contents
 Overview   Standard Features   Systems/Options   Options   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) QuickSpecs

Compaq AlphaServer DS10
Compaq AlphaStation DS10

spacerw.gif (802 bytes)

10908_OV.jpg (224569 bytes)

spacerw.gif (802 bytes)
At A Glance

AlphaServer™/AlphaStation™ DS10 3U Systems include:

  • Alpha 600-MHz CPU with 2-MB onboard ECC cache
  • 256-MB, 512-MB, or 1-GB SDRAM memory - expandable to 2-GB maximum memory capacity
  • Onboard dual 10/100 BaseT Ethernet ports
  • Four PCI expansion slots - three 64-bit PCI slots and one 32-bit PCI slot
  • Onboard dual IDE controller
  • 1.44-MB diskette drive
  • 600-MB CD-ROM drive
  • Two storage cage subsystems: Internal Storage Cage for IDE/SCSI tapes/drives; Front Access Storage Cage for SCSI drives
  • DS10 Internal Storage Cage Systems can be configured with: three internal 3.5-inch x 1-inch hard disk drives or two internal 3.5-inch x 1-inch hard disk drives and one 5.25-inch x 1.6-inch removable media device
  • DS10 Front Access Storage Cage Systems can be configured with: two front access 3.5-inch x 1-inch hard disk drives and two internal 3.5-inch x 1-inch hard disk drives) or one Front Access Universal tape drive (AIT or DAT) and two internal disk drives
  • Maximum Internal storage capacity: Internal Storage Cage-108-GB SCSI or 120-GB IDE; Front Access Storage Cage-
    364-GB SCSI
  • Two serial ports: COM1 port is both an RMC port with modem control and a full-duplex asynchronous communications port; COM2 port is a full-duplex asynchronous communications port
  • Bi-directional enhanced parallel port
  • PS/2-style keyboard port and mouse port
  • 300W (120/240V, 60/50 Hz) power supply
  • U.S. English documentation
  • Tru64?/font> UNIX™ or OpenVMS™ Factory Installed Software
  • 90-day software product warranty
  • Protected by HP Services, including three-year, on-site hardware with next business day response

NOTE: Keyboard, power cord, and mouse must be ordered separately.

contents
 Overview   Standard Features   Systems/Options   Options   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) Standard Features
Processor Alpha 21264A 600-MHz processor
    
Cache Memory 2-MB onboard cache
   
Upgradability Supports upgrades of memory and hard drives
Standard One CPU
  
Memory Standard 256 MB, 512 MB, or 1 GB (one memory kit) - Tru64 UNIX, OpenVMS;
512 MB or 1 GB - Linux-Ready
Maximum 2 GB (two memory kits, kits include two industry-standard DIMMs with
ECC support)
   
Network Controller Onboard dual 10/100 BaseT Ethernet ports
    
Expansion Storage bays Internal Storage Cage Systems: Five total – CD-ROM, FDD, and three storage bays: Three internal 3.5-inch x 1-inch hard disk drives or two internal 3.5-inch x 1-inch hard disk drives and one 5.25-inch x 1.6-inch removable media device
Front Access Storage Cage Systems: Six Total – CD-ROM, FDD, and Four Storage bays (two front access 3.5-inch x 1-inch hard disk drives and two internal
3.5-inch x 1-inch hard disk drives)
PCI slots Four full-length slots (three 64-bit, one 32-bit)
  
Storage Diskette Drive 1.44-MB diskette drive
CD-ROM Internal Storage Cage Systems: 5.25-inch half height 40X CD-ROM drive
Front Access Storage Cage Systems 24X slim-line CD-ROM drive
Hard Drives 20-GB and 40-GB IDE disk drives or 18.2-GB and 36.4-GB Wide Ultra3 available with the Internal Storage Cage, and 18.2-GB, 36.4-GB, 72.8-GB or 146-GB Universal SCSI drives available with Front Access Storage Cage. SCSI disk drives require optional SCSI adapter. IDE drives not supported in Front Access Cage systems.
  
Storage Adapter/Controller Onboard IDE controller for internal storage, choice of optional storage adapters/controllers
    
Expansion Ports Parallel One bi-directional enhanced port
Serial Two ports, one serial port with full-duplex asynchronous modem control and one RMS dedicated serial port with full-duplex asynchronous modem control
Keyboard One PS/2-style port
Mouse One port
  
Power Supply 300W (88-260V, 47-63 Hz)
 
Manageability Compaq Insight Manager™
   
Supported Options A detailed summary of options supported on the AlphaServer/AlphaStation DS10 is available at http://www.compaq.com/alphaserver/options/asds10/
asds10_options.html

NOTE: This website is available in English only.
  
OS Support AlphaServer DS10 Tru64 UNIX systems include pre-installed software (V5.1A), Base license, Unlimited User license, Server Extension license, Internet Express, and Compaq Secure Web Server.
AlphaStation DS10 Tru64 UNIX systems include pre-installed software (V5.1A), 2-user Base license
AlphaServer DS10 OpenVMS systems include pre-installed software (V7.3), Base license with System Manager license and Enterprise Integration Server License Package for OpenVMS V3.0A.
AlphaStation DS10 OpenVMS systems include pre-installed software (V7.3), Base license, Concurrent Use 1-user license, and NAS 150 Client license.
Minimum OS support: Tru64 UNIX V4.0F or OpenVMS V7.1 –2
   
Service and Support Protected by HP Services, including a three-year, on-site hardware warranty with next business day response. Software warranty is a 90-day telephone advisory. Training, consulting, network integration, software support, comprehensive system maintenance and guaranteed uptime services are also available for customers requiring higher levels of service and support.
contents
 Overview   Standard Features   Systems/Options   Options   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) Systems/Options
Step 1 - Select system
AlphaServer/AlphaStation DS10 600-MHz systems require the mandatory selection of the following items:
  • One Storage Cage (either Internal Storage Cage or Front Access Storage Cage) and one system disk
  • If Internal Storage Cage is selected:
  • Mandatory selection of one IDE or one internal SCSI system disk drive
  • Mandatory selection of SCSI adapter and SCSI cable kit required for internal SCSI disks and tape
  • If Front Access Storage Cage is selected:
  • Mandatory selection of one Universal SCSI system disk drive
  • Mandatory selection of SCSI adapter is required for Front Access Storage Cage (cable is included)
  • Front Access Storage Cage based system is SCSI only. (IDE drives cannot be used.)
  • Country-specific power cord
  • Software media and documentation for first system on site
  • Rackmount kit for rackmount systems (See Step 5 – M-Series Cabinet Enclosures)
  • Minimum OS support: Tru64 UNIX V4.0F or OpenVMS V7.1-2
NOTE: Country-specific keyboard and mouse are recommended. See Step 11.
  
AlphaServer DS10 600-MHz Base Systems
OS CPU Memory PCI 2-10/100t Ports Hard Drive Storage Cage Order No.
Tru64 UNIX 600 MHz 256 MB 4 Onboard Mandatory Mandatory DA-74BAA-DA
Tru64 UNIX 600 MHz 512 MB 4 Onboard Mandatory Mandatory DA-74BAA-EA
Tru64 UNIX 600 MHz 1 GB 4 Onboard Mandatory Mandatory DA-74BAA-FA
               
OpenVMS 600 MHz 256 MB 4 Onboard Mandatory Mandatory DY-74BAA-DA
OpenVMS 600 MHz 512 MB 4 Onboard Mandatory Mandatory DY-74BAA-EA
OpenVMS 600 MHz 1 GB 4 Onboard Mandatory Mandatory DY-74BAA-FA
               
Linux-Ready 600 MHz 512 MB 4 Onboard Mandatory Mandatory DJ-74BAA-EA
Linux-Ready 600 MHz 1 GB 4 Onboard Mandatory Mandatory DJ-74BAA-FA
               
AlphaStation DS10 600-MHz Base Systems
OS CPU Memory PCI 2-10/100t Ports Hard Drive Storage Cage Order No.
Tru64 UNIX 600 MHz 256 MB 4 Onboard Mandatory Mandatory DA-74BAA-DW
Tru64 UNIX 600 MHz 512 MB 4 Onboard Mandatory Mandatory DA-74BAA-EW
Tru64 UNIX 600 MHz 1 GB 4 Onboard Mandatory Mandatory DA-74BAA-FW
               
OpenVMS 600 MHz 256 MB 4 Onboard Mandatory Mandatory DY-74BAA-DW
OpenVMS 600 MHz 512 MB 4 Onboard Mandatory Mandatory DY-74BAA-EW
OpenVMS 600 MHz 1 GB 4 Onboard Mandatory Mandatory DY-74BAA-FW
               
Linux-Ready 600 MHz 512 MB 4 Onboard Mandatory Mandatory DJ-74BAA-EW
Linux-Ready 600 MHz 1 GB 4 Onboard Mandatory Mandatory DJ-74BAA-FW
 
Step 2 – Select Mandatory Options (Storage Cage, System Disk, SCSI Controller, Power Cord)

10908_XX1.jpg (91023 bytes)

Step 2a – Mandatory Selection of Storage Cage
  • DS10 Systems support one Storage Cage
  • Selection of one Storage Cage is mandatory (no exceptions)
  • DS10 Internal Storage Cage: DS10 System with Internal Cage supports three storage devices:
    - Either three internal hard disk drives or one 5.25-inch half height backup tape and two internal hard disk drives
3X-BA10A-AA
  • DS10 Front Access Storage Cage: DS10 System with Front Access Cage supports up to four storage devices:
    - Two Compaq Universal disk drives plus two internal disk drives, or
    – One Front Access Universal Tape Drive (AIT or DAT) and two internal disk drives
3X-BA10B-AA
   
Step 2b – Internal Storage Cage - System Disk Drive - Mandatory
  • Selection of one system disk drive is mandatory for the Internal Storage Cage (3X-BA10A-AA)
    - Mandatory selection of one IDE or one internal SCSI system disk drive
    - Mandatory selection of SCSI adapter and SCSI cable kit required for internal SCSI disks and tape

10908_XX2.jpg (84309 bytes)

DS10 Storage Configuration Rules with Selection of Standard Storage Cage:
  • DS10 Systems configured with the Internal Storage Cage include a 600-MB 40X half height CD-ROM and
    1.44-MB diskette in dedicated drive slots
  • DS10 Systems configured with the Internal Storage Cage include three internal storage bays (two in the Storage cage
    plus one in the system box) that can be configured as follows:
    - Maximum of three internal disk drives (3.5-inch x 1-inch drives) or
    two internal disk drives (3.5-inch x 1-inch) and one 5.25-inch half height removable media device
  • Mandatory selection of SCSI adapter and SCSI cable kit is required for internal SCSI disks or tapes
  • IDE Disk drive cable kits are included with the system

NOTE: When a tape drive is ordered it will be installed in the top slot (Slot 3) and the CD will be installed in Slot 4.

   
Internal IDE Disk Drives 20 GB 7,200 rpm IDE (UDMA) drive 3X-RE58A-AA
40-GB 7,200 rpm IDE (UDMA) drive 3X-RE58A-BA
NOTE: Requires minimum console firmware V5.9-6 or higher. Updates available at http://ftp.digital.com/pub/Digital/Alpha/firmware/interim/
ds10/v5.9-6/

NOTE
: This website is available in English only.
   
