Options
| Cabinet Configuration Chart for
AlphaServer DS10 (3U) Rackmount Systems with RA3000 and Disk Shelves (12U) |
- 12U of vertical cabinet space is reserved for one RA3000 controller shelf and up to five
disk shelves mounted in top of cabinet, front to back; an additional 2U of vertical space
is required for RA3000 controller shelf UPS.
- Disk shelves can be a combination of RA3000 DS-SWXRA-GN disk shelves and StorageWorks
BA36R-RC/RD disk shelves.
- RA3000 controller shelf supports a maximum of four DS-SWXRA-GN disk shelves; third and
fourth DS-SWXRA-GN disk shelf ordered will be installed in rear of M-Series cabinet; rear
mounted shelves require that a 2-meter SCSI cable (BN37A-02) be ordered separately.
- Systems are supported in remaining vertical space. The following table considers space
requirements for the DS10 system boxes and RA3000.
- For ballast requirements refer back to "Cabinet Configuration Chart for AlphaServer
DS10 (3U) with StorageWorks Shelves (4U)"
|
| |
M-Series
Cabinet |
System Rack Kit
per DS10 system |
M-Series Cabinet
Height/Space |
DS10 Systems |
StorageWorks
RA3000 + Shelves |
| H9A10-MC/MD |
3X-PBX01-AB |
67-inch/34U |
1 |
1 + 5 |
| |
|
|
2 |
1 + 5 |
| |
|
|
3 |
1 + 5 |
| H9A15-MC/MD |
3X-PBX01-AB |
79-inch /41U |
2 |
1 + 5 |
| |
|
|
2 |
1 + 5 |
| |
|
|
3 |
1 + 5 |
| |
|
|
4 |
1 + 5 |
| |
| M-Series Rackmount
Kit for AlphaServer DS10 |
- Rackmount kit must be ordered separately
|
|
- DS10 M-Series rackmount kit
|
3X-PBX01-AB |
| NOTE:
Factory integration of a DS10 system drawer in a Compaq 9000 rackmount cabinet using rack
kit, 3X-PBX01-AA, is not supported. Contact Custom Systems. |
| |
| M-Series Cabinets |
67-inch cabinet enclosure with
59.5-inch or 34U of usable vertical space; 120V
dual-24A controller, each with 10 NEMA 5-15R outlets, input power plug NEMA L5-30P,
Americas, Asia Pacific; includes rear door, top fan tray, and two H7600-AA power
distribution units |
H9A10-MC |
|
67-inch cabinet enclosure with
59.5-inch or 34U of usable vertical space; 240V
dual-16A controller, each with 12 IEC C13 outlets, input power plug IEC 309, 16A, Europe;
includes rear door, top fan tray, and two H7600-DB power distribution units |
H9A10-MD |
|
79-inch cabinet enclosure with
71.7-inch or 41U of usable vertical space; 120V
dual-24A controller, each with 10 NEMA 5-15R outlets, input power plug NEMA L5-30P,
Americas, Asia Pacific; includes rear door, top fan tray, and two H7600-AA power
distribution units |
H9A15-MC |
|
79-inch cabinet enclosure with
71.7-inch or 41U of usable vertical space; 240V
dual-16A controller, each with 12 IEC C13 outlets, input power plug IEC 309, 16A, Europe;
includes rear door, top fan tray, and two H7600-DB power distribution units |
H9A15-MD |
| |
|
|
| StorageWorks
Shelves Supported in M-Series Cabinets with Front Doors (H9A10/H9A15) |
StorageWorks UltraSCSI single
bus, single-ended shelf with 180W power supply and RETMA mounting kit |
BA36R-RC |
| StorageWorks UltraSCSI split bus,
single-ended shelf with 180W power supply and RETMA mounting kit |
BA36R-RD |
|
180W power supply for redundant
power of a BA36R (includes power cord) |
CK-BA35X-HH |
| |
|
|
| M-Series Cabinet
Rear Cabinet Extender |
- Requires selection of one cabinet extender for each H9A10 or H9A15 cabinet
|
|
| Rear cabinet extender, top gun
blue, for H9A10-MC/MD cabinets |
H9C10-TE |
|
Rear cabinet extender, top gun
blue, for H9A15-MC/MD cabinets |
H9C15-TE |
|
NOTE: Rear
Cabinet Extender, H9C10-TE or H9C15-TE, is mandatory for second BA370. |
|
| |
|
|
| M-Series Cabinet Front Door |
- Requires selection of door based on cabinet height
|
|
|
Front door, top gun blue, for
H9A10-MC/MD cabinet enclosure |
H9C10-TF |
|
Front door, top gun blue, for
H9A15-MC/MD cabinet enclosure |
H9C15-TF |
| |
|
| M-Series Cabinet Factory
Integration |
|
|
|
Factory Integration of systems
and storage devices assembled and configured in cabinet enclosure for H9A10 or H9A15
cabinet enclosures |
YS-ASCAA-AA |
| |
|
| M-Series Cabinet Ballast Kits |
- Add ballast kits as required
|
|
- Ballast is added to a cabinet at particular locations for specific configurations to
meet safety regulations for installation, operation, and service; see Cabinet
Configuration Charts
|
|
Two 35 to 40 lb steel plates |
H9C10-MC |
| |
|
|
| M-Series Cabinet
Rackmount Power Cords |
U.S./Canada |
BN20Z-4E |
| Non-U.S. |
BN35S-4E |
|
Japan, 2.5-meter |
3X-BN46D-4E |
| |
| CustomSystems Support |
- Cabinets that contain systems and storage must be assembled by qualified assemblers:
Compaq Manufacturing, CustomSystems, or an authorized Compaq Certified Integration
Partner.
- For custom integration of systems, options, cabinet expansion offerings, and additional
Compaq and third-party devices, or for other cabinets, doors, and trim kits of a different
color, contact CustomSystems at 1-800-AT COMPAQ, or your local authorized Compaq Certified
Integration Partner.
|
| |
|
|
| Step 6 -
External Storage - Optional |
- Tape drives require an LVD adapter (3X-KZPCA-AA or 3X-KZPEA-DB) or single-ended
UltraSCSI adapter (KZPBA-CA or KZPCM-DA) and country-specific power cord.
NOTE: 3X-KZPEA-DB does not support SDLT
tape/libraries.
