. |
8 |
8 |
4 |
8 |
8 |
4 |
66 MHz |
3.3/
5V |
3X-DE602-BB |
PCI-X/PCI Single-port
10/100/1000 Mbps (Twisted-pair Copper with RJ45) Gigabit Ethernet NIC.
Cables - BN25G, BN26M, BN24Q, BN28Q, or equivalent with RJ45 connectors.
NOTE: Only supported in PCI mode.
Supported as a cluster interconnect under OpenVMS only. OpenVMS remedial kit required: EV7
Tima: DEC-AXPVMS
VMS731_EV7-
V0100- -4.PCSI
LAN Tima: DEC-AXPVMS-
VMS731
_LAN-V0100-
-4.PCSI |
8 |
8 |
4 |
8 |
8 |
4 |
66 MHz |
3.3V |
3X-DEGXA-TA |
| |
| Step 11b - Networks and Communications - Optional |
| |
Maximum # Supported |
Speed
|
PCI/
PCI-
X
Slot |
|
| |
Tru64 UNIX |
OpenVMS |
| |
Per
System |
Per External I/O
Drawer |
Per 2P Building Block
Drawer |
Per
System |
Per External I/O
Drawer |
Per 2P Building Block
Drawer |
| Ethernet
Adapters |
Dual-port 10/100
Ethernet (UTP/RJ45) add-on daughter card for use with the 3X-DE602-BB only. The combined
3X-DE602-BB and 3X-DE602-TA modules provide four 10/100 (UTP/RJ45s) ports in a single PCI
slot option.
OpenVMS remedial kit required:
VMS731_LAN-V0100NOTE: 3X-DE602-TA cannot be used standalone.
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
8 |
8 |
4 |
8 |
8 |
4 |
33 MHz |
3.3/
5V |
3X-DE602-TA |
| Single-port 100 Mbps
(MMF/duplex-SC) add-on daughter card for use with the 3X-DE602-BB. The combined
3X-DE602-BB and 3X-DE602-FA provides two 10/100 (UTP/RJ45s) and one 100Mbps (MMF/SC)
ports in a single PCI slot option. NOTE:
3X-DE602-FA cannot be used standalone.
Use BN34A or BN34B cables. |
8 |
8 |
4 |
8 |
8 |
4 |
33 MHz |
3.3/
5V |
3X-DE602-FA |
PCI-X/PCI Single-port
1000 Mbps (Fiber with duplex-SC) Gigabit Ethernet NIC. Cables - BN34A, BN34B, or
equivalent with SC connectors.
NOTE: Only supported in PCI mode.
Supported as a cluster interconnect under OpenVMS only. OpenVMS remedial kit required:
EV7 Tima: DEC-AXPVMS
VMS731
_EV7-V0100- -4.PCSI
LAN Tima: DEC-AXPVMS
-VMS731_LAN
-V0100--4.PCSI |
8 |
8 |
4 |
8 |
8 |
4 |
66 MHz |
3.3 V |
3X-DEGXA-SA |
| |
| FDDI
Controllers |
PCI (32-bit, 33-MHz)
to FDDI SAS (MMF/duplex-SC) NIC
Use BN34A, BN34B, or BN34D cables. |
8 |
8 |
4 |
8 |
8 |
4 |
33 MHz |
3.3/
5 V |
3X-DEFPA-AC |
PCI (32-bit, 33-MHz)
to FDDI DAS (MMF/duplex-SC) NIC
Use BN34A, BN34B, or BN34D cables. |
8 |
8 |
4 |
8 |
8 |
4 |
33 MHz |
3.3/
5V |
3X-DEFPA-DC |
PCI (32-bit, 33-MHz)
to FDDI DAS (UTP/RJ45) NIC
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
8 |
8 |
4 |
8 |
8 |
4 |
33 MHz |
3.3/
5V |
3X-DEFPA-MC |
PCI (32-bit, 33-MHz)
to FDDI SAS (UTP/RJ45) NIC
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
8 |
8 |
4 |
8 |
8 |
4 |
33 MHz |
3.3/
5V |
3X-DEFPA-UC |
Multimode fiber optic
(MMF) 62.5/125um duplex cable with SC-to-MIC connectors xx = available lengths:
(01, 03, and 10) for 1, 3, and 10 meters |
|
BN34D-xx |
| |
| Synchronous/Asynchronous
Controllers |
| PCI (32-bit, 33-MHz)
to Dual-port Intelligent Synchronous Communications NIC -- Requires at least one (maximum