Internal SCSI Disk Drives 18.2-GB Ultra3 SCSI 10,000 rpm drive

DS-RZ3EF-WA

36.4-GB Ultra3 SCSI 10,000 rpm drive

DS-RZ3FD-WA

       
Internal Tape Drives DAT 12/24-GB 4-mm 5.25-inch half-height SCSI tape drive, top gun blue; requires single-ended UltraSCSI or Ultra2 adapter (KZPBA-CA, 3X-DEPVZ-AA, 3X-KZPCA-AA, or KZPCM-DA) and SCSI cable TLZ10-LB
DAT 20/40-GB 4-mm 5.25-inch half-height Ultra2 (LVD) SCSI tape drive, top gun blue; requires Ultra2 (LVD) adapter and SCSI cable (Tru64 UNIX and OpenVMS only) 3X-SD20X-LB
AIT 5.25-inch half-height 35/70-GB 8-mm Wide UltraSCSI tape drive, top gun blue; requires single ended UltraSCSI adapter or Ultra2 adapter (KZPBA-CA, 3X-DEPVZ-AA, KZPCM-DA, or 3X-KZPCA-AA) and SCSI cable (Tru64 UNIX and OpenVMS only) 3X-SZ35X-LB
AIT 35/70-GB tape drive (LVD), carbon black 3R-A2392-AA
AIT 5.25-inch half-height 50/100-GB 8-mm Ultra2 (LVD) SCSI tape drive, top gun blue; requires Ultra2 (LVD) adapter and SCSI cable (Tru64 UNIX and OpenVMS only)
3X-SZ50X-LB
Wide-to-narrow SCSI adapter SN-PBXKP-BA

10908_XX3.jpg (91350 bytes)

Front Access Storage Cage System Disk Drive Selection - Mandatory
  • Selection of one Compaq Universal system disk drive or Universal tape drive is mandatory for each Front Access Storage Cage
  • Mandatory selection of one Compaq Universal SCSI system disk drive or Universal tape drive
  • Mandatory selection of SCSI adapter is required for Front Access Storage Cage
  • SCSI cable with connections to the four disk drives is included with the Front Access Storage Cage
     
DS10 Storage Configuration Rules with Selection of Front Access Storage Cage:
  • DS10 Systems configured with Front Access Storage Cage include a 600-MB 24X slim line CD-ROM and 1.44-MB drive in dedicated drive slots
  • DS10 Systems configured with the Front Access Storage Cage include four storage bays (two Compaq Universal SCSI disk drives and two internal SCSI drives) which can be configured as follows:
  • Maximum of two internal disk drives (3.5-inch x 1-inch drives) and two Compaq Universal disk drives (3.5-inch x 1-inch) or one Front Access Universal tape drive (AIT or DAT) and two internal disk drives.
  • Mandatory selection of SCSI adapter for Front Access Cage Systems
  • SCSI cable included with Front Access Cage

NOTE: IDE drives may not be used on Front Access Cage systems.

      
Internal SCSI Disk Drives
(For Drives Internal to System)
18.2-GB 10,000 rpm Ultra3 SCSI drive DS-RZ3EF-WA
36.4-GB 10,000 rpm Ultra3 SCSI drive DS-RZ3FD-WA
    
Universal Disk Drives
(For Front Access Storage Cage)
18.2-GB Ultra3 (LVD) 10,000 rpm 1-inch Universal drive 3R-A0585-AA
18.2-GB Ultra3 SCSI 15,000 rpm 1-inch Universal drive 3R-A1543-AA
36.4-GB Ultra3 SCSI 10,000 rpm 1-inch Universal drive 3R-A0919-AA
36.4-GB Ultra 3 SCSI 15,000 rpm 1-inch Universal drive 3R-A3079-AA
72.8-GB Ultra 3 (LVD) 10,000 rpm 1-inch Universal drive 3R-A3050-AA
18.2-GB U320 SCSI 15,000 rpm 1-inch Universal disk drive 3R-A3848-AA
36.4-GB U320 SCSI 10,000 rpm 1-inch Universal disk drive 3R-A3838-AA
36.4-GB U320 SCSI 15,000 rpm 1-inch Universal disk drive 3R-A3849-AA
72.8-GB U320 SCSI 10,000 rpm 1-inch Universal disk drive 3R-A3839-AA
72.8-GB U320 SCSI 15,000 rpm 1-inch Universal disk drive 3R-A3851-AA
146-GB U320 SCSI 10,000 rpm 1-inch Universal disk drive 3R-A3841-AA
   
Universal Tape Drives

(For Front Access Storage Cage)

AIT 35/70-GB LVD Universal tape drive, uses two slots 3R-A2396-AA
AIT 50/100-GB LVD Universal tape drive, uses two slots 3R-A2779-AA
DAT 20/40-GB DDS4 LVD Universal tape drive, uses two slots 3R-A2780-AA
   
Step 2d – Mandatory Selection of Power Cord
 
  • Front Access Storage Cage:
  • Mandatory selection of SCSI adapter is required for Front Access Storage Cage
  • Front Access Storage Cage includes SCSI cable kit for connection to four disks
  • Internal Storage Cage:
  • Mandatory selection of SCSI adapter and SCSI cable kit are required for Standard Storage Cage systems with SCSI disk or tapes
SCSI Adapters
(For Internal and Front Access Drives)
PCI 1-channel Ultra2 SCSI adapter (LVD) 3X-KZPCA-AA
PCI 2-channel multi-mode Ultra3 LVD SCSI adapter, VHDCI (Tru64 UNIX V5.1 or higher and OpenVMS V7.2-2 or higher) No shared SCSI or SDLT tape/library support. 3X-KZPEA-DB
NOTE: Patch kit required, kit available at
http://ftp1.support.compaq.com/public/Digital_UNIX/v5.1/
NOTE
: This website is available in English only.
PCI combo card - PCI 2-channel UltraSCSI single-ended adapter and 10/100 Mbit KZPCM-DA
PCI combo card - 1-channel Ultra2 SCSI (LVD) Graphics, 10/100 Ethernet (Tru64 UNIX and OpenVMS only) 3X-DEPVZ-AA
PCI 1-channel UltraSCSI RAID controller (Tru64 UNIX and OpenVMS only) KZPAC-AA
NOTE: Internal or Front Access Disk Drives connected to a KZPAC controller are not capable of implementing the fault management features of this controller, such as 'hot spare' and 'automatic rebuilds’- manual rebuilds are supported.
PCI 3-port UltraSCSI RAID controller (4-MB/8-MB cache) (Tru64 UNIX V4.0F,OpenVMS V7.2-1) KZPAC-CA/CB
NOTE: Internal or Front Access Disk Drives connected to a KZPAC controller are not capable of implementing the fault management features of this controller, such as 'hot spare' and 'automatic rebuilds' - manual rebuilds are supported.
PCI 1-channel Ultra2 SCSI RAID controller, 4-MB cache (Linux-Ready Systems only) SN-KZPBC-AA
PCI 3-channel Ultra2 SCSI RAID controller, 32-MB cache (Linux-Ready Systems only) FR-PCTAR-IB
PCI 3-channel Ultra2 SCSI RAID controller, 64-MB cache (Linux-Ready Systems only) FR-PCTAR-IC
DS10 SCSI cable kit (with connections for three internal drives) 3X-BN51A-SE
NOTE: The DS10 SCSI cable kit is included with the Front Access Storage Cage. The DS10 SCSI cable kit is required for Internal Storage Cage systems with SCSI disks or tapes.
   
Step 2e – Mandatory Selection of Power Cord
Desktop Power Cords North America, 2.5-meter 3X-BN46K-2E
Australia, New Zealand, 2.5-meter (103541-011) BN19H-2E
Central Europe, 2.5-meter BN19C-2E
Denmark, 2.5-meter (103541-481) BN19K-2E
Egypt, India, South Africa, 2.5-meter (103541-AR1) BN19S-2E
Israel, 2.5-meter BN18L-2E
Italy, 2.5-meter BN35M-02
Japan, 2.5-meter, Dentori approved 3X-BN46G-02
Switzerland, 2.5-meter (103541-511) BN19E-2E
UK, Ireland, 2.5-meter BN19A-2E
Rackmount (M-Series Cabinet) Power Cords U.S./Canada BN20Z-4E
Non-U.S. 3X-BN46L-4E
Japan, 4.5-meter (right-angle connector) 3X-BN46D-4E
     
Step 3 - Memory - Optional
  • Maximum 2-GB memory
  • Systems include one memory kit; maximum two memory kits per system - each kit includes two industry-standard DIMMs with ECC support
256-MB memory kit, two 200-pin, 100-MHz, 128-MB DIMMs 3X-MS310-CA
512-MB memory kit, two 200-pin, 100-MHz, 256-MB DIMMs 3X-MS310-DA
1-GB memory kit, two 200-pin, 100-MHz, 512-MB DIMMs 3X-MS310-EA
 
Step 4 - DVD-ROM Drive - Optional
16X DVD-ROM Drive – Supported in Internal Storage Cage only – not supported in Front Access Storage Cage – supported in slot 3 of the Internal Storage Cage and replaces standard CD-ROM (see diagram on page 6, Step 2b). Ships as spare, not integrated in manufacturing.

3X-PBXRV-BA

  
Step 5 - M-Series Cabinets - Optional
  • M-Series cabinet enclosures support up to 12 DS10 systems (H9A15).
  • M-Series enclosures require selection of the following items:
  • H9A10, or H9A15 Cabinet, 120V or 240V
  • Cabinet front door based on cabinet height
  • Factory integration
    
Cabinet Configuration Chart for AlphaServer DS10 Rackmount Systems
  • A minimum of two AlphaServer DS10 systems is required in the H9A15 M-Series cabinet.
  • Each system requires a DS10 M-Series Rackmount kit (3X-PBX01-AB).
  • Each system requires a rack mount power cord.
  • Up to six BA356 shelves supported; shelves cannot be mounted behind DS10 systems.
NOTE: The number of ballast kits required is determined only by the number of system boxes. Ballast kits are required according to the following chart:
For more information on M-Series Cabinet Enclosures, see
http://www.compaq.com/alphaserver/products/m-series/index.html
NOTE: This website is available in English only.
Cabinet Configuration Chart for AlphaServer DS10 (3U) Rackmount Systems with RA3000 and Disk Shelves (12U)
M-Series
Cabinet
System Rack Kit per DS10 system M-Series Cabinet Height/Space DS10 Systems StorageWorks

BA356/DS-SL13R Disk Shelves

Ballast Kits Required
H9A10-MC/MD 3X-PBX01-AB 67-inch/32U 1 or 2 6 2
      3 or 4 6 1
      5 6 1
      6 4 0
      7 2 0
      8, 9, or 10 0 0
H9A15-MC/MD 3X-PBX01-AB 79-inch/39U 2 or 3 6 2
      4 6 1
      5 6 1
      6 4 1
      7 2 0
      8 to 12 0 0
contents
 Overview   Standard Features   Systems/Options   Options   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) Options
Cabinet Configuration Chart for AlphaServer DS10 (3U) Rackmount Systems with RA3000 and Disk Shelves (12U)
  • 12U of vertical cabinet space is reserved for one RA3000 controller shelf and up to five disk shelves mounted in top of cabinet, front to back; an additional 2U of vertical space is required for RA3000 controller shelf UPS.
  • Disk shelves can be a combination of RA3000 DS-SWXRA-GN disk shelves and StorageWorks BA36R-RC/RD disk shelves.
  • RA3000 controller shelf supports a maximum of four DS-SWXRA-GN disk shelves; third and fourth DS-SWXRA-GN disk shelf ordered will be installed in rear of M-Series cabinet; rear mounted shelves require that a 2-meter SCSI cable (BN37A-02) be ordered separately.
  • Systems are supported in remaining vertical space. The following table considers space requirements for the DS10 system boxes and RA3000.
  • For ballast requirements refer back to "Cabinet Configuration Chart for AlphaServer DS10 (3U) with StorageWorks Shelves (4U)"
  
M-Series
Cabinet
System Rack Kit per DS10 system M-Series Cabinet Height/Space DS10 Systems StorageWorks
RA3000 + Shelves
H9A10-MC/MD 3X-PBX01-AB 67-inch/34U 1 1 + 5
       2 1 + 5
      3 1 + 5
H9A15-MC/MD 3X-PBX01-AB 79-inch /41U 2 1 + 5
      2 1 + 5
      3 1 + 5
    4 1 + 5
    
M-Series Rackmount Kit for AlphaServer DS10
  • Rackmount kit must be ordered separately
  • DS10 M-Series rackmount kit

3X-PBX01-AB

NOTE: Factory integration of a DS10 system drawer in a Compaq 9000 rackmount cabinet using rack kit, 3X-PBX01-AA, is not supported. Contact Custom Systems.
  