|
| Tape Devices |
| AIT Tabletop Tape Drives |
AIT 35/70-GB 8-mm LVD tabletop
tape drive, North America carbon black; requires LVD adapter |
216885-001 |
|
Same as above, International |
216885-B31 |
|
Same as above, Japan |
216885-291 |
|
AIT 50/100-GB 8-mm SCSI tabletop
tape drive with 120V North American power cord, carbon black; requires Ultra2 (LVD)
adapter |
157767-002 |
|
Same as above, International |
157767-B32 |
|
Same as above, Japan |
157767-292 |
| |
|
|
| AIT Hot-plug Tape Drives |
- AIT hot-plug tape drives require two Universal slots
|
|
|
AIT 35/70-GB hot-plug LVD
Universal tape drive, uses two slots in 43xxx shelves |
3R-A2396-AA |
|
AIT 50/100-GB hot-plug LVD
Universal tape drive, uses two slots in 43xxx shelves |
3R-A2779-AA |
| |
|
|
| AIT Autoloaders |
AIT 35-GB tabletop autoloader, 8
cartridge, U.S. |
292355-001 |
|
Same as above, International |
292355-B31 |
|
AIT 35-GB rackmount autoloader, 8
cartridge, U.S. |
280349-001 |
|
Same as above, International |
280349-B31 |
|
AIT Rail kit for rackmount
autoloader |
284930-001 |
| |
|
|
| AIT Tape Libraries |
SSL2020 AIT tabletop library with
one AIT 50-GB drive and 20 slots, LVD |
175195-B21 |
|
SSL2020 AIT tabletop library with
two AIT 50-GB drives and 20 slots, LVD |
175195-B22 |
|
SSL2020 AIT rackmount library
with one AIT 50-GB drive and 20 slots, LVD |
175196-B21 |
|
SSL2020 AIT rackmount library
with two AIT 50-GB drives and 20 slots, LVD |
175196-B22 |
| |
|
|
| DAT Tabletop Tape Drives |
DAT 20/40-GB 4-mm Wide Ultra2
(LVD) tabletop SCSI tape drive with 120V
North American power cord, carbon black; requires Ultra2 (LVD) adapter |
157770-002 |
|
Same as above, International |
157770-B32 |
|
Same as above, Japan |
157770-292 |
| |
|
|
| DAT Hot-plug Tape Drive |
DAT 20/40-GB DDS4 hot-plug LVD
Universal tape drive, uses two slots in 43xxx shelves |
3R-A2780-AA |
| |
|
|
| DAT Autoloaders |
DAT 20/40-GB auto loader
external; requires BN31W-xx SCSI cable and
3X-KZPCA-AA, or 3X-DEPVZ-AA adapter, North America |
166505-001 |
|
Same as above, International |
166505-B31 |
|
Same as above, Japan |
166505-291 |
| |
| DLT/SDLT Tabletop Tape Drives |
DLT8000 tabletop 40/80-GB DLT
external tape drive, carbon black - requires
3X-KZPCA-AA LVD adapter - U.S. |
146197-B23 |
|
Same as above Japan |
146197-292 |
|
SDLT tabletop 110/220-GB external
tape drive, carbon black- requires 3X-KZPCA-AA LVD adapter - U.S. |
192103-002 |
|
Same as above
International |
192103-B32 |
|
Same as above Japan |
192103-292 |
|
SDLT tabletop 160/320-GB external
tape drive, carbon black - requires 3X-KZPCA-AA LVD adapter - U.S. |
257319-001 |
|
Same as above -
International |
257319-B31 |
|
Same as above -
Japan |
257319-291 |
| |
|
|
| DLT/SDLT Tape Libraries |
Rackmount kit for H9Axx M-Series
cabinets required for mounting MSL5000 series in M-Series cabinets |
254795-001 |
|
MSL5026DLX, DLT tabletop library
with 1 40/80-GB DLT tape drive, LVD |
231821-B21 |
|
MSL5026DLX, DLT tabletop library
with 2 40/80-GB DLT tape drives, LVD |
231821-B22 |
|
MSL5026DLX or MSL5026SL, DLT/SDLT
rackmount library, 0 drives requires rackmount kit (254795-001) |
231979-B21 |
|
MSL5026DLX, DLT rackmount library
with 1 40/80-GB DLT tape drive, LVD requires rackmount kit (254795-001) |
231891-B21 |
|
MSL5026DLX, DLT rackmount library
with 2 40/80-GB DLT tape drives, LVD requires rackmount kit (254795-001) |
231891-B22 |
|
|
|
|
MSL5026S2, SDLT2 tabletop library
with one 160/320-GB SDLT tape drive, LVD |
293473-B21 |
|
MSL5026S2, SDLT2 tabletop library
with two 160/320-GB SDLT tape drives, LVD |
293473-B22 |
|
MSL5026S2 SDLT rackmount library,
0 drives, LVD requires rackmount kit (254795-001) |
293472-B21 |
|
MSL5026S2, SDLT2 rackmount
library with one 160/320-GB SDLT tape drive, LVD |
293472-B22 |
|
MSL5026S2, SDLT2 rackmount
library with two 160/320-GB SDLT tape drive, LVD |
293472-B23 |
|
MSL5026S2, SDLT2 rackmount
library with one 160/320-GB SDLT tape drive with Fibre Channel, LVD |
293472-B24 |
|
MSL5026S2, SDLT2 rackmount
library with two 160/320-GB SDLT tape drive with Fibre Channel, LVD |
293472-B25 |
| |
|
|
|
MSL5026SL, SDLT tabletop library
with one 110/220-GB SDLT tape drive, LVD |
302511-B21 |
|
MSL5026SL, SDLT tabletop library
with two 110/220-GB SDLT tape drives, LVD |
302511-B22 |
|
MSL5026SL, SDLT rackmount library
with one 110/220-GB SDLT tape drive, LVD |
302512-B21 |
|
MSL5026SL, SDLT rackmount library
with two 110/220-GB SDLT tape drives, LVD |
302512-B22 |
| |
|
|
|
MSL5052, 0 drives, LVD, rackmount |
255102-B21 |
| MSL5052SL SDLT tabletop library
with 2 110/220-GB drives, LVD |
249490-B21 |
|
MSL5052SL SDLT rackmount library
with 2 110/220-GB drives, LVD requires rackmount kit (254795-001) |
249491-B21 |
|
MSL5052SL SDLT 110/220-GB drive
field upgrade, LVD |
231823-B22 |
| |
|
|
|
MSL5052S2, SDLT2 tabletop library
with two 160/320-GB SDLT tape drives, LVD, graphite |
293476-B21 |
|
MSL5052S2, SDLT2 rackmount
library with two 160/320-GB SDLT tape drive, LVD |
293474-B21 |
|
MSL5052S2, SDLT2 rackmount
library with two 160/320-GB SDLT tape drive with Fibre Channel, LVD |
293474-B24 |
| |
|
|
|
ESL9326SL SDLT tape library with
six 110/220-GB SDLT tape drives, LVD |
234615-B21 |
|
ESL9326SL SDLT tape library with
eight 110/220-GB SDLT tape drives, LVD |
234615-B22 |
|
ESL9326SL SDLT tape library with
16 110/220-GB SDLT tape drives, LVD |
234615-B26 |
| |
|
|
| 3U Rackmount Tape Drive
Enclosure |
3U LVD Rackmount Tape Drive
Enclosure for use in H9Axx M-Series Cabinets,
0 drives, carbon black, |
274338-B21 |
|
Rackmount Kit for H9Axx Series
Cabinets, carbon black required for mounting 3U Rackmount Tape Drive Enclosure in
M-Series cabinet |
3R-A3804-AA
|
|
NOTE: The
3U Tape Drive Enclosure supports up to four internal half-height removable devices, or up
to two full height devices. Select up to four AIT or DAT devices, or two DLT/SDLT devices
with 3U Rackmount Tape Drive Enclosure (274338-B21), or select preconfigured
configurations listed below |
|
|
AIT 35/70-GB 3U tape drive,
requires 3X-KZPCA-AA LVD adapter, carbon black |
216884-B21 |
|
AIT 50/100-GB 3U tape drive,
requires 3X-KZPCA-AA LVD adapter, carbon black (157766-B22) |
3R-A3753-AA |
|
DAT 20/40-GB 3U tape drive,
requires 3X-KZPCA-AA LVD adapter, carbon black (157769-B22) |
3R-A3752-AA |
|
DLT8000 40/80-GB tape drive,
requires 3X-KZPCA-AA LVD adapter |
146196-B22 |
|
SDLT 110/220-GB tape drive,
requires 3X-KZPCA-AA LVD adapter |
192106-B25 |
|
SDLT 160/320-GB tape drive,
requires 3X-KZPCA-AA LVD adapter, carbon black |
257319-B21 |
|
Preconfigured Configurations |
|
| AIT 50-GB 3U rackmount kit,
carbon black |
274333-B21 |
|
DLT 40/80-GB, 3U rackmount kit,
carbon black |
274332-B21 |
|
DLT 40/80-GB, dual-drive, 3U
rackmount kit, carbon black |
274335-B21 |
|
SDLT 110/220-GB, 3U rackmount
kit, carbon black |
274331-B21 |
|
SDLT 110/220-GB, dual-drive, 3U
rackmount kit, carbon black |
274334-B21 |
| |
|
|
| 5U Rackmount Tape Drive
Enclosure |
5U LVD Rackmount Tape Drive
Enclosure, carbon black, for use in H9Axx M-Series Cabinets, 0 drives |
274339-B21 |
|
Rackmount Kit for H9Axx Series
Cabinets, carbon black - required for mounting 5U Rackmount
Tape Drive Enclosure in M-Series cabinet |
254795-001 |
|
NOTE: The
5U Rackmount Tape Drive Enclosure supports four full-height devices; select up to four DLT
or SDLT devices with 274339-B21, or select preconfigured configurations listed below |
|
|
DLT8000 40/80-GB tape drive,
requires 3X-KZPCA-AA LVD adapter, carbon black |
146196-B22 |
|
SDLT 110/220-GB tape drive,
requires 3X-KZPCA-AA LVD adapter, carbon black |
192106-B25 |
|
SDLT 160/320-GB tape drive,
requires 3X-KZPCA-AA LVD adapter, carbon black |
257319-B21 |
|
Preconfigured configurations |
|
|
SDLT 110/220-GB Tape Array III,
5U rackmount kit, carbon black |
274336-B21 |
|
DLT 40/80-GB Tape Array III, 5U
rackmount kit, carbon black |
274337-B21 |
|
DLT Tape Array III Model 0
enclosure, U.S. |
168047-001 |
|
Same as above, International |
168047-B31 |
|
Same as above, Japan |
168047-291 |
|
|
|
| Removable Media
Devices for External StorageWorks Shelves |
DAT 12/24-GB 4-mm narrow SCSI
tape drive in StorageWorks carrier |
DS-TLZ10-VA |
| DLT 40/80-GB tape drive in
StorageWorks carrier |
DS-TZ90N-VW |
| Modular Data Routers |
The following Modular Data
Routers are supported with MSL5000 and ESL9000 tape libraries: |
|
|
One Fibre channel x 2 HVD Data
Router (163082-B21) |
3R-A2673-AA
|
|
One Fibre channel x 2 LVD Data
Router (163083-B21) |
3R-A2774-AA
|
|
Two Fibre channel x 4 LVD Data
Router (262653-B21) |
3R-A3740-AA
|
|
Two Fibre channel x 4 HVD Data
Router ( (262654-B21) |
3R-A3741-AA |
| |
|
|
| Storage Controllers/Host Bus
Adapters for StorageWorks Pedestals and Shelves |
|
- Storage controllers require a minimum operating system revision of Tru64 UNIX V4.0F or
OpenVMS V7.1-2 unless noted otherwise.
