contents
 Overview   Standard Features   Systems/Options   Options   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) QuickSpecs

hp AlphaServer ES45

spacerw.gif (802 bytes) 10994_OV.jpg (133496 bytes)
spacerw.gif (802 bytes) At A Glance

AlphaServer ES45 Systems include:

  • Alpha 21264C 68/1000-MHz CPU with 8-MB L2 Dual Data Rate Cache or
  • Alpha 21264D 68/1250-MHz CPU with 16-MB L2 Dual Data Rate Cache
  • Six 64-bit PCI I/O expansion slots for Model 1B (4 slots are PCI hot-plug ready) plus one AGP 4X graphics slot
  • Ten 64-bit PCI I/O expansion slots for Models 2, 2B, and 3B
    (7 slots are PCI hot-plug ready)
  • Up to four PCI buses

Model 1B or Model 1

  • Two 64-bit/66-MHz PCI buses
  • One 64-bit/33-MHz PCI bus
  • One AGP 4X bus

Model 2B or Model 2

  • Three 64-bit/66-MHz PCI buses
  • One 64-bit/33-MHz PCI bus

Model 3B or Model 3

  • One 64-bit/66-MHz PCI bus
  • Three 64-bit/33-MHz PCI buses
  • Up to 32-GB memory using 512-MB, 1-GB, 2-GB, or 4-GB memory options
  • 1.44-MB diskette drive
  • 16X DVD-ROM drive
  • Two 9-pin serial ports
  • One 25-pin parallel port
  • Remote Management Console (RMC) – dedicated serial port, 6-pin MMJ connector
  • Keyboard and mouse port
  • Knockouts for two additional 68-pin external SCSI connections
  • One power supply
  • Integral remote system management console
  • Customer documentation
  • Tru64™ UNIX™ or OpenVMS™ Factory Installed Software
  • Protected by HP Services, including one-year hardware warranty, on-site with 5 x 9 next business day response.
contents
 Overview   Standard Features   Systems/Options   Options   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) Standard Features
Processor Alpha 21264C 68/1000-MHz CPU or Alpha 21264D 68/1250-MHz CPU
  
Cache Memory 8-MB (1 GHz) or 16-MB (1.25 GHz) L2 Dual Data Rate Backup Cache
  
Upgradability Supports additional processors and upgrades of memory and hard drives
  
Memory Minimum 1 GB – AlphaServer ES45
Maximum 16 GB (16 DIMM slots) – Model 1B, or Model 1

32 GB (32 DIMM slots) – Model 2B or Model 2, Model 3B or Model 3

  
Network Controller Choice of Ethernet controllers
  
Expansion PCI I/O slots Up to ten PCI slots – See PCI Configuration Guidelines
   
Storage Diskette Drive 1.44-MB diskette drive in dedicated slot
DVD-ROM Drive 16X DVD-ROM drive
Hard Drives Choice of 18.2-GB, 36.4-GB, 72.8-GB, or 146-GB drives
  
Interfaces Parallel One 25-pin parallel port
Serial Two 9-pin serial ports
Keyboard One port
Mouse One port
Remote Management Console port (RMC) One 6-pin MMJ dedicated port
SCSI connections Knockouts for two additional 68-pin external SCSI connections
  
Graphics Optional
  
Form Factor Tower Up to 12 Universal disk drives
Pedestal Up to 40 Universal disk drives
Rackmount (M-Series Cabinet) Up to 152 Universal disk drives
  
Power Supply One auto sensing power supply, hot swappable, N+1, power factor corrected
  
Manageability Compaq Insight Manager?/font>
   
OS Support AlphaServer ES45 Tru64 UNIX systems include pre-installed software, Base license, Unlimited User license, Server Extension license, Internet Express, and Secure Web Server
AlphaServer ES45 OpenVMS systems include pre-installed software, Base license with System Manager license and Enterprise Integration Server License Package for OpenVMS V3.1
Minimum OS support - Tru64 UNIX V5.1A or OpenVMS V7.3, Linux RedHat V6.2, Linux SuSE V6.3 or greater
  
Service and Support Protected by HP Services including a one-year on-site hardware warranty with next business day response. Training, consulting, network integration, software support, comprehensive system maintenance and guaranteed uptime services are also available for customers requiring higher levels of service and support.
AlphaServer ES45 systems are available in the following models or configurations:
  • Model 1B (1 GHz) or Model 1 (1.25 GHz)
  • Model 2B (1 GHz) or Model 2 (1.25 GHz)
  • Model 3B (1 GHz) or Model 3 (1.25 GHz)

When configuring an AlphaServer ES45 system, refer to the following chart that summarizes the features of each model as well as the differences between each model.

AlphaServer ES45 Model Summary Model 1B (1 GHz)
Model 1
(1.25 GHz)
Model 2B (1 GHz)
Model 2 (1.25 GHz)
Model 3B (1 GHz)
Model 3
(1.25 GHz)
I/O Slots 7 10 10
- 33-MHz PCI Slots 2 4 8
- 66-MHz PCI Slots 4 6 2
- 4X AGP Slots 1 0 0
Hot-swap PCI Slots 4 7 7
Power Supplies (Minimum/Maximum) 1-3 1-3 1-3
Power Supply (DC Watts) One included – maximum three power supplies per system
3X-H7514-AA 3X-H7514-AA 3X-H7514-AA
1080 Watts 1080 Watts 1080 Watts
Memory (Minimum/Maximum) 1 GB – 16 GB 1 GB – 32 GB 1 GB – 32 GB
Memory Option (4-GB Option)
MS620-DB MS620-DB MS620-DB
Higher Power DIMM Higher Power DIMM Higher Power DIMM
Memory Channel I/O Space (CCMAB-AA)
See Memory Channel – Step 9
128K 128K 512K or 128K
NOTE: Minimum firmware for 1.25-GHz systems is V6.2-8, minimum SROM firmware is V2.22-F. Firmware files are available at: http://ftp.digital.com/pub/Digital/Alpha/firmware/interim/es45/v6.2C/
   
PCI Configuration Guidelines
  • Modules designed for 5.0 V signaling and 33-MHz bus speed can only operate in 5.0 V/33-MHz slots
  • Modules designed for 3.3 V signaling and 66-MHz bus speed can only operate in 66-MHz slots
  • Universal PCI modules can operate in all slots (3.3 V and 5.0 V)
  • Universal PCI modules operating at 33 MHz placed in a 66-MHz slot will reduce the entire hose to operate at 33 MHz
  • Universal PCI modules capable of operating at 66 MHz when placed in a 33-MHz slot will operate at 33 MHz
  • PCI hot-plug ready slots are designed to enable PCI modules to be added or removed while the system is powered and running. Subsequent operating system versions above Tru64 UNIX V5.1A and OpenVMS V7.3 will provide support for hot-plug PCI functionality

PCI Module Descriptions:

  • PCI modules listed in this document as 33 MHz or 66 MHz refer to the module’s maximum PCI bus speed.
  • Modules that can only operate at 5 V are designated as 5 V – 33-MHz modules.
  • Universal PCI modules are designated as 3.3/5 V and can be installed into 33-MHz or 66-MHz slots.

AlphaServer ES45 systems provide four I/O hoses, each is configured differently as illustrated in the following charts for Models 1B, 2B, and 3B.

   
AlphaServer ES45 PCI bus and slot specification for Model 1B or Model 1 follows:
PCI Slot PCI Bus Speed Signal Voltage PCI Hot-Plug PCI Hose Number
1 33 MHz 5.0 V No 0
2 33 MHz 5.0 V No 0
3 AGP 4X 1.5 V No 2
4 66 MHz 3.3 V Yes 3
5 66 MHz 3.3 V Yes 3
6 - - - -
7 66 MHz 3.3 V Yes 1
8 66 MHz 3.3 V Yes 1
  
AlphaServer ES45 PCI bus and slot specification for Model 2B or Model 2 follows:
PCI Slot PCI Bus Speed Signal Voltage PCI Hot-Plug PCI Hose Number
1 66 MHz 3.3 V No 2
2 66 MHz 3.3 V No 2
3 33 MHz 5.0 V No 0
4 66 MHz 3.3 V Yes 3
5 66 MHz 3.3 V Yes 3
6 33 MHz 5.0 V Yes 0
7 66 MHz 3.3 V Yes 1
8 66 MHz 3.3 V Yes 1
9 33 MHz 5.0 V Yes 0
10 33 MHz 5.0 V Yes 0
  
AlphaServer ES45 PCI bus and slot specification for Model 3B or Model 3 follows:
PCI Slot PCI Bus Speed Signal Voltage PCI Hot-Plug PCI Hose Number
1 33 MHz 5.0 V No 2
2 33 MHz 5.0 V No 2
3 33 MHz 5.0 V No 0
4 66 MHz 3.3 V Yes 3
5 66 MHz 3.3 V Yes 3
6 33 MHz 5.0 V Yes 0
7 33 MHz 5.0 V Yes 1
8 33 MHz 5.0 V Yes 1
9 33 MHz 5.0 V Yes 0
10 33 MHz 5.0 V Yes 0
contents
 Overview   Standard Features   Systems/Options   Options   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) Systems/Options
Step 1 - Select system
AlphaServer ES45 Model 1B or Model 1, Model 2B or Model 2, and Model 3B Systems require the mandatory selection of the following items. AlphaServer ES45 Base Systems require the selection of a minimum of 1-GB memory in addition to the following mandatory items.
  • Disk drive cage or StorageWorks™ shelf (Step 5)
  • System disk drive (Step 5)
  • Tower, Pedestal, or Rack Kit (Step 6)
  • Ethernet adapter (Step 8)
  • Storage adapter (Step 10)
  • Order country-specific keyboard and mouse only if required (Step 14)
  • Software media and documentation for first system onsite (Step 16)
NOTE: Only 2-5-2 part numbers are factory integrated.
  
AlphaServer ES45 Systems (1000 MHz)
ES45 OS CPU I/O Slots Memory/Cache Order Number
Model 1B Tru64 UNIX 1000 MHz 6 PCI, 1 AGP 4X 1 GB/8 MB DA-66DBA-BA
Model 1B Tru64 UNIX 1000 MHz 6 PCI, 1 AGP 4X 2 GB/8 MB DA-66DBA-CA
Model 1B Tru64 UNIX 1000 MHz 6 PCI, 1 AGP 4X 4 GB/8 MB DA-66DBA-DA
           
Model 1B OpenVMS 1000 MHz 6 PCI, 1 AGP 4X 1 GB/8 MB DY-66DBA-BA
Model 1B OpenVMS 1000 MHz 6 PCI, 1 AGP 4X 2 GB/8 MB DY-66DBA-CA
Model 1B OpenVMS 1000 MHz 6 PCI, 1AGP 4X 4 GB/8 MB DY-66DBA-DA
             
Model 2B Tru64 UNIX 1000 MHz 10 PCI 1 GB/8 MB DA-68DBA-BA
Model 2B Tru64 UNIX 1000 MHz 10 PCI 2 GB/8 MB DA-68DBA-CA
Model 2B Tru64 UNIX 1000 MHz 10 PCI 4 GB/8 MB DA-68DBA-DA
                   
Model 2B OpenVMS 1000 MHz 10 PCI 1 GB/8 MB DY-68DBA-BA
Model 2B OpenVMS 1000 MHz 10 PCI 2 GB/8 MB DY-68DBA-CA
Model 2B OpenVMS 1000 MHz 10 PCI 4 GB/8 MB DY-68DBA-DA
                 
Model 3B Tru64 UNIX 1000 MHz 10 PCI 1 GB/8 MB DA-67DBA-BA
Model 3B Tru64 UNIX 1000 MHz 10 PCI 2 GB/8 MB DA-67DBA-CA
Model 3B Tru64 UNIX 1000 MHz 10 PCI 4 GB/8 MB DA-67DBA-DA
                   
Model 3B OpenVMS 1000 MHz 10 PCI 1 GB/8 MB DY-67DBA-BA
Model 3B OpenVMS 1000 MHz 10 PCI 2 GB/8 MB DY-67DBA-CA
Model 3B OpenVMS 1000 MHz 10 PCI 4 GB/8 MB DY-67DBA-DA
  
AlphaServer ES45 Systems (1250 MHz)
ES45 OS CPU I/O Slots Memory/Cache Order Number
Model 1 Tru64 UNIX 1250 MHz 6 PCI, 1 AGP 4X 1 GB/16 MB DA-66EBA-BA
Model 1 Tru64 UNIX 1250 MHz 6 PCI, 1 AGP 4X 2 GB/16 MB DA-66EBA-CA
Model 1 Tru64 UNIX 1250 MHz 6 PCI, 1 AGP 4X 4 GB/16 MB DA-66EBA-DA
                 
Model 1 OpenVMS 1250 MHz 6 PCI, 1 AGP 4X 1 GB/16 MB DY-66EBA-BA
Model 1 OpenVMS 1250 MHz 6 PCI, 1 AGP 4X 2 GB/16 MB DY-66EBA-CA
Model 1 OpenVMS 1250 MHz 6 PCI, 1 AGP 4X 4 GB/16 MB DY-66EBA-DA
                 
Model 2 Tru64 UNIX 1250 MHz 10 PCI 1 GB/16 MB DA-68EBA-BA
Model 2 Tru64 UNIX 1250 MHz 10 PCI 2 GB/16 MB DA-68EBA-CA
Model 2 Tru64 UNIX 1250 MHz 10 PCI 4 GB/16 MB DA-68EBA-DA
                 
Model 2 OpenVMS 1250 MHz 10 PCI 1 GB/16 MB DY-68EBA-BA
Model 2 OpenVMS 1250 MHz 10 PCI 2 GB/16 MB DY-68EBA-CA
Model 2 OpenVMS 1250 MHz 10 PCI 4 GB/16 MB DY-68EBA-DA
                 