M-Series Cabinets 67-inch cabinet enclosure with 59.5-inch or 34U of usable vertical space; 120V
dual-24A controller, each with 10 NEMA 5-15R outlets, input power plug NEMA L5-30P, Americas, Asia Pacific; includes rear door, top fan tray, and two H7600-AA power distribution units
H9A10-MC
67-inch cabinet enclosure with 59.5-inch or 34U of usable vertical space; 240V
dual-16A controller, each with 12 IEC C13 outlets, input power plug IEC 309, 16A, Europe; includes rear door, top fan tray, and two H7600-DB power distribution units
H9A10-MD
79-inch cabinet enclosure with 71.7-inch or 41U of usable vertical space; 120V
dual-24A controller, each with 10 NEMA 5-15R outlets, input power plug NEMA L5-30P, Americas, Asia Pacific; includes rear door, top fan tray, and two H7600-AA power distribution units
H9A15-MC
79-inch cabinet enclosure with 71.7-inch or 41U of usable vertical space; 240V
dual-16A controller, each with 12 IEC C13 outlets, input power plug IEC 309, 16A, Europe; includes rear door, top fan tray, and two H7600-DB power distribution units
H9A15-MD
    
StorageWorks Shelves Supported in M-Series Cabinets with Front Doors (H9A10/H9A15) StorageWorks UltraSCSI single bus, single-ended shelf with 180W power supply and RETMA mounting kit BA36R-RC
StorageWorks UltraSCSI split bus, single-ended shelf with 180W power supply and RETMA mounting kit BA36R-RD
180W power supply for redundant power of a BA36R (includes power cord) CK-BA35X-HH
   
M-Series Cabinet Rear Cabinet Extender
  • Requires selection of one cabinet extender for each H9A10 or H9A15 cabinet
Rear cabinet extender, top gun blue, for H9A10-MC/MD cabinets H9C10-TE
Rear cabinet extender, top gun blue, for H9A15-MC/MD cabinets H9C15-TE
NOTE: Rear Cabinet Extender, H9C10-TE or H9C15-TE, is mandatory for second BA370.
   
M-Series Cabinet Front Door
  • Requires selection of door based on cabinet height
Front door, top gun blue, for H9A10-MC/MD cabinet enclosure H9C10-TF
Front door, top gun blue, for H9A15-MC/MD cabinet enclosure H9C15-TF
   
M-Series Cabinet Factory Integration
  • Mandatory selection
Factory Integration of systems and storage devices assembled and configured in cabinet enclosure for H9A10 or H9A15 cabinet enclosures

YS-ASCAA-AA

  
M-Series Cabinet Ballast Kits
  • Add ballast kits as required
  • Ballast is added to a cabinet at particular locations for specific configurations to meet safety regulations for installation, operation, and service; see Cabinet Configuration Charts
Two 35 to 40 lb steel plates H9C10-MC
    
M-Series Cabinet Rackmount Power Cords U.S./Canada BN20Z-4E
Non-U.S. BN35S-4E
Japan, 2.5-meter 3X-BN46D-4E
  
CustomSystems Support
  • Cabinets that contain systems and storage must be assembled by qualified assemblers: Compaq Manufacturing, CustomSystems, or an authorized Compaq Certified Integration Partner.
  • For custom integration of systems, options, cabinet expansion offerings, and additional Compaq and third-party devices, or for other cabinets, doors, and trim kits of a different color, contact CustomSystems at 1-800-AT COMPAQ, or your local authorized Compaq Certified Integration Partner.
  
Step 6 - External Storage - Optional
  • Tape drives require an LVD adapter (3X-KZPCA-AA or 3X-KZPEA-DB) or single-ended UltraSCSI adapter (KZPBA-CA or KZPCM-DA) and country-specific power cord. NOTE: 3X-KZPEA-DB does not support SDLT tape/libraries.
Tape Devices
AIT Tabletop Tape Drives AIT 35/70-GB 8-mm LVD tabletop tape drive, North America carbon black; requires LVD adapter 216885-001
Same as above, International 216885-B31
Same as above, Japan 216885-291
AIT 50/100-GB 8-mm SCSI tabletop tape drive with 120V North American power cord, carbon black; requires Ultra2 (LVD) adapter 157767-002
Same as above, International 157767-B32
Same as above, Japan 157767-292
  
AIT Hot-plug Tape Drives
  • AIT hot-plug tape drives require two Universal slots
AIT 35/70-GB hot-plug LVD Universal tape drive, uses two slots in 43xxx shelves 3R-A2396-AA
AIT 50/100-GB hot-plug LVD Universal tape drive, uses two slots in 43xxx shelves 3R-A2779-AA
  
AIT Autoloaders AIT 35-GB tabletop autoloader, 8 cartridge, U.S. 292355-001
Same as above, International 292355-B31
AIT 35-GB rackmount autoloader, 8 cartridge, U.S. 280349-001
Same as above, International 280349-B31
AIT Rail kit for rackmount autoloader 284930-001
 
AIT Tape Libraries SSL2020 AIT tabletop library with one AIT 50-GB drive and 20 slots, LVD 175195-B21
SSL2020 AIT tabletop library with two AIT 50-GB drives and 20 slots, LVD 175195-B22
SSL2020 AIT rackmount library with one AIT 50-GB drive and 20 slots, LVD 175196-B21
SSL2020 AIT rackmount library with two AIT 50-GB drives and 20 slots, LVD 175196-B22
    
DAT Tabletop Tape Drives DAT 20/40-GB 4-mm Wide Ultra2 (LVD) tabletop SCSI tape drive with 120V
North American power cord, carbon black; requires Ultra2 (LVD) adapter
157770-002
Same as above, International 157770-B32
Same as above, Japan 157770-292
  
DAT Hot-plug Tape Drive DAT 20/40-GB DDS4 hot-plug LVD Universal tape drive, uses two slots in 43xxx shelves 3R-A2780-AA
   
DAT Autoloaders DAT 20/40-GB auto loader external; requires BN31W-xx SCSI cable and
3X-KZPCA-AA, or 3X-DEPVZ-AA adapter, North America
166505-001
Same as above, International 166505-B31
Same as above, Japan

166505-291

        
DLT/SDLT Tabletop Tape Drives DLT8000 tabletop 40/80-GB DLT external tape drive, carbon black - requires
3X-KZPCA-AA LVD adapter - U.S.
146197-B23
Same as above – Japan 146197-292
SDLT tabletop 110/220-GB external tape drive, carbon black- requires 3X-KZPCA-AA LVD adapter - U.S. 192103-002
Same as above – International 192103-B32
Same as above – Japan 192103-292
SDLT tabletop 160/320-GB external tape drive, carbon black - requires 3X-KZPCA-AA LVD adapter - U.S. 257319-001
Same as above - International 257319-B31
Same as above - Japan 257319-291
   
DLT/SDLT Tape Libraries Rackmount kit for H9Axx M-Series cabinets – required for mounting MSL5000 series in M-Series cabinets 254795-001
MSL5026DLX, DLT tabletop library with 1 40/80-GB DLT tape drive, LVD 231821-B21
MSL5026DLX, DLT tabletop library with 2 40/80-GB DLT tape drives, LVD 231821-B22
MSL5026DLX or MSL5026SL, DLT/SDLT rackmount library, 0 drives – requires rackmount kit (254795-001) 231979-B21
MSL5026DLX, DLT rackmount library with 1 40/80-GB DLT tape drive, LVD – requires rackmount kit (254795-001) 231891-B21
MSL5026DLX, DLT rackmount library with 2 40/80-GB DLT tape drives, LVD – requires rackmount kit (254795-001) 231891-B22
MSL5026S2, SDLT2 tabletop library with one 160/320-GB SDLT tape drive, LVD 293473-B21
MSL5026S2, SDLT2 tabletop library with two 160/320-GB SDLT tape drives, LVD 293473-B22
MSL5026S2 SDLT rackmount library, 0 drives, LVD – requires rackmount kit (254795-001) 293472-B21
MSL5026S2, SDLT2 rackmount library with one 160/320-GB SDLT tape drive, LVD 293472-B22
MSL5026S2, SDLT2 rackmount library with two 160/320-GB SDLT tape drive, LVD 293472-B23
MSL5026S2, SDLT2 rackmount library with one 160/320-GB SDLT tape drive with Fibre Channel, LVD 293472-B24
MSL5026S2, SDLT2 rackmount library with two 160/320-GB SDLT tape drive with Fibre Channel, LVD 293472-B25
 
MSL5026SL, SDLT tabletop library with one 110/220-GB SDLT tape drive, LVD 302511-B21
MSL5026SL, SDLT tabletop library with two 110/220-GB SDLT tape drives, LVD 302511-B22
MSL5026SL, SDLT rackmount library with one 110/220-GB SDLT tape drive, LVD 302512-B21
MSL5026SL, SDLT rackmount library with two 110/220-GB SDLT tape drives, LVD 302512-B22
 
MSL5052, 0 drives, LVD, rackmount 255102-B21
MSL5052SL SDLT tabletop library with 2 110/220-GB drives, LVD 249490-B21
MSL5052SL SDLT rackmount library with 2 110/220-GB drives, LVD – requires rackmount kit (254795-001) 249491-B21
MSL5052SL SDLT 110/220-GB drive field upgrade, LVD 231823-B22
 
MSL5052S2, SDLT2 tabletop library with two 160/320-GB SDLT tape drives, LVD, graphite 293476-B21
MSL5052S2, SDLT2 rackmount library with two 160/320-GB SDLT tape drive, LVD 293474-B21
MSL5052S2, SDLT2 rackmount library with two 160/320-GB SDLT tape drive with Fibre Channel, LVD 293474-B24
 
ESL9326SL SDLT tape library with six 110/220-GB SDLT tape drives, LVD 234615-B21
ESL9326SL SDLT tape library with eight 110/220-GB SDLT tape drives, LVD 234615-B22
ESL9326SL SDLT tape library with 16 110/220-GB SDLT tape drives, LVD 234615-B26
   
3U Rackmount Tape Drive Enclosure 3U LVD Rackmount Tape Drive Enclosure for use in H9Axx M-Series Cabinets,
0 drives, carbon black,
274338-B21
Rackmount Kit for H9Axx Series Cabinets, carbon black – required for mounting 3U Rackmount Tape Drive Enclosure in M-Series cabinet 3R-A3804-AA
NOTE: The 3U Tape Drive Enclosure supports up to four internal half-height removable devices, or up to two full height devices. Select up to four AIT or DAT devices, or two DLT/SDLT devices with 3U Rackmount Tape Drive Enclosure (274338-B21), or select preconfigured configurations listed below
AIT 35/70-GB 3U tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black 216884-B21
AIT 50/100-GB 3U tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black (157766-B22) 3R-A3753-AA
DAT 20/40-GB 3U tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black (157769-B22) 3R-A3752-AA
DLT8000 40/80-GB tape drive, requires 3X-KZPCA-AA LVD adapter 146196-B22
SDLT 110/220-GB tape drive, requires 3X-KZPCA-AA LVD adapter 192106-B25
SDLT 160/320-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black 257319-B21
Preconfigured Configurations
AIT 50-GB 3U rackmount kit, carbon black 274333-B21
DLT 40/80-GB, 3U rackmount kit, carbon black 274332-B21
DLT 40/80-GB, dual-drive, 3U rackmount kit, carbon black 274335-B21
SDLT 110/220-GB, 3U rackmount kit, carbon black 274331-B21
SDLT 110/220-GB, dual-drive, 3U rackmount kit, carbon black 274334-B21
  
5U Rackmount Tape Drive Enclosure 5U LVD Rackmount Tape Drive Enclosure, carbon black, for use in H9Axx M-Series Cabinets, 0 drives 274339-B21
Rackmount Kit for H9Axx Series Cabinets, carbon black - required for mounting 5U Rackmount Tape Drive Enclosure in M-Series cabinet 254795-001
NOTE: The 5U Rackmount Tape Drive Enclosure supports four full-height devices; select up to four DLT or SDLT devices with 274339-B21, or select preconfigured configurations listed below
DLT8000 40/80-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black 146196-B22
SDLT 110/220-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black 192106-B25
SDLT 160/320-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black 257319-B21
Preconfigured configurations
SDLT 110/220-GB Tape Array III, 5U rackmount kit, carbon black 274336-B21
DLT 40/80-GB Tape Array III, 5U rackmount kit, carbon black 274337-B21
DLT Tape Array III Model 0 enclosure, U.S. 168047-001
Same as above, International 168047-B31
Same as above, Japan 168047-291
Removable Media Devices for External StorageWorks Shelves DAT 12/24-GB 4-mm narrow SCSI tape drive in StorageWorks carrier DS-TLZ10-VA
DLT 40/80-GB tape drive in StorageWorks carrier DS-TZ90N-VW
    