|
|
- Each storage controller/adapter uses one PCI slot
|
|
| |
Maximum #
Supported |
|
| |
Tru64 UNIX |
OpenVMS |
Linux |
|
| PCI-to-Fibre Channel host bus
adapter (168794-B21) |
2 |
2 |
- |
DS-KGPSA-CA |
| PCI to 2Gb Fibre Channel
adapter, 64-bit/33 MHz, single-channel (261329-B21) |
2 |
2 |
- |
DS-KGPSA-DA |
Fibre Channel cable
BNGBX-xx=02, 05, 15, 30, 50 meters (234457-B2x)
234457-B2x=1 (02m), 2 (05m), 3 (15m), 4 (30m), 5 (50m) |
|
|
|
BNGBX-xx |
| |
|
|
|
| |
|
|
|
|
| PCI-to-Fibre Channel 64-bit
adapter, HBA |
- |
- |
2 |
DS-SWLA4-PD |
| |
|
|
|
|
| PCI 2-port UltraSCSI single-ended
adapter and 10/100 Mb Ethernet combo adapter |
2 |
2 |
- |
KZPCM-DA |
VHDCI male-to-VHDCI male
UltraSCSI cable,
xx=02, 2E(2.5), 03, 05, 10, 20 meters) |
|
|
|
BN37A-xx |
| PCI 1-port Ultra2 SCSI (LVD)
single-ended adapter, 68-pin HD connector, requires BN38C cable (2 to 20 meters) to
connect to single-ended UltraSCSI shelf |
2 |
2 |
3 |
3X-KZPCA-AA |
| 68-pin HD male-to-VHDCI male
UltraSCSI cable; required for each external UltraSCSI shelf attached to KZPCA-AA adapter |
|
|
|
BN38C-xx |
PCI 2-channel LVD multi-mode
Ultra3 SCSI adapter, VHDCI (only supported in dual-bus shelves) Requires use of U160 SCSI
cables.
NOTE: Patch kit required, kit is
available at http://ftp1.support.compaq.com/public/
Digital_UNIX/v5.1/
NOTE: This website is available in
English only.
NOTE: No shared SCSI or SDLT tape/library support. |
1 (V5.1 or higher) |
1 |
- |
3X-KZPEA-DB |
| U160 SCSI cables xx=02 for 6
feet, 03 for 12 feet, 04 for 24 feet |
|
|
|
3X-BC56J-xx |
PCI 1-port UltraSCSI differential
adapter; includes external 68-pin HD connector; requires BN38C-xx cable (2-25 meters) to
connect adapter to Differential UltraSCSI shelf or RAID controller
NOTE: Internal Connection is not
supported. |
2 |
2 |
2 |
3X-KZPBA-CC |
| 68-pin HD male-to-VHDCI male
UltraSCSI cable; required for each external UltraSCSI shelf attached to KZPBA-CA/CB
adapter |
|
|
|
BN38C-xx |
| |
|
|
|
|
PCI 3-channel Ultra2 LVD RAID
controller, 64-bit, 64-MB cache
NOTES:
- Supported with BA610-6D, BA356 DS-SL13R-xx, or DS-SSL14-Rx shelves only.
- BA610-6D Nile Card must be at rev 0B to support internal RAID.
- When installed in BA356 shelves, part number DS-BA35X-FC is required for non-factory
installations.
- Graphics card is required to run the DS-KZPCC-CE console utilities (SMOR) with SRM
console versions lower than V6.0 or, alternatively can be run via serial line and terminal
emulation software for SRM V6.0 or higher. PB2GA-JC/JD graphics cards are not supported.
- EV6 systems not supported.
- Tru64 UNIX V4.0F requires NHD3 and Patch Kit 4 (BL15) or later.
- Tru64 UNIX V5.1 requires Patch Kit 3 (BL17) and Early Release Patch C462.
- Patch Kit 3 (BL17) is located at: T64V5117-C0046202-11060-Manual-
ER-20010615.tar
- Patch C462.02 is located at:
http://ftp1.support.compaq.com/public/
unix/v5.1/
NOTE: This website is available in English only.
TruCluster V5.1 (restricted to non-shared buses only)
|
2 (V4.0F/4.0G/
5.1/V5.1A) |
- |
- |
DS-KZPCC-CE |
| |
| PCI 1-channel Ultra2 LVD
backplane RAID controller, 64-bit, 16-MB cache NOTES:
- Supported with BA610-6D, BA356, and DS-SL13R-xx shelves only.
- BA610-6D Nile Card must be at rev 0B to support internal RAID.
- When installed in BA356 shelves, part number DS-BA35X-FC is required for non-factory
installations.
- Graphics card is required to run the DS-KZPCC-AC console utilities (SMOR) with SRM
console versions lower than V6.0 or, alternatively can be run via serial line and terminal
emulation software for SRM V6.0 or higher. PB2GA-JC/JD graphics cards are not supported.
- EV6 systems not supported. Tru64 UNIX V4.0F requires NHD3 and Patch Kit 4 (BL15) or
later.
- Tru64 UNIX V5.1 requires Patch Kit 3 (BL17) and Early Release Patch C462.
- Patch Kit 3 (BL17) is located at: T64V5117-C0046202-11060-Manual-
ER-20010615.tar
- Patch C462.02 is located at: http://ftp1.support.compaq.com/public/
unix/v5.1/
NOTE: This website is available in English only.
TruCluster V5.1 (restricted to non-shared buses only)
|
2 (V4.0F/
4.0G/
5.1/ V5.1A) |
- |
- |
DS-KZPCC-AC |
| |
|
|
|
|
PCI 2-port PCI to Ultra3, 64-bit,
66-MHz, LVD backplane RAID controller with 128-MB cache (uses one PCI slot); requires
connection to DS-SL13R-xx shelves. Requires use of U160 SCSI cables.
NOTE: Host-based volume shadowing or
shared bus support not supported under OpenVMS. |
- |
1 |
- |
3X-KZPDC-BE |
PCI 4-port PCI to Ultra3, 64-bit,
66-MHz, LVD backplane RAID controller with 256-MB cache (uses one PCI slot); requires
connection to DS-SL13R-xx shelves. Requires use of U160 SCSI cables.
