Options
| Step
2 - Additional CPU Modules - Optional |
- One CPU included, three additional CPUs are supported
|
|
SMP upgrade, includes one
68/1000-MHz CPU with 8-MB cache and Tru64 UNIX SMP license |
KN610-DB |
|
SMP upgrade, includes one
68/1000-MHz CPU with 8-MB cache and OpenVMS SMP license |
KN610-DC |
|
SMP upgrade, includes one
68/1250-MHz CPU with 16-MB cache and Tru64 UNIX SMP license |
KN610-EB |
|
SMP upgrade, includes one
68/1250-MHz CPU with 16-MB cache and OpenVMS SMP license |
KN610-EC |
|
NOTE:
Minimum firmware for 1.25-GHz systems is V6.2-8, minimum SROM firmware is V2.22-F.
Firmware files are available at: http://ftp.digital.com/pub/Digital/Alpha/
firmware/interim/es45/v6.2C/ |
|
NOTE:
Existing AlphaServer ES45 1-GHz Model 2 (xx-68DAA-xx) customers who upgrade to 1.25-GHz
CPUs, should continue to follow Model 2 configuration guidelines. The following options
are required: H7906-A9 power supply and MS620-AA, MS620-BA, and MS620-CA memory options.
Do not order 3X-H7514-AA power supplies or MS5620-DB memory options. |
| |
| Step
3 - Memory - Optional |
- Base systems do not include memory; select a minimum of 1-GB
memory; this is a mandatory selection. All other systems include one memory option.
|
- Maximum four memory options (total of 16 DIMMs) for Model 1B or Model 1 (one per array)
|
- Maximum eight memory options (total of 32 DIMMs) for Models 2B or Model 2, and Model 3B
or Model 3 (two per array)
|
- AlphaServer ES45 system includes two memory buses
|
- AlphaServer ES45 system includes two arrays per bus
|
- For Model 2B or Model 2 and Model 3B or Model 3, memory options within an array must be
identical
|
|
512-MB memory option (4 x 128-MB
DIMMs) |
MS620-AA |
|
1-GB memory option (4 x 256-MB
DIMMs) |
MS620-BA |
|
2-GB memory option (4 x 512-MB
DIMMs) |
MS620-CA |
|
4-GB memory option (4 x 1024-MB
DIMMs) NOTE: Do not order
MS620-DB memory option for installation in ES45 1-GHz Model 2
(xx-68DAA-xx) system. MS620-DB memory option can only be installed in
(xx-6xDBA-xx) and (xx-6xEBA-xx) systems. |
MS620-DB |
Memory performance
considerations:
- The AlphaServer ES45 system has two memory buses. When two or more memory options are
installed, both buses are utilized, enhancing system performance
- The AlphaServer ES45 system has two arrays per bus. Interleaved operations reduce the
average latency and increase the memory throughput. When all four arrays are populated
with the same amount of memory, read-write operations are four-way interleaved, enhancing
system performance.
The following examples illustrate different ways of configuring a 4-GB system. Case C
yields the best performance and is the recommended method for configuring memory on an
AlphaServer ES45 system. |
ES45 System
(one memory option included) |
Add-on Memory Options |
Total Memory |
Total DIMMs |
Performance |
| Case A -
DA-68DBA-DA (MS620-DB) |
None |
4-GB |
4 |
Good |
| Case B - DA-68DBA-CA
(MS620-CA) |
MS620-CA |
4-GB |
8 |
Better |
| Case C - DA-68DBA-BA
(MS620-BA) |
MS620-BA +
MS620-BA + MS620-BA |
4-GB |
16 |
Best * |
| |
| NOTE: * =
Operating system and application dependent. Up to an 18% performance enhancement has been
measured in Case C over Case A. |
| |
| Step
4 - Additional Power Supply - Optional |
|
One Power Supply |
Standard with Model 1B or 1, 2B
or 2, and 3B or 3 systems; provides system support for:
- Two CPUs
- One disk drive cage (up to six disk drives)
- Four memory options (up to 16 DIMMs)
|
|
Two Power Supplies |
Optional Provides system
support for:
- Four CPUs
- Two disk drive cages (up to 12 disk drives)
- Eight memory Options (up to 32 DIMMs)
|
|
Third Power Supply |
Optional -
Provides (N+1) power redundancy system support for two power supply configuration |
| |
- Additional power supply ordered with a tower system requires an additional
country-specific power cord
|
- Pedestal system and Rack kit include three internal IEC/IEC power cords regardless of
the number of power supplies ordered
|
|
ES45 1080 W power
supply; order for Models 1B, 2B, and 3B
(1-GHz) and Models 1, 2, and 3 (1.25-GHz) systems only; do not order for Model 2
(xx-68DAA-xx) systems. |
3X-H7514-AA |
|
ES45 720 W power
supply; order for Model 2
(1-GHz xx-68DAA-xx) systems only |
H7906-A9 |
| |
|
|
| Step
5 - Disk Drive Cage, Universal Drive Shelf, or Universal Disk Drive - Mandatory |
- Each system supports up to two disk drive cages
|
- Each disk drive cage supports six 1-inch universal disk drives
|
- 43xx StorageWorks shelves support up to 14 universal disk drives
|
- Pedestal enclosure supports one system and two disk drive cages, two Universal 43xx
StorageWorks shelves
|
- M-Series cabinets supports up to five systems or one system with up to ten StorageWorks
shelves
|
| |
| Step 5a - Disk Drive Cage - Requires selection
of system disk drive |
|
Disk drive cage with storage
cable accommodates up to six internal 1-inch Universal disk drives Requires
mandatory selection of a Storage Adapter in the system. Requires an internal Ultra2 SCSI
or Ultra3 SCSI channel per disk drive cage. Maximum of two storage cages in system. |
BA610-6D |
|
NOTE: See
ES45 Configuration Chart for Storage Adapters in Step 10. |
|
| |
|
|
Universal Disk
Drives
(Supported in Disk Drive Cage and Universal StorageWorks Shelves) |
18.2-GB Ultra320 SCSI 15,000 rpm
1-inch Universal disk drive |
3R-A3848-AA |
| 36.4-GB Ultra320 SCSI 10,000 rpm
1-inch Universal disk drive |
3R-A3838-AA |
| 36.4-GB Ultra320 SCSI 15,000 rpm
1-inch Universal disk drive |
3R-A3849-AA |
|
72.8-GB Ultra320 SCSI 10,000 rpm
1-inch Universal disk drive |
3R-A3839-AA |
|
72.8-GB Ultra320 SCSI 15,000 rpm
1-inch Universal disk drive |
3R-A3851-AA |
|
146-GB Ultra320 SCSI 10,000 rpm
1-inch Universal disk drive |
3R-A3841-AA |
| |
| Step 5b - StorageWorks Model 4314R and Model 4354R Universal Drive Shelves |
- Up to two shelves in Pedestal form factor
|
- See Step 7 for rack configurations with M-Series cabinets
|
- StorageWorks Model 4314R, 4314T and 4354R Ultra3 SCSI (LVD) single-bus and split-bus
Universal drive shelves; refer to StorageWorks Enclosure 4300 Family QuickSpecs when
configuring shelves. When selecting a DS-SL13R-xx split-bus shelf, two SCSI channels are
required from selected storage adapters. BN38C-05 cable is required per channel if the
connection is not VHDCI/VHDCI. DS-SL13R shelves include one 12-foot VHDCI/VHDCI SCSI
cable.
|
|
|
StorageWorks Model 4314R Ultra3
SCSI (LVD) single-bus Universal drive rackmount shelf, includes one power supply, U.S. - no support for Model 4314R single-bus shelves with 3X-KZPEA-DB
adapter (190209-001) |
DS-SL13R-AA |
|
StorageWorks Model 4314R Ultra3
SCSI (LVD) single-bus Universal drive rackmount shelf, includes one power supply, Japan - no support for Model 4314R single-bus shelves with 3X-KZPEA-DB
adapter (190209-291) |
DS-SL13R-AJ |
|
StorageWorks Model
4354R Ultra3 SCSI (LVD) split-bus Universal drive rackmount shelf, includes two redundant
power supplies, U.S. (190211-001) |
DS-SL13R-BA |
|
StorageWorks Model 4354R Ultra3
SCSI (LVD) split-bus Universal drive rackmount shelf, includes two redundant power
supplies, Japan (190211-291) |
DS-SL13R-BJ |
|
To add additional power supply
for single-bus Universal shelf, U.S. (212980-B21) |
DS-SE2UP-AA |
|
To add additional power supply
for single-bus Universal shelf, International
(119826-B31) |
DS-SE2UP-AI |
| |
|
|
| StorageWorks Model
4314T Standalone Enclosures |
Model 4314T Ultra3 SCSI,
Single-bus Tower Enclosure, U.S. (190210-001) |
DS-SL13T-AA |
| Model 4314T Ultra3 SCSI,
Single-bus Tower Enclosure, International (190210-B31) |
DS-SL13T-AB |
|
Model 4314T Ultra3 SCSI,
Single-bus Tower Enclosure, Japan (190210-291) |
DS-SL13T-AJ |
| |
| Step
6 - System Enclosures - Mandatory selection of Tower, Pedestal, Rack Kit, Power Cords |
- All AlphaServer ES45 enclosures are carbon black
- Power cords are mandatory for tower and pedestal enclosures
- Power cords are included in Rack Kits
|
| |
| Step 6a - Tower Enclosure |
- Tower enclosure supports one system
|
Selection of one country-specific power cord is mandatory
|
- Additional power cord is mandatory if additional power supply is ordered.
|
|
200240V Tower Enclosure |
BA61M-CT |
| |
| Step 6b - Pedestal Enclosure |
- Pedestal enclosure supports one system, and up to two Universal 43xx StorageWorks
shelves.
|
- Selection of two country-specific power cords is mandatory for all systems.
|
|
200240V Pedestal Enclosure |
BA61P-CB |
| |
| Step 6c - Rack Kit for M-Series Cabinet |
- Rack Kit required for each AlphaServer ES45 system installed in an M-Series Cabinet
|
- Rack Kit supports one system
|
|
Rack kit for
AlphaServer ES45, includes dress bezel, slides, three internal IEC/IEC power cords, all
brackets and hardware for mounting in M-Series cabinets, 200-240V |
BA61R-CR |
| |
| Step 6d - Power Cords |
|
North American 200 to 240V,
75-inch - Tower |
BN18J-1K |
|
North American 200 to 240V,
108-inch - Pedestal |
3X-BN64A-1C |
|
Australia, New Zealand, 2.5-meter
(103541-011) |
BN19H-2E |
|
Central Europe, 2.5-meter |
BN19C-2E |
|
Denmark, 2.5-meter (103541-481) |
BN19K-2E |
|
Egypt, India, South Africa,
2.5-meter (103541-AR1) |
BN19S-2E |
|
Israel, 2.5-meter |
BN18L-2E |
|
Italy, 2.5-meter (103541-461) |
BN35M-02
|
|
Japan, 2.5-meter, Dentori
approved |
3X-BN46F-02 |
|
Switzerland, 2.5-meter
(103541-511) |
BN19E-2E
|
|
UK, Ireland, 2.5-meter |
BN19A-2E |
|
Republic of China (103541-001) |
BN19H-2E |
| |
| Step
7 - M-Series Cabinets |
- M-Series Cabinet enclosures support up to five systems, or one system with up to ten
StorageWorks shelves.
- M-Series Cabinets require mandatory selection of the following items:
|
- Rear cabinet extender based on cabinet height
|
- Cabinet front door or trim kit based on cabinet height
|
- Second power distribution unit (PDU) M-Series Cabinets include one H7602 PDU
|
|
|
- Ballast kit, if only one system is ordered for the H9A15 cabinet
|
| NOTE: For
additional configurations beyond those listed in the following charts, contact
CustomSystems. |
| |
| Cabinet Configuration Chart
for AlphaServer ES45 (8U) with 43xx Series StorageWorks Shelves (3U) Supports
high-density configurations |
| Cabinet (b) |
Front Door
or Trim Kit |
Cabinet Depth
Extender |
Power Distribution
Unit |
ES45
Systems |
43xx Storage Shelves |
Unused U Spaces |
| H9A10-ME/-MF |
H9C10-ZF
or
H9C10-ZT |
H9C10-ZE |
With second
H7600 |
1 |
8 |
1 |
| (34U) |
|
|
2 |
5 |
2 |
|
|
|
3 |
3 |
0 |
|
|
|
|
4 |
0 |
1 |
| H9A15-ME/-MF |
H9C15-ZF
or
H9C15-ZT |
H9C15-ZE |
With second
H7600 |
1 (a) |
10 |
2 |
| (41U) |
|
|
2 |
8 |
0 |
|
|
|
3 |
3 |
7 |
|
|
|
|
4 |
0 |
8 |
|
|
|
(b) |
3 |
3 or 5 |
1 |
|
|
|
With
second H7602 |
4 |
0 or 2 |
2 |
|
|
|
5 |
0 |
0 |
| NOTES: |
- Installation of only one AlphaServer ES45 system in an H9A15 cabinet requires the
mandatory selection of a ballast kit.