Modular Data Routers The following Modular Data Routers are supported with MSL5000 and ESL9000 tape libraries:
One Fibre channel x 2 HVD Data Router (163082-B21) 3R-A2673-AA
One Fibre channel x 2 LVD Data Router (163083-B21) 3R-A2774-AA
Two Fibre channel x 4 LVD Data Router (262653-B21) 3R-A3740-AA
Two Fibre channel x 4 HVD Data Router ( (262654-B21) 3R-A3741-AA
 
Storage Controllers/Host Bus Adapters for StorageWorks Pedestals and Shelves
  • Storage controllers require a minimum operating system revision of Tru64 UNIX V4.0F or OpenVMS V7.1-2 unless noted otherwise.
  • Each storage controller/adapter uses one PCI slot
  Maximum # Supported  
  Tru64 UNIX OpenVMS Linux  
PCI-to-Fibre Channel host bus adapter (168794-B21) 2 2 - DS-KGPSA-CA
PCI to 2–Gb Fibre Channel adapter, 64-bit/33 MHz, single-channel (261329-B21) 2 2 - DS-KGPSA-DA
Fibre Channel cable
BNGBX-xx=02, 05, 15, 30, 50 meters (234457-B2x)
234457-B2x=1 (02m), 2 (05m), 3 (15m), 4 (30m), 5 (50m)
      BNGBX-xx
     
         
PCI-to-Fibre Channel 64-bit adapter, HBA - - 2 DS-SWLA4-PD
         
PCI 2-port UltraSCSI single-ended adapter and 10/100 Mb Ethernet combo adapter 2 2 - KZPCM-DA
VHDCI male-to-VHDCI male UltraSCSI cable,
xx=02, 2E(2.5), 03, 05, 10, 20 meters)
      BN37A-xx
PCI 1-port Ultra2 SCSI (LVD) single-ended adapter, 68-pin HD connector, requires BN38C cable (2 to 20 meters) to connect to single-ended UltraSCSI shelf 2 2 3 3X-KZPCA-AA
68-pin HD male-to-VHDCI male UltraSCSI cable; required for each external UltraSCSI shelf attached to KZPCA-AA adapter       BN38C-xx
PCI 2-channel LVD multi-mode Ultra3 SCSI adapter, VHDCI (only supported in dual-bus shelves) Requires use of U160 SCSI cables.
NOTE: Patch kit required, kit is available at http://ftp1.support.compaq.com/public/
Digital_UNIX/v5.1/

NOTE: This website is available in English only.
NOTE: No shared SCSI or SDLT tape/library support.
1

(V5.1 or higher)

1 - 3X-KZPEA-DB
U160 SCSI cables xx=02 for 6 feet, 03 for 12 feet, 04 for 24 feet       3X-BC56J-xx
PCI 1-port UltraSCSI differential adapter; includes external 68-pin HD connector; requires BN38C-xx cable (2-25 meters) to connect adapter to Differential UltraSCSI shelf or RAID controller
NOTE: Internal Connection is not supported.
2 2 2 3X-KZPBA-CC
68-pin HD male-to-VHDCI male UltraSCSI cable; required for each external UltraSCSI shelf attached to KZPBA-CA/CB adapter       BN38C-xx
         
PCI 3-channel Ultra2 LVD RAID controller, 64-bit, 64-MB cache
NOTES:
  • Supported with BA610-6D, BA356 DS-SL13R-xx, or DS-SSL14-Rx shelves only.
  • BA610-6D Nile Card must be at rev 0B to support internal RAID.
  • When installed in BA356 shelves, part number DS-BA35X-FC is required for non-factory installations.
  • Graphics card is required to run the DS-KZPCC-CE console utilities (SMOR) with SRM console versions lower than V6.0 or, alternatively can be run via serial line and terminal emulation software for SRM V6.0 or higher. PB2GA-JC/JD graphics cards are not supported.
  • EV6 systems not supported.
  • Tru64 UNIX V4.0F requires NHD3 and Patch Kit 4 (BL15) or later.
  • Tru64 UNIX V5.1 requires Patch Kit 3 (BL17) and Early Release Patch C462.
    - Patch Kit 3 (BL17) is located at: T64V5117-C0046202-11060-Manual-
    ER-20010615.tar
    - Patch C462.02 is located at:
    http://ftp1.support.compaq.com/public/
    unix/v5.1/

    NOTE: This website is available in English only.
  • TruCluster V5.1 (restricted to non-shared buses only)
2

(V4.0F/4.0G/
5.1/V5.1A)

- - DS-KZPCC-CE
   
PCI 1-channel Ultra2 LVD backplane RAID controller, 64-bit, 16-MB cache

NOTES:

  • Supported with BA610-6D, BA356, and DS-SL13R-xx shelves only.
  • BA610-6D Nile Card must be at rev 0B to support internal RAID.
  • When installed in BA356 shelves, part number DS-BA35X-FC is required for non-factory installations.
  • Graphics card is required to run the DS-KZPCC-AC console utilities (SMOR) with SRM console versions lower than V6.0 or, alternatively can be run via serial line and terminal emulation software for SRM V6.0 or higher. PB2GA-JC/JD graphics cards are not supported.
  • EV6 systems not supported. Tru64 UNIX V4.0F requires NHD3 and Patch Kit 4 (BL15) or later.
  • Tru64 UNIX V5.1 requires Patch Kit 3 (BL17) and Early Release Patch C462.
    - Patch Kit 3 (BL17) is located at: T64V5117-C0046202-11060-Manual-
    ER-20010615.tar
    - Patch C462.02 is located at:
    http://ftp1.support.compaq.com/public/
    unix/v5.1/

    NOTE: This website is available in English only.
  • TruCluster V5.1 (restricted to non-shared buses only)
2

(V4.0F/
4.0G/
5.1/ V5.1A)

- -

DS-KZPCC-AC

          
PCI 2-port PCI to Ultra3, 64-bit, 66-MHz, LVD backplane RAID controller with 128-MB cache (uses one PCI slot); requires connection to DS-SL13R-xx shelves. Requires use of U160 SCSI cables.
NOTE: Host-based volume shadowing or shared bus support not supported under OpenVMS.
- 1 - 3X-KZPDC-BE
PCI 4-port PCI to Ultra3, 64-bit, 66-MHz, LVD backplane RAID controller with 256-MB cache (uses one PCI slot); requires connection to DS-SL13R-xx shelves. Requires use of U160 SCSI cables.
NOTE: Host-based volume shadowing or shared bus support not supported under OpenVMS.
- 1 - 3X-KZPDC-DF
U160 SCSI cables
xx=02 for 6 feet, 03 for 12 feet, 04 for 24 feet
      3X-BC56J-xx
PCI 1-port UltraSCSI RAID controller with 4-MB cache memory, includes RAID Array 230/Plus Subsystem software and documentation kit and VHDCI female connector; tape drives not supported - 18.2-GB or higher disk drives not supported on KZPAC-xx RAID controllers 2 2 - KZPAC-AA
PCI 3-port UltraSCSI RAID controller with 4-MB cache memory, includes RAID Array 230/Plus Subsystem Software and documentation kit; tape drives not supported; SCSI cable required for each active port; requires
BN31K-0E for external third-port connection - 18.2-GB or higher disk drives not supported on KZPAC-xx RAID controllers
2 2 - KZPAC-CA
  
PCI 3-port UltraSCSI RAID controller with 8-MB cache memory, includes RAID Array 230/Plus Subsystem Software and documentation kit; tape drives not supported; SCSI cable required for each active port; requires BN31K-0E for external third-port connection - 18.2-GB or higher disk drives not supported on KZPAC-xx RAID controllers 2 2 - KZPAC-CB
Cache battery backup for KZPAC controller       KZPSC-UB
VHDCI male-to-VHDCI male UltraSCSI cable,
xx=02, 2E(2.5), 03, 05, 10, 20 m)

NOTE: Manufacturing may substitute BN37A-02 cable for specific cabinet configurations

      BN37A-xx
SCSI cable/bulkhead assembly kit with KZPAC-CA/CB, allows external connection of one third port       BN31K-0E
         
SCSI cable/bulkhead assembly kit, supports two third-port connections from
KZPAC-CA/CB, allows external connection of two third ports
      KZPAC-SB
PCI 1-channel Ultra2 SCSI RAID controller, 4-MB cache (Linux-Ready systems only) - - 3 SN-KZPBC-AA
PCI 3-channel Ultra2 SCSI RAID controller, 32-MB cache (Linux-Ready systems only) - - 3 FR-PCTAR-IB
   
External Storage
Solutions/Controllers
Enterprise Virtual Array Model 2C6D-B 60-Hz, includes 41U graphite storage cabinet,
M3220 controller assembly with dual HSV110 controllers, six M5214 dual-redundant FC
loop 14-bay drive enclosures, four 12-port FC loop switches; requires DS-KGPSA-xx (283198-B21)
DS-SV110-JA
Enterprise Virtual Array Model 2C6D-B 50-Hz, includes 41U graphite storage cabinet,
M3220 controller assembly with dual HSV110 controllers, six M5214 dual-redundant FC
loop 14-bay drive enclosures, four 12-port FC loop switches; requires DS-KGPSA-xx (283198-B22)
DS-SV110-JB

 

Enterprise Virtual Array Model 2C12D-B 60-Hz, includes 41U graphite storage cabinet,
M3220 controller assembly with dual HSV110 controllers, twelve M5214 dual-redundant
FC loop 14-bay drive enclosures, four 12-port FC loop switches; requires DS-KGPSA-xx (283199-B21)
DS-SV110-KA
Enterprise Virtual Array Model 2C12D-B 50-Hz, includes 41U graphite storage cabinet,
M3220 controller assembly with dual HSV110 controllers, twelve M5214 dual-redundant
FC loop 14-bay drive enclosures, four 12-port FC loop switches; requires DS-KGPSA-xx (283199-B22)
DS-SV110-KB

 

Enterprise Virtual Array Model 8C8D 60-Hz, includes 41U graphite storage cabinet, four
M3220 controller assembly with eight HSV110 controllers, eight M5214 dual FC loop
14-bay drive enclosures; requires DS-KGPSA-xx (283263-B21)
DS-SV110-LA
Enterprise Virtual Array Model 8C8D 50-Hz, includes 41U graphite storage cabinet, four
M3220 controller assembly, with eight HSV110 controllers, eight M5214 dual FC loop
14-bay drive enclosures; requires DS-KGPSA-xx (283263-B22)
DS-SV110-LB
Enterprise Virtual Array Model 0C6D-B 60-Hz, includes 41U graphite storage cabinet, six
M5214 dual-redundant FC loop 14-bay drive enclosures, twelve 16.4-feet/5-meter interconnect cables (to 2C12D-B); requires DS-KGPSA-xx (283264-B21)
DS-SV110-MA
Enterprise Virtual Array Model 0C6D-B 50-Hz, includes 41U graphite storage cabinet, sixM5214 dual-redundant FC loop 14-bay drive enclosures, twelve 16.4-feet/5-meter interconnect cables (to 2C12D-B); requires DS-KGPSA-xx (283264-B22) DS-SV110-MB
Enterprise Virtual Array Model 0C12D-B 60-Hz, includes 41U graphite storage cabinet, twelve M5214 dual-redundant FC loop 14-bay drive enclosures, twenty-four 16.4-feet/
5-meter interconnect cables (to two 2C12D-B’s); requires DS-KGPSA-xx (283265-B21)
DS-SV110-NA
Enterprise Virtual Array Model 0C12D-B 50-Hz, includes 41U graphite storage cabinet,
twelve M5214 dual-redundant FC loop 14-bay drive enclosures, twenty-four 16.4-feet/
5-meter interconnect cables (to two 2C12D-B’s); requires DS-KGPSA-xx (283265-B22)
DS-SV110-NB
   
SAN Solutions Kits Tru64 UNIX SAN Solutions Kit for Enterprise Virtual Array V2.0 (250193-B22)
NOTE: V5.1 requires Patch Kit 3:
T64V51B19AS0005-20020411.tar
V5.1A requires Patch Kit 3:
T64V51AB03AS0003-20020827.tar
QB-6RPAB-SB
OpenVMS SAN Solutions Kit for Enterprise Virtual Array V2.0 (250194-B22)
NOTE: V7.2-2 requires Tima Kit:
DEC-AXPVMS-VMS722_FIBRE_SCSI-V0200
V7.3 REQUIRES Tima Kit:
DEC-AXPVMS-VMS73_FIBRE_scsi-V0300
QB-6RPAC-SB
    