NOTE: Host-based volume shadowing or
shared bus support not supported under OpenVMS. |
- |
1 |
- |
3X-KZPDC-DF |
U160 SCSI cables
xx=02 for 6 feet, 03 for 12 feet, 04 for 24 feet |
|
|
|
3X-BC56J-xx |
| PCI 1-port UltraSCSI RAID
controller with 4-MB cache memory, includes RAID Array 230/Plus Subsystem software and
documentation kit and VHDCI female connector; tape drives not supported - 18.2-GB or higher disk drives not supported on KZPAC-xx RAID
controllers |
2 |
2 |
- |
KZPAC-AA |
PCI 3-port UltraSCSI RAID
controller with 4-MB cache memory, includes RAID Array 230/Plus Subsystem Software and
documentation kit; tape drives not supported; SCSI cable required for each active port;
requires
BN31K-0E for external third-port connection - 18.2-GB or higher
disk drives not supported on KZPAC-xx RAID controllers |
2 |
2 |
- |
KZPAC-CA |
| |
| PCI 3-port UltraSCSI RAID
controller with 8-MB cache memory, includes RAID Array 230/Plus Subsystem Software and
documentation kit; tape drives not supported; SCSI cable required for each active port;
requires BN31K-0E for external third-port connection - 18.2-GB
or higher disk drives not supported on KZPAC-xx RAID controllers |
2 |
2 |
- |
KZPAC-CB |
| Cache battery backup for KZPAC
controller |
|
|
|
KZPSC-UB |
VHDCI male-to-VHDCI male
UltraSCSI cable,
xx=02, 2E(2.5), 03, 05, 10, 20 m)NOTE:
Manufacturing may substitute BN37A-02 cable for specific cabinet configurations |
|
|
|
BN37A-xx |
| SCSI cable/bulkhead assembly kit
with KZPAC-CA/CB, allows external connection of one third port |
|
|
|
BN31K-0E |
| |
|
|
|
|
SCSI cable/bulkhead assembly kit,
supports two third-port connections from
KZPAC-CA/CB, allows external connection of two third ports |
|
|
|
KZPAC-SB |
| PCI 1-channel Ultra2 SCSI RAID
controller, 4-MB cache (Linux-Ready systems only) |
- |
- |
3 |
SN-KZPBC-AA |
| PCI 3-channel Ultra2 SCSI RAID
controller, 32-MB cache (Linux-Ready systems only) |
- |
- |
3 |
FR-PCTAR-IB |
|
|
External Storage
Solutions/Controllers |
Enterprise Virtual Array Model
2C6D-B 60-Hz, includes 41U graphite storage cabinet,
M3220 controller assembly with dual HSV110 controllers, six M5214 dual-redundant FC
loop 14-bay drive enclosures, four 12-port FC loop switches; requires DS-KGPSA-xx
(283198-B21) |
DS-SV110-JA |
|
Enterprise Virtual Array Model
2C6D-B 50-Hz, includes 41U graphite storage cabinet,
M3220 controller assembly with dual HSV110 controllers, six M5214 dual-redundant FC
loop 14-bay drive enclosures, four 12-port FC loop switches; requires DS-KGPSA-xx
(283198-B22) |
DS-SV110-JB |
|
Enterprise Virtual Array Model
2C12D-B 60-Hz, includes 41U graphite storage cabinet,
M3220 controller assembly with dual HSV110 controllers, twelve M5214 dual-redundant
FC loop 14-bay drive enclosures, four 12-port FC loop switches; requires DS-KGPSA-xx
(283199-B21) |
DS-SV110-KA |
|
Enterprise Virtual Array Model
2C12D-B 50-Hz, includes 41U graphite storage cabinet,
M3220 controller assembly with dual HSV110 controllers, twelve M5214 dual-redundant
FC loop 14-bay drive enclosures, four 12-port FC loop switches; requires DS-KGPSA-xx
(283199-B22) |
DS-SV110-KB |
|
Enterprise Virtual Array Model
8C8D 60-Hz, includes 41U graphite storage cabinet, four
M3220 controller assembly with eight HSV110 controllers, eight M5214 dual FC loop
14-bay drive enclosures; requires DS-KGPSA-xx (283263-B21) |
DS-SV110-LA |
|
Enterprise Virtual Array Model
8C8D 50-Hz, includes 41U graphite storage cabinet, four
M3220 controller assembly, with eight HSV110 controllers, eight M5214 dual FC loop
14-bay drive enclosures; requires DS-KGPSA-xx (283263-B22) |
DS-SV110-LB |
|
Enterprise Virtual Array Model
0C6D-B 60-Hz, includes 41U graphite storage cabinet, six
M5214 dual-redundant FC loop 14-bay drive enclosures, twelve 16.4-feet/5-meter
interconnect cables (to 2C12D-B); requires DS-KGPSA-xx (283264-B21)
|
DS-SV110-MA |
|
Enterprise Virtual Array Model
0C6D-B 50-Hz, includes 41U graphite storage cabinet, sixM5214 dual-redundant FC loop
14-bay drive enclosures, twelve 16.4-feet/5-meter interconnect cables (to 2C12D-B);
requires DS-KGPSA-xx (283264-B22) |
DS-SV110-MB |
|
Enterprise Virtual Array Model
0C12D-B 60-Hz, includes 41U graphite storage cabinet, twelve M5214 dual-redundant FC loop
14-bay drive enclosures, twenty-four 16.4-feet/
5-meter interconnect cables (to two 2C12D-Bs); requires DS-KGPSA-xx (283265-B21) |
DS-SV110-NA |
|
Enterprise Virtual Array Model
0C12D-B 50-Hz, includes 41U graphite storage cabinet,
twelve M5214 dual-redundant FC loop 14-bay drive enclosures, twenty-four 16.4-feet/
5-meter interconnect cables (to two 2C12D-Bs); requires DS-KGPSA-xx (283265-B22) |
DS-SV110-NB |
|
|
| SAN Solutions Kits |
Tru64 UNIX SAN Solutions Kit for
Enterprise Virtual Array V2.0 (250193-B22)
NOTE: V5.1 requires Patch Kit 3:
T64V51B19AS0005-20020411.tar
V5.1A requires Patch Kit 3:
T64V51AB03AS0003-20020827.tar |
QB-6RPAB-SB |
|
OpenVMS SAN Solutions Kit for
Enterprise Virtual Array V2.0 (250194-B22)
NOTE: V7.2-2 requires Tima Kit:
DEC-AXPVMS-VMS722_FIBRE_SCSI-V0200
V7.3 REQUIRES Tima Kit:
DEC-AXPVMS-VMS73_FIBRE_scsi-V0300 |
QB-6RPAC-SB |
|
|
| Modular Array 8000 RAID
Solution |
Modular Array 8000 Fibre Channel
RAID storage solution, 60 Hz; includes one HSG80 controller with 256-MB cache, one M2200
controller shelf, three dual-bus disk shelves, two I/O ports, two power supplies |
DS-SWXEB-CA |
|
Modular Array 8000 Fibre Channel
RAID storage solution, 50 Hz; includes one HSG80 controller with 256-MB cache, one M2200
controller shelf, three dual-bus disk shelves, two I/O ports, two power supplies |
DS-SWXEB-CB |
|
|
| Enterprise Modular Array 12000
Solution |
Enterprise Modular Array 12000
Fibre Channel RAID storage solution, 60 Hz |
DS-SWXEB-DA |
|
Enterprise Modular Array 12000
Fibre Channel RAID storage solution, 50 Hz |
DS-SWXEB-DB |
| |
|
|
| StorageWorks Fibre Channel
Switches |
NOTE: For
more information on the following switches, refer to http://www.compaq.com/products/quickspecs/
10457_na/10457_na.HTML
NOTE: This website is available
in English only. |
|
|
Fibre Channel SAN switch,
8-ports, 2-Gb, with Fabric Operating Software (258707-B21) |
DS-DSGGD-AC |
|
Fibre Channel SAN Switch,
16-ports, 2-Gb, with Fabric Operating Software (283056-B21) |
DS-DSGGD-AD |
|
Fibre Channel SAN
Switch, 16-ports, 2 Gb, with Fabric Operating Software, two power supplies (Tru64 UNIX and
OpenVMS) requires Tru64 UNIX V5.1A patch kit: T64V51AB01AS0001-20020116.tar
(287055-B21) |
DS-DSGGD-BA |
|
Fibre Channel 2-Gb 64-port Core
Switch, with Fabric Operating software |
DS-DSGGE-AB |
|
Unmanaged Fibre Channel 7-port
Storage Hub, North America (Tru64 UNIX only) (234453-001) |
DS-SWXHB-07 |