two) BN34x sync cable listed below |
- |
- |
- |
4 |
4 |
2 |
33 MHz |
3.3V PCI |
3X-PBXDD-AA |
| PCI (32-bit, 33-MHz)
to Quad-port Intelligent Synchronous Communications NIC -- Requires at least one (maximum
four) BN34x sync cable listed below. |
- |
- |
- |
4 |
4 |
2 |
33 MHz |
3.3V PCI |
3X-PBXDD-AB |
| Synchronous-specific
Cables |
| EIA-530 Single-port
cable |
|
3X-BC34G-06 |
| V.24/EIA-232
Single-port cable |
|
3X-BC34L-06 |
| V.11/x.21 Single-port
cable |
|
3X-BC33S-06 |
| V.35 Single-port
cable |
|
3X-BC34T-06 |
| |
| Asynchronous
Communications |
| PCI (32-bit, 33-MHz)
to 4-port Async Communications NIC with DB-25 octopus cable |
2 |
2 |
2 |
2 |
2 |
2 |
33 MHz |
3.3/
5V |
PBXDA-BA |
| PCI (32-bit, 33-MHz)
to 16-port Async Communications Controller and rackmount 16-port distribution box with
RJ45 connectors |
2 |
2 |
2 |
2 |
2 |
2 |
33 MHz |
3.3/
5V |
PBXDA-AC |
| Asynchronous
Connector Cables |
| RJ45-to-DB-25
Converter Cable |
|
CXI01-AC |
| RJ45-to-DEC MJ11
Converter Cable (8 pack) |
|
CXI01-AF |
| |
| ATM Adapters |
| PCI (32-bit, 33-MHz)
to 155 Mbps ATM, Copper NIC with RJ45 connector. Use BN25G-xx, or BN26M-xx cables. |
8 |
8 |
4 |
8 |
8 |
4 |
33 MHz |
3.3/
5V |
3X-DAPBA-UA |
| PCI (32-bit, 33-MHz) to 155 Mbps
ATM Fiber NIC with SC connector. Use BN34B-xx cable. |
8 |
8 |
4 |
8 |
8 |
4 |
33 MHz |
3.3/
5V |
3X-DAPBA-FA |
| |
| Ethernet,
FDDI, ATM Cables |
| Multimode fiber optic
(MMF) 62.5/125um duplex cable, with SC-to-ST connectors. xx = available lengths: (2E, 4E,
01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, and 30 meters |
|
BN34A-xx |
| Multimode fiber optic
(MMF) 62.5/125um duplex cable, with SC-to-SC connectors. xx = available lengths: (2E, 4E,
01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, and 30 meters |
|
BN34B-xx |
| Category 5e
(4-Unshielded Twisted Pairs / UTP) straight-through cable with RJ45-to-RJ45 connectors for
system to switch, repeater, or hub connectivity. xx = available lengths: (0B, 0E, 01, 03,
04, 07) for 0.2, 0.5, 1, 3, 4, and 7 meters |
|
BN25G-xx |
| Category 5e
(4-Twisted Pairs, Screened/ ScTP) straight-through cable with RJ45-to-RJ45 connectors for
system to switch, repeater, or hub connectivity. xx = available lengths: (0E, 01, 03, 04,
07) for 0.5, 1, 3, 4, and 7 meters |
|
BN26M-xx |
| Category 5e
(4-Unshielded Twisted Pairs / UTP) Xover cable with RJ45-to-RJ45 connectors for system to
switch, repeater, or hub connectivity. xx = available lengths: (0E, 01, 03, 04, 07) for
0.5, 1, 3, 4, and 7 meters |
|
BN24Q-xx |
| Category 5e
(4-Twisted Pairs, Screened / ScTP) Xover cable with RJ45-to-RJ45 connectors for system to
switch, repeater, or hub connectivity. xx = available lengths: (0E, 01, 03, 04, 07) for
0.5, 1, 3, 4, and 7 meters |
|
BN28Q-xx |
|
| Step 12 - Graphics
Support |
| |
Maximum
# Supported |
|
| |
Tru64
UNIX |
OpenVMS |
|
| |
Per
System |
Per