Modular Array 8000 RAID Solution Modular Array 8000 Fibre Channel RAID storage solution, 60 Hz; includes one HSG80 controller with 256-MB cache, one M2200 controller shelf, three dual-bus disk shelves, two I/O ports, two power supplies DS-SWXEB-CA
Modular Array 8000 Fibre Channel RAID storage solution, 50 Hz; includes one HSG80 controller with 256-MB cache, one M2200 controller shelf, three dual-bus disk shelves, two I/O ports, two power supplies DS-SWXEB-CB
    
Enterprise Modular Array 12000 Solution Enterprise Modular Array 12000 Fibre Channel RAID storage solution, 60 Hz DS-SWXEB-DA
Enterprise Modular Array 12000 Fibre Channel RAID storage solution, 50 Hz DS-SWXEB-DB
  
StorageWorks Fibre Channel Switches NOTE: For more information on the following switches, refer to http://www.compaq.com/products/quickspecs/
10457_na/10457_na.HTML

NOTE: This website is available in English only.
Fibre Channel SAN switch, 8-ports, 2-Gb, with Fabric Operating Software (258707-B21)

DS-DSGGD-AC

Fibre Channel SAN Switch, 16-ports, 2-Gb, with Fabric Operating Software (283056-B21)

DS-DSGGD-AD

Fibre Channel SAN Switch, 16-ports, 2 Gb, with Fabric Operating Software, two power supplies (Tru64 UNIX and OpenVMS) – requires Tru64 UNIX V5.1A patch kit: T64V51AB01AS0001-20020116.tar (287055-B21) DS-DSGGD-BA
Fibre Channel 2-Gb 64-port Core Switch, with Fabric Operating software DS-DSGGE-AB
Unmanaged Fibre Channel 7-port Storage Hub, North America (Tru64 UNIX only) (234453-001) DS-SWXHB-07
Fibre Channel 7-port Storage Hub, International (Tru64 UNIX only) (234453-B31) DS-SWXHB-17
Fibre Channel 7-port Storage Hub, Japan (Tru64 UNIX only) (234453-291) DS-SWXHB-J7
Long wave GBIC (127508-B21) DS-DSGGA-MA
Short wave optical GBIC (380561-B21) DS-DXGGA-SA
2 x 4 LVD Fiber Channel to SCSI Network Storage Router (262653-B21) 3R-A3740-AA
  
McData 64-port Fibre Channel SAN Director Class Switch SAN Director 2 Gb, 64 ports DS-DMGGD-BA
SAN Edge Switch 2 Gb, 32 ports DS-DMGGE-BC
SAN Edge Switch 2 Gb, 16-ports DS-DMGGE-BB
NOTE: Connection for, or between, 1-Gb and/or 2-Gb SAN switches requires different cables. Refer to the Switches, Hubs, and Interconnects QuickSpecs at: http://www.compaq.com/products/quickspecs/
North_America/10490.html
Fibre Channel Disk Drives 36-GB 10K rpm dual-port 2-Gb/sec FC-AL 1-inch (25.4mm) drive (238590-B21) 3R-A3239-AA
72-GB 10K rpm dual-port 2-Gb/sec FC-AL 1-inch (25.4mm) drive (238921-B21) 3R-A3260-AA
36-GB 15K rpm dual-port 2-Gb/sec FC-AL 1-inch (25.4mm) drive (236205B21) 3R-A3210-AA
   
NOTE: Connection for, or between, 1-Gb and/or 2-Gb SAN switches requires different cables. Refer to the Switches, Hubs, and Interconnects QuickSpecs at: http://www.compaq.com/products/quickspecs/
North_America/10490.html
    
Removable Media Devices for External StorageWorks Shelves DAT 12/24-GB 4 mm narrow SCSI tape drive in StorageWorks carrier DS-TLZ10-VA
DLT 40/80-GB tape drive in StorageWorks carrier DS-TZ90N-VW
600-MB 32X CD-ROM drive in StorageWorks carrier DS-RRD47-VA
   
StorageWorks UltraSCSI Shelves
  • Requires selection of UltraSCSI adapter and SCSI cable
  • StorageWorks Shelf supports seven 3.5-inch x 1.6-inch hard disk drives; with the addition of redundant power supply, six drives are supported
  • StorageWorks shelf kits are mounted back-to-back in pedestals and cabinets
StorageWorks UltraSCSI single-bus shelf kit BA36R-RC
StorageWorks UltraSCSI split-bus shelf kit BA36R-RD
3-meter SCSI cable BN37A-03
    
Disk Drives
(Supported in StorageWorks UltraSCSI Shelves)
  • Maximum six (10,000 rpm) or seven (7,200 rpm) drives supported in StorageWorks shelf
  • One power supply supports a maximum of six 10,000 rpm disks
9.1-GB UltraSCSI drive 10,000 rpm DS-RZ1DD-VW
18.2-GB UltraSCSI drive 10,000 rpm DS-RZ1ED-VW
36.4-GB UltraSCSI drive 10,000 rpm DS-RZ1FC-VW
 
StorageWorks Universal Drive Shelves – Model 4314R (Ultra3) StorageWorks Model 4314R Ultra3 SCSI (LVD) single bus, Universal drive rackmount shelf, North America and International, except Japan (190209-001) DS-SL13R-AA
Same as above, Japan (190209-291) DS-SL13R-AJ
  
StorageWorks Universal Drive Shelves – Model 4354R (Ultra3) StorageWorks Model 4354R Ultra3 SCSI (LVD), dual bus, Universal drive rackmount shelf, North America and International, except Japan (190211-001) DS-SL13R-BA
Same as above, Japan (190211-291) DS-SL13R-BJ
 
StorageWorks Universal Drive Shelves – Model 4314T (Ultra3) StorageWorks Model 4314T, Ultra3, Universal Drive Shelves Single Bus, Tower, U.S. (190210-001)
DS-SL13T-AA
StorageWorks Model 4314T, Ultra3, Universal Drive Shelves Single Bus, Tower, International (190210-B31) DS-SL13T-AB
StorageWorks Model 4314T, Ultra3, Universal Drive Shelves Single Bus, Tower, Japan (190210-291) DS-SL13T-AJ
 
StorageWorks Universal Drive Shelves – Model 4200 to Model 4300 Upgrade I/O Modules StorageWorks Model 4300 Ultra 160 single-port LVD I/O Module (190212-B21) DS-SE3ZJ-DA
StorageWorks Model 4300 Ultra 160 dual-port LVD I/O Module (190213-B21) DS-SE3ZJ-SA
 
System Disk Drives
(Supported in Model 4314R, 4314T, or 4354R Universal Drive Shelf)
18.2-GB Ultra3 (LVD) 10,000 rpm 1-inch Universal drive 3R-A0585-AA
18.2-GB Ultra3 (LVD) 15,000 rpm 1-inch Universal drive 3R-A1543-AA
36.4-GB Ultra3 (LVD) 10,000 rpm 1-inch Universal drive 3R-A0919-AA
36.4-GB Ultra3 (LVD) 15,000 rpm 1-inch Universal drive 3R-A3079-AA
72.8-GB Ultra 3 (LVD) 10,000 rpm 1-inch Universal drive 3R-A3050-AA
18.2-GB U320 SCSI 15,000 rpm 1-inch Universal disk drive 3R-A3848-AA
36.4-GB U320 SCSI 10,000 rpm 1-inch Universal disk drive 3R-A3838-AA
36.4-GB U320 SCSI 15,000 rpm 1-inch Universal disk drive 3R-A3849-AA
72.8-GB U320 SCSI 10,000 rpm 1-inch Universal disk drive 3R-A3839-AA
72.8-GB U320 SCSI 15,000 rpm 1-inch Universal disk drive 3R-A3851-AA
146-GB U320 SCSI 10,000 rpm 1-inch Universal disk drive 3R-A3841-AA
   
Step 7 - UltraSCSI RAID Array Controllers & UltraSCSI RAID Packaged Solutions - Optional
Enterprise Virtual Array Model 8C8D Enterprise Virtual Array Model 8C8D 60-Hz, includes 42U opal storage cabinet, four M3220 controller assembly with eight HSV110 controllers, eight M5214 dual FC loop 14-bay drive enclosures 239782-001
Enterprise Virtual Array Model 8C8D 50-Hz, includes 42U opal storage cabinet, four M3220 controller assembly with eight HSV110 controllers, eight M5214 dual FC loop 14-bay drive enclosures 249977-B21
 
Virtual Array 2CXX and 8CXX Enterprise Virtual Array Model 2C6D 60-Hz 42U opal storage cabinet, M3220 controller assembly with dual HSV110 controllers, six M5214 dual FC loop 14-bay drive enclosures 234345-B21
Enterprise Virtual Array Model 2C6D -50-Hz 42U opal storage cabinet, M3220 controller assembly with dual HSV110 controllers, six M5214 dual FC loop 14-bay drive enclosures 234345-B22
Enterprise Virtual Array Model 2C12D 60-Hz, includes 42U opal storage cabinet, M3220 controller assembly with dual HSV110 controllers, 12 M5214 dual FC loop 14-bay drive enclosures 234346-B21
Enterprise Virtual Array Model 2C12D 60-Hz, includes 42U opal storage cabinet, M3220 controller assembly with dual HSV110 controllers, 12 M5214 dual FC loop 14-bay drive enclosures 234346-B22
Enterprise Virtual Array Model 8C8D 60-Hz, includes 42U opal storage cabinet, four M3220 controller assembly with eight HSV110 controllers, eight M5214 dual FC loop 14-bay drive enclosures 239782-001
Enterprise Virtual Array Model 8C8D 50-Hz, includes 42U opal storage cabinet, four M3220 controller assembly with eight HSV110 controllers, eight M5214 dual FC loop 14-bay drive enclosures 249977-B21
    
RAID Array 3000 Rackmount Controller Shelf
  • Selection of RA3000 Solutions Software Kit is required
  • Supported SCSI adapter - 3X-KZPBA-CC PCI 1-port UltraSCSI differential adapter
RA3000 rackmount controller shelf, blue, with one controller, 110V
Includes: UltraSCSI BA356 controller shelf, one HSZ22 2-channel controller with
16-MB cache, integrated Environmental Monitoring Unit (EMU), two 180W power supplies, two dual-port host differential UltraSCSI I/O SBBs, dual-channel UltraSCSI single-ended personality modules, one 120V 1000VA rackmount UPS, 5-m host SCSI cable (BN37A-05), BN38E-0B adapter, UPS serial cable, PC connection serial cable (DB-9), two 68-pin HD tri-link adapters (H8861-AA), two North American power cords, and RETMA mounting bracket (disk shelves and disks not included)
Requires: Solutions Software Kit for platform, host adapter, RA3000 disk shelf, and disks
Options: Second HSZ22 controller, up to four additional RA3000 disk shelves, cache memory upgrade
DS-SWXRA-GH
RA3000 rackmount controller shelf, blue, with one controller, 230V
Includes: UltraSCSI BA356 controller shelf, one HSZ22 2-channel controller with
16-MB cache, integrated Environmental Monitoring Unit (EMU), two 180W power supplies, two dual-port host differential UltraSCSI I/O SBBs, dual-channel UltraSCSI single-ended personality modules, one 230V 1000VA rackmount UPS, 5-m host SCSI cable (BN37A-05), BN38E-0B adapter, UPS serial cable, PC connection serial cable (DB-9), two 68-pin HD tri-link adapters (H8861-AA), RETMA mounting bracket (disk shelves and disks not included)
Requires: Solutions Software Kit for platform, two country-specific power cords, host adapter, RA3000 disk shelf, and disks
Options: Second HSZ22 controller, up to four additional RA3000 disk shelves, cache memory upgrade
DS-SWXRA-GK
   
RAID Array 3000 Rackmount Disk Shelf
  • Select one to four disk shelves
  • Third and fourth DS-SWXRA-GN disk shelf ordered will be installed in rear of M-Series cabinet; rear mounted shelves require that a 2-meter BN37A-02 SCSI cable be ordered
RA3000 rackmount disk shelf, blue, includes UltraSCSI BA356 disk shelf, two 180W
power supplies, single-ended UltraSCSI personality card, one half meter SCSI cable (BN37A-0E), two North American power cords, and RETMA mounting bracket (disks not included); order two country-specific power cords for non-North American use