|
Fibre Channel 7-port Storage Hub,
International (Tru64 UNIX only) (234453-B31) |
DS-SWXHB-17 |
|
Fibre Channel 7-port Storage Hub,
Japan (Tru64 UNIX only) (234453-291) |
DS-SWXHB-J7 |
|
Long wave GBIC (127508-B21) |
DS-DSGGA-MA |
|
Short wave optical GBIC
(380561-B21) |
DS-DXGGA-SA |
|
2 x 4 LVD Fiber Channel to SCSI
Network Storage Router (262653-B21) |
3R-A3740-AA |
| |
|
|
| McData 64-port
Fibre Channel SAN Director Class Switch |
SAN Director 2 Gb, 64 ports |
DS-DMGGD-BA |
| SAN Edge Switch 2 Gb, 32 ports |
DS-DMGGE-BC |
|
SAN Edge Switch 2 Gb, 16-ports |
DS-DMGGE-BB |
|
NOTE:
Connection for, or between, 1-Gb and/or 2-Gb SAN switches requires different cables. Refer
to the Switches, Hubs, and Interconnects QuickSpecs at: http://www.compaq.com/products/quickspecs/
North_America/10490.html |
|
|
|
|
| Fibre Channel Disk Drives |
36-GB 10K rpm dual-port 2-Gb/sec
FC-AL 1-inch (25.4mm) drive (238590-B21) |
3R-A3239-AA |
|
72-GB 10K rpm dual-port 2-Gb/sec
FC-AL 1-inch (25.4mm) drive (238921-B21) |
3R-A3260-AA |
|
36-GB 15K rpm dual-port 2-Gb/sec
FC-AL 1-inch (25.4mm) drive (236205B21) |
3R-A3210-AA |
| Removable Media
Devices for External StorageWorks Shelves |
DAT 12/24-GB 4 mm narrow SCSI
tape drive in StorageWorks carrier |
DS-TLZ10-VA |
| DLT 40/80-GB tape drive in
StorageWorks carrier |
DS-TZ90N-VW |
|
600-MB 32X CD-ROM drive in
StorageWorks carrier |
DS-RRD47-VA |
| |
|
| StorageWorks UltraSCSI Shelves |
- Requires selection of UltraSCSI adapter and SCSI cable
|
|
- StorageWorks Shelf supports seven 3.5-inch x 1.6-inch hard disk drives; with the
addition of redundant power supply, six drives are supported
|
- StorageWorks shelf kits are mounted back-to-back in pedestals and cabinets
|
|
StorageWorks UltraSCSI single-bus
shelf kit |
BA36R-RC |
|
StorageWorks UltraSCSI split-bus
shelf kit |
BA36R-RD |
|
3-meter SCSI cable |
BN37A-03 |
| |
Disk Drives
(Supported in StorageWorks UltraSCSI Shelves) |
- Maximum six (10,000 rpm) or seven (7,200 rpm) drives supported in StorageWorks shelf
|
- One power supply supports a maximum of six 10,000 rpm disks
|
| 9.1-GB UltraSCSI drive 10,000 rpm |
DS-RZ1DD-VW |
|
18.2-GB UltraSCSI drive 10,000
rpm |
DS-RZ1ED-VW |
|
36.4-GB UltraSCSI drive 10,000
rpm |
DS-RZ1FC-VW |
| |
|
|
| StorageWorks
Universal Drive Shelves Model 4314R (Ultra3) |
StorageWorks Model 4314R Ultra3
SCSI (LVD) single bus, Universal drive rackmount shelf, North America and International,
except Japan (190209-001) |
DS-SL13R-AA
|
| Same as above, Japan (190209-291) |
DS-SL13R-AJ |
| |
|
|
| StorageWorks
Universal Drive Shelves Model 4354R (Ultra3) |
StorageWorks Model 4354R Ultra3
SCSI (LVD), dual bus, Universal drive rackmount shelf, North America and International,
except Japan (190211-001) |
DS-SL13R-BA
|
| Same as above, Japan (190211-291) |
DS-SL13R-BJ |
| |
|
| StorageWorks
Universal Drive Shelves Model 4314T (Ultra3) |
StorageWorks Model 4314T, Ultra3,
Universal Drive Shelves Single Bus, Tower, U.S. (190210-001) |
DS-SL13T-AA |
| StorageWorks Model 4314T, Ultra3,
Universal Drive Shelves Single Bus, Tower, International (190210-B31) |
DS-SL13T-AB
|
| StorageWorks Model 4314T, Ultra3,
Universal Drive Shelves Single Bus, Tower, Japan (190210-291) |
DS-SL13T-AJ |
| |
|
|
| StorageWorks
Universal Drive Shelves Model 4200 to Model 4300 Upgrade I/O Modules |
StorageWorks Model 4300 Ultra 160
single-port LVD I/O Module (190212-B21) |
DS-SE3ZJ-DA |
| StorageWorks Model 4300 Ultra 160
dual-port LVD I/O Module (190213-B21) |
DS-SE3ZJ-SA |
| |
|
|
System Disk Drives
(Supported in Model 4314R, 4314T, or 4354R Universal Drive Shelf) |
18.2-GB Ultra3 (LVD) 10,000 rpm
1-inch Universal drive |
3R-A0585-AA |
| 18.2-GB Ultra3 (LVD) 15,000 rpm
1-inch Universal drive |
3R-A1543-AA |
| 36.4-GB Ultra3 (LVD) 10,000 rpm
1-inch Universal drive |
3R-A0919-AA |
|
36.4-GB Ultra3 (LVD) 15,000 rpm
1-inch Universal drive |
3R-A3079-AA |
|
72.8-GB Ultra 3 (LVD) 10,000 rpm
1-inch Universal drive |
3R-A3050-AA |
|
18.2-GB U320 SCSI 15,000 rpm
1-inch Universal disk drive |
3R-A3848-AA |
|
36.4-GB U320 SCSI 10,000 rpm
1-inch Universal disk drive |
3R-A3838-AA |
|
36.4-GB U320 SCSI 15,000 rpm
1-inch Universal disk drive |
3R-A3849-AA |
|
72.8-GB U320 SCSI 10,000 rpm
1-inch Universal disk drive |
3R-A3839-AA |
|
72.8-GB U320 SCSI 15,000 rpm
1-inch Universal disk drive |
3R-A3851-AA |
|
146-GB U320 SCSI 10,000 rpm
1-inch Universal disk drive |
3R-A3841-AA |
| Step 7 -
UltraSCSI RAID Array Controllers & UltraSCSI RAID Packaged Solutions - Optional |
| Enterprise Virtual
Array Model 8C8D |
Enterprise Virtual
Array Model 8C8D 60-Hz, includes 42U opal storage cabinet, four M3220 controller assembly
with eight HSV110 controllers, eight M5214 dual FC loop 14-bay drive enclosures |
239782-001 |
|
Enterprise Virtual
Array Model 8C8D 50-Hz, includes 42U opal storage cabinet, four M3220 controller assembly
with eight HSV110 controllers, eight M5214 dual FC loop 14-bay drive enclosures |
249977-B21 |
| |
|
|
| Virtual Array 2CXX
and 8CXX |
Enterprise Virtual
Array Model 2C6D 60-Hz 42U opal storage cabinet, M3220 controller assembly with dual
HSV110 controllers, six M5214 dual FC loop 14-bay drive enclosures |
234345-B21 |
|
Enterprise Virtual
Array Model 2C6D -50-Hz 42U opal storage cabinet, M3220 controller assembly with dual
HSV110 controllers, six M5214 dual FC loop 14-bay drive enclosures |
234345-B22 |
|
Enterprise Virtual
Array Model 2C12D 60-Hz, includes 42U opal storage cabinet, M3220 controller assembly with
dual HSV110 controllers, 12 M5214 dual FC loop 14-bay drive enclosures |
234346-B21 |
|
Enterprise Virtual
Array Model 2C12D 60-Hz, includes 42U opal storage cabinet, M3220 controller assembly with
dual HSV110 controllers, 12 M5214 dual FC loop 14-bay drive enclosures |
234346-B22 |
|
Enterprise Virtual
Array Model 8C8D 60-Hz, includes 42U opal storage cabinet, four M3220 controller assembly
with eight HSV110 controllers, eight M5214 dual FC loop 14-bay drive enclosures |
239782-001 |
|
Enterprise Virtual
Array Model 8C8D 50-Hz, includes 42U opal storage cabinet, four M3220 controller assembly
with eight HSV110 controllers, eight M5214 dual FC loop 14-bay drive enclosures |
249977-B21 |
| |
|
|
| RAID Array 3000
Rackmount Controller Shelf |
- Selection of RA3000 Solutions Software Kit is required
|
- Supported SCSI adapter - 3X-KZPBA-CC PCI 1-port UltraSCSI
differential adapter
|
|
RA3000 rackmount controller
shelf, blue, with one controller, 110V
Includes: UltraSCSI BA356 controller shelf, one HSZ22 2-channel controller with
16-MB cache, integrated Environmental Monitoring Unit (EMU), two 180W power supplies, two
dual-port host differential UltraSCSI I/O SBBs, dual-channel UltraSCSI single-ended