- H9A1x-ME includes one H7602-EB PDU; H9A1x-MF includes one H7602-DB PDU Order
second PDU.
- Single Input - H7600-DB/EB, 240V
- Dual Input - H7602-DB/EB, 240V
|
| |
| M-Series Cabinets - Specify cabinet selection |
67-inch carbon black cabinet with
59.5-inch or 34U of usable vertical space, 200-240V dual-16A PDU, 16 IEC C13
outlets, two input power plug NEMA L620P, Americas, Asia Pacific; includes rear door. |
H9A10-ME |
|
67-inch carbon black cabinet with
59.5-inch or 34U of usable vertical space, 240V dual-16A PDU, 16 IEC C13 outlets, two
input power plug IEC 309, 20A, Europe; includes rear door. |
H9A10-MF |
|
79-inch carbon black cabinet with
71.7-inch or 41U of usable vertical space, 200-240V dual-16A PDU, 16 IEC C13 outlets, two
input power plug NEMA L620P, Americas, Asia Pacific; includes rear door. |
H9A15-ME |
|
79-inch carbon black cabinet with
71.7-inch or 41U of usable vertical space, 240V dual-16A PDU, 16 IEC C13 outlets, two
input power plug IEC 309, 20A, Europe; includes rear door. |
H9A15-MF |
| |
|
|
| Rear Cabinet
Extender - Mandatory based on cabinet height |
Rear cabinet extender for carbon
black H9A10 cabinets |
H9C10-ZE |
| Rear cabinet extender for carbon
black H9A15 cabinets |
H9C15-ZE |
| |
|
|
| Front Cabinet
Treatment - Mandatory based on cabinet height |
Front door for carbon black H9A10
cabinet enclosure |
H9C10-ZF |
| Front trim kit for carbon black
H9A10 cabinet enclosure |
H9C10-ZT |
| Front door for carbon black H9A15
cabinet enclosure |
H9C15-ZF |
|
Front trim kit for carbon black
H9A15 cabinet enclosure |
H9C15-ZT |
| |
|
|
| Factory Integration - Mandatory |
Factory Integration of systems
and storage devices assembled and configured in cabinet enclosure in predefined locations |
YS-ASCAA-AA |
| |
|
|
| Ballast Kit - Mandatory if only one ES45 system drawer is ordered for the
H9A15 cabinet |
- Ballast is added to a cabinet at particular locations for specific configurations to
meet safety regulations for installation, operation, and service; see Cabinet
Configuration Charts.
|
|
|
Two 3540 lb (1618 kg)
steel plates |
H9C10-MC |
| |
|
|
| Power Distribution
Unit - Mandatory |
240V single 16A input power plug
IEC 309, 12 IEC C13 outlets |
H7600-DB |
200240V single 16A input
power plug NEMA L620P, with 12 IEC C13 outlets,
North America/Canada/Japan |
H7600-EB |
|
240V dual 16A input power plugs
IEC 309, with 16 IEC C13 outlets |
H7602-DB |
|
200240V dual 16A input
power plugs NEMA L620P, with 16 IEC C13 outlets, NA/Canada/Japan |
H7602-EB |
| |
|
|
Storage
Shelves Supported in
M-Series Cabinets - Optional |
For supported
StorageWorks shelves, see Step 5b. |
|
|
|
| |
| Step
8 - Networking Adapters/Controllers Mandatory Ethernet Adapter |
| Step 8a
Networking Adapters/Controllers Mandatory |
- Select mandatory Ethernet adapter
|
- Adapters require a minimum of Tru64 UNIX V5.1A or OpenVMS V7.3
|
- Each adapter uses one PCI slot
|
| |
|
|
| |
Maximum
# Supported |
|
| |
Tru64
UNIX |
Open
VMS |
PCI Slot |
|
| Ethernet
10/100/1000 |
PCI (32/64-bit,
33-MHz to 66-MHz) dual-port 10/100 Ethernet (UTP/RJ45s) NIC and Base Module. (One
3X-DE602-TA or 3X-DE602-FA optional add-on daughter card can be combined with this
module.)
NOTE: Use BN25G, BN26M,
BN24Q, BN28Q twisted pair RJ45 cables. |
4 |
4 |
3.3/5 V |
66 MHz |
3X-DE602-BB |
| |
| Step 8b Networking Adapters/Controllers Optional |
| Ethernet
10/100/1000 |
PCI-X/PCI single-port
1000 Mbps (MMF with duplex-SC) Gigabit Ethernet; Tru64 UNIX V5.1B/TruCluster V5.1B
supports up to eight nodes and requires:
http://ftp1.support.compaq.com/
public/unix/v5.1b/t64v51bb1-
c0003000-16672-e-
20030130.README
Tru64 UNIX V5.1A/TruCluster V5.1A supports up to eight nodes and requires:
T64V51AAB21AS0004-20030206.tar
NOTE: Use BN34A, BN34B, or equivalent
with SC connectors. |
8 |
- |
3.3/5 V |
66 MHz |
3X-DEGXA-SA |
PCI-X/PCI single-port
10/100/1000 Mbps (Twisted-Pair Copper with RJ45) Gigabit Ethernet; Tru64 UNIX
V5.1B/TruCluster V5.1B supports up to eight nodes and requires:
http://ftp1.support.compaq.com/
public/unix/v5.1b/t64v51bb1-
c0003000-16672-e-
20030130.README
Tru64 UNIX V5.1A/TruCluster V5.1A supports up to eight
nodes and requires: T64V51AAB21AS0004-20030206.tar
NOTE: Use BN25G, BN26M, BN24Q,
BN28Q twisted pair RJ45 cables. |
8 |
- |
3.3/5 V |
66 MHz |
3X-DEGXA-TA |
| |
|
|
|
|
|
|
| Ethernet
10/100 |
Dual-port 10/100
Ethernet (UTP/RJ45) add-on daughter card for use with the 3X-DE602-BB only. The combined
3X-DE602-BB and 3X-DE602-TA modules, running at 66MHz, provide four 10/100 (UTP/RJ45s)
ports in a single PCI slot option; allows for a maximum of 16 ports per system.
OpenVMS V7.3 requires Tima Kit:
DEC-AXPVMS-VMS73_
LAN-V01004.PCSI
NOTE: 3X-DE602-TA cannot
be used standalone. Use BN25G, BN26M, BN24Q, or BN28Q
twisted pair RJ45 cables. |
4 |
4 |
3.3/5 V |
66 MHz |
3X-DE602-TA |
Single-port 100 Mbps
(MMF/duplex-SC) add-on daughter card for use with the 3X-DE602-BB. The combined
3X-DE602-BB and 3X-DE602-FA modules, running at 66 MHz, provide two 10/100 (UTP/RJ45s) and
one 100Mbps (MMF/SC) ports in a single PCI slot option.
NOTE: 3X-DE602-FA cannot be
used standalone. Use BN34A or BN34B cables. |
4 |
1
per
3X-
DE602
-BB |
3.3/5 V |
66 MHz |
3X-DE602-FA |
| Multi-function
Module |
PCI 32-bit, 33-MHz
multi-function (single-port 10/100 Ethernet UTP/RJ45, Ultra2 LVD SCSI, and 2D graphics)
adapter. Model 1 or 1B requires installation on PCI Bus 0 in slots 1 or 2; Model 2 or 2B
1B requires installation on PCI Bus 0 in slots 3, 6, 9, or 10
NOTE: Tru64 UNIX V5.1A requires Patch
Kit 3:
T64V51AS0003-20010413.tar. Only one 3X-KZPEA-DB allowed on same PCI bus; no multi-head
graphics support; TruCluster support restricted to non-shared SCSI buses only.Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables . |
1 |
1 |
5V |
33 MHz |
3X-DEPVZ-AA |
| 3X-DEPVZ-AA
specific-use 3-meter LVD2 SCSI cable |
|
|
|
|
BN37A-03 |
| |
|
|
|
|
|
|
| FDDI |
PCI (32-bit, 33-MHz)
to FDDI SAS (MMF/duplex-SC) NIC
Use BN34A, BN34B, or BN34D cables. |
4 |
4 |
3.3/5 V |
33 MHz |
3X-DEFPA-AC |
PCI (32-bit, 33-MHz)
to FDDI DAS (MMF/duplex-SC) NIC
Use BN34A, BN34B, or BN34D cables. |
4 |
4 |
3.3/5 V |
33 MHz |
3X-DEFPA-DC |
PCI (32-bit, 33-MHz)
to FDDI DAS (UTP/RJ45) NIC
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
4 |
4 |
3.3/5 V |
33 MHz |
3X-DEFPA-MC |
PCI (32-bit, 33-MHz)
to FDDI SAS (UTP/RJ45) NIC
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
4 |
4 |
3.3/5 V |
33 MHz |
3X-DEFPA-UC |
| |
|
|
|
|
|
|
| FDDI-specific
Cables |
Multimode fiber optic
(MMF) 62.5/125um duplex cable with SC-to-MIC connectors
xx = available lengths: (01, 03, and 10) for 1, 3, and 10 meters |
|
|
|
|
BN34D-xx |
| |
|
|
|
|
|
|
| ATM |
PCI (32-bit, 33-MHz)
to 155 Mbps ATM, Copper NIC with RJ45 connector
Use BN25G-xx, or BN26M-xx cables. |
6 |
6 |
3.3/5 V |
33 MHz |
3X-DAPBA-UA |
PCI (32-bit, 33-MHz)
to 155 Mbps ATM Fiber NIC with SC connector
Use BN34B-xx cable. |
6 |
6 |
3.3/5 V |
33 MHz |
3X-DAPBA-FA |
PCI (32- bit, 33-MHz)
to 622 Mbps ATM Fiber NIC with SC connector
Use BN34B-xx cable. |
4 |
- |
3.3/5 V |
33 MHz |
3X-DAPCA-FA |
| |
|
|
|
|
|
|
| Synchronous
Communications |
PCI (32-bit, 33-MHz)
to Dual-port Intelligent Synchronous Communications NIC Requires at least one
(maximum two) 3X-BC34x sync cable listed below. |
4 |
4 |
3.3/5 V |
33 MHz |
3X-PBXDD-AA |
| PCI (32-bit, 33-MHz)
to Quad-port Intelligent Synchronous Communications NIC Requires at least one
(maximum four) 3X-BC34x sync cable listed below. |
4 |
4 |
3.3/5 V |
33 MHz |
3X-PBXDD-AB |
| |
|
|
|
|
|
|
Synchronous-
specific Cables |
EIA-530 Single-port
cable |
|
3X-BC34G-06 |
| V.24/EIA-232
Single-port cable |
|
3X-BC34L-06 |
| V.11/x.21 Single-port
cable |
|
3X-BC34S-06 |
| V.35 Single-port
cable |
|
3X-BC34T-06 |
| |
|
|
|
|
|
|
| Asynchronous
Communications |
PCI (32-bit, 33-MHz)
to 4-port Async Communications NIC with DB-25 octopus cable
NOTE: The UNIX driver (UNIX Tar File
4001180K.tar) is located at:
http://support.digi.com/
support/indexes/
tru64-xr.html
The OpenVMS driver kit (Filename
4001778L.bin) is located at
http://support.digi.com/
support/drivers/
vms/index-async.html |
2 |
2 |
3.3/5 V |
33 MHz |
PBXDA-BA |
| |
PCI (32-bit, 33-MHz)
to 8-port Async Communications NIC with DB-25 octopus cables
NOTE: The UNIX driver (UNIX Tar File
4001180K.tar) is located at:
http://support.digi.com/
support/indexes/
tru64-xr.html
The OpenVMS driver kit (Filename
4001778L.bin) is located at
http://support.digi.com/
support/drivers/
vms/index-async.html |
2 |
2 |
3.3/5 V |
33 MHz |
PBXDA-BB |
| |
PCI (32-bit, 33-MHz
5.0 Volt Bus-Signaling only) to 4-port Async Communications NIC with DB-25 octopus cable |
2 |
2 |
3.3/5 V |
33 MHz |
PBXDA-AA |
| |
PCI (32-bit, 33-MHz
5.0 Volt Bus-Signaling only) to 8-port Async Communications NIC with DB-25 octopus cables |
2 |
2 |
3.3/5 V |
33 MHz |
PBXDA-AB |
| |
PCI (32-bit, 33-MHz)
to 16-port Async Communications Controller and tabletop 16-port distribution box with RJ45
connectors. |
2 |
2 |
3.3/5 V |
33 MHz |
PBXDA-AC |
| |
|
|
|
|
|
|
| Asynchronous
Connector Adapters |
RJ45-to-DB-25
Converter Cable |
|
|
|
|
CXI01-AC |
| RJ45-to-DEC MJ11
Converter Cable (8 pack) |
|
|
|
|
CXI01-AF |
|
|
| Step
8c Multi-use Cables |
| |
Maximum
# Supported |
|
| |
Tru64
UNIX |
Open
VMS |
PCI
Slot |
|
| Ethernet,
FDDI, ATM |
Multimode fiber optic
(MMF) 62.5/125um duplex cable, with SC-to-ST connectors. Xx = available lengths: (2E, 4E,
01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, and 30 meters |
|
|
|
BN34A-xx |
Multimode fiber optic
(MMF) 62.5/125um duplex cable, with SC-to-SC connectors. Xx = available lengths: (2E, 4E,
01, 03, 10, 20, 30) for 2.4, 4.5,
1, 3, 10, 20, and 30 meters |
|
|
|
BN34B-xx |
| Category 5e
(4-Unshielded Twisted Pairs / UTP) straight-through cable with RJ45-to-RJ45 connectors for
system to switch, repeater, or hub connectivity. Xx = available lengths: (0B, 0E, 01, 03,
04, 07) for 0.2, 0.5, 1, 3, 4, and 7 meters |
|
|
|
BN25G-xx |
| Category 5e
(4-Twisted Pairs, Screened/ ScTP) straight-through cable with RJ45-to-RJ45 connectors for
system to switch, repeater, or hub connectivity. Xx = available lengths: (0E, 01, 03, 04,
07) for 0.5, 1, 3, 4, and 7 meters |
|
|
|
BN26M-xx |
Category 5e
(4-Unshielded Twisted Pairs / UTP) Xover cable with RJ45-to-RJ45 connectors for system to
switch, repeater, or hub connectivity.
Xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters |
|
|
|
BN24Q-xx |
Category 5e
(4-Twisted Pairs, Screened / ScTP) Xover cable with RJ45-to-RJ45 connectors for system to
switch, repeater, or hub connectivity.
Xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters |
|
|
|
BN28Q-xx |
| |
| Step 9 - MEMORY CHANNEL - Optional |
| Tru64 UNIX Systems (V5.1A) |
Each system node in the cluster
requires a TruCluster software license
(QL-6BRAE-AA) or TruCluster Plus Software Package (QP-6R9AE-AA) |
|
| |
|
|
| OpenVMS Systems |
OpenVMS V7.3 and OpenVMS Cluster
license (QL-MUZAE-AA) are required |
|
| |
|
|
| Configuring Information |
- Up to two PCI-to-System Area Network adapters (CCMAB-AA) are supported in a single
system.
|
|
|
- Two-node clusters can be configured by ordering a CCMAB-AA for each node and one
BN39B-04 or BN39B-10 cable; cable connects directly to CCMAB-AA in each node.
|
|
|
- Two-node clusters can also be configured by ordering two CCMAB-A adapters for each node
and two BN39B-04 or BN39B-10 cables; cables connect directly to CCMAB-AA in each node.
|
|
|
- For a two-node cluster that will not need to be rebooted when adding additional members,
order one CCMAB-AA adapter and one BN39B-04 or BN39B-10 cable for each node, and one
CCMHB-AA hub for the cluster.
|
|
|
- For three- or four- node clusters, order one CCMAB-AA adapter and one
BN39B-04 or BN39B-10 cable for each node, and one CCMHB-AA hub for the cluster. If two
CCMAB-AAs are configured in each system, a second CCMHB-AA is required.
|
|
|
- CCMHB-AA includes four CCMLB-AA line cards and supports up to four nodes; expansion up
to eight system nodes can be achieved by adding up to four CCMLB-AA line cards.
|
|
|
- If nodes must be separated by a distance longer than standard copper cables allow the
CCMFB option converts the output of the standard CCMAB controller or CCMLB line card to
single-mode fiber optic cable. The fiber optic connection may be up to 2,000 meters long
between two CCMAB controllers connected in virtual hub mode, or 3,000 meters between a
CCMAB controller and a CCMHB hub. (The connection from the CCMHB hub to a second system
may also be 3,000 meters.) The CCMFB option requires a second PCI slot in the system from
which it draws power only. It is normally connected to the corresponding CCMAB controller
with the short BN39B-01 cable. The CCMFB is also used in the CCMHB hub where it occupies a
slot normally used by the CCMLB line card, limiting expansion to four radial fiber optic
connections.
|
|
|
- CCMHB-BA hub expansion box provides additional slots for up to eight fiber optic
connections. Two standard length single-mode fiber optic cables are available (BN34R-10
and BN34R-31); however, users normally provide this fiber optic connection. Fiber optic
connectivity is completely transparent to the systems using it and has no performance
impact.
|
|
|
NOTE:
When configuring Model 1B or Model 1, Model 2B or Model 2 with two Memory Channel
Controllers (CCMAB-AA) installed in hose 0 only, all nodes in a Memory Channel cluster
must have the window size jumper set to the same size, specifically 128. When configuring
Model 3B or Model 3 with two Memory Channel Controllers (CCMAB-AA), all nodes in a Memory
Channel cluster must have the window size jumper set to the same size, specifically 512 or
128; Memory Channel Hub must be installed on a different hose (hose 0, 1, or 2). Refer to
the TruCluster QuickSpecs for Memory Channel details. |
| |
|
Model 1B (1 GHz)
Model 1 (1.25 GHz) |
Model 2B (1 GHz)
Model 2 (1.25 GHz) |
Model 3B (1 GHz)
Model 3 (1.25 GHz) |
| 128K I/O |
128K I/O |
512K or 128K I/O |
| Use for new or
existing clusters; if existing cluster at 512K, shut down and configure all nodes to 128K |
Use for new or
existing clusters; if existing cluster at 512K, shut down and configure all nodes to 128K |
Online add-on to
existing 512K configured clusters, OR, use for existing clusters at 128K. If existing
cluster at 512K, shut down and configure all nodes to 128K |
| Supports dual-rail,
(two) Memory Channel controllers on single PCI Bus 0 |
Supports dual-rail,
(two)
Memory Channel controllers on single PCI Bus 0 |
Supports dual-rail,
(two)
Memory Channel controllers on separate PCI Bus (0, 1, or 2) |
| |
| MEMORY CHANNEL
Controller/ System Area Network Hub |
PCI-to-System Area
Network Controller, maximum two 5V/33 MHz |
CCMAB-AA |
| System
Area Network Hub with four line cards; includes BN19P-2E power cord for Canada, Japan, and
U.S. - for other regions, order appropriate power cord from the
following list: |
CCMHB-AA |
|
|
Hub expansion box with no line
cards |
CCMHB-BA |
|
|
Expansion line card for CCMHB hub |
CCMLB-AA |
|
|
1-meter cable for CCMAB and CCMHB |
BN39B-01 |
|
|
4-meter cable for CCMAB and CCMHB |
BN39B-04 |
|
|
10-meter cable for CCMAB and
CCMHB |
BN39B-10 |
|
|
Copper-to-single mode fiber optic
converter - 5V (clock not affected) |
CCMFB-AA |
|
|
Rackmount kit (3U) for CCMHB
(Memory Channel Hub II); required for mounting in H9A1x cabinets. |
3X-BA61R-MC |
|
|
Power cord for rackmount CCMHB
hub |
BN35S-02 |
| |
|
|
| MEMORY CHANNEL
Power Cords |
Australia, New
Zealand (103541-011) |
BN19H-2E |
| Central Europe |
BN19C-2E |
|
Denmark (103541-481) |
BN19K-2E |
|
Egypt, India
(103541-AR1) |
BN19S-2E |
|
Ireland, United
Kingdom |
BN19A-2E |
|
Israel |
BN18L-2E |
|
Italy (103541-461) |
BN35M-02 |
|
Japan, 2.5-meter,
Dentori approved |
3X-BN46F-02 |
|
Switzerland
(103541-511) |
BN19E-2E |
|
Republic of China
(103541-001) |
BN19H-2E |
|
NOTE: When
using MEMORY CHANNEL, refer to the TruCluster QuickSpecs for configuration guidelines and
restrictions: http://www.compaq.com/products/quickspecs/Division/10657.html
The MEMORY CHANNEL controller,
CCMAB-AA, must be revision D01 or later.
NOTE: This website is available in English only. |
| |
| Step 10 - Storage Adapters/Controllers - Mandatory |
| NOTE:
Refer to the following chart when configuring adapters, shelves, and disks. |
| AlphaServer ES45
Configuration Chart for Storage Adapters |
| Storage Adapter |
Shelf |
Disk Drive |
Tru64 UNIX |
OpenVMS |
Linux |
| 3X-KZPCA-AA |
BA610-6D
DS-SL13R-xx |
3R-A0xxx-AA
1-inch Universal
3R-A1xxx-AA 1-inch Universal
3R-A3xxx-AA 1-inch Universal |
V5.1A |
V7.3 |
RedHat
V6.2
SuSE V6.3
Requires BA610 |
| 3.3/5 V |
33 MHz |
| 3X-KZPEA-DB |
BA610-6D
DS-SL13R-Bx |
3R-A0xxx-AA
1-inch Universal
3R-A1xxx-AA 1-inch Universal
3R-A3xxx-AA 1-inch Universal |
V5.1A |
V7.3 |
- |
| 3.3/5 V |
66 MHz |
| 3X-KZPBA-CC |
External HSZ80 |
DS-RZ1xx-VW |
V5.1A |
V7.3 |
- |
| 3.3/5 V |
33 MHz |
| DS-KGPSA-DA |
External
HSG80 |
3R-A0xxx-AA
1-inch Universal
3R-A1xxx-AA 1-inch Universal
3R-A3xxx-AA 1-inch Universal |
V5.1A |
V7.3 |
- |
| 3.3/5 V |
66 MHz |
| RAID
Controller |
| DS-KZPCC-AC/CE |
BA610-6D
DS-SL13R-xx |
3R-A0xxx-AA 1-inch
Universal
3R-A1xxx-AA 1-inch Universal
3R-A3xxx-AA 1-inch Universal |
V5.1A |
- |
- |
| 3X-KZPDC-BE/DF |
BA610-6D
DS-SL13R-xx |
3R-A0xxx-AA 1-inch
Universal
3R-A1xxx-AA 1-inch Universal
3R-A3xxx-AA 1-inch Universal |
V5.1B/V5.1A |
V7.3-1 |
|
| DS-SWLA4-PD |
|
|
- |
- |
RedHat V7.2 |
| |
Maximum #
Supported |
| |
Tru64
UNIX |
Open
VMS |
PCI
Slot |
|
| SCSI |
PCI 2-port Ultra3
(LVD2) SCSI adapter, 64-bit/66-MHz dual-channel (uses one PCI slot); includes internal
68-pin and external 68-pin VHDCI connectors; requires 3X-BC56J-xx cable to connect adapter
to DS-SL13R-Bx shelf; supports internal SDLT tape drives and external SDLT tape libraries.
HSZxx RAID controllers not supported. No support for Model 4314R single-bus shelves with
3X-KZPEA-DB adapter. Tru64 UNIX requires graphics adapter to run console utilities (RUN
BIOS).