DS-SWXRA-GN

   
HSZ22 Controller
  • Note that second HSZ22 controller ordered is field installed only, not factory installed; requires BN37A-0E SCSI jumper cable be ordered separately
Second HSZ22 controller with 16-MB cache and two 16-MB SIMMs for mirror cache, one BN37A-05 5-meter UltraSCSI cable, one BN38E-0B cable adapter - field installable only; note that second HSZ22 controller does not require additional Solution Software Kit DS-HSZ22-AA
Second HSZ22 controller with 32-MB cache and two 32-MB SIMMs for mirror cache, one BN37A-05 5-meter UltraSCSI cable, one BN38E-0B cable adapter - field installed only; note that second HSZ22 controller does not require additional Solution Software Kit DS-HSZ22-AB
     
RA3000 Solutions Software Kit
  • StorageWorks Command Console (SWCC) software
  • Platform specific software
  • Installation scripts and installation documentation
RA3000 Solutions Software Kit for Tru64 UNIX QB-5TWAB-SA
RA3000 Solutions Software Kit for OpenVMS QB-5TWAC-SA
     
HSG80 External Controllers Fibre Channel Controller (HSG80), includes 256-MB cache, requires following firmware:
8.6-4F ACS FW (222318-B22, QB-6BUAA-SD), one per controller
8.6-4S ACS FW (222364-B22, QB-6ENAA-SC), one per controller
8.6-4P ACS FW (222316-B22, QB-6CAAA-SD), one per controller
Requires Tru64 UNIX software: 222320-B23, QB-65RAB-SE, one per controller
Requires OpenVMS software: 222321-B22, QB-65RAC-SD, one per controller
DS-HSG80-BK
Additional 256-MB cache for HSG80 (380674-B21) DS-HSDIM-AC
Single cache battery, one per HSG80 controller (135823-B21) DS-SE2CS-CB
Model 2200 controller shelf for HSG80 controller (DS-SE2ZS-C8) – includes dual power supplies and power cables 135820-B21
    
StorageWorks Disk Array Family NOTE: The HP StorageWorks Disk Array Family, specifically the XP128 and XP1024, are now supported on AlphaServer DS10 systems. For product and ordering information, refer to the following Web pages: http://www.hp.com/products1/storage/products/disk_arrays/
highend/xp1024/index.html
http://www.hp.com/products1/storage/products/disk_arrays/
highend/xp128/index.html

The following part numbers have been assigned for reference purposes only:
3R-A4417-AA A7876A XP128 Disk Array Control Frame
3R-A4418-AA A7906A XP1024 Disk Array Control Frame
RA3000 Pedestals RA3000 UltraSCSI seven SBB slot pedestal cabinet, blue-gray, 230 volts, includes one DS-HSZ22-A controller, 16-MB cache, two host ports, two device ports, slot for second DS-HSZ22-AA, two redundant power supplies 204 watts with fans, one BN37A-05 cable, one BN38E-0B adapter, one serial cable, on UPS, two North American power cords DS-SWXRA-GC
RA3000 UltraSCSI seven SBB slot pedestal, blue-gray, 120/230 volts, includes two redundant power supplies 204 watts with fans, one BN37A-01 cable, two country power cords DS-SWXRA-GD
    
ESA 10000, RAID Array 7000, RAID Array 8000
  • Enterprise Storage Array 10000 and RAID Array 7000 (HSZ70) product set are supported on AlphaServer DS10 systems
  • Supported SCSI adapter for HSZ80/HSZ70 - 3X-KZPBA-CC PCI 1-port UltraSCSI differential adapter
  • Supported SCSI adapter for HSG80 - KGPSA-BC PCI 1-port Fiber-Channel adapter
     
Step 8 - Networks and Communications - Optional
  • Reference individual product information for operating system support.
  • Systems include dual embedded 10/100 BaseT Ethernet ports (BN25G-xx cable must be ordered separately)
  • Additional Ethernet ports can be added using available PCI slots
  
   Maximum # Supported  
  Tru64 UNIX OpenVMS Linux-
Ready
 
Ethernet 10/100        
PCI (32-bit, 33-MHz) single-port 10/100 Ethernet (UTP/RJ45) NIC
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
2 2 2 3X-DE600-AA
PCI 2-port 10/100 Mb, Fast Ethernet adapter, UTP, maximum one per system, maximum ten 10/100 Ethernet ports per system.
NOTE: Two 10/100 Ethernet ports included with DS10 system.
1 1 1 3X-DE602-AA
Single-port 100Mbps (MMF/duplex-SC) add-on daughter card for use with
3X-DE602-BB. The combined 3X-DE602-BB 3X-DE602-FA provides two 10/100 (UTP/RJ45s) and one 100Mbps (MMF/SC) ports in a single PCI slot option. Maximum two per system, maximum ten 10/100 Ethernet ports supported per system.

Use BN34A or BN34B cables.
NOTE: The 3X-DE602-TA cannot be used standalone.
NOTE: Two 10/100 Ethernet ports included with DS10 system.
2 2 - 3X-DE602-FA
PCI (32-/64-bit, 33-/66-MHz) dual-port 10/100 Ethernet (UTP/RJ45s) NIC and Base Module. (One 3X-DE602-TA or 3X-DE602-FA optional add-on daughter card can be combined with this module.) Maximum two per system, maximum ten 10/100 Ethernet ports per system.
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
NOTE: Two 10/100 Ethernet ports included with DS10 system.
2 2 - 3X-DE602-BB
Dual-port 10/100 Ethernet (UTP/RJ45) add-on daughter card for use with the 3X-DE602-BB only. The combined 3X-DE602-BB and 3X-DE602-TA modules provide four 10/100 (UTP/RJ45s) ports in a single PCI slot option; allows for a maximum of 16 ports per system. Maximum two per system, maximum ten 10/100 Ethernet ports per system.
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.

NOTE: The 3X-DE602-TA cannot be used standalone.

NOTE: Two 10/100 Ethernet ports included with DS10 system.

2 2 -

3X-DE602-TA

PCI 10/100 Mb 4-port Ethernet adapter, UTP 1 1 1 DE504-BA
Cable for 10BaseT twisted pair connection       BN25G-xx
    
PCI (32-/64-bit, 33-/66-MHz) single-port 1000 Mbps (MMF/SC) NIC; no on-board boot-ROM support.

Use BN34A or BN34B cables.

1 1 1

DEGPA-SA

     
Multi-function Ethernet 10/100
PCI combo adapter, Permedia P2 graphics, 10/100 Mbit NIC 1 1 1 3X-DEPVD-AA
PCI combo adapter, Permedia P2 graphics, 10/100 NIC, 1-port SCSI 1 1 - 3X-DEPVZ-AA
3X-DEPVZ-AA specific-use 3-meter LVD2 SCSI cable       BN37A-03
PCI-to-Gigabit Ethernet adapter – UTP, with RJ45 (no boot support) 1 1 1 DEGPA-TA
      
FDDI
PCI FDDI adapter, single attachment station (SAS), multi-mode fiber (MMF), SC connector 1 1 - 3X-DEFPA-AC
PCI (32-bit, 33-MHz) to FDDI DAS (MMF/duplex-SC) NIC.
Use BN34A, BN34B, or BN34D cables.
1 1 -

3X-DEFPA-DC

FDDI-specific cable - Multimode fiber optic (MMF) 62.5/125um duplex cable with SC-to-MIC connectors.
-xx = available lengths: (01, 03, 10) for 1, 3, 10 meters
      

BN34D-xx

SC-to-SC dual fiber optic cable mm, pp xx = length in meters       

BN34B-xx

PCI (32-bit, 33-MHz) to FDDI SAS (UTP/RJ45) NIC.

Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.

1 1 -

3X-DEFPA-UC

PCI (32-bit, 33-MHz) to FDDI DAS (UTP/RJ45s) NIC.

Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.

1 1 -

3X-DEFPA-MC

     
ATM
PCI (32-bit, 33-MHz) to 155 Mbps ATM, copper NIC with RJ45 connector.
Use BN25G-xx, or BN26M-xx cables.
2
(V4.0F)
2
(V7.2-1)
- 3X-DAPBA-UA
PCI (32-bit, 33-MHz) to 155 Mbps ATM fiber NIC with SC connector.
Use BN34B-xx cable.
2
(V4.0F)
2
(V7.2-1)
- 3X-DAPBA-FA
PCI (32-bit, 33-MHz) to 622 Mbps ATM fiber NIC with SC connector.
Use BN34B-xx cable.
1
(V4.0F)
2
(V7.2-1)
- 3X-DAPCA-FA
   
Asynchronous Communications (ASYNC)
PCI (32-bit, 33-MHz) to quad-port Async Communications NIC with DB-25 octopus cable   PBXDA-BA
PCI (32-bit, 33-MHz) to 8-port Async Communications NIC with DB-25 octopus cables     PBXDA-BB
PCI 16-port asynchronous controller, cable included; maximum three PBXDA-Ax per system 3
(V4.0F)
3 - PBXDA-AC
PBXDA-AC Asynchronous Connector Adapters
RJ45 to DB-25 converter cable   CXI01-AC
RJ45 to DEC MJ11 converter cable (8 pack)   CXI01-AF
    
Synchronous Communications (SYNC)
PCI (32-bit, 33-MHz) to dual-port intelligent synchronous communications NIC. Requires at least one (maximum two) BN34x synchronous cable listed below. 2 2 - 3X-PBXDD-AA
PCI (32-bit, 33-MHz) to quad-port intelligent synchronous communications NIC. Requires at least one (maximum four) BN34x synchronous cable listed below. 2 2 - 3X-PBXDD-AB
     
Synchronous-Specific Cables
EIA-530 single-port cable   3X-BC34G-06
V.24/EIA-232 single-port cable   3X-BC34L-06
V.11/x.21 single-port cable   3X-BC33S-06
V.35 single-port cable   3X-BC34T-06
Ethernet, FDDI, ATM Multi-use Cables
Multimode fiber optic (MMF) 62.5/125um duplex cable, with SC-to-ST connectors.
–xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, 30 meters
    BN34A-xx
Multimode fiber optic (MMF) 62.5/125um duplex cable, with SC-to-SC connectors.
-xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, 30 meters
  BN34B-xx
Category 5e (4-Unshielded Twisted Pairs / UTP) straight-through cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity.
-xx = available lengths: (0B, 0E, 01, 03, 04, 07) for 0.2, 0.5, 1, 3, 4, 7 meters
  BN25G-xx
Category 5e (4-Twisted Pairs, Screened/ ScTP) straight-through cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity.
-xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, 7 meters
  BN26M-xx
Category 5e (4-Unshielded Twisted Pairs / UTP) Xover cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity.
-xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, 7 meters
  BN24Q-xx
Category 5e (4-Twisted Pairs, Screened / ScTP) Xover cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity.
-xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, 7 meters
  BN28Q-xx
   
Step 9 - Graphics Adapters - Optional
  • RAID Configuration Utility is accessible via console port for Tru64 UNIX and OpenVMS systems; optional graphics capability available
  • Select graphics adapter, monitor, and country-specific keyboard if required
  • Open3D license ships with PowerStorm 300/350 graphics accelerators.
  Maximum # Supported  
   Tru64 UNIX OpenVMS Linux-
Ready
 
3Dlabs Oxygen VX1 32-MB PCI 2D graphics accelerator.
NOTE: Only VX1 cards can be used in a multihead environment.
4 4 1 SN-PBXGF-AB
PowerStorm 300 3D multi-head graphics accelerator with 15-MB frame buffer memory and 16-MB texture memory 3 3 - SN-PBXGD-AD
PowerStorm 350 3D multi-head graphics accelerator with 30-MB frame buffer memory and 32-MB texture memory 3 3 - SN-PBXGD-AE
PCI combo adapter, Permedia P2 graphics, 10/100 Mbit NIC 1 1 1 3X-DEPVD-AA
PCI combo adapter, Permedia P2 graphics, 10/100 NIC, 1-port SCSI 1 1 - 3X-DEPVZ-AA
  
Step 10 - Monitors - Optional
  • Graphics monitors other than those listed below can be used if compatible with SVGA graphics ordered with system
  • A video cable, 6-foot/1.8-meter length, is included with all variants of monitors
  • Video extension cable required if monitor is located more than 1.5-meter from system
  • Monitors ship with, but are not integrated with the system
     