personality modules, one 120V 1000VA rackmount UPS, 5-m host SCSI cable (BN37A-05),
BN38E-0B adapter, UPS serial cable, PC connection serial cable (DB-9), two 68-pin HD
tri-link adapters (H8861-AA), two North American power cords, and RETMA mounting bracket
(disk shelves and disks not included)
Requires: Solutions Software Kit for platform, host adapter, RA3000 disk shelf, and
disks
Options: Second HSZ22 controller, up to four additional RA3000 disk shelves, cache
memory upgrade |
DS-SWXRA-GH |
|
RA3000 rackmount controller
shelf, blue, with one controller, 230V
Includes: UltraSCSI BA356 controller shelf, one HSZ22 2-channel controller with
16-MB cache, integrated Environmental Monitoring Unit (EMU), two 180W power supplies, two
dual-port host differential UltraSCSI I/O SBBs, dual-channel UltraSCSI single-ended
personality modules, one 230V 1000VA rackmount UPS, 5-m host SCSI cable (BN37A-05),
BN38E-0B adapter, UPS serial cable, PC connection serial cable (DB-9), two 68-pin HD
tri-link adapters (H8861-AA), RETMA mounting bracket (disk shelves and disks not included)
Requires: Solutions Software Kit for platform, two country-specific power cords,
host adapter, RA3000 disk shelf, and disks
Options: Second HSZ22 controller, up to four additional RA3000 disk shelves, cache
memory upgrade |
DS-SWXRA-GK |
| |
| RAID Array 3000
Rackmount Disk Shelf |
- Select one to four disk shelves
|
- Third and fourth DS-SWXRA-GN disk shelf ordered will be installed in rear of M-Series
cabinet; rear mounted shelves require that a 2-meter BN37A-02 SCSI cable be ordered
|
|
RA3000 rackmount disk
shelf, blue, includes UltraSCSI BA356 disk shelf, two 180W
power supplies, single-ended UltraSCSI personality card, one half meter SCSI cable
(BN37A-0E), two North American power cords, and RETMA mounting bracket (disks not
included); order two country-specific power cords for non-North American use |
DS-SWXRA-GN |
| |
|
|
| HSZ22 Controller |
- Note that second HSZ22 controller ordered is field installed only, not factory
installed; requires BN37A-0E SCSI jumper cable be ordered separately
|
|
Second HSZ22
controller with 16-MB cache and two 16-MB SIMMs for mirror cache, one BN37A-05 5-meter
UltraSCSI cable, one BN38E-0B cable adapter - field installable
only; note that second HSZ22 controller does not require additional Solution Software Kit |
DS-HSZ22-AA |
|
Second HSZ22
controller with 32-MB cache and two 32-MB SIMMs for mirror cache, one BN37A-05 5-meter
UltraSCSI cable, one BN38E-0B cable adapter - field installed
only; note that second HSZ22 controller does not require additional Solution Software Kit |
DS-HSZ22-AB |
| |
|
|
| RA3000 Solutions Software Kit |
- StorageWorks Command Console (SWCC) software
|
|
- Platform specific software
|
|
- Installation scripts and installation documentation
|
|
RA3000 Solutions
Software Kit for Tru64 UNIX |
QB-5TWAB-SA |
|
RA3000 Solutions
Software Kit for OpenVMS |
QB-5TWAC-SA |
| |
|
|
| HSG80 External Controllers |
Fibre Channel
Controller (HSG80), includes 256-MB cache, requires following firmware:
8.6-4F ACS FW (222318-B22, QB-6BUAA-SD), one per controller
8.6-4S ACS FW (222364-B22, QB-6ENAA-SC), one per controller
8.6-4P ACS FW (222316-B22, QB-6CAAA-SD), one per controller
Requires Tru64 UNIX software: 222320-B23, QB-65RAB-SE, one per controller
Requires OpenVMS software: 222321-B22, QB-65RAC-SD, one per controller |
DS-HSG80-BK |
|
Additional 256-MB
cache for HSG80 (380674-B21) |
DS-HSDIM-AC |
|
Single cache battery,
one per HSG80 controller (135823-B21) |
DS-SE2CS-CB |
|
Model 2200 controller
shelf for HSG80 controller (DS-SE2ZS-C8) includes dual power supplies and power
cables |
135820-B21 |
| |
|
|
| RA3000 Pedestals |
RA3000 UltraSCSI
seven SBB slot pedestal cabinet, blue-gray, 230 volts, includes one DS-HSZ22-A controller,
16-MB cache, two host ports, two device ports, slot for second DS-HSZ22-AA, two redundant
power supplies 204 watts with fans, one BN37A-05 cable, one BN38E-0B adapter, one serial
cable, on UPS, two North American power cords |
DS-SWXRA-GC |
|
RA3000 UltraSCSI
seven SBB slot pedestal, blue-gray, 120/230 volts, includes two redundant power supplies
204 watts with fans, one BN37A-01 cable, two country power cords |
DS-SWXRA-GD |
| |
|
|
| ESA 10000, RAID Array 7000,
RAID Array 8000 |
- Enterprise Storage Array 10000 and RAID Array 7000 (HSZ70) product set are supported on
AlphaServer DS10 systems
|
|
- Supported SCSI adapter for HSZ80/HSZ70 - 3X-KZPBA-CC PCI
1-port UltraSCSI differential adapter
|
|
- Supported SCSI adapter for HSG80 - KGPSA-BC PCI 1-port
Fiber-Channel adapter
|
| |
| Step 8 -
Networks and Communications - Optional |
- Reference individual product information for operating system support.
|
|
- Systems include dual embedded 10/100 BaseT Ethernet ports (BN25G-xx cable must be
ordered separately)
|
|
- Additional Ethernet ports can be added using available PCI slots
|
|
| |
|
| |
Maximum #
Supported |
|
| |
Tru64 UNIX |
OpenVMS |
Linux-
Ready |
|
| Ethernet 10/100 |
|
|
|
|
PCI (32-bit, 33-MHz) single-port
10/100 Ethernet (UTP/RJ45) NIC
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
2 |
2 |
2 |
3X-DE600-AA |
PCI 2-port 10/100 Mb, Fast
Ethernet adapter, UTP, maximum one per system, maximum ten 10/100 Ethernet ports per
system.
NOTE: Two 10/100 Ethernet
ports included with DS10 system. |
1 |
1 |
1 |
3X-DE602-AA |
Single-port 100Mbps
(MMF/duplex-SC) add-on daughter card for use with
3X-DE602-BB. The combined 3X-DE602-BB 3X-DE602-FA provides two 10/100 (UTP/RJ45s) and one
100Mbps (MMF/SC) ports in a single PCI slot option. Maximum two per system, maximum
ten 10/100 Ethernet ports supported per system.
Use BN34A or BN34B cables.
NOTE: The 3X-DE602-TA cannot be used
standalone.
NOTE: Two 10/100 Ethernet ports included with DS10 system. |
2 |
2 |
- |
3X-DE602-FA |
PCI (32-/64-bit,
33-/66-MHz) dual-port 10/100 Ethernet (UTP/RJ45s) NIC and Base Module. (One 3X-DE602-TA or
3X-DE602-FA optional add-on daughter card can be combined with this module.) Maximum two
per system, maximum ten 10/100 Ethernet ports per system.
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
NOTE: Two 10/100 Ethernet ports
included with DS10 system. |
2 |
2 |
- |
3X-DE602-BB |
Dual-port 10/100 Ethernet
(UTP/RJ45) add-on daughter card for use with the 3X-DE602-BB only. The combined
3X-DE602-BB and 3X-DE602-TA modules provide four 10/100 (UTP/RJ45s) ports in a single PCI
slot option; allows for a maximum of 16 ports per system. Maximum two per system, maximum
ten 10/100 Ethernet ports per system.
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.NOTE: The 3X-DE602-TA cannot be used standalone.