3X-KZPEA-DB adapter supports shared SCSI under Tru64 UNIX V5.1B and TruCluster V5.1B with
Initial Patch Kit installed; supports maximum of two nodes per shared bus; requires
3X-BN55A-01 Y-cable and connector plug assembly, and
3X-H32CT-AA external LVD terminator per shared bus.
NOTE: Tru64 UNIX Initial Patch Kit for
V5.1B is located at:
http://ftp1.support.compaq.com/
public/unix/v5.1b |
6 |
6 |
3.3/
5 V |
66 MHz |
3X-KZPEA-DB |
| |
Ultra160 cable, VHDCI
to VHDCI (341174-B21 6-feet,
341175-B21 12-feet, 164604-B21 24-feet)
xx = 02 (6-feet), 03 (12-feet), 04 (24-feet) |
|
|
|
|
3X-BC56J-xx |
|
PCI 1-port Ultra2
(LVD) SCSI adapter, 32-bit/33-MHz, single-channel (uses one PCI slot); includes internal
68-pin and external 68-pin HD connectors; order BN38C-xx cable to connect adapter to
Ultra3 shelf, or order VHDCI converter (BN38E-0B) for use with included cable; HSZxx RAID
controllers not supported. No support for shared SCSI.
Linux-supported option; maximum one per system |
6 |
6 |
3.3/5 V |
33 MHz |
3X-KZPCA-AA |
|
68-pin HD
male-to-VHDCI male UltraSCSI cable;
xx = 02, 03, 05, 10, 20 meters |
|
|
|
|
BN38C-xx |
|
PCI 1-port UltraSCSI
wide differential 32-bit/33-MHz PCI adapter (uses one PCI slot); includes external 68-pin
HD connector, requires BN38C-xx cable (2 to 20 meters) to connect adapter to differential
UltraSCSI shelf or RAID controller |
4 |
4 |
3.3/5 V |
33 MHz |
3X-KZPBA-CC |
|
68-pin HD
male-to-VHDCI male UltraSCSI cable;
xx = 02, 03, 05, 10, 20 meters |
|
|
|
|
BN38C-xx |
| Fibre Channel |
PCI to 2-Gb Fibre
Channel adapter, 64-bit/66-MHz, single-channel (261329-B21)
NOTE: When used in a switched
standalone or TruCluster environment (with Fibre Channel Switches see Step 11), a
maximum of six adapters is supported. Arbitrated loop is not supported. Tru64 UNIX V 5.1A
requires Patch Kit:
T64V51AB01AS0001-
20020116.tar |
See Note |
See Note |
3.3/5 V |
66 MHz |
DS-KGPSA-DA
|
| |
See Fibre Channel
cables and switches, Step 11 |
|
|
|
|
|
| |
|
|
|
|
|
|
| Multi-function
Module |
PCI 32-bit, 33-MHz
multi-function (single-port 10/100 Ethernet UTP/RJ45, Ultra2 LVD SCSI, and 2D graphics)
adapter. Model 1 or 1B requires installation on PCI Bus 0 in slots 1 or 2; Model 2 or 2B
1B requires installation on PCI Bus 0 in slots 3, 6, 9, or 10
NOTE: Tru64 UNIX V5.1A requires Patch
Kit 3:
T64V51AS0003-20010413.tar. Only one 3X-KZPEA-DB allowed on same PCI bus; no multi-head
graphics support; TruCluster support restricted to non-shared SCSI buses only.Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables . |
1 |
1 |
5V |
33
MHz |
3X-DEPVZ-AA |
| |
3X-DEPVZ-AA
specific-use 3-meter LVD2 SCSI cable |
|
|
|
|
BN37A-03 |
| |
|
|
|
|
|
|
| RAID |
PCI 3-port PCI to
Ultra2, 64-bit, LVD backplane RAID controller with 64-MB cache (uses one PCI slot);
requires connection to BA610-6D disk card cage or DS-SL13R-xx Universal StorageWorks
shelf; requires graphics adapter to run console utilities (SMOR) or alternatively, this
can run via a serial line using a PC and terminal emulation software. NOTE: DS-KZPCC-xx RAID controllers require
Tru64 UNIX V5.1A;
TruCluster support with V5.1A requires Initial Patch Kit: T64V51AB01AS0001-
20020116.TAR |
8 |
- |
3.3/5 V |
33 MHz |
DS-KZPCC-CE |
|
PCI 1-port PCI to
Ultra2, 64-bit, LVD backplane RAID controller with 16-MB cache (uses one PCI slot);
requires connection to BA610-6D disk card cage or DS-SL13R-xx Universal StorageWorks
shelf; requires graphics adapter to run console utilities (SMOR) or alternatively, this
can run via a serial line using a PC and terminal emulation software.
NOTE: DS-KZPCC-xx RAID controllers
require Tru64 UNIX V5.1A;
TruCluster support with V5.1A requires Initial Patch Kit: T64V51AB01AS0001-2
0020116.TAR |
8 |
- |
3.3/5 V |
33 MHz |
DS-KZPCC-AC |
|
PCI 2-port PCI to
Ultra3, 64-bit, 66 MHz, LVD backplane RAID controller with 128-MB cache (uses one PCI
slot); requires connection to DS-SL13R-xx shelves or BA610-6D card cage.
NOTE: Tru64 UNIX requires V5.1B
and TruCluster V5.1B (non- shared buses only) with Initial Patch Kit:T64V51BV1AS0001-
20021229.tar
Tru64 UNIX requires V5.1A with Initial Patch Kit:
T64V51AV21AS0004-
20030206.tar
NOTE: No host-based volume shadowing or shared bus support under OpenVMS. |
6 per system, 3 per
PCI bus |
6 per
system, 3 per PCI
bus |
3.3/5 V |
66 MHz |
3X-KZPDC-BE |
|
PCI 4-port PCI to
Ultra3, 64-bit, 66 MHz, LVD backplane RAID controller with 256-MB cache (uses one PCI
slot); requires connection to DS-SL13R-xx shelves or BA610-6D card cage.
NOTE: Tru64 UNIX requires V5.1B
and TruCluster V5.1B
(non-shared buses only) with Initial Patch Kit:T64V51BV1AS0001-20021229.tar
Tru64 UNIX requires V5.1A with Initial Patch Kit:
T64V51AV21AS0004-
20030206.tar
NOTE: No host-based volume shadowing or shared bus support under OpenVMS. |
6 per system, 3 per
PCI bus |
6 per
system,3 per PCI bus |
3.3/5 V |
66 MHz |
3X-KZPDC-DF |
|
PCI to Fibre Channel
adapter, 64-bit single-channel (uses one PCI slot); supported only on Linux, maximum of 4
adapters; requires 3X-KZPCA-AA SCSI adapter and must be installed in 66MHz PCI bus slots
only; supports HSG80 controller in transparent failover mode only. No support for
mulit-path and multi-bus modes. |
- |
- |
|
66 MHz only |
DS-SWLA4-PD |
| |
|
|
|
|
|
|
| CI |
PCI CI adapter for
OpenVMS systems only; requires two 5.0 V PCI slots and CI cable for each adapter
NOTE: DS-HSJ80-xx controllers
are supported with CIPCA on ES45 systems. |
- |
2 |
5 V |
33 MHz |
CIPCA-BA |
| |
CI cable |
|
|
|
|
BNCIA-xx |
| |
| Step 11 - Storage Devices - Optional |
| Step
11a - Tape Devices |
|
For detailed tape drive
information see http://www.compaq.com/products/storageworks/
sitemap.html#tapedrives
NOTE: This web site is available
in English only. |
|
|
- System includes embedded 1.44-MB diskette drive
|
|
|
- System includes embedded 5.25-inch half-height 600-MB 16X ATPI DVD-ROM drive
|
|
|
- Removable media slots provide support for up to two 5.25-inch half-height devices, or
one 5.25-inch full-height removable media device; select up to two AIT or DAT devices or
one DLT/SDLT tape device
|
|
|
- For maximum performance, tape libraries must be configured with Fast Wide Differential
(FWD) controllers for tape backup
|
|
| |
|
|
| AIT Tape Drives (Internal) |
- The following AIT tape drives are supported with 3X-KZPCA-AA and 3X-KZPEA-DB adapters.
|
|
|
AIT 5.25-inch half-height
35/70-GB 8-mm Wide UltraSCSI tape drive, top gun blue; supports KZPBA-CA, KZPCM-DA
adapters and SCSI cable (3X-BN46M-01) |
3X-SZ35X-LB |
|
AIT 5.25-inch half-height
35/70-GB 8-mm LVD UltraSCSI tape drive, carbon black |
3R-A2392-AA |
|
AIT 5.25-inch half-height
50/100-GB 8-mm Ultra2 (LVD) SCSI tape drive, top gun blue; requires SCSI cable
(3X-BN46M-01) |
3X-SZ50X-LB |
|
AIT 5.25-inch half-height
50/100-GB 8-mm Ultra2 (LVD) SCSI tape drive, carbon black; requires SCSI cable
(3X-BN46M-01) (157766-B22) |
3R-A3753-AA |
|
AIT 5.25-inch half-height
100/200-GB 8-mm Ultra3 SCSI tape drive; supports
3X-KZPEA-DB, 3X-KZPCA-AA, or 3X-DEPVZ-AA LVD adapter, carbon black |
3R-A3623-AA |
|
1-meter Ultra2 68-pin LVD cable
with two connectors, multimode terminator and two wide-to-narrow adapters
(for connection of 50-pin narrow devices) |
3X-BN46M-01 |
| |
|
|
| AIT Tabletop Tape Drives |
AIT 35/70-GB 8-mm LVD tabletop
tape drive, carbon black, North America |
216885-001 |
|
Same as above, International |
216885-B31 |
|
Same as above, Japan |
216885-291 |
|
AIT 50/100-GB 8-mm SCSI tabletop
tape drive, carbon black, with 120V North American power cord |
157767-002 |
|
Same as above, International |
157767-B32 |
|
Same as above, Japan |
157767-292 |
|
AIT 100/200-GB 8-mm Ultra3 SCSI
tabletop tape drive; supports 3X-KZPEA-DB,
3X-KZPCA-AA, or 3X-DEPVZ-AA LVD adapters, North America, carbon black |
249160-001 |
|
Same as above, International |
249160-B31 |
| |
| AIT Hot-plug Tape Drives |
AIT 35/70-GB hot plug LVD
Universal tape drive, uses two slots in BA610-6D or 43xxx shelves |
3R-A2396-AA |
|
AIT 50/100-GB hot plug LVD
Universal tape drive, uses two slots in BA610-6D or 43xxx shelves |
3R-A2779-AA |
|
AIT 100/200-GB hot plug LVD
Universal tape drive, uses two slots in BA610-6D or 43xxx shelves; supports 3X-KZPEA-DB,
3X-KZPCA-AA, or 3X-DEPVZ-AA LVD adapters |
3R-A3621-AA |
| |
|
|
| AIT Autoloaders |
AIT 35-GB tabletop autoloader, 8
cartridge, U.S. |
292355-001 |
|
Same as above, International |
292355-B31 |
|
AIT 35-GB rackmount autoloader, 8
cartridge, U.S. |
280349-001 |
|
Same as above, International |
280349-B31 |
|
AIT rail kit for autoloader |
284930-001 |
| |
|
|
| AIT Tape Libraries |
SSL2020 AIT tabletop library with
one AIT 50-GB drive and 20 slots, LVD |
175195-B21 |
|
SSL2020 AIT tabletop library with
two AIT 50-GB drives and 20 slots, LVD |
175195-B22 |
|
SSL2020 AIT rackmount library
with one AIT 50-GB drive and 20 slots, LVD |
175196-B21 |
|
SSL2020 AIT rackmount library
with two AIT 50-GB tape drives and 20 slots, LVD |
175196-B22 |
| |
|
|
| DAT Tape Drives (Internal) |
- Select up to two DAT devices.
|
|
- The following DAT tape drives are supported with 3X-KZPCA-AA and 3X-KZPEA-DB adapters.