Carbon/Silver Monitors V7550 17-inch (16-inch viewable image size) flat-faced shadow mask color monitor, two-tone (carbon/silver), 0.25mm dot pitch, VGA to 1024 x 768 @85 Hz, MPRII/TCO99/Energy Star compliant, Northern Hemisphere with NA power cord, VGA cable 3R-A4002-AA
P720 17-inch (16-inch viewable image size) auto-scanning color monitor, Diamondtron NF, 0.25-mm aperture grille pitch, VGA to 1280 x 1024 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with Euro power cord, VGA cable
NOTE: This variant can also be used for North America and Asia Pacific.
3R-A3389-AA
Same as above, APD, no power cord (244373-B24) 3R-A3390-AA
Same as above, with PRC power cord, CCIB (244373-AA1) 3R-A3391-AA
Same as above, Southern Hemisphere, with Australia/New Zealand power cord (244373-011) 3R-A3392-AA
 
P920 19-inch (18-inch viewable image size) auto-scanning color monitor, Diamondtron NF, 0.24 mm aperture grille pitch, VGA to 1600 x 1200 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable (244375-001) 3R-A3393-AA
Same as above, with Euro power cord (244375-021) 3R-A3394-AA
Same as above, with PRC power cord, CCIB (244375-AA1) 3R-A3396-AA
Same as above, Southern Hemisphere, 0.25 to 0.27 mm aperture grille pitch, with Australia/New Zealand power cord (244375-011) 3R-A3397-AA
 
P1220 22-inch (20-inch viewable image size) auto-scanning color monitor, Diamondtron NF, 0.24 mm aperture grille pitch, VGA to 1792 x 1344 @85Hz, dual video input, USB Hub, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable (244374-001) 3R-A3398-AA
Same as above, with Euro power cord (244374-021) 3R-A3399-AA
Same as above, APD, no power cord (244374-B24) 3R-A3400-AA
Same as above, with PRC power cord, CCIB (244374-AA1) 3R-A3401-AA
Same as above, Southern Hemisphere, with Australia/New Zealand power cord (244374-011) 3R-A3402-AA
     
Carbon/Silver Flat Panel Monitors TFT1825, 18-inch (18-inchviewable image size) TFT flat panel monitor, 0.28mm pixel pitch, 1600 x 1200 @60Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, one VGA, one DVI-I input connector. NA power cord, VGA and DVI-I cables 3R-A4292-AA
TFT1520, 15.1-inch (15-inch viewable image size) TFT flat panel monitor, 0.297 mm pixel pitch, 1024 x 768 @75 Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, two video input connectors (one VGA and one DVI-I), NA power cord, VGA and DVI-I cables 3R-A4249-AA
 
Video Extension Cable 6-foot/1.8-meter video extension cable

BN39C-02

   
Monitor Power Cords North America BN26J-1K
Australia, New Zealand, 2.5-meter (103541-011) BN19H-2E
Central Europe, 2.5-meter BN19C-2E
Denmark, 2.5-meter (103541-481) BN19K-2E
Egypt, India, South Africa, 2.5-meter (103541-AR1) BN19S-2E
Israel, 2.5-meter BN18L-2E
Italy, 2.5-meter (103541-461) BN35M-02
Japan, 2.5-meter, Dentori approved 3X-BN46F-02
Switzerland, 2.5-meter (103541-511) BN19E-2E
UK, Ireland, 2.5-meter BN19A-2E
     
Step 11 - Keyboards, Mouse
  • Keyboards are not included with the system and must be ordered separately
  • Selection of country-specific keyboard is recommended
  • Select an opal OpenVMS keyboard for use with VT5xx text terminals.
    Opal Carbon
Keyboard/Language OpenVMS Tru64 UNIX OpenVMS
U.S. keyboard LK461-A2 3R-LKQ48-BA 3X-LK462-A2
Arabic keyboard - 3R-LKQ48-BR -
Belgian keyboard LK461-AB 3R-LKQ48-AB 3X-LK462-AB
BHCSY keyboard - 3R-LKQ48-AX -
Canadian/English keyboard LK461-AQ - 3X-LK462-AQ
Canadian/French keyboard LK461-AC 3R-LKQ48-AC 3X-LK462-AC
Cyrillic keyboard (Russian) LK461-BT 3R-LKQ48-BT 3X-LK462-BT
Czech keyboard LK461-BV 3R-LKQ48-BV 3X-LK462-BV
Danish keyboard LK461-AD 3R-LKQ48-AD 3X-LK462-AD
Dutch keyboard LK461-AH 3R-LKQ48-AH 3X-LK462-AH
Finnish keyboard LK461-AF 3R-LKQ48-AF 3X-LK462-AF
French keyboard LK461-AP 3R-LKQ48-AP 3X-LK462-AP
German keyboard LK461-AG 3R-LKQ48-AG 3X-LK462-AG
Greek keyboard LK461-BH 3R-LKQ48-BH 3X-LK462-BH
Hebrew keyboard LK461-AT 3R-LKQ48-AT 3X-LK462-AT
Hungarian keyboard LK461-BQ 3R-LKQ48-BQ 3X-LK462-BQ
International keyboard - 3R-LKQ48-BA -
Italian keyboard LK461-AI 3R-LKQ48-AI 3X-LK462-AI
Japanese keyboard - 3R-LKQ48-AJ -
Korean keyboard - 3R-LKQ48-BK -
Latin-American keyboard - 3R-LKQ48-AR -
Norwegian keyboard LK461-AN 3R-LKQ48-AN 3X-LK462-AN
Polish keyboard LK461-BP 3R-LKQ48-BP 3X-LK462-BP
Portuguese keyboard LK461-AV 3R-LKQ48-AV 3X-LK462-AV
Romanian keyboard LK461-BL - 3X-LK462-BL
Simplified Chinese keyboard - 3R-LKQ48-CV -
Slovak keyboard LK461-CZ 3R-LKQ48-CZ 3X-LK462-CZ
Spanish keyboard LK461-AS 3R-LKQ48-AS 3X-LK462-AS
Swedish keyboard LK461-AM 3R-LKQ48-AM 3X-LK462-AM
Swiss/French keyboard LK461-AK 3R-LKQ48-AK 3X-LK462-AK
Swiss/German keyboard LK461-AL - 3X-LK462-AL
Traditional Chinese keyboard - 3R-LKQ48-BI -
Thai keyboard - 3R-LKQ48-CB -
Turkish Q keyboard LK461-BU 3R-LKQ48-BU 3X-LK462-BU
Turkish/F keyboard LK461-BW - 3X-LK462-BW
UK keyboard - 3R-LKQ48-AE -
Yugoslavian keyboard LK461-BY - 3X-LK462-BY
   
Mouse – Recommended
3-button mouse – carbon

3R-A3480-AA

  
Step 12 - Console Terminal - Optional
  • Any terminal can be used as a console device
  • Third-party console devices require an EIA-232 25-pin DSUB connector
VT510 video terminal; requires H8575-x cable, either male or female VT510-xx
Console cable, female connector H8575-A
Console cable, male connector H8575-D
Console cable, male connector (IBM compatible) H8575-E
     
Step 13- MEMORY CHANNEL - Optional
Tru64 UNIX Systems
  • Requires Tru64 UNIX V5.0A or later and either TruCluster™ Server license
    (QL-6BRAC-AA) or TruCluster Plus Software Package (QP-6R9AC-AA)
 
OpenVMS Systems
  • Requires OpenVMS V7.1-2 or later and OpenVMS Cluster license
    (QL-MUZAC-AA)
 
Configuring Information
  • Up to two PCI-to-System Area Network adapters (CCMAB-AA) are supported in a single system.
  • Two-node clusters can be configured by ordering a CCMAB-AA for each node and one BN39B-04 or BN39B-10 cable; cable connects directly to CCMAB-AA in each node.
  • For a two-node cluster that will not need to be rebooted when adding additional members, order one CCMAB-AA adapter and one BN39B-04 or BN39B-10 cable for each node, and one CCMHB-AA hub for the cluster.
  • For three- or four- node clusters, order one CCMAB-AA adapter and one
    BN39B-04 or BN39B-10 cable for each node, and one CCMHB-AA hub for the cluster
  • CCMHB-AA includes four CCMLB-AA line cards and supports up to four nodes; expansion up to eight system nodes can be achieved by adding up to four CCMLB-AA line cards.
  • If two CCMAB-AAs are configured in each system, a second CCMHB-AA is required.
  • If nodes must be separated by a distance longer than standard copper cables allow the CCMFB option converts the output of the standard CCMAB controller or CCMLB line card to single-mode fiber optic cable. The fiber optic connection may be up to 2,000 meters long between two CCMAB controllers connected in virtual hub mode, or 3,000 meters between a CCMAB controller and a CCMHB hub. (The connection from the CCMHB hub to a second system may also be 3,000 meters.) The CCMFB option requires a second PCI slot in the system from which it draws power only. It is normally connected to the corresponding CCMAB controller with the short BN39B-01 cable. The CCMFB is also used in the CCMHB hub where it occupies a slot normally used by the CCMLB line card, limiting expansion to four radial fiber optic connections.
  • CCMHB-BA hub expansion box provides additional slots for up to eight fiber optic connections. Two standard length single-mode fiber optic cables are available (BN34R-10 and BN34R-31); however, users normally provide this fiber optic connection. Fiber optic connectivity is completely transparent to the systems using it and has no performance impact.
  • For integration of MEMORY CHANNEL hubs into cabinet configurations, a rackmount kit (2T-MAVRK-AA) and power cord (BN35S-02) are required
   
MEMORY CHANNEL Controller PCI System Area Network Controller, maximum two CCMAB-AA
System Area Network Hub with four line cards; includes BN19P-2E power cord for Canada, Japan, and U.S. operations- for other regions, order appropriate power cord from list below CCMHB-AA
Hub expansion box with no line cards CCMHB-BA
Expansion line card for CCMHB hub CCMLB-AA
1-meter cable for CCMAB and CCMHB BN39B-01
4-meter cable for CCMAB and CCMHB BN39B-04
10-meter cable for CCMAB and CCMHB BN39B-10
Copper-to-single mode fiber optic converter - 5V (clock not affected) CCMFB-AA
Rackmount kit for CCMHB hub 2T-MAVRK-AA
Power cord for rackmount CCMHB hub BN35S-02
    
MEMORY CHANNEL Power Cords Australia, New Zealand (103541-011) BN19H-2E
Central Europe BN19C-2E
Denmark (103541-481) BN19K-2E
Egypt, India (103541-AR1) BN19S-2E
Ireland, United Kingdom BN19A-2E
Israel BN18L-2E
Italy (103541-461) BN35M-02
Switzerland (103541-511) BN19E-2E
       
Step 14 - Floor Stand
Floor Stand for AlphaServer/AlphaStation DS10

3X-BA73P-AA

   
Step 15 - Software - Required selection of media and documentation for first system on site
  • Software processor code = E
  
Tru64 UNIX
  • AlphaServer DS10Tru64 UNIX systems include Base license, Unlimited User license, Server Extension license, Internet Express, and Compaq Secure Web Server
  • AlphaStation DS10 Tru64 UNIX systems include 2-user Base license
 
When using Tru64 UNIX V5.0A or later Tru64 UNIX media and online documentation on CD-ROM QA-6ADAA-H8
Tru64 UNIX full hard copy documentation QA-6ADAA-GZ
TruCluster Plus Software Package with licenses for TruCluster Server, Logical Storage Manager, and AdvFS Utilities QP-6R9AC-AA
TruCluster Server License QL-6BRAC-AA
AdvFS Utilities License QL-0EGAE-AA
Logical Storage Manager License QL-2GVAE-AA
Advanced Server for Tru64 UNIX, 25 client concurrent use license QL-5U29M-3D
Advanced Server for Tru64 UNIX, 50 client concurrent use license QL-5U29M-3E
Advanced Server for Tru64 UNIX, 100 client concurrent use license QL-5U29M-3F
Advanced Server for Tru64 UNIX, 250 client concurrent use license QL-5U29M-3G
Advanced Server for Tru64 UNIX, 500 client concurrent use license QL-5U29M-3H
Layered products media and documentation for Tru64 UNIX on CD-ROM QA-054AA-H8
DECnet/OSI end-system license for Tru64 UNIX QL-MTJAE-AA
DECnet/OSI extended function license for Tru64 UNIX QL-MTKAE-AA
    