Model 3 Tru64 UNIX 1250 MHz 10 PCI 1 GB/16 MB DA-67EBA-BA
Model 3 Tru64 UNIX 1250 MHz 10 PCI 2 GB/16 MB DA-67EBA-CA
Model 3 Tru64 UNIX 1250 MHz 10 PCI 4 GB/16 MB DA-67EBA-DA
                   
Model 3 OpenVMS 1250 MHz 10 PCI 1 GB/16 MB DY-67EBA-BA
Model 3 OpenVMS 1250 MHz 10 PCI 2 GB/16 MB DY-67EBA-CA
Model 3 OpenVMS 1250 MHz 10 PCI 4 GB/16 MB DY-67EBA-DA
   
AlphaServer ES45 Base Systems (1000 MHz)
NOTE: Selection of a minimum of 1-GB memory is mandatory for AlphaServer ES45 Base systems.
ES45 OS CPU/Cache I/O slots Order Number
Model 1B Tru64 UNIX 1000 MHz/8 MB 6 PCI, 1 AGP 4X DA-66DBA-AA
Model 1B OpenVMS 1000 MHz/8 MB 6 PCI, 1 AGP 4X DY-66DBA-AA
               
Model 2B   Tru64 UNIX 1000 MHz/8 MB 10 PCI DA-68DBA-AA
Model 2B OpenVMS 1000 MHz/8 MB 10 PCI DY-68DBA-AA
                  
Model 3B Tru64 UNIX 1000 MHz/8 MB 10 PCI DA-67DBA-AA
Model 3B OpenVMS 1000 MHz/8 MB 10 PCI DY-67DBA-AA
     
AlphaServer ES45 Base Systems (1250 MHz)
Model 1 Tru64 UNIX 1250 MHz/16 MB 6 PCI, 1 AGP 4X DA-66EBA-AA
Model 1 OpenVMS 1250 MHz/16 MB 6 PCI, 1 AGP 4X DY-66EBA-AA
                 
Model 2 Tru64 UNIX 1250 MHz/16 MB 10 PCI DA-68EBA-AA
Model 2 OpenVMS 1250 MHz/16 MB 10 PCI DY-68EBA-AA
                
Model 3 Tru64 UNIX 1250 MHz/16 MB 10 PCI DA-67EBA-AA
Model 3 OpenVMS 1250 MHz/16 MB 10 PCI DY-67EBA-AA
contents
 Overview   Standard Features   Systems/Options   Options   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) Options
Step 2 - Additional CPU Modules - Optional
  • One CPU included, three additional CPUs are supported
SMP upgrade, includes one 68/1000-MHz CPU with 8-MB cache and Tru64 UNIX SMP license KN610-DB
SMP upgrade, includes one 68/1000-MHz CPU with 8-MB cache and OpenVMS SMP license KN610-DC
SMP upgrade, includes one 68/1250-MHz CPU with 16-MB cache and Tru64 UNIX SMP license KN610-EB
SMP upgrade, includes one 68/1250-MHz CPU with 16-MB cache and OpenVMS SMP license KN610-EC
NOTE: Minimum firmware for 1.25-GHz systems is V6.2-8, minimum SROM firmware is V2.22-F. Firmware files are available at: http://ftp.digital.com/pub/Digital/Alpha/
firmware/interim/es45/v6.2C/
NOTE: Existing AlphaServer ES45 1-GHz Model 2 (xx-68DAA-xx) customers who upgrade to 1.25-GHz CPUs, should continue to follow Model 2 configuration guidelines. The following options are required: H7906-A9 power supply and MS620-AA, MS620-BA, and MS620-CA memory options. Do not order 3X-H7514-AA power supplies or MS5620-DB memory options.
   
Step 3 - Memory - Optional
  • Base systems do not include memory; select a minimum of 1-GB memory; this is a mandatory selection. All other systems include one memory option.
  • Maximum four memory options (total of 16 DIMMs) for Model 1B or Model 1 (one per array)
  • Maximum eight memory options (total of 32 DIMMs) for Models 2B or Model 2, and Model 3B or Model 3 (two per array)
  • AlphaServer ES45 system includes two memory buses
  • AlphaServer ES45 system includes two arrays per bus
  • For Model 2B or Model 2 and Model 3B or Model 3, memory options within an array must be identical
512-MB memory option (4 x 128-MB DIMMs) MS620-AA
1-GB memory option (4 x 256-MB DIMMs) MS620-BA
2-GB memory option (4 x 512-MB DIMMs) MS620-CA
4-GB memory option (4 x 1024-MB DIMMs)

NOTE: Do not order MS620-DB memory option for installation in ES45 1-GHz Model 2
(xx-68DAA-xx) system. MS620-DB memory option can only be installed in
(xx-6xDBA-xx) and (xx-6xEBA-xx) systems.

MS620-DB
Memory performance considerations:
  • The AlphaServer ES45 system has two memory buses. When two or more memory options are installed, both buses are utilized, enhancing system performance
  • The AlphaServer ES45 system has two arrays per bus. Interleaved operations reduce the average latency and increase the memory throughput. When all four arrays are populated with the same amount of memory, read-write operations are four-way interleaved, enhancing system performance.

The following examples illustrate different ways of configuring a 4-GB system. Case C yields the best performance and is the recommended method for configuring memory on an AlphaServer ES45 system.

ES45 System
(one memory option included)
Add-on Memory Options Total Memory Total DIMMs Performance
Case A - DA-68DBA-DA (MS620-DB) None 4-GB 4 Good
Case B - DA-68DBA-CA (MS620-CA) MS620-CA 4-GB 8 Better
Case C - DA-68DBA-BA (MS620-BA) MS620-BA + MS620-BA + MS620-BA 4-GB 16 Best *
  
NOTE: * = Operating system and application dependent. Up to an 18% performance enhancement has been measured in Case C over Case A.
  
Step 4 - Additional Power Supply - Optional
One Power Supply Standard with Model 1B or 1, 2B or 2, and 3B or 3 systems; provides system support for:
  • Two CPUs
  • One disk drive cage (up to six disk drives)
  • Four memory options (up to 16 DIMMs)
Two Power Supplies Optional – Provides system support for:
  • Four CPUs
  • Two disk drive cages (up to 12 disk drives)
  • Eight memory Options (up to 32 DIMMs)
Third Power Supply Optional - Provides (N+1) power redundancy system support for two power supply configuration
   
  • Additional power supply ordered with a tower system requires an additional country-specific power cord
  • Pedestal system and Rack kit include three internal IEC/IEC power cords regardless of the number of power supplies ordered
ES45 1080 W power supply; order for Models 1B, 2B, and 3B
(1-GHz) and Models 1, 2, and 3 (1.25-GHz) systems only; do not order for Model 2 (xx-68DAA-xx) systems.

3X-H7514-AA

ES45 720 W power supply; order for Model 2
(1-GHz xx-68DAA-xx) systems only

H7906-A9

    
Step 5 - Disk Drive Cage, Universal Drive Shelf, or Universal Disk Drive - Mandatory
    • Each system supports up to two disk drive cages
  • Each disk drive cage supports six 1-inch universal disk drives
  • 43xx StorageWorks shelves support up to 14 universal disk drives
  • Pedestal enclosure supports one system and two disk drive cages, two Universal 43xx StorageWorks shelves
  • M-Series cabinets supports up to five systems or one system with up to ten StorageWorks shelves
   
Step 5a - Disk Drive Cage - Requires selection of system disk drive
Disk drive cage with storage cable accommodates up to six internal 1-inch Universal disk drives – Requires mandatory selection of a Storage Adapter in the system. Requires an internal Ultra2 SCSI or Ultra3 SCSI channel per disk drive cage. Maximum of two storage cages in system.

BA610-6D

NOTE: See ES45 Configuration Chart for Storage Adapters in Step 10.
    
Universal Disk Drives
(Supported in Disk Drive Cage and Universal StorageWorks Shelves)
18.2-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive

3R-A3848-AA

36.4-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive

3R-A3838-AA

36.4-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive

3R-A3849-AA

72.8-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive

3R-A3839-AA

72.8-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive

3R-A3851-AA

146-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive

3R-A3841-AA

   
Step 5b - StorageWorks Model 4314R and Model 4354R Universal Drive Shelves
  • Up to two shelves in Pedestal form factor
  • See Step 7 for rack configurations with M-Series cabinets
  • StorageWorks Model 4314R, 4314T and 4354R Ultra3 SCSI (LVD) single-bus and split-bus Universal drive shelves; refer to StorageWorks Enclosure 4300 Family QuickSpecs when configuring shelves. When selecting a DS-SL13R-xx split-bus shelf, two SCSI channels are required from selected storage adapters. BN38C-05 cable is required per channel if the connection is not VHDCI/VHDCI. DS-SL13R shelves include one 12-foot VHDCI/VHDCI SCSI cable.
StorageWorks Model 4314R Ultra3 SCSI (LVD) single-bus Universal drive rackmount shelf, includes one power supply, U.S. - no support for Model 4314R single-bus shelves with 3X-KZPEA-DB adapter (190209-001)

DS-SL13R-AA

StorageWorks Model 4314R Ultra3 SCSI (LVD) single-bus Universal drive rackmount shelf, includes one power supply, Japan - no support for Model 4314R single-bus shelves with 3X-KZPEA-DB adapter (190209-291)

DS-SL13R-AJ

StorageWorks Model 4354R Ultra3 SCSI (LVD) split-bus Universal drive rackmount shelf, includes two redundant power supplies, U.S. (190211-001)

DS-SL13R-BA

StorageWorks Model 4354R Ultra3 SCSI (LVD) split-bus Universal drive rackmount shelf, includes two redundant power supplies, Japan (190211-291)

DS-SL13R-BJ

To add additional power supply for single-bus Universal shelf, U.S. (212980-B21)

DS-SE2UP-AA

To add additional power supply for single-bus Universal shelf, International
(119826-B31)

DS-SE2UP-AI

   
StorageWorks Model 4314T Standalone Enclosures Model 4314T Ultra3 SCSI, Single-bus Tower Enclosure, U.S. (190210-001)

DS-SL13T-AA

Model 4314T Ultra3 SCSI, Single-bus Tower Enclosure, International (190210-B31)

DS-SL13T-AB

Model 4314T Ultra3 SCSI, Single-bus Tower Enclosure, Japan (190210-291)

DS-SL13T-AJ

   
Step 6 - System Enclosures - Mandatory selection of Tower, Pedestal, Rack Kit, Power Cords
  • All AlphaServer ES45 enclosures are carbon black
  • Power cords are mandatory for tower and pedestal enclosures
  • Power cords are included in Rack Kits
   
Step 6a - Tower Enclosure
  • Tower enclosure supports one system

Selection of one country-specific power cord is mandatory

  • Additional power cord is mandatory if additional power supply is ordered.
200–240V Tower Enclosure

BA61M-CT

   
Step 6b - Pedestal Enclosure
  • Pedestal enclosure supports one system, and up to two Universal 43xx StorageWorks shelves.
  • Selection of two country-specific power cords is mandatory for all systems.
200–240V Pedestal Enclosure

BA61P-CB

   
Step 6c - Rack Kit for M-Series Cabinet
  • Rack Kit required for each AlphaServer ES45 system installed in an M-Series Cabinet
  • Rack Kit supports one system
Rack kit for AlphaServer ES45, includes dress bezel, slides, three internal IEC/IEC power cords, all brackets and hardware for mounting in M-Series cabinets, 200-240V

BA61R-CR

   
Step 6d - Power Cords
North American 200 to 240V, 75-inch - Tower

BN18J-1K

North American 200 to 240V, 108-inch - Pedestal

3X-BN64A-1C

Australia, New Zealand, 2.5-meter (103541-011)

BN19H-2E

Central Europe, 2.5-meter

BN19C-2E

Denmark, 2.5-meter (103541-481)

BN19K-2E

Egypt, India, South Africa, 2.5-meter (103541-AR1)

BN19S-2E

Israel, 2.5-meter

BN18L-2E

Italy, 2.5-meter (103541-461)

BN35M-02

Japan, 2.5-meter, Dentori approved

3X-BN46F-02

Switzerland, 2.5-meter (103541-511)

BN19E-2E

UK, Ireland, 2.5-meter

BN19A-2E

Republic of China (103541-001)

BN19H-2E

    
Step 7 - M-Series Cabinets
  • M-Series Cabinet enclosures support up to five systems, or one system with up to ten StorageWorks shelves.
  • M-Series Cabinets require mandatory selection of the following items:
  • Rear cabinet extender based on cabinet height
  • Cabinet front door or trim kit based on cabinet height
  • Second power distribution unit (PDU) – M-Series Cabinets include one H7602 PDU
  • Factory integration
  • Ballast kit, if only one system is ordered for the H9A15 cabinet
NOTE: For additional configurations beyond those listed in the following charts, contact CustomSystems.
   
Cabinet Configuration Chart for AlphaServer ES45 (8U) with 43xx Series StorageWorks Shelves (3U) – Supports high-density configurations
Cabinet (b) Front Door
or Trim Kit
Cabinet Depth
Extender
Power Distribution
Unit
ES45
Systems
43xx Storage Shelves Unused U Spaces
H9A10-ME/-MF

H9C10-ZF
or
H9C10-ZT

H9C10-ZE

With second H7600

1

8

1

(34U)

2

5

2

3

3

0

4

0

1

H9A15-ME/-MF

H9C15-ZF
or
H9C15-ZT

H9C15-ZE

With second H7600

1 (a)

10

2

(41U)

2

8

0

3

3

7

4

0

8

(b)

3

3 or 5

1

With second H7602

4

0 or 2

2

5

0

0

NOTES:
  1. Installation of only one AlphaServer ES45 system in an H9A15 cabinet requires the mandatory selection of a ballast kit.
  2. H9A1x-ME includes one H7602-EB PDU; H9A1x-MF includes one H7602-DB PDU – Order second PDU.
    - Single Input - H7600-DB/EB, 240V
    - Dual Input - H7602-DB/EB, 240V
   
M-Series Cabinets - Specify cabinet selection 67-inch carbon black cabinet with 59.5-inch or 34U of usable vertical space, 200-240V dual-16A PDU, 16 IEC C13 outlets, two input power plug NEMA L620P, Americas, Asia Pacific; includes rear door.