External I/O Drawer |
Per 2P
Building Block Drawer |
Per
System |
Per
External I/O Drawer |
Per 2P
Building Block Drawer |
Speed |
PCI/
AGP
Slot |
|
| 3Dlabs Oxygen VX1 32-MB PCI 2D
graphics accelerator |
2 |
2 |
1 |
1 |
1 |
1 |
66 MHz |
3.3V PCI |
SN-PBXGF-AB |
| 3Dlabs Oxygen VX1 32-MB AGP 2D
graphics accelerator |
1 |
1 |
1 |
1 |
1 |
1 |
4X(1) |
AGP |
SN-PBXGF-BC |
| ATI Radeon 7500 2D AGP graphics
accelerator |
1 |
1 |
1 |
- |
- |
- |
4X(1) |
AGP |
3X-PBXGG-AB |
(1) Only
supported in 2X mode
Maximum graphics adapters per systems, all types - Tru64 UNIX: 2 (1 AGP and 1 PCI or 2
PCI), OpenVMS: 2 (1 AGP and 1 PCI or 2 PCI) |
| |
| Step 13-
MEMORY CHANNEL |
| Configuring Information |
- Up to two PCI-to-System Area Network adapters (CCMAB-AA) are supported in a single
system.
- Each PCI-to-System Area Network adapter ordered requires the mandatory selection
of an I/O Expansion Drawer (see step 6)
- Only supported with Tru64 UNIX
|
|
|
- Two-node clusters can be configured by ordering a CCMAB-AA for each node and one
BN39B-04 or BN39B-10 cable, cable connects directly to CCMAB-AA in each node
- For a two-node cluster that will not need to be rebooted when adding additional members,
order one CCMAB-AA adapter and one BN39B-04 or BN39B-10 cable for each node and one
CCMHB-AA hub for the cluster
- For three or four node clusters, order one CCMAB-AA adapter and one BN39B-04 or BN39B-10
cable for each node and one CCMHB-AA hub for the cluster
|
|
|
- CCMHB-AA includes four CCMLB-AA line cards and supports up to four nodes; expansion up
to eight system nodes can be achieved by adding up to four CCMLB-AA line cards
|
|
|
- If two CCMAB-AAs are configured in each system, a second CCMHB-AA is required.
|
|
|
- If nodes must be separated by a distance longer than standard copper cables allow the
CCMFB option converts the output of the standard CCMAB controller or CCMLB line card to
single-mode fiber optic cable. The fiber optic connection may be up to 2,000 meters long
between two CCMAB controllers connected in virtual hub mode, or 3,000 meters between a
CCMAB controller and a CCMHB hub. (The connection from the CCMHB hub to a second system
may also be 3,000 meters.) The CCMFB option requires a second PCI slot in the system from
which it draws power only. It is normally connected to the corresponding CCMAB controller
with the short BN39B-01 cable. The CCMFB is also used in the CCMHB hub where it occupies a
slot normally used by the CCMLB line card, limiting expansion to four radial fiber optic
connections.
|
|
|
- CCMHB-BA hub expansion box provides additional slots for up to eight fiber optic
connections. Two standard length single-mode fiber optic cables are available (BN34R-10
and BN34R-31); however, users normally provide this fiber optic connection. Fiber optic
connectivity is completely transparent to the systems using it and has no performance
impact.