OpenVMS
  • AlphaServer DS10 OpenVMS systems include Base license with System Manager license and Compaq Enterprise Integration Server License Package for OpenVMS Revision V3.0A.
  • AlphaStation DS10 OpenVMS systems include Base license, Concurrent Use
    1-user license, and NAS 150 Client license.
  • Compaq Enterprise Integration Package includes licenses for TCP/IP Services for OpenVMS, DECwindows Motif for OpenVMS Alpha, DECprint Supervisor for OpenVMS Alpha Plus, DECprint Supervisor for OpenVMS Open, DECnet-Plus for OpenVMS Alpha End System, Archive/Backup System for OpenVMS Management Tools, Archive/Backup Agent for Windows NT, OpenVMS Disk Services for Windows NT, Office Server for OpenVMS, PATHWORKS 32, PATHWORKS V6 for OpenVMS – Advanced Server, and DIGITAL Office Server Client Access License
OpenVMS V7.1-2 media and online documentation on CD-ROM QA-MT1AR-H8
OpenVMS V7.2-1 media and online documentation on CD-ROM QA-MT1AT-H8
OpenVMS media and online documentation on CD-ROM QA-MT1AA-H8
OpenVMS hard copy documentation QA-001AA-GZ
Layered products media and documentation for OpenVMS on CD-ROM QA-03XAA-H8
Open3D for OpenVMS on CD-ROM, includes graphics drivers QA-0ADAA-H8
  • OpenVMS Concurrent Use licenses provide the right to interactively use the operating system by the specified number of concurrent users on a designated OpenVMS system. OpenVMS Concurrent Use licenses can be moved from one system to another at user discretion and can be shared in a mixed OpenVMS VAX and OpenVMS Alpha cluster.
  • OpenVMS Traditional Unlimited Use license is system specific and can only be used on one single system at a time. It cannot be shared between systems or in an OpenVMS VAX or OpenVMS Alpha Cluster.
Concurrent Use 1-user license QL-MT3AA-3B
Concurrent Use 2-user license QL-MT3AA-3C
Concurrent Use 4-user license QL-MT3AA-3D
Concurrent Use 8-user license QL-MT3AA-3E
Concurrent Use 16-user license QL-MT3AA-3F
Concurrent Use 32-user license QL-MT3AA-3G
Concurrent Use 64-user license QL-MT3AA-3H
Concurrent Use 128-user license QL-MT3AA-3J
Concurrent Use 256-user license QL-MT3AA-3K
Traditional Unlimited User license QL-MT2AE-AA
OpenVMS Cluster license for Alpha systems QL-MUZAC-AA
OpenVMS Cluster Client license for Alpha systems QL-3MRAC-AA
OpenVMS Cluster Client-to-Full OpenVMS Cluster Migration license QL-6J7AC-AA
   
Linux Kit - Optional Linux Red Hat CD-ROM Kit

QA-6M1AA-H8

   
Step 16 - Hardware and Software Support Services
  • Select one of the optional CarePaq™ Priority Service Packages described below that best supports the customer’s operational requirements for system availability.
   
CarePaq Priority Services
  • CarePaq Priority Services are available for AlphaServer/AlphaStation systems running Tru64 UNIX or OpenVMS operating systems. Priority Services are designed for the growing number of customers who need support beyond the basic warranty. Five packages are offered - Priority, Priority 24, Priority Silver, Priority Gold, and Priority Executive with coverage for both Principal servers/stations and SSPs (Subsequent System Packages) - that meet a full range of customer support requirements.
  
Program Features – Principal Server/Station
Priority 9 x 5 HW/SW support
4-hour response on-site hardware support
2-hour response for Bronze software support
License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
Condist update distribution for OpenVMS or Tru64 UNIX and their layered products. (Layered products not included on Condist can be ordered separately.)
  
Priority 24 24 x 7 HW/SW support
Named HW engineer
4-hour response on-site hardware support
2-hour response for Bronze software support
License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
Condist update distribution for OpenVMS or Tru64 UNIX and their layered products. (Layered products not included on Condist can be ordered separately.)
  
Priority Silver 24 x 7 HW Support with Named Engineer, 4-hour response
24 x 7 Silver SW Support - Named Account Rep, 1-hour response Monday – Friday, 8AM-5PM local time; 2-hour response remaining hours
License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
Condist update distribution for OpenVMS or Tru64 UNIX and their layered products. (Layered products not included on Condist can be ordered separately.)
Technical newsletter and SW activity review
Proactive Patch Notification
One (1) System Healthcheck per year
 
Priority Gold 24 x 7 HW support with Named Engineer, 4-hour response for on-site support
24 x 7 Gold SW support - Named Account Rep
30-minute callback (critical); 1-hour callback (non-critical)
License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
Condist update distribution for OpenVMS or Tru64 UNIX and their layered products. (Layered products not included on Condist can be ordered separately.)
Technical newsletter, SW activity review and 10 hours Upgrade impact planning
Proactive Revision Management
Two (2) System Healthchecks per year
Mandatory pre-qualification required
 
Priority Gold Executive 24 x 7 HW support with Named Engineer, two-hour response for on-site support
24 x 7 Gold SW support - Named Account Rep
30-minute callback (critical); one-hour callback (non-critical)
License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
Software update distribution on CD-ROM: OpenVMS or Tru64 UNIX and their layered products (Layered products not included on Condist can be ordered separately.)
Technical newsletter, SW activity review and 10 hours Upgrade impact planning
Proactive Revision Management
Two (2) System Healthchecks per year
Customer site must be within 25 miles of a Compaq service location
Mandatory pre-qualification required
  
Program Features – Additional Services
SSPs
(Subsequent System Packages)
For Priority, Priority 24, Priority Silver, Priority Gold, and Priority Gold Executive
HW Support at same level as corresponding package for Principal server/station
License Subscription: Compaq O/S (where applicable)
Telephone support through Principal server/station covered by full support package
Installation Pre-installation review
Unpacking of equipment
Assemble and test
Basic product usage info
No software installation added
Installation & Startup Compaq O/S Pre-installation review
Unpacking of equipment
Assemble and test
Basic product usage info
Install operating systems
Product configuration
Print and network access
Orientation
 
Model/CarePaq
Priority Service
Principal Server/Station
1 year
Principal Server/Station
3 years
Subsequent Systems
1 year
Subsequent Systems
3 years
AlphaServer/AlphaStation DS10      
Priority FP-A01BA-12 FP-A01BA-36 FP-A21BA-12 FP-A21BA-36
Priority 24 FP-A02BA -12 FP-A02BA-36 FP-A22BA-12 FP-A22BA-36
Priority Silver FP-A04BA-12 FP-A04BA-36 FP-A24BA-12 FP-A24BA-36
Priority Gold FP-A08BA-12 FP-A08BA-36 FP-A28BA-12 FP-A28BA-36
Priority Gold Exec. FP-A09BA-12 FP-A09BA-36 FP-A29BA-12 FP-A29BA-36
Installation FP-AINST-BA FP-AINST-BA FP-AINST-BA FP-AINST-BA
Priority FP-A01BA-12 FP-A01BA-36 FP-A21BA-12 FP-A21BA-36
Installation & Startup FP-ASTAR-BA FP-ASTAR-BA FP-ASTAR-BA FP-ASTAR-BA
  
NOTES:
  • AlphaServer/AlphaStation DS10 systems include three years hardware warranty with 5x9, on-site Next Business Day response.
  • New Compaq hardware options internal to the AlphaServer/AlphaStation enclosure receive the same warranty or service level as purchased with the server or station.
  • External storage devices/cabinets carry their own level of warranty and should be quoted separately for uplifted warranty services (CarePaq Priority Service).
  • In addition to the CarePaq Priority Services, uplifted warranty Supplemental Services are available for separate hardware and software support. For more information on Hardware and Software Supplemental Services and other service options available for AlphaServers and AlphaStations, consult your Sales Account Manager or visit http://www.compaq.com/services/
    NOTE: This website is available in English only.
 
contents
 Overview   Standard Features   Systems/Options   Options   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) TechSpecs
Physical Characteristics Dimensions
(H x W x D)
5.1 x 17.6 x 19 in (13 x 45 x 48 cm)
Weight (maximum) 36 lb (16.3 kg)
Cabinets H9A10 M-Series H9A15 M-Series
Dimensions
(H x W x D)
67 x 23.6 x 36.1 in
(170 x 60 x 91.6 cm)
79 x 23.6 x 36.1 in
(200 x 60 x 91.6 cm)
Shipping Dimensions 73 x 36 x 48 in
(185.5 x 91.5 x 122 cm)
85 x 36 x 48 in
(216 x 91.5 x 122 cm)
Weight Configuration dependent 1,000 lb/450 kg
Shipping Weight Configuration dependent, maximum payload
1,000 lb (453.6 kg)
1,056 lb (550 kg) (normal)
1,408 lb (640 kg) (maximum)
 
System Unit Environmental
Temperature Operating (Tower, Rackmount) 50?/font> to 104?/font> F (10?/font> to 40?/font> C)
NOTE: Maximum operating temperature at sea level. Reduce by 1.8?/font> F (1?/font> C) for each 2,000 ft (660 m) above sea level.
Non-operating –40?/font> to 151?/font> F (–40?/font> to 66?/font> C)
Humidity Operating 10% to 95%
Non-operating 20% to 80%
Heat Dissipation Single unit = 176 Watts = 601 BTU/Hr
Rack of 12 systems = 2112 Watts = ~7,212 BTU/Hr
Typical System AlphaServer DS10 600 MHz
Power Supply, 300W
Main logic board containing Alpha CPU, EV6, 600 MHz
Main memory = 1 GB
(3) Hard disk drive
(1) Floppy disk drive
(1) CD-ROM disk drive
(1) PCI Graphics Card
(1) PCI Graphics Card
Running system exerciser during the power measurement.
Measured Input Voltage = 116 VAC RMS @ 60Hz
Measured Input Current = 2.27 Amps RMS
Measured Input Power = 176 Watts
Altitude (unpressurized) Operating 40,000 ft (12,192 m)
Non-operating 10,000 ft (3,048 m)
NOTE: Higher altitudes are possible if maximum operating temperature is reduced.
Electrical (Power supplies are universal, PFC, auto ranging, 100/240 VAC)
Nominal Voltage (VAC) 100 to 120 VAC/220 VAC
Operating Voltage Range (VAC) (temporary condition) 90 to 128 VAC/180 to 265 VAC
Power Source Phase Single/Single/Single
Nominal Frequency (Hz) 60 Hz/50 Hz
Frequency Range (Hz) 59 to 61 Hz /49-51 Hz
Maximum Inrush Current 11 amps/22 amps
Power Supply (single cordset) 12 amps/5 amps
Acoustics (Declared values per ISO 9296 and ISO 7779)
AlphaServer DS10 with one HDD LWAdB LpAm, dBA
(Operator position)
LpAm, dBA
(Bystander Position)
Idle 5.7 48 41
Operating 6.0 52 45
Regulatory Agency Approvals UL: Listed to UL1950 (3rd edition)
CUL Listed: CAN/CSA-C22.2 No. 950-M95
TUV: EN 60950/A11: 1997 GS marked
FCC: Part 15 Class B
CE: EN55022, EN50082
VCCI Class II ITE
BMSI: CISPR22, CNS13438
C-Tick: CISPR22, AS/NZS 3548
Reviewed to AS/NZ 3260:1993 Australian/New Zealand Standard
EN 60950/A11: 1997 European Norm
IEC950 (2nd edition, 4th amend)

?2002 Compaq Information Technologies Group, L.P. All rights reserved. Compaq, the Compaq logo, AlphaServer, AlphaStation, CarePaq, Compaq Insight Manager, OpenVMS, StorageWorks, TruCluster, and Tru64 are trademarks of Compaq Information Technologies Group, L.P. in the U.S. and/or other countries. Windows is a registered trademark of Microsoft Corporation in the U.S. and/or other countries. UNIX is a registered trademark of The Open Group, Inc. in the U.S. and/or other countries. All other product names mentioned herein may be trademarks or registered trademarks of their respective companies.

Compaq shall not be liable for technical or editorial errors or omissions contained herein. The information is provided ?/font>as is?/font> without warranty of any kind and is subject to change without notice. The warranties for Compaq products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty.


   DA-10908 - U.S. - Version 19 - December 18, 2008