|
|
|
DAT 12/24-GB 4-mm 5.25-inch
half-height SCSI tape drive, top gun blue; requires SCSI cable (3X-BN46M-01) |
TLZ10-LB |
|
DAT 20/40-GB 4-mm
5.25-inch half-height Ultra2 (LVD) SCSI tape drive, top gun blue; requires SCSI cable
(3X-BN46M-01) |
3X-SD20X-LB |
|
DAT 20/40-GB 4-mm 5.25-inch
half-height Ultra2 (LVD) SCSI tape drive, carbon black; requires SCSI cable (3X-BN46M-01)
(157769-B22) |
3R-A3752-AA |
|
1-meter Ultra2 68-pin LVD cable
with two connectors, multimode terminator and two wide-to-narrow adapters (for connection
of 50-pin narrow devices) |
3X-BN46M-01 |
|
DAT 12/24-GB 4-mm narrow
single-ended tabletop SCSI tape drive in StorageWorks carrier; Linux supported option;
maximum one per system |
DS-TLZ10-DB |
| |
|
|
| DAT Tabletop Tape Drives |
DAT 20/40-GB 4-mm Wide Ultra2
(LVD) tabletop SCSI tape drive with 120V North American power cord, carbon black; requires
Ultra2 (LVD) adapter |
157770-002 |
|
Same as above, International |
157770-B32 |
|
Same as above, Japan |
157770-292 |
| |
|
|
| DAT Hot-plug Tape Drive |
DAT 20/40-GB DDS4 hot-plug LVD
Universal tape drive, uses two slots in BA610-6D or 43xxx shelves; Linux supported
option; maximum one per system |
3R-A2780-AA |
| |
|
|
| DAT Autoloaders |
DAT 20/40-GB auto loader
external; requires VHDCI BN38A-0B adapter and BN23G-xx SCSI cable, North America |
166505-001 |
|
Same as above, International |
166505-B31 |
|
Same as above, Japan |
166505-291 |
| |
|
|
| DLT/SDLT Tape Drives (Internal) |
- Select one DLT/SDLT tape device
- The following DLT/SDLT tape drives are supported with 3X-KZPCA-AA or 3X-KZPEA-DB LVD
adapters
|
|
|
DLT8000 40/80-GB tape drive |
146196-B22 |
|
SDLT 110/220-GB 3U/5U tape drive |
192106-B25 |
|
SDLT 160/320-GB 3U/5U tape drive,
carbon black |
257319-B21 |
| |
| DLT/SDLT Tabletop Tape Drives |
SDLT tabletop
110/220-GB external tape drive, carbon black - TruCluster
support restricted to non-shared buses only - U.S. |
192103-002 |
|
Same as above
International |
192103-B32 |
|
Same as above
Japan |
192103-292 |
| |
|
|
|
SDLT tabletop
160/320-GB external tape drive, carbon black, U.S. |
257319-001 |
|
Same as above,
International |
257319-B31 |
|
Same as above, Japan |
257319-291 |
| |
|
|
|
Rackmount kit for
H9Axx M-Series cabinets required for mounting MSL5000 series in M-Series cabinets |
254795-001 |
| |
|
|
|
MSL5026DLX, DLT
tabletop library with one 40/80-GB DLT tape drive, LVD |
231821-B21 |
|
MSL5026DLX, DLT
tabletop library with two 40/80-GB DLT tape drives, LVD |
231821-B22 |
|
MSL5026DLX or
MSL5026SL, DLT/SDLT rackmount library, 0 drives; requires rackmount kit (254795-001) |
231979-B21 |
|
MSL5026DLX, DLT
rackmount library with one 40/80-GB DLT tape drive, LVD; requires rackmount kit
(254795-001) |
231891-B21 |
|
MSL5026DLX, DLT
rackmount library with two 40/80-GB DLT tape drives, LVD; requires rackmount kit
(254795-001) |
231891-B22 |
| |
|
|
|
MSL5026SL, SDLT
tabletop library with one 110/220-GB SDLT tape drive, LVD |
302511-B21 |
|
MSL5026SL, SDLT
tabletop library with two 110/220-GB SDLT tape drives, LVD |
302511-B22 |
|
MSL5026SL, SDLT
rackmount library with one 110/220-GB SDLT tape drive, LVD; requires rackmount kit
(254795-001) |
302512-B21 |
|
MSL5026SL, SDLT
rackmount library with two 110/220-GB SDLT tape drives, LVD; requires rackmount kit
(254795-001) |
302512-B22 |
| |
|
|
|
MSL5026S2, SDLT2
tabletop library with one 160/320-GB SDLT tape drive, LVD |
293-473-B21 |
|
MSL5026S2, SDLT2
tabletop library with two 160/320-GB SDLT tape drives, LVD |
293473-B22 |
|
MSL5026S2 SDLT
rackmount library, 0 drives, LVD requires rackmount kit (254795-001) |
293472-B21 |
|
MSL5026S2, SDLT2
rackmount library with one 160/320-GB SDLT tape drive, LVD |
293472-B22 |
|
MSL5026S2, SDLT2
rackmount library with two 160/320-GB SDLT tape drive, LVD |
293472-B23 |
|
MSL5026S2, SDLT2
rackmount library with one 160/320-GB SDLT tape drive with Fibre Channel, LVD |
293472-B24 |
|
MSL5026S2, SDLT2
rackmount library with two 160/320-GB SDLT tape drive with Fibre Channel, LVD |
293472-B25 |
| |
|
|
|
MSL5052SL SDLT
tabletop library with two 110/220-GB drives, LVD |
249490-B21 |
|
MSL5052SL SDLT
rackmount library, 0 drives, LVD requires rackmount kit
(254795-001) |
255102-B21 |
|
MSL5052SL SDLT
rackmount library with two 110/220-GB drives, LVD requires rackmount kit
(254795-001) |
249491-B21 |
|
MSL5052SL SDLT
110/220-GB drive field upgrade, LVD |
231823-B22 |
| |
|
|
|
MSL5052S2, SDLT2
tabletop library with two 160/320-GB SDLT tape drives, LVD, graphite |
293476-B21 |
|
MSL5052S2, SDLT2
rackmount library with two 160/320-GB SDLT tape drive, LVD |
293474-B21 |
|
MSL5052S2, SDLT2
rackmount library with two 160/320-GB SDLT tape drive with Fibre Channel, LVD |
293474-B24 |
| |
|
|
| DLT/SDLT Tape Libraries |
ESL9198SL SDLT tape
library with four 110/220-GB SDLT tape drives, 198 slots |
234618-B21 |
|
ESL9198SL SDLT tape
library with eight 110/220-GB SDLT tape drives, 198 slots |
234618-B22 |
| |
|
|
|
ESL9322S2 SDLT2 tape
library, two 160/320-GB SDLT tape drives, 222 slots |
293409-B22 |
|
ESL9322S2 SDLT2 tape
library, eight 160/320-GB SDLT tape drives, 222 slots |
293409-B28 |
|
ESL9322S2 SDLT2 tape
library, two 160/320-GB SDLT tape drives, 322 slots |
293410-B22 |
|
ESL9322S2 SDLT2 tape
library, eight 160/320-GB SDLT tape drives, 322 slots |
293410-B28 |
| |
|
|
|
ESL9326SL SDLT tape
library with six 110/220-GB SDLT tape drives, LVD |
234615-B21 |
|
ESL9326SL SDLT tape
library with eight 110/220-GB SDLT tape drives, LVD |
234615-B22 |
|
ESL9326SL SDLT tape
library with 16 110/220-GB SDLT tape drives, LVD |
234615-B26 |
| |
|
|
|
ESL9595S2 SDLT2 tape
library, two 160/320-GB SDLT tape drives, 400 slots |
293411-B22 |
|
ESL9595S2 SDLT2 tape
library, 16 160/320-GB SDLT tape drives, 400 slots |
293411-B28 |
|
ESL9595S2 SDLT2 tape
library, two 160/320-GB SDLT tape drives, 500 slots |
293412-B22 |
|
ESL9595S2 SDLT2 tape
library, 16 160/320-GB SDLT tape drives, 500 slots |
293412-B28 |
|
ESL9595S2 SDLT2 tape
library, two 160/320-GB SDLT tape drives, 595 slots |
293413-B22 |
|
ESL9595S2 SDLT2 tape
library, 16 160/320-GB SDLT tape drives, 595 slots |
293413-B28 |
| |
|
|
|
ESL9595SL SDLT tape
library, 0 drives, 400 slots |
274672-B21 |
|
ESL9595SL SDLT tape
library, 2 drives, 400 slots |
274672-B22 |
|
ESL9595SL SDLT tape
library, 16 drives, 400 slots |
274672-B28 |
|
ESL9595SL SDLT tape
library, 0 drives, 500 slots |
281627-B21 |
|
ESL9595SL SDLT tape
library, 2 drives, 500 slots |
281627-B22 |
|
ESL9595SL SDLT tape
library, 16 drives, 500 slots |
281627-B28 |
|
ESL9595SL SDLT tape
library, 0 drives, 595 slots |
281628-B21 |
|
ESL9595SL SDLT tape
library, 2 drives, 595 slots |
281628-B22 |
|
ESL9595SL SDLT tape
library, 16 drives, 595 slots |
281628-B28 |
|
NOTE:
The following options are supported with 3X-KZPCA-AA or 3X-KZPEA-DB LVD adapters. |
|
| |
| 3U Rackmount Tape Drive
Enclosure |
3U LVD Rackmount Tape
Drive Enclosure for use in H9Axx M-Series Cabinets, 0 drives, carbon black |
274338-B21 |
|
Rackmount Kit for
H9Axx M-Series Cabinets, carbon black required for mounting 3U Rackmount Tape Drive
Enclosure in M-Series cabinet |
3R-A3804-AA
|
|
NOTE:
The 3U Rackmount Tape Enclosure supports up to four internal half-height removable
devices, or up to two full-height devices; select up to four AIT or DAT devices or two
DLT/SDLT devices with 3U Rackmount Tape Enclosure (274338-B21) or select one of the
preconfigured configurations listed below. |
|
|
AIT 35/70-GB 3U tape
drive, carbon black |
216884-B21 |
|
AIT 50/100-GB 3U tape
drive, carbon black, (157766-B22) |
3R-A3753-AA |
|
DAT 20/40-GB 3U tape
drive, carbon black, 157769-B22) |
3R-A3752-AA |
|
DLT8000 40/80-GB tape
drive |
146196-B22 |
|
SDLT 110/220-GB tape
drive |
192106-B25 |
|
SDLT 160/320-GB tape
drive, carbon black |
257319-B21 |
|
Preconfigured
configurations |
|
|
|
AIT 50-GB 3U rackmount kit,
carbon black |
274333-B21 |
|
|
DLT 40/80-GB, 3U rackmount kit,
carbon black |
274332-B21 |
|
|
DLT 40/80-GB, dual-drive, 3U
rackmount kit, carbon black |
274335-B21 |
|
|
SDLT 110/220-GB, 3U rackmount
kit, carbon black |
274331-B21 |
|
|
SDLT 110/220-GB, dual-drive, 3U
rackmount kit, carbon black |
274334-B21 |
| |
|
|
| 5U Rackmount Tape
Drive Enclosure |
5U LVD Rackmount Tape
Drive Enclosure for use in H9Axx M-Series Cabinets, 0 drives, carbon black |
274339-B21 |
| Rackmount Kit for
H9Axx M-Series Cabinets, carbon black - required for mounting
5U Rackmount Tape Drive Enclosure in M-Series Cabinet |
254795-001 |
|
NOTE:
The 5U Rackmount Tape Enclosure supports four full-height removable devices; select up to
four DLT or SDLT devices with 5U Rackmount Tape Enclosure (274339-B21) or select one of
the preconfigured configurations listed below. |
|
|
DLT8000 40/80-GB tape
drive |
146196-B22 |
|
SDLT 110/220-GB tape
drive |
192106-B25 |
|
SDLT 160/320-GB tape
drive, carbon black |
257319-B21 |
|
Preconfigured
configurations |
|
|
|
SDLT 110/220-GB Tape Array III,