H9A10-ME

67-inch carbon black cabinet with 59.5-inch or 34U of usable vertical space, 240V dual-16A PDU, 16 IEC C13 outlets, two input power plug IEC 309, 20A, Europe; includes rear door.

H9A10-MF

79-inch carbon black cabinet with 71.7-inch or 41U of usable vertical space, 200-240V dual-16A PDU, 16 IEC C13 outlets, two input power plug NEMA L620P, Americas, Asia Pacific; includes rear door.

H9A15-ME

79-inch carbon black cabinet with 71.7-inch or 41U of usable vertical space, 240V dual-16A PDU, 16 IEC C13 outlets, two input power plug IEC 309, 20A, Europe; includes rear door.

H9A15-MF

   
Rear Cabinet Extender - Mandatory based on cabinet height Rear cabinet extender for carbon black H9A10 cabinets

H9C10-ZE

Rear cabinet extender for carbon black H9A15 cabinets

H9C15-ZE

   
Front Cabinet Treatment - Mandatory based on cabinet height Front door for carbon black H9A10 cabinet enclosure

H9C10-ZF

Front trim kit for carbon black H9A10 cabinet enclosure

H9C10-ZT

Front door for carbon black H9A15 cabinet enclosure

H9C15-ZF

Front trim kit for carbon black H9A15 cabinet enclosure

H9C15-ZT

   
Factory Integration - Mandatory Factory Integration of systems and storage devices assembled and configured in cabinet enclosure in predefined locations

YS-ASCAA-AA

    
Ballast Kit - Mandatory if only one ES45 system drawer is ordered for the H9A15 cabinet
  • Ballast is added to a cabinet at particular locations for specific configurations to meet safety regulations for installation, operation, and service; see Cabinet Configuration Charts.
Two 35–40 lb (16–18 kg) steel plates

H9C10-MC

   
Power Distribution Unit - Mandatory 240V single 16A input power plug IEC 309, 12 IEC C13 outlets

H7600-DB

200–240V single 16A input power plug NEMA L620P, with 12 IEC C13 outlets,
North America/Canada/Japan

H7600-EB

240V dual 16A input power plugs IEC 309, with 16 IEC C13 outlets

H7602-DB

200–240V dual 16A input power plugs NEMA L620P, with 16 IEC C13 outlets, NA/Canada/Japan

H7602-EB

   
Storage Shelves Supported in
M-Series Cabinets -
Optional
For supported StorageWorks shelves, see Step 5b.
   
Step 8 - Networking Adapters/Controllers – Mandatory Ethernet Adapter
Step 8a – Networking Adapters/Controllers – Mandatory
  • Select mandatory Ethernet adapter
  • Adapters require a minimum of Tru64 UNIX V5.1A or OpenVMS V7.3
  • Each adapter uses one PCI slot
   
  Maximum # Supported  
  Tru64 UNIX Open
VMS
PCI Slot  
Ethernet 10/100/1000 PCI (32/64-bit, 33-MHz to 66-MHz) dual-port 10/100 Ethernet (UTP/RJ45s) NIC and Base Module. (One 3X-DE602-TA or 3X-DE602-FA optional add-on daughter card can be combined with this module.)
NOTE: Use BN25G, BN26M, BN24Q, BN28Q twisted pair RJ45 cables.
4 4 3.3/5 V 66 MHz

3X-DE602-BB

  
Step 8b – Networking Adapters/Controllers – Optional
Ethernet 10/100/1000 PCI-X/PCI single-port 1000 Mbps (MMF with duplex-SC) Gigabit Ethernet; Tru64 UNIX V5.1B/TruCluster V5.1B supports up to eight nodes and requires:
http://ftp1.support.compaq.com/
public/unix/v5.1b/t64v51bb1-
c0003000-16672-e-
20030130.README

Tru64 UNIX V5.1A/TruCluster V5.1A supports up to eight nodes and requires: T64V51AAB21AS0004-20030206.tar
NOTE: Use BN34A, BN34B, or equivalent with SC connectors.
8 - 3.3/5 V 66 MHz 3X-DEGXA-SA
PCI-X/PCI single-port 10/100/1000 Mbps (Twisted-Pair Copper with RJ45) Gigabit Ethernet; Tru64 UNIX V5.1B/TruCluster V5.1B supports up to eight nodes and requires:
http://ftp1.support.compaq.com/
public/unix/v5.1b/t64v51bb1-
c0003000-16672-e-
20030130.README

Tru64 UNIX V5.1A/TruCluster V5.1A supports up to eight nodes and requires: T64V51AAB21AS0004-20030206.tar
NOTE: Use BN25G, BN26M, BN24Q, BN28Q twisted pair RJ45 cables.
8 - 3.3/5 V 66 MHz 3X-DEGXA-TA
               
Ethernet 10/100 Dual-port 10/100 Ethernet (UTP/RJ45) add-on daughter card for use with the 3X-DE602-BB only. The combined 3X-DE602-BB and 3X-DE602-TA modules, running at 66MHz, provide four 10/100 (UTP/RJ45s) ports in a single PCI slot option; allows for a maximum of 16 ports per system.
OpenVMS V7.3 requires Tima Kit:
DEC-AXPVMS-VMS73_
LAN-V0100—4.PCSI
NOTE: 3X-DE602-TA cannot be used standalone. Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
4 4 3.3/5 V 66 MHz 3X-DE602-TA
Single-port 100 Mbps (MMF/duplex-SC) add-on daughter card for use with the 3X-DE602-BB. The combined 3X-DE602-BB and 3X-DE602-FA modules, running at 66 MHz, provide two 10/100 (UTP/RJ45s) and one 100Mbps (MMF/SC) ports in a single PCI slot option.
NOTE: 3X-DE602-FA cannot be used standalone. Use BN34A or BN34B cables.
4 1
per
3X-
DE602
-BB
3.3/5 V 66 MHz 3X-DE602-FA
 
Multi-function Module

 

PCI 32-bit, 33-MHz multi-function (single-port 10/100 Ethernet UTP/RJ45, Ultra2 LVD SCSI, and 2D graphics) adapter. Model 1 or 1B requires installation on PCI Bus 0 in slots 1 or 2; Model 2 or 2B 1B requires installation on PCI Bus 0 in slots 3, 6, 9, or 10
NOTE: Tru64 UNIX V5.1A requires Patch Kit 3:
T64V51AS0003-20010413.tar. Only one 3X-KZPEA-DB allowed on same PCI bus; no multi-head graphics support; TruCluster support restricted to non-shared SCSI buses only.

Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.

1 1 5V 33 MHz

3X-DEPVZ-AA

3X-DEPVZ-AA specific-use 3-meter LVD2 SCSI cable         BN37A-03
                       
FDDI PCI (32-bit, 33-MHz) to FDDI SAS (MMF/duplex-SC) NIC
Use BN34A, BN34B, or BN34D cables.
4 4 3.3/5 V 33 MHz 3X-DEFPA-AC
PCI (32-bit, 33-MHz) to FDDI DAS (MMF/duplex-SC) NIC
Use BN34A, BN34B, or BN34D cables.
4 4 3.3/5 V 33 MHz 3X-DEFPA-DC
PCI (32-bit, 33-MHz) to FDDI DAS (UTP/RJ45) NIC
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
4 4 3.3/5 V 33 MHz 3X-DEFPA-MC
PCI (32-bit, 33-MHz) to FDDI SAS (UTP/RJ45) NIC
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
4 4 3.3/5 V 33 MHz 3X-DEFPA-UC
                
FDDI-specific Cables Multimode fiber optic (MMF) 62.5/125um duplex cable with SC-to-MIC connectors
xx = available lengths: (01, 03, and 10) for 1, 3, and 10 meters
        BN34D-xx
                  
ATM PCI (32-bit, 33-MHz) to 155 Mbps ATM, Copper NIC with RJ45 connector
Use BN25G-xx, or BN26M-xx cables.
6 6 3.3/5 V 33 MHz 3X-DAPBA-UA
PCI (32-bit, 33-MHz) to 155 Mbps ATM Fiber NIC with SC connector
Use BN34B-xx cable.
6 6 3.3/5 V 33 MHz 3X-DAPBA-FA
PCI (32- bit, 33-MHz) to 622 Mbps ATM Fiber NIC with SC connector
Use BN34B-xx cable.
4 - 3.3/5 V 33 MHz 3X-DAPCA-FA
             
Synchronous Communications PCI (32-bit, 33-MHz) to Dual-port Intelligent Synchronous Communications NIC – Requires at least one (maximum two) 3X-BC34x sync cable listed below. 4 4 3.3/5 V 33 MHz 3X-PBXDD-AA
PCI (32-bit, 33-MHz) to Quad-port Intelligent Synchronous Communications NIC – Requires at least one (maximum four) 3X-BC34x sync cable listed below. 4 4 3.3/5 V 33 MHz 3X-PBXDD-AB
                   
Synchronous-
specific Cables
EIA-530 Single-port cable     3X-BC34G-06
V.24/EIA-232 Single-port cable    3X-BC34L-06
V.11/x.21 Single-port cable   3X-BC34S-06
V.35 Single-port cable   3X-BC34T-06
               
Asynchronous Communications PCI (32-bit, 33-MHz) to 4-port Async Communications NIC with DB-25 octopus cable
NOTE: The UNIX driver (UNIX Tar File 4001180K.tar) is located at:
http://support.digi.com/
support/indexes/
tru64-xr.html

The OpenVMS driver kit (Filename 4001778L.bin) is located at
http://support.digi.com/
support/drivers/
vms/index-async.html
2 2 3.3/5 V 33 MHz

PBXDA-BA

  PCI (32-bit, 33-MHz) to 8-port Async Communications NIC with DB-25 octopus cables
NOTE: The UNIX driver (UNIX Tar File 4001180K.tar) is located at:
http://support.digi.com/
support/indexes/
tru64-xr.html

The OpenVMS driver kit (Filename 4001778L.bin) is located at
http://support.digi.com/
support/drivers/
vms/index-async.html
2 2 3.3/5 V 33 MHz

PBXDA-BB

  PCI (32-bit, 33-MHz 5.0 Volt Bus-Signaling only) to 4-port Async Communications NIC with DB-25 octopus cable 2 2 3.3/5 V 33 MHz PBXDA-AA
  PCI (32-bit, 33-MHz 5.0 Volt Bus-Signaling only) to 8-port Async Communications NIC with DB-25 octopus cables 2 2 3.3/5 V 33 MHz PBXDA-AB
  PCI (32-bit, 33-MHz) to 16-port Async Communications Controller and tabletop 16-port distribution box with RJ45 connectors. 2 2 3.3/5 V 33 MHz PBXDA-AC
                 
Asynchronous Connector Adapters RJ45-to-DB-25 Converter Cable         CXI01-AC
RJ45-to-DEC MJ11 Converter Cable (8 pack)         CXI01-AF
    
Step 8c – Multi-use Cables
    Maximum # Supported    
    Tru64 UNIX Open
VMS
PCI Slot    
Ethernet, FDDI, ATM Multimode fiber optic (MMF) 62.5/125um duplex cable, with SC-to-ST connectors. Xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, and 30 meters        BN34A-xx
Multimode fiber optic (MMF) 62.5/125um duplex cable, with SC-to-SC connectors. Xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5,
1, 3, 10, 20, and 30 meters
      BN34B-xx
Category 5e (4-Unshielded Twisted Pairs / UTP) straight-through cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity. Xx = available lengths: (0B, 0E, 01, 03, 04, 07) for 0.2, 0.5, 1, 3, 4, and 7 meters       BN25G-xx
Category 5e (4-Twisted Pairs, Screened/ ScTP) straight-through cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity. Xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters       BN26M-xx
Category 5e (4-Unshielded Twisted Pairs / UTP) Xover cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity.
Xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters
         BN24Q-xx
Category 5e (4-Twisted Pairs, Screened / ScTP) Xover cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity.
Xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters
      BN28Q-xx
   
Step 9 - MEMORY CHANNEL - Optional
Tru64 UNIX Systems (V5.1A) Each system node in the cluster requires a TruCluster software license
(QL-6BRAE-AA) or TruCluster Plus Software Package (QP-6R9AE-AA)
  
OpenVMS Systems OpenVMS V7.3 and OpenVMS Cluster license (QL-MUZAE-AA) are required
   
Configuring Information
  • Up to two PCI-to-System Area Network adapters (CCMAB-AA) are supported in a single system.
  • Two-node clusters can be configured by ordering a CCMAB-AA for each node and one BN39B-04 or BN39B-10 cable; cable connects directly to CCMAB-AA in each node.
  • Two-node clusters can also be configured by ordering two CCMAB-A adapters for each node and two BN39B-04 or BN39B-10 cables; cables connect directly to CCMAB-AA in each node.
  • For a two-node cluster that will not need to be rebooted when adding additional members, order one CCMAB-AA adapter and one BN39B-04 or BN39B-10 cable for each node, and one CCMHB-AA hub for the cluster.
  • For three- or four- node clusters, order one CCMAB-AA adapter and one
    BN39B-04 or BN39B-10 cable for each node, and one CCMHB-AA hub for the cluster. If two CCMAB-AAs are configured in each system, a second CCMHB-AA is required.
  • CCMHB-AA includes four CCMLB-AA line cards and supports up to four nodes; expansion up to eight system nodes can be achieved by adding up to four CCMLB-AA line cards.
  • If nodes must be separated by a distance longer than standard copper cables allow the CCMFB option converts the output of the standard CCMAB controller or CCMLB line card to single-mode fiber optic cable. The fiber optic connection may be up to 2,000 meters long between two CCMAB controllers connected in virtual hub mode, or 3,000 meters between a CCMAB controller and a CCMHB hub. (The connection from the CCMHB hub to a second system may also be 3,000 meters.) The CCMFB option requires a second PCI slot in the system from which it draws power only. It is normally connected to the corresponding CCMAB controller with the short BN39B-01 cable. The CCMFB is also used in the CCMHB hub where it occupies a slot normally used by the CCMLB line card, limiting expansion to four radial fiber optic connections.
  • CCMHB-BA hub expansion box provides additional slots for up to eight fiber optic connections. Two standard length single-mode fiber optic cables are available (BN34R-10 and BN34R-31); however, users normally provide this fiber optic connection. Fiber optic connectivity is completely transparent to the systems using it and has no performance impact.
NOTE: When configuring Model 1B or Model 1, Model 2B or Model 2 with two Memory Channel Controllers (CCMAB-AA) installed in hose 0 only, all nodes in a Memory Channel cluster must have the window size jumper set to the same size, specifically 128. When configuring Model 3B or Model 3 with two Memory Channel Controllers (CCMAB-AA), all nodes in a Memory Channel cluster must have the window size jumper set to the same size, specifically 512 or 128; Memory Channel Hub must be installed on a different hose (hose 0, 1, or 2). Refer to the TruCluster QuickSpecs for Memory Channel details.
   