|
|
| |
|
|
| Tru64 UNIX (V5.1B) |
- Each system node in the cluster requires a TruCluster software license
(QL-6BRAE-AA) or TruCluster Plus Software Package (QP-6R9AE-AA)
|
|
| |
|
|
| MEMORY CHANNEL
Controller/ System Area Network Hub |
PCI-to-System Area Network
Controller, maximum two 5V/33 MHz |
CCMAB-AA |
| System Area Network
Hub with four line cards; includes BN19P-2E power cord for Canada, Japan, and U.S. For
other regions, order appropriate power cord from the following list: |
CCMHB-AA |
|
Hub expansion box
with no line cards |
CCMHB-BA |
|
Expansion line card
for CCMHB hub |
CCMLB-AA |
|
1-meter cable for
CCMAB and CCMHB |
BN39B-01 |
|
4-meter cable for
CCMAB and CCMHB |
BN39B-04 |
|
10-meter cable for
CCMAB and CCMHB |
BN39B-10 |
|
Copper-to-single mode
fiber optic converter - 5V (clock not affected) |
CCMFB-AA |
|
Rackmount kit (3U)
for CCMHB (Memory Channel Hub II); required for mounting in
11000-series cabinets. |
3X-BA61R-MD |
|
Power cord for
rackmount CCMHB hub |
BN35S-02 |
| |
|
|
Country-specific
Power Cords
for Standalone MEMORY CHANNEL Hubs |
Australia, New Zealand |
BN19H-2E |
| Central Europe |
BN19C-2E |
| Denmark |
BN19K-2E |
|
Egypt, India |
BN19S-2E |
|
Ireland, United Kingdom |
BN19A-2E |
| Israel |
BN18L-2E |
| Italy |
BN35M-02 |
| Japan, 2.5-meter, Dentori
approved |
3X-BN46F-02 |
| Switzerland |
BN19E-2E |
| |
| Step
14 - Mouse, Monitors, Power Cords, Keyboards |
| Keyboard, Mouse, and Video
Extension Cable Kit |
Two 6-foot/1.8-meter USB
keyboard/mouse extension cables and one 6-foot/1.8-meter video extension cable (one per
system) |
CK-GSKVM-AA |
| |
| Video Extension Cable |
6-foot/1.8-meter video extension
cable |
BN39C-02 |
| |
|
|
| Mouse |
3-button mouse - USB |
3X-PBQWS-WB |
| |
| Monitors |
- Graphics monitors other than those listed can be used if compatible with SVGA graphics
ordered with system
- A video cable, 6-foot/1.8-meter length, is included with all variants of monitors
- Video extension cable required if monitor is located more than 1-meter from server
- Monitors will ship with, but not be integrated with systems
|
| |
| Carbon/Silver Monitors |
V7550 17-inch (16-inch viewable
image size) flat-faced shadow mask color monitor, two-tone (carbon/silver), 0.25mm dot
pitch, VGA to 1024 x 768 @85 Hz, MPRII/TCO99/ Energy Star compliant, Northern Hemisphere
with NA power cord, VGA cable |
3R-A4002-AA |
|
Same as above, with Euro power
cord |
3R-A4201-AA |
|
Same as above, APD, no power cord |
3R-A4202-AA |
|
Same as above, with PRC power
cord, CCIB |
3R-A4446-AA |
|
Same as above, Southern
Hemisphere, with Australia/New Zealand power cord |
3R-A4203-AA |
| |
|
P930 19-inch (18-inch viewable
image size) auto-scanning color monitor, Diamondtron NF, 0.24-mm aperture grille pitch,
VGA to 1600 x 1200 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA
power cord, VGA cable |
3R-A4215-AA
|
|
Same as above, with Euro power
cord |
3R-A4391-AA |
|
Same as above, Taiwan, with NA
power cord |
3R-A4392-AA |
|
Same as above, with PRC power
cord, CCIB |
3R-A4394-AA |
|
Same as above, Southern
Hemisphere, 0.25 to 0.27 mm aperture grille pitch, with Australia/New Zealand power cord |
3R-A4393-AA
|
| |
|
P1130 21-inch (19.8-inch viewable
image size) FD Trinitron auto-scanning color monitor, 0.24-mm aperture grille pitch, VGA
to 1792 x 1344 @85Hz, dual video input, USB Hub, MPRII/TCO 99/Energy Star Compliant,
Northern Hemisphere with NA power cord, VGA cable |
3R-A4216-AA
|
|
Same as above, with Euro power
cord |
3R-A4396-AA |
|
Same as above, Taiwan, NA power
cord |
3R-A4397-AA |
|
Same as above, with PRC power
cord, CCIB |
3R-A4400-AA |
|
Same as above, Southern
Hemisphere, with Australia/New Zealand power cord |
3R-A4398-AA |
| |
| Carbon/Silver Flat Panel
Monitors |
TFT1825, 18-inch (18-inch
viewable image size) TFT flat panel monitor, 0.28mm pixel pitch, 1600 x 1200 @60Hz,
multi-mode support, MPRII/TCO99/Energy Star compliant, one VGA, one DVI-I input connector.