5U rackmount kit, carbon black |
274336-B21 |
|
|
DLT 40/80-GB Tape Array III, 5U
rackmount kit, carbon black |
274337-B21 |
|
|
DLT Tape Array III, Model 0
enclosure, U.S. |
168047-001 |
|
|
Same as above, International |
168047-B31 |
|
|
Same as above, Japan |
168047-291 |
| |
| Step
11b Modular Data Routers |
| Network Storage Routers |
NOTE:
The following Network Storage Routers are supported with MSL5000 and ESL9000 tape
libraries: |
|
|
NSR M2402 Two Fibre
Channel x 4 HVD FC to SCSI Data Router, Tru64 UNIX and OpenVMS (262654-B21) |
3R-A3741-AA |
|
NSR M2402 Two Fibre
Channel x 4 LVD FC to SCSI Data Router, Tru64 UNIX and OpenVMS (262653-B21) |
3R-A3740-AA |
|
NSR e1200 One Fibre
Channel x 2 LVD FC to SCSI Data Router, Tru64 UNIX and OpenVMS, carbon black (262672-B21) |
3R-A3746-AA |
|
NSR e2400 Two Fibre
Channel x 4 LVD FC to SCSI Data Router with card cage, Tru64 UNIX and OpenVMS, carbon
black (262665-B21) |
3R-A3935-AA |
|
NSR e2400 Two Fibre
Channel x 4 LVD FC to SCSI Data Router with no card cage, Tru64 UNIX and OpenVMS, carbon
black (262664-B21) |
3R-A3745-AA |
|
NSR N1200 One Fibre
Channel x 2 LVD FC to SCSI Data Router, Tru64 UNIX and OpenVMS, supports tape drives and
tape libraries (280823-B21) |
3R-A3747-AA |
| |
|
|
| Step
11c External Storage Solutions/Controllers |
|
Enterprise Virtual Array Model
2C6D-B 60-Hz, includes 41U graphite storage cabinet, M3220 controller assembly with dual
HSV110 controllers, six M5214 dual-redundant FC loop 14-bay drive enclosures, four 12-port
FC loop switches; requires
DS-KGPSA-xx (283198-B21) |
DS-SV110-JA |
|
Enterprise Virtual Array Model
2C6D-B 50-Hz, includes 41U graphite storage cabinet, M3220 controller assembly with dual
HSV110 controllers, six M5214 dual-redundant FC loop 14-bay drive enclosures, four 12-port
FC loop switches; requires
DS-KGPSA-xx (283198-B22) |
DS-SV110-JB |
|
Enterprise Virtual Array Model
2C12D-B 60-Hz, includes 41U graphite storage cabinet, M3220 controller assembly with dual
HSV110 controllers, 12 M5214 dual-redundant FC loop 14-bay drive enclosures, four 12-port
FC loop switches; requires DS-KGPSA-xx, (283199-B21) |
DS-SV110-KA |
|
Enterprise Virtual Array Model
2C12D-B 50-Hz, includes 41U graphite storage cabinet, M3220 controller assembly with dual
HSV110 controllers, 12 M5214 dual-redundant FC loop 14-bay drive enclosures, four 12-port
FC loop switches; requires DS-KGPSA-xx (283199-B22) |
DS-SV110-KB |
|
Enterprise Virtual Array Model
8C8D 60-Hz, includes 41U graphite storage cabinet, four M3220 controller assembly with
eight HSV110 controllers, eight M5214 dual FC loop
14-bay drive enclosures; requires DS-KGPSA-xx (283263-B21) |
DS-SV110-LA |
|
Enterprise Virtual Array Model
8C8D 50-Hz, includes 41U graphite storage cabinet, four M3220 controller assembly, with
eight HSV110 controllers, eight M5214 dual FC loop
14-bay drive enclosures; requires DS-KGPSA-xx (283263-B22) |
DS-SV110-LB |
|
Enterprise Virtual Array Model
0C6D-B 60-Hz, includes 41U graphite storage cabinet, six M5214 dual-redundant FC loop
14-bay drive enclosures, 12 16.4-feet/5-meter interconnect cables (to 2C12D-B); requires
DS-KGPSA-xx (283264-B21) |
DS-SV110-MA |
|
Enterprise Virtual Array Model
0C6D-B 50-Hz, includes 41U graphite storage cabinet, six M5214 dual-redundant FC loop
14-bay drive enclosures, 12 16.4-feet/5-meter interconnect cables (to 2C12D-B); requires
DS-KGPSA-xx (283264-B22) |
DS-SV110-MB |
|
Enterprise Virtual Array Model
0C12D-B 60-Hz, includes 41U graphite storage cabinet, 12 M5214 dual-redundant FC loop
14-bay drive enclosures, 24 16.4-feet/5-meter interconnect cables (to two 2C12D-Bs);
requires DS-KGPSA-xx (283265-B21) |
DS-SV110-NA |
|
Enterprise Virtual Array Model
0C12D-B 50-Hz, includes 41U graphite storage cabinet, 12 M5214 dual-redundant FC loop
14-bay drive enclosures, 24 16.4-feet/5-meter interconnect cables (to two 2C12D-Bs);
requires DS-KGPSA-xx (283265-B22) |
DS-SV110-NB |
| |
| SAN Solutions Kits |
Tru64 UNIX SAN Solutions Kit for
Enterprise Virtual Array V2.0 (250193-B22)
NOTE: V5.1 requires Patch Kit 3:
T64V51B19AS0005-20020411.tarV5.1A requires Patch Kit 3: T64V51AB03AS0003-20020827.tar. |
QB-6RPAB-SB |
|
OpenVMS SAN Solutions Kit for
Enterprise Virtual Array V2.0 (250194-B22)
NOTE: V7.2-2 requires Tima Kit:
DEC-AXPVMS-VMS722_FIBRE_SCSI-V0200V7.3 requires Tima Kit:
DEC-AXPVMS-VMS73_FIBRE_scsi-V0300. |
QB-6RPAC-SB |
| |
|
|
| Fibre Channel Controller |
Fibre Channel Controller (HSG80),
includes 256-MB cache, requires the following firmware: 8.6-4F ACS FW (222318-B22,
QB-6BUAA-SD), one per controller
8.6-4S ACS FW (222364-B22, QB-6ENAA-SC), one per controller
8.6-4P ACS FW (222316-B22, QB-6CAAA-SD), one per controller
Requires Tru64 UNIX software: 222320-B23, QB-65RAB-SE, one per controller
Requires OpenVMS software: 222321-B22, QB-65RAC-SD, one per controller |
DS-HSG80-BK |
|
Additional 256-MB cache for HSG80
(380674-B21) |
DS-HSDIM-AC |
|
Single cache battery, one per
HSG80 controller (135823-B21) |
DS-SE2CS-CB |
|
Model 2200 controller shelf for
HSG80 controller (DS-SE2ZS-C8) |
135820-B21 |
| |
|
|
| StorageWorks Disk Array Family |
NOTE: The
HP StorageWorks Disk Array Family, specifically the XP128 and XP1024, are now supported on
AlphaServer ES45 systems. For product and ordering information, refer to the following Web
pages:
http://www.hp.com/products1/storage/
products/disk_arrays/
highend/xp1024/index.html
http://www.hp.com/products1/storage/
products/disk_arrays/
highend/xp128/index.html The following part numbers have been assigned for
reference purposes only: |
|
|
3R-A4417-AA |
A7876A |
XP128 Disk Array Control Frame |
|
|
3R-A4418-AA |
A7906A |
XP1024 Disk Array Control Frame |
|
|
|
|
| Step
11d Fibre Channel Options |
|
The following disk drives, hubs,
data routers, switches, and cables are used in Fibre Channel configurations using the
DS-KGPSA-xx adapter. |
|
| |
|
|
| Fibre Channel Disk
Drives |
36-GB 10K rpm dual-port 2-Gb/sec
FC-AL 1-inch (2.54 cm) drive (238590-B21) |
3R-A3239-AA |
|
36-GB 15K rpm dual-port 2-Gb/sec
FC-AL 1-inch (2.54 cm) drive (236205-B21) |
3R-A3210-AA |
|
72-GB 10K rpm dual-port 2-Gb/sec
FC-AL 1-inch (2.54 cm) drive (238921-B21) |
3R-A3260-AA |
| |
|
|
| Fibre Channel Hubs |
Fibre Channel 7-port Storage Hub,
International (Tru64 UNIX only) (234453-B31) |
DS-SWXHB-17 |
|
Fibre Channel 7-port Storage Hub,
Japan (Tru64 UNIX only) (234453-291) |
DS-SWXHB-J7 |
| |
|
|
| Fibre Channel Data
Routers |
1 Fibre Channel x 2 HVD data
router (163082-B21) |
3R-A2673-AA |
|
1 Fibre Channel x 2 LVD data
router (163083-B21) |
3R-A2774-AA |
|
2 x 4 LVD Fiber Channel to SCSI
Network Storage Router (262653-B21) |
3R-A3740-AA |
|
2 x 4 HVD Fiber Channel to SCSI
Network Storage Router (262654-B21) |
3R-A3741-AA |
| |
| Fibre Channel Switches |
Fibre Channel 2-Gb
8-port SAN switch (258707-B21) |
DS-DSGGD-AC |
|
Fibre Channel 2-Gb
16-port SAN switch (283056-B21) |
DS-DSGGD-AD |
|
Fibre Channel 2-Gb
SAN switch 16-port; requires Tru64 UNIX V5.1A Patch Kit:
T64V51AB01AS0001-20020116.tar (287055-B21) |
DS-DSGGD-BA
|
|
Fibre Channel 2-Gb
64-port Core Switch (254508-B21) |
DS-DSGGE-AB |
| |
|
|
| McData 64-port
Fibre Channel SAN Director Class Switches |
SAN Director 64 (1
GB) 32 ports, base model |
DS-DMGGD-AA |
| SAN Edge Switch 2 Gb,
32 ports |
DS-DMGGE-BC |
| SAN Edge Switch 2 Gb,
16-ports |
DS-DMGGE-BB |
|
NOTE:
Connection for, or between, 1-Gb and/or 2-Gb SAN switches requires different cables. Refer
to the Switches, Hubs, and Interconnects QuickSpecs at: http://www.compaq.com/products/quickspecs/
North_America/10490.html |
|
| |
|
|
| Fibre Channel Cables |
NOTE:
The following LC-SC connector cables support connectivity between 1-Gb and 2-Gb devices. |
|
|
2-meter
LC-SC multi-mode Fibre Channel cable (221691-B21) |
3R-A2976-AA |
|
5-meter LC-SC
multi-mode Fibre Channel cable (221691-B22) |
3R-A2977-AA |
|
15-meter LC-SC
multi-mode Fibre Channel cable (221691-B23) |
3R-A2978-AA |
|
30-meter LC-SC
multi-mode Fibre Channel cable (221691-B26) |
3R-A3458-AA |
|
50-meter LC-SC
multi-mode Fibre Channel cable (221691-B27) |
3R-A3459-AA |
|
NOTE:
The following LC-LC connector cables support connectivity between 2-Gb and 2-Gb devices. |
|
|
2-meter LC-LC
multi-mode Fibre Channel cable (221692-B21) |
3R-A2979-AA |
|
5-meter LC-LC
multi-mode Fibre Channel cable (221692-B22) |
3R-A2980-AA |
|
15-meter LC-LC
multi-mode Fibre Channel cable (221692-B23) |
3R-A2981-AA |
|
30-meter LC-LC
multi-mode Fibre Channel cable (221692-B26) |
3R-A3454-AA |
|
50-meter LC-LC
multi-mode Fibre Channel cable (221692-B27) |
3R-A3455-AA |
| |
| Step 12 - Graphics Adapters - Optional |
- Select graphics adapter, monitor, and country-specific keyboard for Tru64 UNIX and
OpenVMS systems if required
|
|
| |
Maximum
# Supported |
|
| |
Tru64 UNIX |
OpenVMS |
PCI/AGP
Slot |
|
| 2D Graphics |
3Dlabs Oxygen VX1 32-MB PCI 2D
graphics accelerator; can operate in all slots; for best performance, use 66-MHz slots.