Model 1B (1 GHz)
Model 1 (1.25 GHz)
Model 2B (1 GHz)
Model 2 (1.25 GHz)
Model 3B (1 GHz)
Model 3 (1.25 GHz)
128K I/O 128K I/O 512K or 128K I/O
Use for new or existing clusters; if existing cluster at 512K, shut down and configure all nodes to 128K Use for new or existing clusters; if existing cluster at 512K, shut down and configure all nodes to 128K Online add-on to existing 512K configured clusters, OR, use for existing clusters at 128K. If existing cluster at 512K, shut down and configure all nodes to 128K
Supports dual-rail, (two)

Memory Channel controllers on single PCI Bus 0

Supports dual-rail, (two)
 
Memory Channel controllers on single PCI Bus 0
Supports dual-rail, (two)
Memory Channel controllers on separate PCI Bus (0, 1, or 2)
   
MEMORY CHANNEL Controller/ System Area Network Hub PCI-to-System Area Network Controller, maximum two – 5V/33 MHz

CCMAB-AA

System Area Network Hub with four line cards; includes BN19P-2E power cord for Canada, Japan, and U.S. - for other regions, order appropriate power cord from the following list:

CCMHB-AA

Hub expansion box with no line cards

CCMHB-BA

Expansion line card for CCMHB hub

CCMLB-AA

1-meter cable for CCMAB and CCMHB

BN39B-01

4-meter cable for CCMAB and CCMHB

BN39B-04

10-meter cable for CCMAB and CCMHB

BN39B-10

Copper-to-single mode fiber optic converter - 5V (clock not affected)

CCMFB-AA

Rackmount kit (3U) for CCMHB (Memory Channel Hub II); required for mounting in H9A1x cabinets.

3X-BA61R-MC

Power cord for rackmount CCMHB hub

BN35S-02

   
MEMORY CHANNEL Power Cords Australia, New Zealand (103541-011)

BN19H-2E

Central Europe

BN19C-2E

Denmark (103541-481)

BN19K-2E

Egypt, India (103541-AR1)

BN19S-2E

Ireland, United Kingdom

BN19A-2E

Israel

BN18L-2E

Italy (103541-461)

BN35M-02

Japan, 2.5-meter, Dentori approved

3X-BN46F-02

Switzerland (103541-511)

BN19E-2E

Republic of China (103541-001)

BN19H-2E

NOTE: When using MEMORY CHANNEL, refer to the TruCluster QuickSpecs for configuration guidelines and restrictions: http://www.compaq.com/products/quickspecs/Division/10657.html
The MEMORY CHANNEL controller, CCMAB-AA, must be revision D01 or later.
NOTE: This website is available in English only.
   
Step 10 - Storage Adapters/Controllers - Mandatory
NOTE: Refer to the following chart when configuring adapters, shelves, and disks.
AlphaServer ES45 Configuration Chart for Storage Adapters
Storage Adapter Shelf Disk Drive Tru64 UNIX OpenVMS Linux
3X-KZPCA-AA BA610-6D
DS-SL13R-xx
3R-A0xxx-AA 1-inch Universal
3R-A1xxx-AA 1-inch Universal
3R-A3xxx-AA 1-inch Universal
V5.1A V7.3 RedHat V6.2
SuSE V6.3
Requires BA610
3.3/5 V 33 MHz
3X-KZPEA-DB BA610-6D
DS-SL13R-Bx
3R-A0xxx-AA 1-inch Universal
3R-A1xxx-AA 1-inch Universal
3R-A3xxx-AA 1-inch Universal
V5.1A V7.3 -
3.3/5 V 66 MHz
3X-KZPBA-CC External HSZ80 DS-RZ1xx-VW V5.1A V7.3 -
3.3/5 V 33 MHz
DS-KGPSA-DA External HSG80 3R-A0xxx-AA 1-inch Universal
3R-A1xxx-AA 1-inch Universal
3R-A3xxx-AA 1-inch Universal
V5.1A V7.3 -
3.3/5 V 66 MHz
RAID Controller
DS-KZPCC-AC/CE BA610-6D
DS-SL13R-xx
3R-A0xxx-AA 1-inch Universal
3R-A1xxx-AA 1-inch Universal
3R-A3xxx-AA 1-inch Universal
V5.1A - -
3X-KZPDC-BE/DF BA610-6D
DS-SL13R-xx
3R-A0xxx-AA 1-inch Universal
3R-A1xxx-AA 1-inch Universal
3R-A3xxx-AA 1-inch Universal
V5.1B/V5.1A V7.3-1
DS-SWLA4-PD     - - RedHat V7.2
   
  Maximum # Supported
  Tru64 UNIX Open
VMS
PCI
Slot
SCSI PCI 2-port Ultra3 (LVD2) SCSI adapter, 64-bit/66-MHz dual-channel (uses one PCI slot); includes internal 68-pin and external 68-pin VHDCI connectors; requires 3X-BC56J-xx cable to connect adapter to DS-SL13R-Bx shelf; supports internal SDLT tape drives and external SDLT tape libraries. HSZxx RAID controllers not supported. No support for Model 4314R single-bus shelves with 3X-KZPEA-DB adapter. Tru64 UNIX requires graphics adapter to run console utilities (RUN BIOS).
3X-KZPEA-DB adapter supports shared SCSI under Tru64 UNIX V5.1B and TruCluster V5.1B with Initial Patch Kit installed; supports maximum of two nodes per shared bus; requires
3X-BN55A-01 Y-cable and connector plug assembly, and
3X-H32CT-AA external LVD terminator per shared bus.

NOTE: Tru64 UNIX Initial Patch Kit for V5.1B is located at:
http://ftp1.support.compaq.com/
public/unix/v5.1b
6 6 3.3/
5 V
66 MHz

3X-KZPEA-DB

  Ultra160 cable, VHDCI to VHDCI (341174-B21 – 6-feet,
341175-B21 – 12-feet, 164604-B21 – 24-feet)
xx = 02 (6-feet), 03 (12-feet), 04 (24-feet)
     

3X-BC56J-xx

PCI 1-port Ultra2 (LVD) SCSI adapter, 32-bit/33-MHz, single-channel (uses one PCI slot); includes internal 68-pin and external 68-pin HD connectors; order BN38C-xx cable to connect adapter to Ultra3 shelf, or order VHDCI converter (BN38E-0B) for use with included cable; HSZxx RAID controllers not supported. No support for shared SCSI.
Linux-supported option; maximum one per system
6 6 3.3/5 V 33 MHz

3X-KZPCA-AA

68-pin HD male-to-VHDCI male UltraSCSI cable;
xx = 02, 03, 05, 10, 20 meters
BN38C-xx
PCI 1-port UltraSCSI wide differential 32-bit/33-MHz PCI adapter (uses one PCI slot); includes external 68-pin HD connector, requires BN38C-xx cable (2 to 20 meters) to connect adapter to differential UltraSCSI shelf or RAID controller 4 4 3.3/5 V 33 MHz 3X-KZPBA-CC
68-pin HD male-to-VHDCI male UltraSCSI cable;
xx = 02, 03, 05, 10, 20 meters
BN38C-xx
Fibre Channel PCI to 2-Gb Fibre Channel adapter, 64-bit/66-MHz, single-channel (261329-B21)
NOTE: When used in a switched standalone or TruCluster environment (with Fibre Channel Switches – see Step 11), a maximum of six adapters is supported. Arbitrated loop is not supported. Tru64 UNIX V 5.1A requires Patch Kit:
T64V51AB01AS0001-
20020116.tar
See Note See Note 3.3/5 V 66 MHz DS-KGPSA-DA
    See Fibre Channel cables and switches, Step 11                   
                
Multi-function Module PCI 32-bit, 33-MHz multi-function (single-port 10/100 Ethernet UTP/RJ45, Ultra2 LVD SCSI, and 2D graphics) adapter. Model 1 or 1B requires installation on PCI Bus 0 in slots 1 or 2; Model 2 or 2B 1B requires installation on PCI Bus 0 in slots 3, 6, 9, or 10
NOTE: Tru64 UNIX V5.1A requires Patch Kit 3:
T64V51AS0003-20010413.tar. Only one 3X-KZPEA-DB allowed on same PCI bus; no multi-head graphics support; TruCluster support restricted to non-shared SCSI buses only.

Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.

1 1 5V 33
MHz

3X-DEPVZ-AA

  3X-DEPVZ-AA specific-use 3-meter LVD2 SCSI cable         BN37A-03
             
RAID PCI 3-port PCI to Ultra2, 64-bit, LVD backplane RAID controller with 64-MB cache (uses one PCI slot); requires connection to BA610-6D disk card cage or DS-SL13R-xx Universal StorageWorks shelf; requires graphics adapter to run console utilities (SMOR) or alternatively, this can run via a serial line using a PC and terminal emulation software.

NOTE: DS-KZPCC-xx RAID controllers require Tru64 UNIX V5.1A;
TruCluster support with V5.1A requires Initial Patch Kit: T64V51AB01AS0001-
20020116.TAR

8 - 3.3/5 V 33 MHz DS-KZPCC-CE
PCI 1-port PCI to Ultra2, 64-bit, LVD backplane RAID controller with 16-MB cache (uses one PCI slot); requires connection to BA610-6D disk card cage or DS-SL13R-xx Universal StorageWorks shelf; requires graphics adapter to run console utilities (SMOR) or alternatively, this can run via a serial line using a PC and terminal emulation software.
NOTE: DS-KZPCC-xx RAID controllers require Tru64 UNIX V5.1A;
TruCluster support with V5.1A requires Initial Patch Kit: T64V51AB01AS0001-2
0020116.TAR
8 - 3.3/5 V 33 MHz

DS-KZPCC-AC

PCI 2-port PCI to Ultra3, 64-bit, 66 MHz, LVD backplane RAID controller with 128-MB cache (uses one PCI slot); requires connection to DS-SL13R-xx shelves or BA610-6D card cage.
NOTE: Tru64 UNIX requires V5.1B and TruCluster V5.1B (non- shared buses only) with Initial Patch Kit:

T64V51BV1AS0001-
20021229.tar

Tru64 UNIX requires V5.1A with Initial Patch Kit:

T64V51AV21AS0004-
20030206.tar

NOTE: No host-based volume shadowing or shared bus support under OpenVMS.

6 per system,

3 per PCI bus

6 per
system,

3 per PCI
bus

3.3/5 V 66 MHz

3X-KZPDC-BE

PCI 4-port PCI to Ultra3, 64-bit, 66 MHz, LVD backplane RAID controller with 256-MB cache (uses one PCI slot); requires connection to DS-SL13R-xx shelves or BA610-6D card cage.
NOTE: Tru64 UNIX requires V5.1B and TruCluster V5.1B
(non-shared buses only) with Initial Patch Kit:

T64V51BV1AS0001-20021229.tar

Tru64 UNIX requires V5.1A with Initial Patch Kit:

T64V51AV21AS0004-
20030206.tar

NOTE: No host-based volume shadowing or shared bus support under OpenVMS.