- OpenVMS V7.3 requires Tima Kit:
- DEC-AXPVMS-VMS73_LAN-V01004.PCSI
- OpenVMS V7.2-2H1 requires OpenVMS Tima Kit located at:
- http://ftp.support.compaq.com/patches/.new/
openvms.shtml
NOTE: Two 10/100 Ethernet ports included with DS10 system. |
2 |
2 |
- |
3X-DE602-TA |
| PCI 10/100 Mb 4-port Ethernet
adapter, UTP |
1 |
1 |
1 |
DE504-BA |
| Cable for 10BaseT twisted pair
connection |
|
|
|
BN25G-xx |
| |
| PCI (32-/64-bit, 33-/66-MHz)
single-port 1000 Mbps (MMF/SC) NIC; no on-board boot-ROM support. Use BN34A or BN34B
cables. |
1 |
1 |
1 |
DEGPA-SA |
| |
| Multi-function
Ethernet 10/100 |
| PCI combo adapter, Permedia P2
graphics, 10/100 Mbit NIC |
1 |
1 |
1 |
3X-DEPVD-AA |
| PCI combo adapter, Permedia P2
graphics, 10/100 NIC, 1-port SCSI |
1 |
1 |
- |
3X-DEPVZ-AA |
| 3X-DEPVZ-AA specific-use 3-meter
LVD2 SCSI cable |
|
|
|
BN37A-03 |
| PCI-to-Gigabit Ethernet adapter
UTP, with RJ45 (no boot support) |
1 |
1 |
1 |
DEGPA-TA |
| |
| FDDI |
| PCI FDDI adapter, single
attachment station (SAS), multi-mode fiber (MMF), SC connector |
1 |
1 |
- |
3X-DEFPA-AC |
PCI (32-bit, 33-MHz) to FDDI DAS
(MMF/duplex-SC) NIC.
Use BN34A, BN34B, or BN34D cables. |
1 |
1 |
- |
3X-DEFPA-DC |
FDDI-specific cable - Multimode
fiber optic (MMF) 62.5/125um duplex cable with SC-to-MIC connectors.
-xx = available lengths: (01, 03, 10) for 1, 3, 10 meters |
|
|
|
BN34D-xx |
| SC-to-SC dual fiber optic cable
mm, pp xx = length in meters |
|
|
|
BN34B-xx |
| PCI (32-bit, 33-MHz) to FDDI SAS
(UTP/RJ45) NIC. Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
1 |
1 |
- |
3X-DEFPA-UC |
| PCI (32-bit, 33-MHz) to FDDI DAS
(UTP/RJ45s) NIC. Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
1 |
1 |
- |
3X-DEFPA-MC |
| |
| ATM |
PCI (32-bit, 33-MHz) to 155 Mbps
ATM, copper NIC with RJ45 connector.
Use BN25G-xx, or BN26M-xx cables. |
2
(V4.0F) |
2
(V7.2-1) |
- |
3X-DAPBA-UA
|
PCI (32-bit, 33-MHz) to 155 Mbps
ATM fiber NIC with SC connector.
Use BN34B-xx cable. |
2
(V4.0F) |
2
(V7.2-1) |
- |
3X-DAPBA-FA
|
PCI (32-bit, 33-MHz) to 622 Mbps
ATM fiber NIC with SC connector.
Use BN34B-xx cable. |
1
(V4.0F) |
2
(V7.2-1) |
- |
3X-DAPCA-FA |
| |
| Asynchronous
Communications (ASYNC) |
| PCI (32-bit, 33-MHz) to quad-port
Async Communications NIC with DB-25 octopus cable |
|
PBXDA-BA |
| PCI (32-bit, 33-MHz) to 8-port
Async Communications NIC with DB-25 octopus cables |
|
PBXDA-BB |
| PCI 16-port asynchronous
controller, cable included; maximum three PBXDA-Ax per system |
3
(V4.0F) |
3 |
- |
PBXDA-AC |
| PBXDA-AC
Asynchronous Connector Adapters |
| RJ45 to DB-25 converter cable |
|
CXI01-AC |
| RJ45 to DEC MJ11 converter cable
(8 pack) |
|
CXI01-AF |
| |
| Synchronous
Communications (SYNC) |
| PCI (32-bit, 33-MHz) to dual-port
intelligent synchronous communications NIC. Requires at least one (maximum two) BN34x
synchronous cable listed below. |
2 |
2 |
- |
3X-PBXDD-AA |
| PCI (32-bit, 33-MHz) to quad-port
intelligent synchronous communications NIC. Requires at least one (maximum four) BN34x
synchronous cable listed below. |
2 |
2 |
- |
3X-PBXDD-AB |
| |
| Synchronous-Specific
Cables |
| EIA-530 single-port cable |
|
3X-BC34G-06 |
| V.24/EIA-232 single-port cable |
|
3X-BC34L-06 |
| V.11/x.21 single-port cable |
|
3X-BC33S-06 |
| V.35 single-port cable |
|
3X-BC34T-06 |
| Ethernet, FDDI,
ATM Multi-use Cables |
Multimode fiber optic (MMF)
62.5/125um duplex cable, with SC-to-ST connectors.
xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, 30
meters |
|
BN34A-xx |
Multimode fiber optic (MMF)
62.5/125um duplex cable, with SC-to-SC connectors.
-xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, 30
meters |
|
BN34B-xx |
Category 5e (4-Unshielded Twisted
Pairs / UTP) straight-through cable with RJ45-to-RJ45 connectors for system to switch,
repeater, or hub connectivity.
-xx = available lengths: (0B, 0E, 01, 03, 04, 07) for 0.2, 0.5, 1, 3, 4, 7 meters |
|
BN25G-xx |
Category 5e (4-Twisted Pairs,
Screened/ ScTP) straight-through cable with RJ45-to-RJ45 connectors for system to switch,
repeater, or hub connectivity.
-xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, 7 meters |
|
BN26M-xx |
Category 5e (4-Unshielded Twisted
Pairs / UTP) Xover cable with RJ45-to-RJ45 connectors for system to switch, repeater, or
hub connectivity.
-xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, 7 meters |
|
BN24Q-xx |
Category 5e (4-Twisted Pairs,
Screened / ScTP) Xover cable with RJ45-to-RJ45 connectors for system to switch, repeater,
or hub connectivity.
-xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, 7 meters |
|
BN28Q-xx |
| |
| Step 9 - Graphics
Adapters - Optional |
- RAID Configuration Utility is accessible via console port for Tru64 UNIX and OpenVMS
systems; optional graphics capability available
|
- Select graphics adapter, monitor, and country-specific keyboard if required
Open3D license ships with PowerStorm 300/350 graphics
accelerators.
|
| |
Maximum #
Supported |
|
| |
Tru64 UNIX |
OpenVMS |
Linux-
Ready |
|
3Dlabs Oxygen VX1 32-MB PCI 2D
graphics accelerator.