NA power cord, VGA and DVI-I cables |
3R-A4292-AA |
|
TFT1520, 15-inch (15-inch
viewable image size) TFT flat panel monitor, 0.297 mm pixel pitch, 1024 x 768 @75 Hz,
multi-mode support, MPRII/TCO99/Energy Star compliant, two video input connectors (one VGA
and one DVI-I), NA power cord, VGA and DVI-I cables |
3R-A4249-AA |
| |
| Monitor Power
Cords |
North American, 120V,
75-inch |
BN26J-1K |
|
Australia, New
Zealand, 2.5-meter |
BN19H-2E |
|
Central Europe,
2.5-meter |
BN19C-2E |
|
Denmark, 2.5-meter |
BN19K-2E |
|
Egypt, India, South
Africa, 2.5-meter |
BN19S-2E |
|
Israel, 2.5-meter |
BN18L-2E |
|
Italy, 2.5-meter |
BN35M-02 |
|
Japan, 2.5-meter,
Dentori approved |
3X-BN46F-02 |
|
Switzerland,
2.5-meter |
BN19E-2E |
|
UK, Ireland, 2.5-meter |
BN19A-2E |
| Keyboards - USB
Keyboard/Language |
Tru64 UNIX |
OpenVMS |
| U.S./English keyboard |
3R-LKQ50-AA |
3X-LK463-A2 |
| Arabic keyboard |
3R-LKQ50-BR |
- |
| Belgian keyboard |
3R-LKQ50-AB |
3X-LK463-AB |
| BHCSY keyboard |
3R-LKQ50-AX |
- |
| Canadian/English keyboard |
- |
3X-LK463-AQ |
| Canadian/French keyboard |
3R-LKQ50-AC |
3X-LK463-AC |
| Cyrillic keyboard (Russian) |
3R-LKQ50-BT |
3X-LK463-BT |
| Czech keyboard |
3R-LKQ50-BV |
3X-LK463-BV |
| Danish keyboard |
3R-LKQ50-AD |
3X-LK463-AD |
| Dutch keyboard |
3R-LKQ50-AH |
3X-LK463-AH |
| Finnish keyboard |
- |
3X-LK463-AF |
| French keyboard |
3R-LKQ50-AP |
3X-LK463-AP |
| German keyboard |
3R-LKQ50-AG |
3X-LK463-AG |
| Greek keyboard |
3R-LKQ50-BH |
3X-LK463-BH |
| Hebrew keyboard |
3R-LKQ50-AT |
3X-LK463-AT |
| Hungarian keyboard |
3R-LKQ50-BQ |
3X-LK463-BQ |
| International keyboard |
3R-LKQ50-BA |
- |
| Italian keyboard |
3R-LKQ50-AI |
3X-LK463-AI |
| Japanese keyboard |
3R-LKQ50-AJ |
- |
| Korean keyboard |
3R-LKQ50-BK |
- |
| Latin-American keyboard |
3R-LKQ50-AR |
- |
| Norwegian keyboard |
3R-LKQ50-AN |
3X-LK463-AN |
| Polish keyboard |
3R-LKQ50-BP |
3X-LK463-BP |
| Portuguese keyboard |
3R-LKQ50-AV |
3X-LK463-AV |
| Romanian keyboard |
- |
3X-LK463-BL |
| Simplified Chinese keyboard |
3R-LKQ50-CV |
- |
| Spanish keyboard |
3R-LKQ50-AS |
3X-LK463-AS |
| Swedish keyboard |
3R-LKQ50-AM |
3X-LK463-AM |
| Swiss/French keyboard |
3R-LKQ50-AK |
3X-LK463-AK |
| Swiss/German keyboard |
- |
3X-LK463-AL |
| Traditional Chinese keyboard |
3R-LKQ50-BI |
- |
| Thai keyboard |
3R-LKQ50-CB |
- |
| Turkish keyboard |
3R-LKQ50-BU |
3X-LK463-BU |
| Turkish/F keyboard |
- |
3X-LK463-BW |
| UK keyboard |
3R-LKQ50-AE |
- |
| Yugoslavian keyboard |
- |
3X-LK463-BY |
| Rackmount Keyboard/Drawer and
Keyboard/Monitor Options |
PS2 to USB Converter
allows for connection of a PS2 keyboard and/or mouse to an AlphaServer ES47 System |
3R-A4495-AA |
|
HP Rackmount Flat Panel Monitor |
3R-A4220-AA |