6 per system,

3 per PCI bus

6 per
system,

3 per PCI bus

3.3/5 V 66 MHz

3X-KZPDC-DF

PCI to Fibre Channel adapter, 64-bit single-channel (uses one PCI slot); supported only on Linux, maximum of 4 adapters; requires 3X-KZPCA-AA SCSI adapter and must be installed in 66MHz PCI bus slots only; supports HSG80 controller in transparent failover mode only. No support for mulit-path and multi-bus modes. - - 66 MHz

only

DS-SWLA4-PD
                  
CI PCI CI adapter for OpenVMS systems only; requires two 5.0 V PCI slots and CI cable for each adapter
NOTE: DS-HSJ80-xx controllers are supported with CIPCA on ES45 systems.
- 2 5 V 33 MHz CIPCA-BA
  CI cable       BNCIA-xx
    
Step 11 - Storage Devices - Optional
Step 11a - Tape Devices
For detailed tape drive information see http://www.compaq.com/products/storageworks/
sitemap.html#tapedrives

NOTE: This web site is available in English only.
  • System includes embedded 1.44-MB diskette drive
  • System includes embedded 5.25-inch half-height 600-MB 16X ATPI DVD-ROM drive
  • Removable media slots provide support for up to two 5.25-inch half-height devices, or one 5.25-inch full-height removable media device; select up to two AIT or DAT devices or one DLT/SDLT tape device
  • For maximum performance, tape libraries must be configured with Fast Wide Differential (FWD) controllers for tape backup
    
AIT Tape Drives (Internal)
  • The following AIT tape drives are supported with 3X-KZPCA-AA and 3X-KZPEA-DB adapters.
AIT 5.25-inch half-height 35/70-GB 8-mm Wide UltraSCSI tape drive, top gun blue; supports KZPBA-CA, KZPCM-DA adapters and SCSI cable (3X-BN46M-01)

3X-SZ35X-LB

AIT 5.25-inch half-height 35/70-GB 8-mm LVD UltraSCSI tape drive, carbon black

3R-A2392-AA

AIT 5.25-inch half-height 50/100-GB 8-mm Ultra2 (LVD) SCSI tape drive, top gun blue; requires SCSI cable (3X-BN46M-01)

3X-SZ50X-LB

AIT 5.25-inch half-height 50/100-GB 8-mm Ultra2 (LVD) SCSI tape drive, carbon black; requires SCSI cable (3X-BN46M-01) (157766-B22)

3R-A3753-AA

AIT 5.25-inch half-height 100/200-GB 8-mm Ultra3 SCSI tape drive; supports
3X-KZPEA-DB, 3X-KZPCA-AA, or 3X-DEPVZ-AA LVD adapter, carbon black

3R-A3623-AA

1-meter Ultra2 68-pin LVD cable with two connectors, multimode terminator and two wide-to-narrow adapters
(for connection of 50-pin narrow devices)

3X-BN46M-01

   
AIT Tabletop Tape Drives AIT 35/70-GB 8-mm LVD tabletop tape drive, carbon black, North America

216885-001

Same as above, International

216885-B31

Same as above, Japan

216885-291

AIT 50/100-GB 8-mm SCSI tabletop tape drive, carbon black, with 120V North American power cord

157767-002

Same as above, International

157767-B32

Same as above, Japan

157767-292

AIT 100/200-GB 8-mm Ultra3 SCSI tabletop tape drive; supports 3X-KZPEA-DB,
3X-KZPCA-AA, or 3X-DEPVZ-AA LVD adapters, North America, carbon black

249160-001

Same as above, International

249160-B31

   
AIT Hot-plug Tape Drives AIT 35/70-GB hot plug LVD Universal tape drive, uses two slots in BA610-6D or 43xxx shelves

3R-A2396-AA

AIT 50/100-GB hot plug LVD Universal tape drive, uses two slots in BA610-6D or 43xxx shelves

3R-A2779-AA

AIT 100/200-GB hot plug LVD Universal tape drive, uses two slots in BA610-6D or 43xxx shelves; supports 3X-KZPEA-DB, 3X-KZPCA-AA, or 3X-DEPVZ-AA LVD adapters

3R-A3621-AA

   
AIT Autoloaders AIT 35-GB tabletop autoloader, 8 cartridge, U.S.

292355-001

Same as above, International

292355-B31

AIT 35-GB rackmount autoloader, 8 cartridge, U.S.

280349-001

Same as above, International

280349-B31

AIT rail kit for autoloader

284930-001

   
AIT Tape Libraries SSL2020 AIT tabletop library with one AIT 50-GB drive and 20 slots, LVD

175195-B21

SSL2020 AIT tabletop library with two AIT 50-GB drives and 20 slots, LVD

175195-B22

SSL2020 AIT rackmount library with one AIT 50-GB drive and 20 slots, LVD

175196-B21

SSL2020 AIT rackmount library with two AIT 50-GB tape drives and 20 slots, LVD

175196-B22

   
DAT Tape Drives (Internal)
  • Select up to two DAT devices.
  • The following DAT tape drives are supported with 3X-KZPCA-AA and 3X-KZPEA-DB adapters.
DAT 12/24-GB 4-mm 5.25-inch half-height SCSI tape drive, top gun blue; requires SCSI cable (3X-BN46M-01)

TLZ10-LB

DAT 20/40-GB 4-mm 5.25-inch half-height Ultra2 (LVD) SCSI tape drive, top gun blue; requires SCSI cable (3X-BN46M-01)

3X-SD20X-LB

DAT 20/40-GB 4-mm 5.25-inch half-height Ultra2 (LVD) SCSI tape drive, carbon black; requires SCSI cable (3X-BN46M-01) (157769-B22)

3R-A3752-AA

1-meter Ultra2 68-pin LVD cable with two connectors, multimode terminator and two wide-to-narrow adapters (for connection of 50-pin narrow devices)

3X-BN46M-01

DAT 12/24-GB 4-mm narrow single-ended tabletop SCSI tape drive in StorageWorks carrier; Linux supported option; maximum one per system

DS-TLZ10-DB

   
DAT Tabletop Tape Drives DAT 20/40-GB 4-mm Wide Ultra2 (LVD) tabletop SCSI tape drive with 120V North American power cord, carbon black; requires Ultra2 (LVD) adapter

157770-002

Same as above, International

157770-B32

Same as above, Japan

157770-292

   
DAT Hot-plug Tape Drive DAT 20/40-GB DDS4 hot-plug LVD Universal tape drive, uses two slots in BA610-6D or 43xxx shelves; Linux supported option; maximum one per system

3R-A2780-AA

   
DAT Autoloaders DAT 20/40-GB auto loader external; requires VHDCI BN38A-0B adapter and BN23G-xx SCSI cable, North America

166505-001

Same as above, International

166505-B31

Same as above, Japan

166505-291

   
DLT/SDLT Tape Drives (Internal)
  • Select one DLT/SDLT tape device
  • The following DLT/SDLT tape drives are supported with 3X-KZPCA-AA or 3X-KZPEA-DB LVD adapters
DLT8000 40/80-GB tape drive

146196-B22

SDLT 110/220-GB 3U/5U tape drive

192106-B25

SDLT 160/320-GB 3U/5U tape drive, carbon black

257319-B21

   
DLT/SDLT Tabletop Tape Drives SDLT tabletop 110/220-GB external tape drive, carbon black - TruCluster support restricted to non-shared buses only - U.S.

192103-002

Same as above – International

192103-B32

Same as above – Japan

192103-292

   
SDLT tabletop 160/320-GB external tape drive, carbon black, U.S.

257319-001

Same as above, International

257319-B31

Same as above, Japan

257319-291

  
Rackmount kit for H9Axx M-Series cabinets – required for mounting MSL5000 series in M-Series cabinets

254795-001

  
MSL5026DLX, DLT tabletop library with one 40/80-GB DLT tape drive, LVD

231821-B21

MSL5026DLX, DLT tabletop library with two 40/80-GB DLT tape drives, LVD

231821-B22

MSL5026DLX or MSL5026SL, DLT/SDLT rackmount library, 0 drives; requires rackmount kit (254795-001)

231979-B21

MSL5026DLX, DLT rackmount library with one 40/80-GB DLT tape drive, LVD; requires rackmount kit (254795-001)

231891-B21

MSL5026DLX, DLT rackmount library with two 40/80-GB DLT tape drives, LVD; requires rackmount kit (254795-001)

231891-B22

  
MSL5026SL, SDLT tabletop library with one 110/220-GB SDLT tape drive, LVD

302511-B21

MSL5026SL, SDLT tabletop library with two 110/220-GB SDLT tape drives, LVD

302511-B22

MSL5026SL, SDLT rackmount library with one 110/220-GB SDLT tape drive, LVD; requires rackmount kit (254795-001)

302512-B21

MSL5026SL, SDLT rackmount library with two 110/220-GB SDLT tape drives, LVD; requires rackmount kit (254795-001)

302512-B22

  
MSL5026S2, SDLT2 tabletop library with one 160/320-GB SDLT tape drive, LVD

293-473-B21

MSL5026S2, SDLT2 tabletop library with two 160/320-GB SDLT tape drives, LVD

293473-B22

MSL5026S2 SDLT rackmount library, 0 drives, LVD – requires rackmount kit (254795-001)

293472-B21

MSL5026S2, SDLT2 rackmount library with one 160/320-GB SDLT tape drive, LVD

293472-B22

MSL5026S2, SDLT2 rackmount library with two 160/320-GB SDLT tape drive, LVD

293472-B23

MSL5026S2, SDLT2 rackmount library with one 160/320-GB SDLT tape drive with Fibre Channel, LVD

293472-B24

MSL5026S2, SDLT2 rackmount library with two 160/320-GB SDLT tape drive with Fibre Channel, LVD

293472-B25

   
MSL5052SL SDLT tabletop library with two 110/220-GB drives, LVD

249490-B21

MSL5052SL SDLT rackmount library, 0 drives, LVD – requires rackmount kit
(254795-001)

255102-B21

MSL5052SL SDLT rackmount library with two 110/220-GB drives, LVD – requires rackmount kit (254795-001)

249491-B21

MSL5052SL SDLT 110/220-GB drive field upgrade, LVD

231823-B22

   
MSL5052S2, SDLT2 tabletop library with two 160/320-GB SDLT tape drives, LVD, graphite

293476-B21

MSL5052S2, SDLT2 rackmount library with two 160/320-GB SDLT tape drive, LVD

293474-B21

MSL5052S2, SDLT2 rackmount library with two 160/320-GB SDLT tape drive with Fibre Channel, LVD

293474-B24

   
DLT/SDLT Tape Libraries ESL9198SL SDLT tape library with four 110/220-GB SDLT tape drives, 198 slots

234618-B21

ESL9198SL SDLT tape library with eight 110/220-GB SDLT tape drives, 198 slots

234618-B22

   
ESL9322S2 SDLT2 tape library, two 160/320-GB SDLT tape drives, 222 slots

293409-B22

ESL9322S2 SDLT2 tape library, eight 160/320-GB SDLT tape drives, 222 slots

293409-B28

ESL9322S2 SDLT2 tape library, two 160/320-GB SDLT tape drives, 322 slots

293410-B22

ESL9322S2 SDLT2 tape library, eight 160/320-GB SDLT tape drives, 322 slots

293410-B28

   
ESL9326SL SDLT tape library with six 110/220-GB SDLT tape drives, LVD

234615-B21

ESL9326SL SDLT tape library with eight 110/220-GB SDLT tape drives, LVD

234615-B22

ESL9326SL SDLT tape library with 16 110/220-GB SDLT tape drives, LVD

234615-B26

    
ESL9595S2 SDLT2 tape library, two 160/320-GB SDLT tape drives, 400 slots

293411-B22

ESL9595S2 SDLT2 tape library, 16 160/320-GB SDLT tape drives, 400 slots

293411-B28

ESL9595S2 SDLT2 tape library, two 160/320-GB SDLT tape drives, 500 slots

293412-B22

ESL9595S2 SDLT2 tape library, 16 160/320-GB SDLT tape drives, 500 slots

293412-B28

ESL9595S2 SDLT2 tape library, two 160/320-GB SDLT tape drives, 595 slots

293413-B22

ESL9595S2 SDLT2 tape library, 16 160/320-GB SDLT tape drives, 595 slots

293413-B28

   
ESL9595SL SDLT tape library, 0 drives, 400 slots

274672-B21

ESL9595SL SDLT tape library, 2 drives, 400 slots

274672-B22

ESL9595SL SDLT tape library, 16 drives, 400 slots

274672-B28

ESL9595SL SDLT tape library, 0 drives, 500 slots

281627-B21

ESL9595SL SDLT tape library, 2 drives, 500 slots

281627-B22

ESL9595SL SDLT tape library, 16 drives, 500 slots

281627-B28

ESL9595SL SDLT tape library, 0 drives, 595 slots

281628-B21

ESL9595SL SDLT tape library, 2 drives, 595 slots

281628-B22

ESL9595SL SDLT tape library, 16 drives, 595 slots

281628-B28

NOTE: The following options are supported with 3X-KZPCA-AA or 3X-KZPEA-DB LVD adapters.
   
3U Rackmount Tape Drive Enclosure 3U LVD Rackmount Tape Drive Enclosure for use in H9Axx M-Series Cabinets, 0 drives, carbon black

274338-B21

Rackmount Kit for H9Axx M-Series Cabinets, carbon black – required for mounting 3U Rackmount Tape Drive Enclosure in M-Series cabinet

3R-A3804-AA

NOTE: The 3U Rackmount Tape Enclosure supports up to four internal half-height removable devices, or up to two full-height devices; select up to four AIT or DAT devices or two DLT/SDLT devices with 3U Rackmount Tape Enclosure (274338-B21) or select one of the preconfigured configurations listed below.
AIT 35/70-GB 3U tape drive, carbon black

216884-B21

AIT 50/100-GB 3U tape drive, carbon black, (157766-B22)

3R-A3753-AA

DAT 20/40-GB 3U tape drive, carbon black, 157769-B22)

3R-A3752-AA

DLT8000 40/80-GB tape drive

146196-B22

SDLT 110/220-GB tape drive

192106-B25

SDLT 160/320-GB tape drive, carbon black

257319-B21

Preconfigured configurations
AIT 50-GB 3U rackmount kit, carbon black

274333-B21

DLT 40/80-GB, 3U rackmount kit, carbon black

274332-B21

DLT 40/80-GB, dual-drive, 3U rackmount kit, carbon black

274335-B21

SDLT 110/220-GB, 3U rackmount kit, carbon black

274331-B21

SDLT 110/220-GB, dual-drive, 3U rackmount kit, carbon black

274334-B21

   
5U Rackmount Tape Drive Enclosure 5U LVD Rackmount Tape Drive Enclosure for use in H9Axx M-Series Cabinets, 0 drives, carbon black

274339-B21

Rackmount Kit for H9Axx M-Series Cabinets, carbon black - required for mounting 5U Rackmount Tape Drive Enclosure in M-Series Cabinet

254795-001

NOTE: The 5U Rackmount Tape Enclosure supports four full-height removable devices; select up to four DLT or SDLT devices with 5U Rackmount Tape Enclosure (274339-B21) or select one of the preconfigured configurations listed below.
DLT8000 40/80-GB tape drive

146196-B22

SDLT 110/220-GB tape drive

192106-B25

SDLT 160/320-GB tape drive, carbon black

257319-B21

Preconfigured configurations
SDLT 110/220-GB Tape Array III, 5U rackmount kit, carbon black

274336-B21

DLT 40/80-GB Tape Array III, 5U rackmount kit, carbon black

274337-B21

DLT Tape Array III, Model 0 enclosure, U.S.