Linux-supported option; maximum
one per systemNOTE: Only VX1 cards may be used in a multi-head environment. |
4 |
4 |
3.3/5 V |
66 MHz |
SN-PBXGF-AB |
| 3Dlabs Oxygen VX1 32-MB AGP 2D
graphics accelerator; AGP can only operate in Model 1B or Model 1 in slot 3; requires
Tru64 UNIX V5.1A with NHD-4; requires OpenVMS V7.3-1; no TruCluster support. NOTE: Only VX1 cards may be used in a
multi-head environment. |
4 (1 AGP3 PCI) |
4 (1 AGP3 PCI) |
1.5 V |
4X |
SN-PBXGF-BC |
| PCI 32-bit, 33-MHz multi-function
(single-port 10/100 Ethernet UTP/RJ45, Ultra2 LVD SCSI, and 2D graphics) adapter. Model 1
or 1B requires installation on PCI Bus 0 in slots 1 or 2; Model 2 or 2B 1B requires
installation on PCI Bus 0 in slots 3, 6, 9, or 10. NOTE: Tru64 UNIX V5.1A requires Patch Kit 3:
T64V51AS0003-20010413.tar
Only one 3X-KZPEA-DB allowed on same PCI bus; no multi-head graphics support; TruCluster
support restricted to non-shared SCSI buses only.
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45
cables . |
1 |
1 |
5V |
33MHz |
3X-DEPVZ-AA |
| 3D Graphics |
PowerStorm 300 3D multi-head
graphics accelerator with 15-MB frame buffer memory and 16-MB texture memory; use in slots
3, 6, 9, or 10. NOTES: Only
PowerStorm cards may be used in a multi-head environment.
3X-KZPEA-DB adapter requires 54-25563-01 be at minimum
Rev C06 when installing
3X-KZPEA-DB on same PCI bus. |
4 |
4 |
5 V |
33 MHz |
SN-PBXGD-AD |
| |
PowerStorm 350 3D multi-head
graphics accelerator with 30-MB frame buffer memory and 32-MB texture memory; use in slots
3, 6, 9, or 10. NOTES: Only
PowerStorm cards may be used in a multi-head environment.
3X-KZPEA-DB adapter requires 54-25563-01 be at minimum
Rev B05, or 54-25563-02 be at minimum Rev A03, when installing
3X-KZPEA-DB on same PCI bus. |
4 |
4 |
5 V |
33 MHz |
SN-PBXGD-AE |
| |
| Step 13- Monitors - Optional |
- Graphics monitors other than those listed can be used if compatible with SVGA graphics
ordered with system.
|
|
- A video cable, 6-foot/1.8-meter length, is included with all variants of monitors.
|
|
- Video extension cable required if monitor is located more than 1.5-meter from system.
|
|
- Monitors will ship with, but not be integrated with systems.
|
|
| Carbon/Silver
Monitors |
V7550 17-inch
(16-inch viewable image size) flat-faced shadow mask color monitor, two-tone
(carbon/silver), 0.25mm dot pitch, VGA to 1024 x 768 @85 Hz, MPRII/TCO 99/Energy Star
Compliant, Northern Hemisphere with NA power cord, VGA cable |
3R-A4002-AA |
|
Same as above, with Euro power
cord |
3R-A4201-AA |
|
Same as above, APD, no power cord |
3R-A4202-AA |
|
Same as above, with PRC power
cord, CCIB |
3R-A4446-AA |
|
Same as above, Southern
Hemisphere, with Australia/New Zealand power cord |
3R-A4203-AA |
| |
|
|
|
P930 19-inch (18-inch viewable
image size) auto-scanning color monitor, Diamondtron NF, 0.24-mm aperture grille pitch,
VGA to 1600 x 1200 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA
power cord, VGA cable |
3R-A4215-AA |
|
Same as above, with Euro power
cord |
3R-A4391-AA |
|
Same as above, Taiwan, with NA
power cord |
3R-A4392-AA |
|
Same as above, with PRC power
cord, CCIB |
3R-A4394-AA |
|
Same as above, Southern
Hemisphere, 0.25 to 0.27 mm aperture grille pitch, with Australia/New Zealand power cord |
3R-A4393-AA
|
| |
|
|
|
P1130 21-inch (19.8inch
viewable image size) FD Trinitron auto-scanning color monitor, 0.24-mm aperture grille
pitch, VGA to 1792 x 1344 @85Hz, dual video input, USB Hub, MPRII/TCO 99/Energy Star
Compliant, Northern Hemisphere with NA power cord, VGA cable |
3R-A4216-AA
|
|
Same as above, with Euro power
cord |
3R-A4396-AA |
|
Same as above, Taiwan, with NA
power cord |
3R-A4397-AA |
|
Same as above, with PRC power
cord, CCIB |
3R-A4400-AA |
|
Same as above, Southern
Hemisphere, with Australia/New Zealand power cord |
3R-A4398-AA |
| |
|
|
| Carbon/Silver Flat Panel
Monitors |
TFT1825, 18-inch (18-inch
viewable image size) TFT flat panel monitor, 0.28mm pixel pitch, 1600 x 1200 @60Hz,
multi-mode support, MPRII/TCO99/Energy Star compliant, one VGA, one DVI-I input connector,
NA power cord, VGA, and DVI-I cables |
3R-A4292-AA
|
|
TFT1520, 15-inch (15-inch
viewable image size) TFT flat panel monitor, 0.297 mm pixel pitch, 1024 x 768 @75 Hz,
multi-mode support, MPRII/TCO99/Energy Star compliant, two video input connectors (one VGA
and one DVI-I), NA power cord, VGA and DVI-I cables |
3R-A4249-AA |
| |
|
| Video Extension Cable |
6-foot/1.8-meter video extension
cable |
BN39C-02 |
| |
|
|
| Monitor Power Cords |
North America |
BN26J-1K |
|
Australia, New Zealand, 2.5-meter
(103541-011) |
BN19H-2E |
|
Central Europe, 2.5-meter |
BN19C-2E |
|
Denmark, 2.5-meter (103541-481) |
BN19K-2) |
|
Egypt, India, South Africa,
2.5-meter (103541-AR1) |
BN19S-2E |
|
Israel, 2.5-meter |
BN18L-2E |
|
Italy, 2.5-meter (103541-461) |
BN35M-02 |
|
Japan, 2.5-meter, Dentori
approved |
3X-BN46F-02 |
|
Republic of China (103541-001) |
BN19H-2E |
|
Switzerland, 2.5-meter
(103541-511) |
BN19E-2E |
|
UK, Ireland, 2.5-meter |
BN19A-2E |
| |
| Step 14 - Keyboards, Mouse, and Documentation Optional |
| Step
14a - Keyboards |
- Select country-specific keyboard or mouse only if required
- All keyboards listed may not be available in all geographies
- Select an opal OpenVMS keyboard for use with VT5xx text terminals
|
| |
Opal
(for VT5xx) |
Carbon |
| Keyboard/Language |
OpenVMS |
Tru64
UNIX/Linux |
OpenVMS |
| U.S./English keyboard |
LK461-A2 |
3R-LKQ48-BA |
3X-LK462-A2 |
| Arabic keyboard |
- |
3R-LKQ48-BR |
- |
| Belgian keyboard |
LK461-AB |
3R-LKQ48-AB |
3X-LK462-AB |
| BHCSY keyboard |
- |
3R-LKQ48-AX |
- |
| Canadian/English
keyboard |
LK461-AQ |
- |
3X-LK462-AQ |
| Canadian/French
keyboard |
LK461-AC |
3R-LKQ48-AC |
3X-LK462-AC |
| Cyrillic keyboard
(Russian) |
LK461-BT |
3R-LKQ48-BT |
3X-LK462-BT |
| Czech keyboard |
LK461-BV |
3R-LKQ48-BV |
3X-LK462-BV |
| Danish keyboard |
LK461-AD |
3R-LKQ48-AD |
3X-LK462-AD |
| Dutch keyboard |
LK461-AH |
3R-LKQ48-AH |
3X-LK462-AH |
| Finnish keyboard |
LK461-AF |
3R-LKQ48-AF |
3X-LK462-AF |
| French keyboard |
LK461-AP |
3R-LKQ48-AP |
3X-LK462-AP |
| German keyboard |
LK461-AG |
3R-LKQ48-AG |
3X-LK462-AG |
| Greek keyboard |
LK461-BH |
3R-LKQ48-BH |
3X-LK462-BH |
| Hebrew keyboard |
LK461-AT |
3R-LKQ48-AT |
3X-LK462-AT |
| Hungarian keyboard |
LK461-BQ |
3R-LKQ48-BQ |
3X-LK462-BQ |
| International
keyboard |
- |
3R-LKQ48-BA |
- |
| Italian keyboard |
LK461-AI |
3R-LKQ48-AI |
3X-LK462-AI |
| Japanese keyboard |
- |
3R-LKQ48-AJ |
- |
| Korean keyboard |
- |
3R-LKQ48-BK |
- |
| Latin-American
keyboard |
- |
3R-LKQ48-AR |
- |
| Norwegian keyboard |
LK461-AN |
3R-LKQ48-AN |
3X-LK462-AN |
| Polish keyboard |
LK461-BP |
3R-LKQ48-BP |
3X-LK462-BP |
| Portuguese keyboard |
LK461-AV |
3R-LKQ48-AV |
3X-LK462-AV |
| Romanian keyboard |
LK461-BL |
- |
3X-LK462-BL |
| Simplified Chinese
keyboard |
- |
3R-LKQ48-CV |
- |
| Slovak keyboard |
LK461-CZ |
3R-LKQ48-CZ |
3X-LK462-CZ |
| Spanish keyboard |
LK461-AS |
3R-LKQ48-AS |
3X-LK462-AS |
| Swedish keyboard |
LK461-AM |
3R-LKQ48-AM |
3X-LK462-AM |
| Swiss/French keyboard |
LK461-AK |
3R-LKQ48-AK |
3X-LK462-AK |
| Swiss/German keyboard |
LK461-AL |
- |
3X-LK462-AL |
| Traditional Chinese
keyboard |
- |
3R-LKQ48-BI |
- |
| Thai keyboard |
- |
3R-LKQ48-CB |
- |
| Turkish Q keyboard |
LK461-BU |
3R-LKQ48-BU |
3X-LK462-BU |
| Turkish/F keyboard |
LK461-BW |
- |
3X-LK462-BW |
| UK keyboard |
- |
3R-LKQ48-AE |
- |
| Yugoslavian keyboard |
LK461-BY |
- |
3X-LK462-BY |
| |
| Step 14b - Mouse |
| Mouse |
3-button
mouse carbon |
3R-A3480-AA |
| |
| Keyboard
or Mouse Extension Cable |
6-foot/1.8-meter
keyboard or mouse extension cable to extend both keyboard and mouse order two
cables |
3X-BC34A-06 |
| |
| Step 14c - Documentation |
| Documentation |
Additional ES45
System Information Kit (includes Owners Guide, print and CD) |
QA-6NUAB-G8 |
| |
| Step 15 - Console Terminal - Optional |
|
- Any terminal can be used as a console device
|
|
|
- Third-party console devices require an EIA-232 25-pin DSUB connector
|
|
|
VT510
video terminal; requires keyboard, H8575-x adapter, and BC16E-x cable |
VT510-xx |
|
Console cable, female
connector (25-pin passive adapter) |
H8575-A |
|
Console cable, male
connector (adapter with EOS, ESD, 25 POS D-SUB) |
H8575-D |
| |
| Step 16 - Software - Media and documentation required for first system on
site |
- Software Processor Code = E
|
|
| Tru64 UNIX |
- AlphaServer ES45 Tru64 UNIX systems include Unlimited User license, Server Extension
license, Internet Express, and Secure Web Server
|
|
| |
|
|
| When using Tru64
UNIX V5.1A |
Tru64 UNIX media and
online documentation on CD-ROM |
QA-6ADAA-H8 |
| Tru64 UNIX full hard
copy documentation |
QA-6ADAA-GZ |
|
TruCluster Plus
Software Package, licenses for TruCluster Server, Logical Storage Manager and AdvFS
Utilities |
QP-6R9AE-AA |
|
TruCluster Server
License |
QL-6BRAE-AA |
|
Logical Storage
Manager License |
QL-2GVAE-AA |
|
AdvFS Utilities
License |
QL-0EGAE-AA |
|
Advanced Server for
Tru64 UNIX, 25 client concurrent use license |
QL-5U29M-3D |
|
Advanced Server for
Tru64 UNIX, 50 client concurrent use license |
QL-5U29M-3E |
|
Advanced Server for
Tru64 UNIX, 100 client concurrent use license |
QL-5U29M-3F |
|
Advanced Server for
Tru64 UNIX, 250 client concurrent use license |
QL-5U29M-3G |
|
Advanced Server for
Tru64 UNIX, 500 client concurrent use license |
QL-5U29M-3H |
|
Layered products
media and documentation for Tru64 UNIX on CD-ROM |
QA-054AA-H8 |
|
DECnet/OSI extended
function license for Tru64 UNIX |
QL-MTKAE-AA |
|
DECnet/OSI end-system
license for Tru64 UNIX |
QL-MTJAE-AA |
|
Open3D for Tru64 UNIX
on CD-ROM, includes graphics drivers |
QA-OAFAA-H8 |
| OpenVMS |
- AlphaServer ES45 OpenVMS systems include Base license with System Manager license and
Enterprise Integration Server License Package for OpenVMS Revision V3.1
|
|
|
- AlphaStation ES45 OpenVMS systems include pre-installed software, Base license,
Concurrent Use 1-user license, NAS 150 Client license, MMS RT license and Open3D
traditional license
|
|
|
- Enterprise Integration Package includes licenses for TCP/IP Services for OpenVMS,
DECwindows Motif for OpenVMS Alpha, DECprint Supervisor for OpenVMS Alpha Plus, DECprint
Supervisor for OpenVMS Open, DECnet-Plus for OpenVMS Alpha End System, Archive/Backup
System for OpenVMS Management Tools, Archive/Backup Agent for Windows NT, OpenVMS Disk
Services for Windows NT, Office Server for OpenVMS, PATHWORKS 32, PATHWORKS V6 for OpenVMS
Advanced Server, and DIGITAL Office Server Client Access License
|
|
|
- OpenVMS Concurrent Use licenses provide the right to interactively use the operating
system by the specified number of concurrent users on a designated OpenVMS system. OpenVMS
Concurrent Use licenses can be moved from one system to another at user discretion and can
be shared in a mixed OpenVMS VAX and OpenVMS Alpha cluster.