|
Integrated Keyboard and Drawers |
|
|
Integrated Keyboard and Drawer
(1U), North America |
3R-A4404-AA |
|
Integrated Keyboard and Drawer
(1U), International |
3R-A4405-AA |
|
Integrated Keyboard and Monitor
(TFT5600RKM) |
|
|
Integrated Keyboard and Monitor,
North America |
3R-A3496-AA |
|
Integrated Keyboard and Monitor,
France |
3R-A3709-AA |
|
Integrated Keyboard and Monitor,
Germany |
3R-A3708-AA |
|
Integrated Keyboard and Monitor,
International |
3R-A3498-AA |
|
Integrated Keyboard and Monitor,
Spain |
3R-A3710-AA |
|
Integrated Keyboard and Monitor,
United Kingdom |
3R-A3706-AA |
|
NOTE:
Integrated Keyboard and Drawer and Integrated Keyboard and Monitor require one Keyboard
and Mouse Adapter for USB (3R-A4495-AA) |
|
| Step 15 -
System Software |
| Tru64 UNIX |
- Media and documentation required for first system on site
|
|
- Software Processor Code = E
|
|
- Tru64 UNIX base systems include pre-installed software, Base license, Unlimited User
license, Server Extension license, Internet Express and Secure Web Server
|
|
Tru64 UNIX media and online
documentation on CD-ROM |
QA-6ADAA-H8 |
| Tru64 UNIX full hard copy
documentation |
QA-6ADAA-GZ |
|
TruCluster Plus Software Package
with licenses for TruCluster Server, Logical Storage Manager and AdvFS Utilities |
QP-6R9AE-AA |
|
TruCluster Server license |
QL-6BRAE-AA |
|
Logical Storage Manager license |
QL-2GVAE-AA |
|
AdvFS Utilities license |
QL-0EGAE-AA |
|
Advanced Server for Tru64 UNIX,
25 client concurrent use license |
QL-5U29M-3D |
|
Advanced Server for Tru64 UNIX,
50 client concurrent use license |
QL-5U29M-3E |
|
Advanced Server for Tru64 UNIX,
100 client concurrent use license |
QL-5U29M-3F |
|
Advanced Server for Tru64 UNIX,
250 client concurrent use license |
QL-5U29M-3G |
|
Advanced Server for Tru64 UNIX,
500 client concurrent use license |
QL-5U29M-3H |
|
Layered products media and
documentation for Tru64 UNIX on CD-ROM |
QA-054AA-H8 |
|
DECnet/OSI end-system function
license for Tru64 UNIX |
QL-MTJAE-AA |
|
DECnet/OSI extended license for
Tru64 UNIX |
QL-MTKAE-AA |
| |
| OpenVMS |
- Media and documentation required for first system on site
|
|
- Software Processor Code = E
|
|
- AlphaServer ES47 OpenVMS systems include Base license with System Manager license and
Enterprise Integration Server Package for OpenVMS
-- OpenVMS OS
media on CD-ROM
|
|
- Enterprise Integration Package includes licenses for TCP/IP Services for OpenVMS,
DECwindows Motif for OpenVMS Alpha, DECnet-Plus for OpenVMS Alpha End System,
Archive/Backup System for OpenVMS Management Tools, Archive/Backup Agent for Windows NT?/i>,
Office Server for OpenVMS, Office Server Client Access, PATHWORKS 32, PATHWORKS for
OpenVMS and Advanced Server.