168047-001

Same as above, International

168047-B31

Same as above, Japan

168047-291

     
Step 11b –Modular Data Routers
Network Storage Routers NOTE: The following Network Storage Routers are supported with MSL5000 and ESL9000 tape libraries:
NSR M2402 Two Fibre Channel x 4 HVD FC to SCSI Data Router, Tru64 UNIX and OpenVMS (262654-B21)

3R-A3741-AA

NSR M2402 Two Fibre Channel x 4 LVD FC to SCSI Data Router, Tru64 UNIX and OpenVMS (262653-B21)

3R-A3740-AA

NSR e1200 One Fibre Channel x 2 LVD FC to SCSI Data Router, Tru64 UNIX and OpenVMS, carbon black (262672-B21)

3R-A3746-AA

NSR e2400 Two Fibre Channel x 4 LVD FC to SCSI Data Router with card cage, Tru64 UNIX and OpenVMS, carbon black (262665-B21)

3R-A3935-AA

NSR e2400 Two Fibre Channel x 4 LVD FC to SCSI Data Router with no card cage, Tru64 UNIX and OpenVMS, carbon black (262664-B21)

3R-A3745-AA

NSR N1200 One Fibre Channel x 2 LVD FC to SCSI Data Router, Tru64 UNIX and OpenVMS, supports tape drives and tape libraries (280823-B21)

3R-A3747-AA

   
Step 11c – External Storage Solutions/Controllers
Enterprise Virtual Array Model 2C6D-B 60-Hz, includes 41U graphite storage cabinet, M3220 controller assembly with dual HSV110 controllers, six M5214 dual-redundant FC loop 14-bay drive enclosures, four 12-port FC loop switches; requires
DS-KGPSA-xx (283198-B21)

DS-SV110-JA

Enterprise Virtual Array Model 2C6D-B 50-Hz, includes 41U graphite storage cabinet, M3220 controller assembly with dual HSV110 controllers, six M5214 dual-redundant FC loop 14-bay drive enclosures, four 12-port FC loop switches; requires
DS-KGPSA-xx (283198-B22)

DS-SV110-JB

Enterprise Virtual Array Model 2C12D-B 60-Hz, includes 41U graphite storage cabinet, M3220 controller assembly with dual HSV110 controllers, 12 M5214 dual-redundant FC loop 14-bay drive enclosures, four 12-port FC loop switches; requires DS-KGPSA-xx, (283199-B21)

DS-SV110-KA

Enterprise Virtual Array Model 2C12D-B 50-Hz, includes 41U graphite storage cabinet, M3220 controller assembly with dual HSV110 controllers, 12 M5214 dual-redundant FC loop 14-bay drive enclosures, four 12-port FC loop switches; requires DS-KGPSA-xx (283199-B22)

DS-SV110-KB

Enterprise Virtual Array Model 8C8D 60-Hz, includes 41U graphite storage cabinet, four M3220 controller assembly with eight HSV110 controllers, eight M5214 dual FC loop
14-bay drive enclosures; requires DS-KGPSA-xx (283263-B21)

DS-SV110-LA

Enterprise Virtual Array Model 8C8D 50-Hz, includes 41U graphite storage cabinet, four M3220 controller assembly, with eight HSV110 controllers, eight M5214 dual FC loop
14-bay drive enclosures; requires DS-KGPSA-xx (283263-B22)

DS-SV110-LB

Enterprise Virtual Array Model 0C6D-B 60-Hz, includes 41U graphite storage cabinet, six M5214 dual-redundant FC loop 14-bay drive enclosures, 12 16.4-feet/5-meter interconnect cables (to 2C12D-B); requires DS-KGPSA-xx (283264-B21)

DS-SV110-MA

Enterprise Virtual Array Model 0C6D-B 50-Hz, includes 41U graphite storage cabinet, six M5214 dual-redundant FC loop 14-bay drive enclosures, 12 16.4-feet/5-meter interconnect cables (to 2C12D-B); requires DS-KGPSA-xx (283264-B22)

DS-SV110-MB

Enterprise Virtual Array Model 0C12D-B 60-Hz, includes 41U graphite storage cabinet, 12 M5214 dual-redundant FC loop 14-bay drive enclosures, 24 16.4-feet/5-meter interconnect cables (to two 2C12D-Bs); requires DS-KGPSA-xx (283265-B21)

DS-SV110-NA

Enterprise Virtual Array Model 0C12D-B 50-Hz, includes 41U graphite storage cabinet, 12 M5214 dual-redundant FC loop 14-bay drive enclosures, 24 16.4-feet/5-meter interconnect cables (to two 2C12D-Bs); requires DS-KGPSA-xx (283265-B22)

DS-SV110-NB

   
SAN Solutions Kits Tru64 UNIX SAN Solutions Kit for Enterprise Virtual Array V2.0 (250193-B22)
NOTE: V5.1 requires Patch Kit 3: T64V51B19AS0005-20020411.tar

V5.1A requires Patch Kit 3: T64V51AB03AS0003-20020827.tar.

QB-6RPAB-SB

OpenVMS SAN Solutions Kit for Enterprise Virtual Array V2.0 (250194-B22)
NOTE: V7.2-2 requires Tima Kit: DEC-AXPVMS-VMS722_FIBRE_SCSI-V0200

V7.3 requires Tima Kit: DEC-AXPVMS-VMS73_FIBRE_scsi-V0300.

QB-6RPAC-SB

   
Fibre Channel Controller Fibre Channel Controller (HSG80), includes 256-MB cache, requires the following firmware:

8.6-4F ACS FW (222318-B22, QB-6BUAA-SD), one per controller
8.6-4S ACS FW (222364-B22, QB-6ENAA-SC), one per controller
8.6-4P ACS FW (222316-B22, QB-6CAAA-SD), one per controller
Requires Tru64 UNIX software: 222320-B23, QB-65RAB-SE, one per controller
Requires OpenVMS software: 222321-B22, QB-65RAC-SD, one per controller

DS-HSG80-BK

Additional 256-MB cache for HSG80 (380674-B21)

DS-HSDIM-AC

Single cache battery, one per HSG80 controller (135823-B21)

DS-SE2CS-CB

Model 2200 controller shelf for HSG80 controller (DS-SE2ZS-C8)

135820-B21

   
StorageWorks Disk Array Family NOTE: The HP StorageWorks Disk Array Family, specifically the XP128 and XP1024, are now supported on AlphaServer ES45 systems. For product and ordering information, refer to the following Web pages:
http://www.hp.com/products1/storage/
products/disk_arrays/
highend/xp1024/index.html

http://www.hp.com/products1/storage/
products/disk_arrays/
highend/xp128/index.html

The following part numbers have been assigned for reference purposes only:

3R-A4417-AA A7876A XP128 Disk Array Control Frame
3R-A4418-AA A7906A XP1024 Disk Array Control Frame
Step 11d – Fibre Channel Options
The following disk drives, hubs, data routers, switches, and cables are used in Fibre Channel configurations using the DS-KGPSA-xx adapter.
   
Fibre Channel Disk Drives 36-GB 10K rpm dual-port 2-Gb/sec FC-AL 1-inch (2.54 cm) drive (238590-B21)

3R-A3239-AA

36-GB 15K rpm dual-port 2-Gb/sec FC-AL 1-inch (2.54 cm) drive (236205-B21)

3R-A3210-AA

72-GB 10K rpm dual-port 2-Gb/sec FC-AL 1-inch (2.54 cm) drive (238921-B21)

3R-A3260-AA

   
Fibre Channel Hubs Fibre Channel 7-port Storage Hub, International (Tru64 UNIX only) (234453-B31)

DS-SWXHB-17

Fibre Channel 7-port Storage Hub, Japan (Tru64 UNIX only) (234453-291)

DS-SWXHB-J7

   
Fibre Channel Data Routers 1 Fibre Channel x 2 HVD data router (163082-B21)

3R-A2673-AA

1 Fibre Channel x 2 LVD data router (163083-B21)

3R-A2774-AA

2 x 4 LVD Fiber Channel to SCSI Network Storage Router (262653-B21)

3R-A3740-AA

2 x 4 HVD Fiber Channel to SCSI Network Storage Router (262654-B21)

3R-A3741-AA

   
Fibre Channel Switches Fibre Channel 2-Gb 8-port SAN switch (258707-B21)

DS-DSGGD-AC

Fibre Channel 2-Gb 16-port SAN switch (283056-B21)

DS-DSGGD-AD

Fibre Channel 2-Gb SAN switch – 16-port; requires Tru64 UNIX V5.1A Patch Kit: T64V51AB01AS0001-20020116.tar (287055-B21)

DS-DSGGD-BA

Fibre Channel 2-Gb 64-port Core Switch (254508-B21)

DS-DSGGE-AB

   
McData 64-port Fibre Channel SAN Director Class Switches SAN Director 64 (1 GB) 32 ports, base model

DS-DMGGD-AA

SAN Edge Switch 2 Gb, 32 ports

DS-DMGGE-BC

SAN Edge Switch 2 Gb, 16-ports

DS-DMGGE-BB

NOTE: Connection for, or between, 1-Gb and/or 2-Gb SAN switches requires different cables. Refer to the Switches, Hubs, and Interconnects QuickSpecs at: http://www.compaq.com/products/quickspecs/
North_America/10490.html
   
Fibre Channel Cables NOTE: The following LC-SC connector cables support connectivity between 1-Gb and 2-Gb devices.
2-meter LC-SC multi-mode Fibre Channel cable (221691-B21)

3R-A2976-AA

5-meter LC-SC multi-mode Fibre Channel cable (221691-B22)

3R-A2977-AA

15-meter LC-SC multi-mode Fibre Channel cable (221691-B23)

3R-A2978-AA

30-meter LC-SC multi-mode Fibre Channel cable (221691-B26)

3R-A3458-AA

50-meter LC-SC multi-mode Fibre Channel cable (221691-B27)

3R-A3459-AA

NOTE: The following LC-LC connector cables support connectivity between 2-Gb and 2-Gb devices.
2-meter LC-LC multi-mode Fibre Channel cable (221692-B21)

3R-A2979-AA

5-meter LC-LC multi-mode Fibre Channel cable (221692-B22)

3R-A2980-AA

15-meter LC-LC multi-mode Fibre Channel cable (221692-B23)

3R-A2981-AA

30-meter LC-LC multi-mode Fibre Channel cable (221692-B26)

3R-A3454-AA

50-meter LC-LC multi-mode Fibre Channel cable (221692-B27)

3R-A3455-AA

   
Step 12 - Graphics Adapters - Optional
  • Select graphics adapter, monitor, and country-specific keyboard for Tru64 UNIX and OpenVMS systems if required
   

Maximum # Supported

   
    Tru64 UNIX OpenVMS

PCI/AGP Slot

 
2D Graphics

 

3Dlabs Oxygen VX1 32-MB PCI 2D graphics accelerator; can operate in all slots; for best performance, use 66-MHz slots.
Linux-supported option; maximum one per system

NOTE: Only VX1 cards may be used in a multi-head environment.

4 4 3.3/5 V 66 MHz SN-PBXGF-AB
3Dlabs Oxygen VX1 32-MB AGP 2D graphics accelerator; AGP can only operate in Model 1B or Model 1 in slot 3; requires Tru64 UNIX V5.1A with NHD-4; requires OpenVMS V7.3-1; no TruCluster support.

NOTE: Only VX1 cards may be used in a multi-head environment.

4

(1 AGP3 PCI)

4

(1 AGP3 PCI)

1.5 V 4X SN-PBXGF-BC
PCI 32-bit, 33-MHz multi-function (single-port 10/100 Ethernet UTP/RJ45, Ultra2 LVD SCSI, and 2D graphics) adapter. Model 1 or 1B requires installation on PCI Bus 0 in slots 1 or 2; Model 2 or 2B 1B requires installation on PCI Bus 0 in slots 3, 6, 9, or 10.

NOTE: Tru64 UNIX V5.1A requires Patch Kit 3:
T64V51AS0003-20010413.tar
Only one 3X-KZPEA-DB allowed on same PCI bus; no multi-head graphics support; TruCluster support restricted to non-shared SCSI buses only.

Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.

1 1 5V 33MHz

3X-DEPVZ-AA

3D Graphics PowerStorm 300 3D multi-head graphics accelerator with 15-MB frame buffer memory and 16-MB texture memory; use in slots 3, 6, 9, or 10.

NOTES: Only PowerStorm cards may be used in a multi-head environment.
3X-KZPEA-DB adapter requires 54-25563-01 be at minimum Rev C06 when installing
3X-KZPEA-DB on same PCI bus.