|
|
|
- OpenVMS Traditional Unlimited Use license is system specific and can only be used on one
system at a time. It cannot be shared between systems or in an OpenVMS VAX or OpenVMS
Alpha Cluster.
|
|
|
Concurrent Use 1-user
license |
QL-MT3AA-3B |
|
Concurrent Use 2-user
license |
QL-MT3AA-3C |
|
Concurrent Use 4-user
license |
QL-MT3AA-3D |
|
Concurrent Use 8-user
license |
QL-MT3AA-3E |
|
Concurrent Use
16-user license |
QL-MT3AA-3F |
|
Concurrent Use
32-user license |
QL-MT3AA-3G |
|
Concurrent Use
64-user license |
QL-MT3AA-3H |
|
Concurrent Use
128-user license |
QL-MT3AA-3J |
|
Concurrent Use
256-user license |
QL-MT3AA-3K |
|
Traditional unlimited
user license |
QL-MT2AE-AA |
|
OpenVMS media and
documentation on CD-ROM |
QA-MT1AA-H8 |
|
OpenVMS full hard
copy documentation |
QA-001AA-GZ |
|
Layered products
media and documentation for OpenVMS on CD-ROM, includes Enterprise Integration Server for
OpenVMS media and documentation. |
QA-03XAA-H8 |
|
DECnet extended
function license for OpenVMS |
QL-MTGAE-AA |
|
DECnet end-system to
extended function upgrade license for OpenVMS |
QL-MTHAE-AA |
|
OpenVMS Cluster
license for Alpha systems |
QL-MUZAE-AA |
|
OpenVMS Volume
Shadowing license |
QL-2A1AE-AA |
| |
| Step 17 - Hardware and Software Supplemental Support Services for Tru64 UNIX
and OpenVMS - Optional |
- Select one of the optional CarePaq Priority Service Packages described below that best
supports the customers operational requirements for system availability.
|
|
| |
|
|
| CarePaq Priority Services |
- CarePaq Priority Services are available for AlphaServer systems running Tru64 UNIX or
OpenVMS operating system. Priority Services are designed for the growing number of
customers who need support beyond the basic warranty. It offers six service packages
Warranty Plus, Priority, Priority 24, Priority Silver, Priority Gold, and Priority
Executive with coverage for both Principal servers systems and SSPs (Subsequent System
Packages) - that meet a full range of customer support requirements.
|
|
| |
|
|
| Program Features
Principal Server |
|
| Warranty Plus |
|
|
|
- Next Business Day on-site hardware support
|
|
|
- 2-hour response for Bronze software support
|
|
|
- License Subscription for HP O/S software and embedded L/P (unlimited users and server
extensions for Tru64 UNIX)
|
|
| |
|
|
| Priority |
|
|
|
- 4-hour response on-site hardware support
|
|
|
- 2-hour response for Bronze software support
|
|
|
- License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
|
|
- Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their
layered products. (Some layered products on Consolidated Media Update Distribution can be
ordered separately.)
|
|
| |
|
|
| Priority 24 |
|
|
|
|
|
|
- 4-hour response on-site hardware support
|
|
|
- 2-hour response for Bronze software support
|
|
|
- License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users and server extensions for Tru64 UNIX)
|
|
|
- Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their
layered products. (Some layered products on Consolidated Media Update Distribution can be
ordered separately.)
|
|
| |
|
|
| Priority Silver |
- 24 x 7 HW Support. Named Engineer, 4-hour response
|
|
|
- 24 x 7 Silver SW Support - Named Account Rep, 1-hour response Monday Friday,
8AM-5PM local time; 2-hour response remaining hours
|
|
|
- License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
|
|
- Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their
layered products. (Some layered products on Consolidated Media Update Distribution can be
ordered separately.)
|
|
|
- Technical newsletter and SW activity review
|
|
|
- Proactive Patch Notification
|
|
|
- One System Healthcheck per year
|
|
| |
|
|
| Priority Gold |
- 24 x 7 HW support with Named Engineer, 4-hour response for on-site support
|
|
- 24 x 7 Gold SW support - Named Account Rep
|
|
|
- 30-minute callback (critical); 1-hour callback (non-critical)
|
|
|
- License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
|
|
- Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their
layered products. (Some layered products on Consolidated Media Update Distribution can be
ordered separately.)
|
|
|
- Technical newsletter, SW activity review and 10 hrs Upgrade impact planning
|
|
|
- Proactive Revision Management
|
|
|
- Two System Healthchecks per year
|
|
|
- Mandatory pre-qualification required
|
|
| |
|
|
| Priority Gold Executive |
- 24 x 7 HW support with Named Engineer, 2-hour response for on-site support
|
|
|
- 24 x 7 Gold SW support - Named Account Rep
|
|
|
- 30-minute callback (critical); 1-hour callback (non-critical)
|
|
|
- License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
|
|
- Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their
layered products. (Some layered products on Consolidated Media Update Distribution can be
ordered separately.)
|
|
|
- Technical newsletter, SW activity review and 10 hrs Upgrade impact planning
|
|
|
- Proactive Revision Management
|
|
|
- Two System Healthchecks per year
|
|
|
- Customer site must be within 25 miles of a HP service location
|
|
|
- Mandatory pre-qualification required
|
|
| |
|
|
| Program Features
Additional Services |
|
SSPs
(Subsequent System Packages) |
- For Priority, Priority 24, Priority Silver, Priority Gold, and Priority Gold Executive
|
|
|
- HW Support at same level as corresponding package for Principal server
|
|
|
- License Subscription: HP O/S (where applicable)
|
|
|
- Telephone support through Principal server covered by full support package
|
|
| |
|
|
| Installation |
|
|
|
|
|
|
|
|
|
|
|
|
- No software installation added
|
|
| |
|
|
| Installation &
Startup HP O/S |
|
|
|
|
|
|
|
|
|
|
|
|
- Install operating systems
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
Model/CarePaq
Priority Service |
Principal Server
1 year |
Principal Server
3 years |
Subsequent Systems
1 year |
Subsequent Systems
3 years |
| AlphaServer
ES45 Model 2 |
|
|
| Warranty Plus |
Not available |
FP-F00EB-36 |
Not available |
Not available |
| Priority |
FP-F01EB-12 |
FP-F01EB-36 |
FP-F21EB-12 |
FP-F21EB-36 |
| Priority 24 |
FP-F02EB-12 |
FP-F02EB-36 |
FP-F22EB-12 |
FP-F22EB-36 |
| Priority Silver |
FP-F04EB-12 |
FP-F04EB-36 |
FP-F24EB-12 |
FP-F24EB-36 |
| Priority Gold |
FP-F08EB-12 |
FP-F08EB-36 |
FP-F28EB-12 |
FP-F28EB-36 |
| Priority Gold
Executive |
FP-F09EB-12 |
FP-F09EB-36 |
FP-F29EB-12 |
FP-F29EB-36 |
| Installation |
FP-FINST-EB |
FP-FINST-EB |
FP-FINST-EB |
FP-FINST-EB |
| Installation &
Startup |
FP-FSTAR-EB |
FP-FSTAR-EB |
FP-FSTAR-EB |
FP-FSTAR-EB |
| |
NOTES:
- AlphaServer ES45 systems include one-year parts and labor warranty with 5x9, on-site
Next Business Day response.
- Priority Services include support for new HP branded hardware options internal to the
AlphaServer enclosure plus a monitor (17-inch or less excluding flat panel models).
- External storage devices/cabinets carry their own level of warranty and should be quoted
separately for uplifted warranty services.
- Five-year CarePaq Priority Service is available upon request. To quote five-year
service, change the last two part number digits from 12 or 36 to 60.
- In addition to the CarePaq Priority Services, uplifted warranty Supplemental Services
are available for separate hardware and software support. For more information on Hardware
and Software Supplemental Services and other HP service options available for
AlphaServers, please consult your Sales Account Manager or visit:
http://www.hp.com/hps/
NOTE: This website is available in English only. |
| |
| Step
18 - Hardware Supplemental Support Services for Linux - Optional |
| Hardware - Americas
and Asia Pacific Only |
- Systems include three-year hardware warranty, onsite with 5 x 9, 24-hour response time
|
|
- Options ordered as part of initial system sale take on warranty of the enclosure
|
|
- Options added after initial system sale take on warranty of the enclosure until
enclosure warranty ends
|
|
- All unique ES45 options have a minimum of one-year Return to Hewlett-Packard Warranty
|
|
- Select optional Hardware Supplemental Support Services if required
|
|
Supplemental
Service for ES45 Tower System |
Model 1 |
Model 2 |
|
3-year, 5 x 9, 4-hour
response time |
FM-4T4HR-36 |
FM-4Q4HR-36 |
|
5-year, 5 x 9, 4-hour
response time |
FM-4T4HR-60 |
FM-4Q4HR-60 |
|
3-year, 7 x 24, 4-hour
response time |
FM-4T724-36 |
FM-4Q724-36 |
|
5-year, 7 x 24, 4-hour
response time |
FM-4T724-60 |
FM-4Q724-60 |
|
5-year, 5 x 9, next
day, on-site |
FM-4TXHW-60 |
FM-4QXHW-60 |
|
Supplemental
Service for ES45 Pedestal System |
Model 1 |
Model 2 |
|
3-year, 5 x 9, 4-hour
response time |
FM-4F4HR-36 |
FM-4G4HR-36 |
|
5-year, 5 x 9, 4-hour
response time |
FM-4F4HR-60 |
FM-4G4HR-60 |
|
3-year, 7 x 24, 4-hour
response time |
FM-4F724-36 |
FM-4G724-36 |
|
5-year, 7 x 24, 4-hour
response time |
FM-4F724-60 |
FM-4G724-60 |
|
5-year, 5 X 9, next
day, on-site |
FM-4FXHW-60 |
FM-4GXHW-60 |
|
Installation
Services |
Model 1 |
Model 2 |
|
Hardware product
installation for ES45 Tower System |
FM-4TINS-IN |
FM-4QINS-IN |
|
Hardware product
installation for ES45 Pedestal System |
FM-4FINS-IN |
FM-4GINS-IN |
| |
|
Add-on
memory installation for ES45 |
FM-64MEM-IN |
| Add-on SMP
CPU installation for ES45 |
FM-64CPU-IN |
|
NOTE: Add-on installation part numbers should be used when options
are added to existing systems. |
|
| |
|
|
| HardwareEurope
Only |
Europe
does not offer specific part numbers for Hardware Supplemental Support Services. Prices
are quoted based on worldwide service reference pricing. Contact MCS Sales in your country
for information on Hardware Supplemental Support Services. |
|
|