|
|
- OpenVMS Concurrent Use licenses provide the right to interactively use the operating
system by the specified number of concurrent users on a designated OpenVMS system. OpenVMS
Concurrent Use licenses can be moved from one system to another at user discretion and can
be shared in a mixed OpenVMS VAX and OpenVMS Alpha cluster
|
|
- OpenVMS Traditional Unlimited Use license is system specific and can only be used on one
single system at a time. It cannot be shared between systems or in an OpenVMS VAX or
OpenVMS Alpha Cluster
|
|
Concurrent Use 1-user
license |
QL-MT3AA-3B |
|
Concurrent Use 2-user
license |
QL-MT3AA-3C |
|
Concurrent Use 4-user
license |
QL-MT3AA-3D |
|
Concurrent Use 8-user
license |
QL-MT3AA-3E |
|
Concurrent Use
16-user license |
QL-MT3AA-3F |
|
Concurrent Use
32-user license |
QL-MT3AA-3G |
|
Concurrent Use
64-user license |
QL-MT3AA-3H |
|
Concurrent Use
128-user license |
QL-MT3AA-3J |
|
Concurrent Use
256-user license |
QL-MT3AA-3K |
|
Traditional
unlimited-user license |
QL-MT2AE-AA |
|
OpenVMS media and
online documentation on CD-ROM |
QA-MT1AA-H8 |
|
OpenVMS hard copy
documentation |
QA-001AA-GZ |
|
OpenVMS base hard
copy documentation |
QA-09SAA-GZ |
|
OpenVMS Alpha
Software Products Library Package: Layered products media and documentation for OpenVMS on
CD0ROM, includes media and documentation for all products licensed in the Enterprise
Integration Package. |
QA-03XAA-H8 |
|
DECnet-Plus/DECnet
extended function license for OpenVMS |
QL-MTGAE-AA |
|
DECnet-Plus/DECnet
end-system to extended function upgrade license for OpenVMS |
QL-MTHAE-AA |
|
Cluster License for
OpenVMS Alpha |
QL-MUZAE-AA |
|
OpenVMS Volume
Shadowing license |
QL-2A1AE-AA |
|
A more
complete software list can be found at: http://www.openvms.compaq.com/swcat/index.html |
| |
| Step 16 -
Hardware and Software Support Services |
- Select one of the optional CarePaq Priority Service Packages described below that best
supports the customers operational requirements for system availability.
|
| CarePaq Priority
Services |
- CarePaq Priority Services are available for AlphaServer systems running Tru64 UNIX or
OpenVMS operating systems. Priority Services are designed for the growing number of
customers who need support beyond the basic warranty. Five packages are offered -
Priority, Priority 24, Priority Silver, Priority Gold, and Priority Executive with
coverage for both Principal servers systems and SSPs (Subsequent System Packages) - that meet a full range of customer support requirements.
|
|
| |
| Program Features
Principal Server |
| Priority |
|
|
|
- 4-hour response on-site hardware support
|
|
|
- 2-hour response for Bronze software support
|
|
|
- License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
|
| |
| Priority 24 |
|
|
|
|
|
|
- 4-hour response on-site hardware support
|
|
|
- 2-hour response for Bronze software support
|
|
|
- License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
|
|
- Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their
layered products. (Some layered products on Consolidated Media Update Distribution can be
ordered separately.)
|
|
| |
| Priority Silver |
- 24x7 HW Support. Named Engineer, 4-hour response
|
|
|
- 24x7 Silver SW Support - Named Account Rep, 1-hour response Monday Friday,
8AM-5PM local time; 2-hour response remaining hours
|
|
|
- License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
|
|
- Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their
layered products. (Some layered products on Consolidated Media Update Distribution can be
ordered separately.)