4 4 5 V 33 MHz SN-PBXGD-AD
  PowerStorm 350 3D multi-head graphics accelerator with 30-MB frame buffer memory and 32-MB texture memory; use in slots 3, 6, 9, or 10.

NOTES: Only PowerStorm cards may be used in a multi-head environment.
3X-KZPEA-DB adapter requires 54-25563-01 be at minimum Rev B05, or 54-25563-02 be at minimum Rev A03, when installing
3X-KZPEA-DB on same PCI bus.

4 4 5 V 33 MHz SN-PBXGD-AE
    
Step 13- Monitors - Optional
  • Graphics monitors other than those listed can be used if compatible with SVGA graphics ordered with system.
  • A video cable, 6-foot/1.8-meter length, is included with all variants of monitors.
  • Video extension cable required if monitor is located more than 1.5-meter from system.
  • Monitors will ship with, but not be integrated with systems.
Carbon/Silver Monitors V7550 17-inch (16-inch viewable image size) flat-faced shadow mask color monitor, two-tone (carbon/silver), 0.25mm dot pitch, VGA to 1024 x 768 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable

3R-A4002-AA

Same as above, with Euro power cord

3R-A4201-AA

Same as above, APD, no power cord

3R-A4202-AA

Same as above, with PRC power cord, CCIB

3R-A4446-AA

Same as above, Southern Hemisphere, with Australia/New Zealand power cord

3R-A4203-AA

    
P930 19-inch (18-inch viewable image size) auto-scanning color monitor, Diamondtron NF, 0.24-mm aperture grille pitch, VGA to 1600 x 1200 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable

3R-A4215-AA

Same as above, with Euro power cord

3R-A4391-AA

Same as above, Taiwan, with NA power cord

3R-A4392-AA

Same as above, with PRC power cord, CCIB

3R-A4394-AA

Same as above, Southern Hemisphere, 0.25 to 0.27 mm aperture grille pitch, with Australia/New Zealand power cord

3R-A4393-AA

    
P1130 21-inch (19.8–inch viewable image size) FD Trinitron auto-scanning color monitor, 0.24-mm aperture grille pitch, VGA to 1792 x 1344 @85Hz, dual video input, USB Hub, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable

3R-A4216-AA

Same as above, with Euro power cord

3R-A4396-AA

Same as above, Taiwan, with NA power cord

3R-A4397-AA

Same as above, with PRC power cord, CCIB

3R-A4400-AA

Same as above, Southern Hemisphere, with Australia/New Zealand power cord

3R-A4398-AA

    
Carbon/Silver Flat Panel Monitors TFT1825, 18-inch (18-inch viewable image size) TFT flat panel monitor, 0.28mm pixel pitch, 1600 x 1200 @60Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, one VGA, one DVI-I input connector, NA power cord, VGA, and DVI-I cables

3R-A4292-AA

TFT1520, 15-inch (15-inch viewable image size) TFT flat panel monitor, 0.297 mm pixel pitch, 1024 x 768 @75 Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, two video input connectors (one VGA and one DVI-I), NA power cord, VGA and DVI-I cables

3R-A4249-AA

   
Video Extension Cable 6-foot/1.8-meter video extension cable

BN39C-02

   
Monitor Power Cords North America

BN26J-1K

Australia, New Zealand, 2.5-meter (103541-011)

BN19H-2E

Central Europe, 2.5-meter

BN19C-2E

Denmark, 2.5-meter (103541-481)

BN19K-2)

Egypt, India, South Africa, 2.5-meter (103541-AR1)

BN19S-2E

Israel, 2.5-meter

BN18L-2E

Italy, 2.5-meter (103541-461)

BN35M-02

Japan, 2.5-meter, Dentori approved

3X-BN46F-02

Republic of China (103541-001)

BN19H-2E

Switzerland, 2.5-meter (103541-511)

BN19E-2E

UK, Ireland, 2.5-meter

BN19A-2E

   
Step 14 - Keyboards, Mouse, and Documentation – Optional
Step 14a - Keyboards
  • Select country-specific keyboard or mouse only if required
  • All keyboards listed may not be available in all geographies
  • Select an opal OpenVMS keyboard for use with VT5xx text terminals
    Opal (for VT5xx) Carbon
Keyboard/Language OpenVMS Tru64 UNIX/Linux OpenVMS
U.S./English keyboard LK461-A2 3R-LKQ48-BA 3X-LK462-A2
Arabic keyboard - 3R-LKQ48-BR -
Belgian keyboard LK461-AB 3R-LKQ48-AB 3X-LK462-AB
BHCSY keyboard - 3R-LKQ48-AX -
Canadian/English keyboard LK461-AQ - 3X-LK462-AQ
Canadian/French keyboard LK461-AC 3R-LKQ48-AC 3X-LK462-AC
Cyrillic keyboard (Russian) LK461-BT 3R-LKQ48-BT 3X-LK462-BT
Czech keyboard LK461-BV 3R-LKQ48-BV 3X-LK462-BV
Danish keyboard LK461-AD 3R-LKQ48-AD 3X-LK462-AD
Dutch keyboard LK461-AH 3R-LKQ48-AH 3X-LK462-AH
Finnish keyboard LK461-AF 3R-LKQ48-AF 3X-LK462-AF
French keyboard LK461-AP 3R-LKQ48-AP 3X-LK462-AP
German keyboard LK461-AG 3R-LKQ48-AG 3X-LK462-AG
Greek keyboard LK461-BH 3R-LKQ48-BH 3X-LK462-BH
Hebrew keyboard LK461-AT 3R-LKQ48-AT 3X-LK462-AT
Hungarian keyboard LK461-BQ 3R-LKQ48-BQ 3X-LK462-BQ
International keyboard - 3R-LKQ48-BA -
Italian keyboard LK461-AI 3R-LKQ48-AI 3X-LK462-AI
Japanese keyboard - 3R-LKQ48-AJ -
Korean keyboard - 3R-LKQ48-BK -
Latin-American keyboard - 3R-LKQ48-AR -
Norwegian keyboard LK461-AN 3R-LKQ48-AN 3X-LK462-AN
Polish keyboard LK461-BP 3R-LKQ48-BP 3X-LK462-BP
Portuguese keyboard LK461-AV 3R-LKQ48-AV 3X-LK462-AV
Romanian keyboard LK461-BL - 3X-LK462-BL
Simplified Chinese keyboard - 3R-LKQ48-CV -
Slovak keyboard LK461-CZ 3R-LKQ48-CZ 3X-LK462-CZ
Spanish keyboard LK461-AS 3R-LKQ48-AS 3X-LK462-AS
Swedish keyboard LK461-AM 3R-LKQ48-AM 3X-LK462-AM
Swiss/French keyboard LK461-AK 3R-LKQ48-AK 3X-LK462-AK
Swiss/German keyboard LK461-AL - 3X-LK462-AL
Traditional Chinese keyboard - 3R-LKQ48-BI -
Thai keyboard - 3R-LKQ48-CB -
Turkish Q keyboard LK461-BU 3R-LKQ48-BU 3X-LK462-BU
Turkish/F keyboard LK461-BW - 3X-LK462-BW
UK keyboard - 3R-LKQ48-AE -
Yugoslavian keyboard LK461-BY - 3X-LK462-BY
  
Step 14b - Mouse
Mouse 3-button mouse – carbon

3R-A3480-AA

  
Keyboard or Mouse Extension Cable 6-foot/1.8-meter keyboard or mouse extension cable – to extend both keyboard and mouse order two cables

3X-BC34A-06

  
Step 14c - Documentation
Documentation Additional ES45 System Information Kit (includes Owners Guide, print and CD)

QA-6NUAB-G8

  
Step 15 - Console Terminal - Optional
  • Any terminal can be used as a console device
  • Third-party console devices require an EIA-232 25-pin DSUB connector
VT510 video terminal; requires keyboard, H8575-x adapter, and BC16E-x cable

VT510-xx

Console cable, female connector (25-pin passive adapter)

H8575-A

Console cable, male connector (adapter with EOS, ESD, 25 POS D-SUB)

H8575-D

   
Step 16 - Software - Media and documentation required for first system on site
  • Software Processor Code = E
Tru64 UNIX
  • AlphaServer ES45 Tru64 UNIX systems include Unlimited User license, Server Extension license, Internet Express, and Secure Web Server
   
When using Tru64 UNIX V5.1A Tru64 UNIX media and online documentation on CD-ROM

QA-6ADAA-H8

Tru64 UNIX full hard copy documentation

QA-6ADAA-GZ

TruCluster Plus Software Package, licenses for TruCluster Server, Logical Storage Manager and AdvFS Utilities

QP-6R9AE-AA

TruCluster Server License

QL-6BRAE-AA

Logical Storage Manager License

QL-2GVAE-AA

AdvFS Utilities License

QL-0EGAE-AA

Advanced Server for Tru64 UNIX, 25 client concurrent use license

QL-5U29M-3D

Advanced Server for Tru64 UNIX, 50 client concurrent use license

QL-5U29M-3E

Advanced Server for Tru64 UNIX, 100 client concurrent use license

QL-5U29M-3F

Advanced Server for Tru64 UNIX, 250 client concurrent use license

QL-5U29M-3G

Advanced Server for Tru64 UNIX, 500 client concurrent use license

QL-5U29M-3H

Layered products media and documentation for Tru64 UNIX on CD-ROM

QA-054AA-H8

DECnet/OSI extended function license for Tru64 UNIX

QL-MTKAE-AA

DECnet/OSI end-system license for Tru64 UNIX

QL-MTJAE-AA

Open3D for Tru64 UNIX on CD-ROM, includes graphics drivers

QA-OAFAA-H8

OpenVMS
  • AlphaServer ES45 OpenVMS systems include Base license with System Manager license and Enterprise Integration Server License Package for OpenVMS Revision V3.1
  • AlphaStation ES45 OpenVMS systems include pre-installed software, Base license, Concurrent Use 1-user license, NAS 150 Client license, MMS RT license and Open3D traditional license
  • Enterprise Integration Package includes licenses for TCP/IP Services for OpenVMS, DECwindows Motif for OpenVMS Alpha, DECprint Supervisor for OpenVMS Alpha Plus, DECprint Supervisor for OpenVMS Open, DECnet-Plus for OpenVMS Alpha End System, Archive/Backup System for OpenVMS Management Tools, Archive/Backup Agent for Windows NT, OpenVMS Disk Services for Windows NT, Office Server for OpenVMS, PATHWORKS 32, PATHWORKS V6 for OpenVMS – Advanced Server, and DIGITAL Office Server Client Access License
  • OpenVMS Concurrent Use licenses provide the right to interactively use the operating system by the specified number of concurrent users on a designated OpenVMS system. OpenVMS Concurrent Use licenses can be moved from one system to another at user discretion and can be shared in a mixed OpenVMS VAX and OpenVMS Alpha cluster.
  • OpenVMS Traditional Unlimited Use license is system specific and can only be used on one system at a time. It cannot be shared between systems or in an OpenVMS VAX or OpenVMS Alpha Cluster.
Concurrent Use 1-user license

QL-MT3AA-3B

Concurrent Use 2-user license

QL-MT3AA-3C

Concurrent Use 4-user license

QL-MT3AA-3D

Concurrent Use 8-user license

QL-MT3AA-3E

Concurrent Use 16-user license

QL-MT3AA-3F

Concurrent Use 32-user license

QL-MT3AA-3G

Concurrent Use 64-user license

QL-MT3AA-3H

Concurrent Use 128-user license

QL-MT3AA-3J

Concurrent Use 256-user license

QL-MT3AA-3K

Traditional unlimited user license

QL-MT2AE-AA

OpenVMS media and documentation on CD-ROM

QA-MT1AA-H8

OpenVMS full hard copy documentation

QA-001AA-GZ

Layered products media and documentation for OpenVMS on CD-ROM, includes Enterprise Integration Server for OpenVMS media and documentation.

QA-03XAA-H8

DECnet extended function license for OpenVMS

QL-MTGAE-AA

DECnet end-system to extended function upgrade license for OpenVMS

QL-MTHAE-AA

OpenVMS Cluster license for Alpha systems

QL-MUZAE-AA

OpenVMS Volume Shadowing license

QL-2A1AE-AA

   
Step 17 - Hardware and Software Supplemental Support Services for Tru64 UNIX and OpenVMS - Optional
  • Select one of the optional CarePaq Priority Service Packages described below that best supports the customer’s operational requirements for system availability.
    
CarePaq Priority Services
  • CarePaq Priority Services are available for AlphaServer systems running Tru64 UNIX or OpenVMS operating system. Priority Services are designed for the growing number of customers who need support beyond the basic warranty. It offers six service packages – Warranty Plus, Priority, Priority 24, Priority Silver, Priority Gold, and Priority Executive with coverage for both Principal servers systems and SSPs (Subsequent System Packages) - that meet a full range of customer support requirements.
    
Program Features – Principal Server
Warranty Plus
  • 9 x 5 HW/SW support
  • Next Business Day on-site hardware support
  • 2-hour response for Bronze software support
  • License Subscription for HP O/S software and embedded L/P (unlimited users and server extensions for Tru64 UNIX)
    
Priority
  • 9 x 5 HW/SW support
  • 4-hour response on-site hardware support
  • 2-hour response for Bronze software support
  • License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
  • Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their layered products. (Some layered products on Consolidated Media Update Distribution can be ordered separately.)
    
Priority 24
  • 24 x 7 HW/SW support
  • Named HW engineer
  • 4-hour response on-site hardware support
  • 2-hour response for Bronze software support
  • License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users and server extensions for Tru64 UNIX)
  • Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their layered products. (Some layered products on Consolidated Media Update Distribution can be ordered separately.)
    
Priority Silver
  • 24 x 7 HW Support. Named Engineer, 4-hour response
  • 24 x 7 Silver SW Support - Named Account Rep, 1-hour response Monday – Friday, 8AM-5PM local time; 2-hour response remaining hours
  • License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
  • Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their layered products. (Some layered products on Consolidated Media Update Distribution can be ordered separately.)
  • Technical newsletter and SW activity review
  • Proactive Patch Notification
  • One System Healthcheck per year
   
Priority Gold
  • 24 x 7 HW support with Named Engineer, 4-hour response for on-site support
  • 24 x 7 Gold SW support - Named Account Rep
  • 30-minute callback (critical); 1-hour callback (non-critical)
  • License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
  • Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their layered products. (Some layered products on Consolidated Media Update Distribution can be ordered separately.)
  • Technical newsletter, SW activity review and 10 hrs Upgrade impact planning
  • Proactive Revision Management
  • Two System Healthchecks per year
  • Mandatory pre-qualification required
   
Priority Gold Executive
  • 24 x 7 HW support with Named Engineer, 2-hour response for on-site support
  • 24 x 7 Gold SW support - Named Account Rep
  • 30-minute callback (critical); 1-hour callback (non-critical)
  • License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
  • Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their layered products. (Some layered products on Consolidated Media Update Distribution can be ordered separately.)
  • Technical newsletter, SW activity review and 10 hrs Upgrade impact planning
  • Proactive Revision Management
  • Two System Healthchecks per year
  • Customer site must be within 25 miles of a HP service location
  • Mandatory pre-qualification required
   
Program Features – Additional Services
SSPs
(Subsequent System Packages)
  • For Priority, Priority 24, Priority Silver, Priority Gold, and Priority Gold Executive
  • HW Support at same level as corresponding package for Principal server
  • License Subscription: HP O/S (where applicable)
  • Telephone support through Principal server covered by full support package
    
Installation
  • Preinstallation review
  • Unpacking of equipment
  • Assemble and test
  • Basic product usage info
  • No software installation added
    
Installation & Startup HP O/S
  • Preinstallation review
  • Unpacking of equipment
  • Assemble and test
  • Basic product usage info
  • Install operating systems
  • Product configuration
  • Print & network access
  • Orientation
   
Model/CarePaq
Priority Service
Principal Server
1 year
Principal Server
3 years
Subsequent Systems
1 year
Subsequent Systems
3 years
AlphaServer ES45 Model 2        
Warranty Plus Not available FP-F00EB-36 Not available Not available
Priority FP-F01EB-12 FP-F01EB-36 FP-F21EB-12 FP-F21EB-36
Priority 24 FP-F02EB-12 FP-F02EB-36 FP-F22EB-12 FP-F22EB-36
Priority Silver FP-F04EB-12 FP-F04EB-36 FP-F24EB-12 FP-F24EB-36
Priority Gold FP-F08EB-12 FP-F08EB-36 FP-F28EB-12 FP-F28EB-36
Priority Gold Executive FP-F09EB-12 FP-F09EB-36 FP-F29EB-12 FP-F29EB-36
Installation FP-FINST-EB FP-FINST-EB FP-FINST-EB FP-FINST-EB
Installation & Startup FP-FSTAR-EB FP-FSTAR-EB FP-FSTAR-EB FP-FSTAR-EB
    
NOTES:
  • AlphaServer ES45 systems include one-year parts and labor warranty with 5x9, on-site Next Business Day response.
  • Priority Services include support for new HP branded hardware options internal to the AlphaServer enclosure plus a monitor (17-inch or less excluding flat panel models).
  • External storage devices/cabinets carry their own level of warranty and should be quoted separately for uplifted warranty services.
  • Five-year CarePaq Priority Service is available upon request. To quote five-year service, change the last two part number digits from 12 or 36 to 60.
  • In addition to the CarePaq Priority Services, uplifted warranty Supplemental Services are available for separate hardware and software support. For more information on Hardware and Software Supplemental Services and other HP service options available for AlphaServers, please consult your Sales Account Manager or visit: http://www.hp.com/hps/

NOTE: This website is available in English only.

    
Step 18 - Hardware Supplemental Support Services for Linux - Optional
Hardware - Americas and Asia Pacific Only
  • Systems include three-year hardware warranty, onsite with 5 x 9, 24-hour response time
  • Options ordered as part of initial system sale take on warranty of the enclosure
  • Options added after initial system sale take on warranty of the enclosure until enclosure warranty ends
  • All unique ES45 options have a minimum of one-year Return to Hewlett-Packard Warranty
  • Select optional Hardware Supplemental Support Services if required
Supplemental Service for ES45 Tower System Model 1 Model 2
3-year, 5 x 9, 4-hour response time FM-4T4HR-36 FM-4Q4HR-36
5-year, 5 x 9, 4-hour response time FM-4T4HR-60 FM-4Q4HR-60
3-year, 7 x 24, 4-hour response time FM-4T724-36 FM-4Q724-36
5-year, 7 x 24, 4-hour response time FM-4T724-60 FM-4Q724-60
5-year, 5 x 9, next day, on-site FM-4TXHW-60 FM-4QXHW-60
Supplemental Service for ES45 Pedestal System Model 1 Model 2
3-year, 5 x 9, 4-hour response time FM-4F4HR-36 FM-4G4HR-36
5-year, 5 x 9, 4-hour response time FM-4F4HR-60 FM-4G4HR-60
3-year, 7 x 24, 4-hour response time FM-4F724-36 FM-4G724-36
5-year, 7 x 24, 4-hour response time FM-4F724-60 FM-4G724-60
5-year, 5 X 9, next day, on-site FM-4FXHW-60 FM-4GXHW-60
Installation Services Model 1 Model 2
Hardware product installation for ES45 Tower System FM-4TINS-IN FM-4QINS-IN
Hardware product installation for ES45 Pedestal System FM-4FINS-IN FM-4GINS-IN
   
Add-on memory installation for ES45 FM-64MEM-IN
Add-on SMP CPU installation for ES45 FM-64CPU-IN
NOTE: Add-on installation part numbers should be used when options are added to existing systems.
   
Hardware—Europe Only Europe does not offer specific part numbers for Hardware Supplemental Support Services. Prices are quoted based on worldwide service reference pricing. Contact MCS Sales in your country for information on Hardware Supplemental Support Services.
contents
 Overview   Standard Features   Systems/Options   Options   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) TechSpecs
Tower Configuration Dimensions
(H x W x D)
20 x 15.25 x 31.7 in/50.8 x 38.7 x 80.5 cm
Shipping Dimensions 32.2 x 24 x 40 in/82.48 x 60.2 x 101.6 cm
Weight Typical Configuration 144.3 lb/65.6 kg
Maximum Configuration 212.8 lb/96.7 kg
Shipping Weight Typical Configuration 172 lb/78 kg
Maximum Configuration 242 lb/110 kg
Clearances Operating Service
Front 29.5 in/75 cm 29.5 in/75 cm
Rear 6 in/15 cm 29.5 in/75 cm
Left Side None 29.5 in/75 cm
Right Side None None
   
Pedestal Configuration Dimensions
(H x W x D)
30.8 x 20 x 32.4 in/78.2 x 50.8 x 82.3 cm
Shipping Dimensions 42.4 x 39.5 x 23.9 in/107.7 x 100.3 x 60.7 cm
Weight Typical Configuration 280 lb/127 kg
Maximum Configuration 350 lb/159 kg
Shipping Weight Typical Configuration 328 lb/149 kg
Maximum Configuration 407 lb/185 kg
Clearances Operating Service
Front 29.5 in/75 cm 29.5 in/75 cm
Rear 6 in/15 cm 29.5 in/75 cm
Left Side None None
Right Side None 29.5 in/75 cm
   
Rackmount System Dimensions
(H x W x D)
13.87 x 17.6 x 30.8 in/35.2 x 44.7 x 78.2 cm
(fits 14 in [8U] standard RETMA cabinet)
Shipping Dimensions 28.8 x 24 x 40 in/73.2 x 60.7 x 101.6 cm
Weight When lifting: Typical Configuration 110 lb/50 kg
Maximum 167.2 lb/76 kg
Total added to cabinet (brackets, slides, cables): Typical Configuration 130 lb/59 kg
Maximum 202.4 lb/92 kg
Shipping Weight Typical Configuration 158 lb/72 kg
Maximum 233 lb/106 kg
Clearances Operating Service
See specific cabinet requirements Minimum 4 ft/121.9 cm,
32.4 in/82.2 cm withdrawal on rails
     
Cabinet Configuration H9A10 M-Series H9A15 M-Series
Dimensions
(H x W x D)
(Depth includes rear door extender)
67x 23.6 x 41.5 in/
170 x 60 x 105.4 cm
79 x 23.6 x 41.5 in/
200 x 60 x 105.4 cm
Shipping Dimensions 73 x 36 x 48 in/
185.5 x 91.5 x 122 cm
85 x 36 x 48 in/
216 x 91.5 x 122 cm
Weight Configuration dependent Configuration dependent
Shipping Weight Nominal: 946 lb/430 kg
Maximum: 1,375 lb/625 kg
Nominal: 1,056 lb/550 kg
Maximum: 1,408 lb/640 kg
   
System Unit Environmental
Temperature Operating
(Tower, Pedestal, Rackmount)
50?/font> to 95?/font> F/10?/font> to 35?/font> C
Non-operating -40?/font> to 151?/font> F/–40?/font> to 66?/font> C
Storage (60 days) -40?/font> to 151?/font> F/–40?/font> to 66?/font> C
Rate of change 20?/font> F/hr/11?/font> C/hr
NOTE: Maximum operating temperature at sea level; reduce by 1.8?/font> F (1?/font> C) for each 2,000 ft (600 m) above sea level.
Humidity Operating 20% to 80%
Non-operating 20% to 80%
Storage (60 days) 10% to 95%
Rate of change 20% hr
Maximum Wet Bulb Temperature Operating 82?/font> F/28?/font> C
Storage (60 days) 115?/font> F/46?/font> C
Maximum Dew Point Temperature Operating 36?/font> F/2?/font> C
Heat Dissipation Nominal Maximum
Tower and Rack 980W, 3347 BTU/hr 1440W, 4918 BTU/hr
Pedestal 1560W, 5328 BTU/hr 2400W, 8196 BTU/hr
H9A10/H9A15 Cabinets Configuration dependent 4800W, 16392 BTU/hr
Air Flow and Quality Intake location Front
Exhaust location Rear Tower, Pedestal, Rack; Rear/top H9A10/H9A15
Particle size N/A
Concentration N/A
Altitude
(unpressurized)
Operating 10,000 ft/3,048 m
Non-operating 40,000 ft/12,192 m
NOTE: Maximum operating temperature at sea level; reduce by 1.8?/font> F (1?/font> C) for each 2,000 ft (600 m) above sea level.
   
Acoustics (Declared values per ISO 9296 and ISO 7779)
Acoustics LWad, B LnAm, dBA
(bystander position)
Tower or Rackmount Idle 6.4 47
Operating 6.4 47
Pedestal Idle 6.6 48
Operating 6.6 48
NOTE: Current values for specific configurations are available, 1 B = 10 dBA.
Vibration Operating 10 to 500 Hz 0.1 G peak
Non-operating 1.03 Grms 5-300 Hz
   
Electrical (Power supplies are universal, PFC, auto ranging, 200–240 VAC)
Nominal Voltage (VAC) 200 to 240
Voltage Range (VAC) temporary condition 180 to 250
Power Source Phase Single
Nominal Frequency (Hz) 50/60
Frequency Range (Hz) 47 to 53/57 to 63
RMS Current Tower and Rackmount Single power cord 5.6A
Multiple power cords 3.6A
Maximum VA 1440
Pedestal Each power cord 8.6A
Maximum VA 2070
M-Series Cabinet
(configuration dependent)
Nominal voltage (VAC) 200 to 240
Each power cord 16A
Power Cords Tower (mandatory) Up to 3
(Country specific)
IEC 320 to
country-specific
Pedestal (mandatory) 2
(Country specific)
IEC 320 C13 to
country-specific
Rackmount (included) 3
(14 ft 10 in/52 cm)
IEC 320 C13 to IEC 320 C14
Cabinet (included) Up to 4
(10 ft /305 cm)
200-240 V
non-removable NEMA
L6-20P for North America or 200-240 V non-removable IEC 309
    
Regulatory Agency Approvals UL: Listed to UL1950 3rd edition
UL CNL: Certified to CAN/CSA-C22.2
No. 950-1995
TUV: EN 60950/A11:1997, GS marked
FCC: Part 15.B Class A
IC ICES-003 Class A
CE: EN55022:1998, EN55024:1998,
EN61000-3-2:1995, EN61000-3-3:1995
VCCI:V-3/97.04 Class A
BSMI: CNS13438 Class A
C-Tick: AS/NZS 3548:1995 Class A
Reviewed to AS/NZ 3260:1993 Australian/New Zealand Standard
EN 60950:2000
IEC 60950:1999, 3rd edition
UL 60950, 3rd edition, 2000

?2003 Hewlett-Packard Company

Hewlett-Packard, the Hewlett-Packard logo, AlphaServer, OpenVMS, StorageWorks, CarePaq, Tru64, and TruCluster are trademarks of Hewlett-Packard Company in the U.S. and/or other countries. UNIX is a registered trademark or trademark of The Open Group in the U.S. and/or other countries. All other product names mentioned herein may be trademarks of their respective companies.

Hewlett-Packard shall not be liable for technical or editorial errors or omissions contained herein. The information is provided ?/font> as is?/font> without warranty of any kind and is subject to change without notice. The warranties for Hewlett-Packard products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty.


   DA-10994 - U.S. - Version 32 - March 18, 2008