|
|
|
- Technical newsletter and SW activity review
|
|
|
- Proactive Patch Notification
|
|
|
- One (1) System Healthcheck per year
|
|
| |
| Priority Gold |
- 24x7 HW support with Named Engineer, 4-hour response for on-site support
|
|
|
- 24x7 Gold SW support - Named Account Rep
|
|
|
- 30-minute callback (critical); 1-hour callback (non-critical)
|
|
|
- License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
|
|
- Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their
layered products. (Some layered products on Consolidated Media Update Distribution can be
ordered separately.)
|
|
|
- Technical newsletter, SW activity review and 10 hours Upgrade impact planning
|
|
|
- Proactive Revision Management
|
|
|
- Two (2) System Healthchecks per year
|
|
|
- Mandatory pre-qualification required
|
|
| |
| Priority Gold
Executive |
- 24x7 HW support with Named Engineer, two-hour response for on-site support
|
|
|
- 24x7 Gold SW support - Named Account Rep
|
|
|
- 30-minute callback (critical); one-hour callback (non-critical)
|
|
|
- License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
|
|
- Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their
layered products. (Some layered products on Consolidated Media Update Distribution can be
ordered separately.)
|
|
|
- Technical newsletter, SW activity review and 10 hours Upgrade impact planning
|
|
|
- Proactive Revision Management
|
|
|
- Two (2) System Healthchecks per year
|
|
|
- Customer site must be within 25 miles of an HP service location
|
|
|
- Mandatory pre-qualification required
|
|
| |
| Program Features
Additional Services |
| SSPs
(Subsequent System Packages) |
- For Priority, Priority 24, Priority Silver, Priority Gold, and Priority Gold Executive
|
|
- HW Support at same level as corresponding package for Principal server
|
|
|
- License Subscription: HP O/S (where applicable)
|
|
|
- Telephone support through Principal server covered by full support package
|
|
| |
| Installation
|
|
|
|
|
|
|
|
|
|
|
|
|
- No software installation added
|
|
| |
| Installation
and Startup HP O/S |
|
|
|
|
|
|
|
|
|
|
|
|
- Install operating systems
|
|
|
|
|
|
|
|
|
|
|
| |
Model/CarePaq
Priority Service |
Principal Server
1 year |
Principal Server
3 years |
Subsequent Systems
1 year |
Subsequent Systems
3 years |
| AlphaServer ES47
Model 2 and Model 4 |
| Priority |
FP-F01GB-12 |
FP-F01GB-36 |
FP-F21GB-12 |
FP-F21GB-36 |
| Priority 24 |
FP-F02GB-12 |
FP-F02GB-36 |
FP-F22GB-12 |
FP-F22GB-36 |
| Priority Silver |
FP-F04GB-12 |
FP-F04GB-36 |
FP-F24GB-12 |
FP-F24GB-36 |
| Priority Gold |
FP-F08GB-12 |
FP-F08GB-36 |
FP-F28GB-12 |
FP-F28GB-36 |
| Priority Gold Exec. |
FP-F09GB-12 |
FP-F09GB-36 |
FP-F29GB-12 |
FP-F29GB-36 |
| Installation |
FP-FINST-GB |
FP-FINST-GB |
FP-FINST-GB |
FP-FINST-GB |
| Installation and
Startup |
FP-FSTAR-GB |
FP-FSTAR-GB |
FP-FSTAR-GB |
FP-FSTAR-GB |
NOTES:
- AlphaServer ES47 Model 2 and 4 systems include one-year parts and labor warranty with
5x9, on-site Next Business Day response.
- Priority Services include support for new HP branded hardware options internal to the
AlphaServer enclosure plus a monitor (17-inch or less excluding flat panel models).
- External storage devices/cabinets carry their own level of warranty and should be quoted
separately for uplifted warranty services.
- Five-year CarePaq Priority Service is available upon request. To quote five-year
service, change the last two part number digits from 12 or 36 to 60.
- In addition to the CarePaq Priority Services, uplifted warranty. Supplemental Services
are available for separate hardware and software support. For more information on Hardware
and Software Supplemental Services and other HP service options available for
AlphaServers, please consult your Sales Account Manager or visit:
http://www.hp.com/services/