NOTE: Only VX1 cards can be used
in a multihead environment. |
4 |
4 |
1 |
SN-PBXGF-AB |
| PowerStorm 300 3D multi-head
graphics accelerator with 15-MB frame buffer memory and 16-MB texture memory |
3 |
3 |
- |
SN-PBXGD-AD |
| PowerStorm 350 3D multi-head
graphics accelerator with 30-MB frame buffer memory and 32-MB texture memory |
3 |
3 |
- |
SN-PBXGD-AE |
| PCI combo adapter, Permedia P2
graphics, 10/100 Mbit NIC |
1 |
1 |
1 |
3X-DEPVD-AA |
| PCI combo adapter, Permedia P2
graphics, 10/100 NIC, 1-port SCSI |
1 |
1 |
- |
3X-DEPVZ-AA |
| |
|
| Step 10 -
Monitors - Optional |
- Graphics monitors other than those listed below can be used if compatible with SVGA
graphics ordered with system
|
|
- A video cable, 6-foot/1.8-meter length, is included with all variants of monitors
|
|
- Video extension cable required if monitor is located more than 1.5-meter from system
|
|
- Monitors ship with, but are not integrated with the system
|
|
| |
|
| Carbon/Silver Monitors |
V7550 17-inch (16-inch viewable
image size) flat-faced shadow mask color monitor, two-tone (carbon/silver), 0.25mm dot
pitch, VGA to 1024 x 768 @85 Hz, MPRII/TCO99/Energy Star compliant, Northern Hemisphere
with NA power cord, VGA cable |
3R-A4002-AA |
|
P720 17-inch (16-inch viewable
image size) auto-scanning color monitor, Diamondtron NF, 0.25-mm aperture grille pitch,
VGA to 1280 x 1024 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with
Euro power cord, VGA cable
NOTE: This variant can also be used for North
America and Asia Pacific. |
3R-A3389-AA
|
|
Same as above, APD, no power cord
(244373-B24) |
3R-A3390-AA |
|
Same as above, with PRC power
cord, CCIB (244373-AA1) |
3R-A3391-AA |
|
Same as above, Southern
Hemisphere, with Australia/New Zealand power cord (244373-011) |
3R-A3392-AA |
| |
|
|
|
P920 19-inch (18-inch viewable
image size) auto-scanning color monitor, Diamondtron NF, 0.24 mm aperture grille pitch,
VGA to 1600 x 1200 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA
power cord, VGA cable (244375-001) |
3R-A3393-AA
|
|
Same as above, with Euro power
cord (244375-021) |
3R-A3394-AA |
|
Same as above, with PRC power
cord, CCIB (244375-AA1) |
3R-A3396-AA |
|
Same as above, Southern
Hemisphere, 0.25 to 0.27 mm aperture grille pitch, with Australia/New Zealand power cord
(244375-011) |
3R-A3397-AA
|
| |
|
|
|
P1220 22-inch (20-inch viewable
image size) auto-scanning color monitor, Diamondtron NF, 0.24 mm aperture grille pitch,
VGA to 1792 x 1344 @85Hz, dual video input, USB Hub, MPRII/TCO 99/Energy Star Compliant,
Northern Hemisphere with NA power cord, VGA cable (244374-001) |
3R-A3398-AA
|
|
Same as above, with Euro power
cord (244374-021) |
3R-A3399-AA |
|
Same as above, APD, no power cord
(244374-B24) |
3R-A3400-AA |
|
Same as above, with PRC power
cord, CCIB (244374-AA1) |
3R-A3401-AA |
|
Same as above, Southern
Hemisphere, with Australia/New Zealand power cord (244374-011) |
3R-A3402-AA
|
| |
| Carbon/Silver Flat Panel
Monitors |
TFT1825, 18-inch (18-inchviewable
image size) TFT flat panel monitor, 0.28mm pixel pitch, 1600 x 1200 @60Hz, multi-mode
support, MPRII/TCO99/Energy Star compliant, one VGA, one DVI-I input connector. NA power
cord, VGA and DVI-I cables |
3R-A4292-AA |
|
TFT1520, 15.1-inch (15-inch
viewable image size) TFT flat panel monitor, 0.297 mm pixel pitch, 1024 x 768 @75 Hz,
multi-mode support, MPRII/TCO99/Energy Star compliant, two video input connectors (one VGA
and one DVI-I), NA power cord, VGA and DVI-I cables |
3R-A4249-AA |
| |
|
|
| Video Extension Cable |
6-foot/1.8-meter video extension
cable |
BN39C-02 |
| |
|
|
| Monitor Power Cords |
North America |
BN26J-1K |
|
Australia, New Zealand, 2.5-meter
(103541-011) |
BN19H-2E |
|
Central Europe, 2.5-meter |
BN19C-2E |
|
Denmark, 2.5-meter (103541-481) |
BN19K-2E |
|
Egypt, India, South Africa,
2.5-meter (103541-AR1) |
BN19S-2E |
|
Israel, 2.5-meter |
BN18L-2E |
|
Italy, 2.5-meter (103541-461) |
BN35M-02 |
|
Japan, 2.5-meter, Dentori
approved |
3X-BN46F-02 |
|
Switzerland, 2.5-meter
(103541-511) |
BN19E-2E |
|
UK, Ireland, 2.5-meter |
BN19A-2E |
| |
| Step 11 -
Keyboards, Mouse |
- Keyboards are not included with the system and must be ordered separately
|
|
- Selection of country-specific keyboard is recommended
|
|
- Select an opal OpenVMS keyboard for use with VT5xx text terminals.
|
|
| |
Opal |
Carbon |
| Keyboard/Language |
OpenVMS |
Tru64 UNIX |
OpenVMS |
| U.S. keyboard |
LK461-A2 |
3R-LKQ48-BA |
3X-LK462-A2 |
| Arabic keyboard |
- |
3R-LKQ48-BR |
- |
| Belgian keyboard |
LK461-AB |
3R-LKQ48-AB |
3X-LK462-AB |
| BHCSY keyboard |
- |
3R-LKQ48-AX |
- |
| Canadian/English keyboard |
LK461-AQ |
- |
3X-LK462-AQ |
| Canadian/French keyboard |
LK461-AC |
3R-LKQ48-AC |
3X-LK462-AC |
| Cyrillic keyboard (Russian) |
LK461-BT |
3R-LKQ48-BT |
3X-LK462-BT |
| Czech keyboard |
LK461-BV |
3R-LKQ48-BV |
3X-LK462-BV |
| Danish keyboard |
LK461-AD |
3R-LKQ48-AD |
3X-LK462-AD |
| Dutch keyboard |
LK461-AH |
3R-LKQ48-AH |
3X-LK462-AH |
| Finnish keyboard |
LK461-AF |
3R-LKQ48-AF |
3X-LK462-AF |
| French keyboard |
LK461-AP |
3R-LKQ48-AP |
3X-LK462-AP |
| German keyboard |
LK461-AG |
3R-LKQ48-AG |
3X-LK462-AG |
| Greek keyboard |
LK461-BH |
3R-LKQ48-BH |
3X-LK462-BH |
| Hebrew keyboard |
LK461-AT |
3R-LKQ48-AT |
3X-LK462-AT |
| Hungarian keyboard |
LK461-BQ |
3R-LKQ48-BQ |
3X-LK462-BQ |
| International keyboard |
- |
3R-LKQ48-BA |
- |
| Italian keyboard |
LK461-AI |
3R-LKQ48-AI |
3X-LK462-AI |
| Japanese keyboard |
- |
3R-LKQ48-AJ |
- |
| Korean keyboard |
- |
3R-LKQ48-BK |
- |
| Latin-American keyboard |
- |
3R-LKQ48-AR |
- |
| Norwegian keyboard |
LK461-AN |
3R-LKQ48-AN |
3X-LK462-AN |
| Polish keyboard |
LK461-BP |
3R-LKQ48-BP |
3X-LK462-BP |
| Portuguese keyboard |
LK461-AV |
3R-LKQ48-AV |
3X-LK462-AV |
| Romanian keyboard |
LK461-BL |
- |
3X-LK462-BL |
| Simplified Chinese keyboard |
- |
3R-LKQ48-CV |
- |
| Slovak keyboard |
LK461-CZ |
3R-LKQ48-CZ |
3X-LK462-CZ |
| Spanish keyboard |
LK461-AS |
3R-LKQ48-AS |
3X-LK462-AS |
| Swedish keyboard |
LK461-AM |
3R-LKQ48-AM |
3X-LK462-AM |
| Swiss/French keyboard |
LK461-AK |
3R-LKQ48-AK |
3X-LK462-AK |
| Swiss/German keyboard |
LK461-AL |
- |
3X-LK462-AL |
| Traditional Chinese keyboard |
- |
3R-LKQ48-BI |
- |
| Thai keyboard |
- |
3R-LKQ48-CB |
- |
| Turkish Q keyboard |
LK461-BU |
3R-LKQ48-BU |
3X-LK462-BU |
| Turkish/F keyboard |
LK461-BW |
- |
3X-LK462-BW |
| UK keyboard |
- |
3R-LKQ48-AE |
- |
| Yugoslavian keyboard |
LK461-BY |
- |
3X-LK462-BY |
| |
| Mouse Recommended |
|
3-button mouse
carbon |
3R-A3480-AA |
| |
|
|
| Step
12 - Console Terminal - Optional |
|
- Any terminal can be used as a console device
|
|
|
- Third-party console devices require an EIA-232 25-pin DSUB connector
|
|
|
VT510 video terminal; requires
H8575-x cable, either male or female |
VT510-xx |
|
Console cable, female connector |
H8575-A |
|
Console cable, male connector |
H8575-D |
|
Console cable, male connector
(IBM compatible) |
H8575-E |
| |
|
|
| Step
13- MEMORY CHANNEL - Optional |
| Tru64 UNIX Systems |
- Requires Tru64 UNIX V5.0A or later and either TruCluster Server license
(QL-6BRAC-AA) or TruCluster Plus Software Package (QP-6R9AC-AA)
|
|
| |
|
|
| OpenVMS Systems |
- Requires OpenVMS V7.1-2 or later and OpenVMS Cluster license
(QL-MUZAC-AA)
|
|
| |
|
|
| Configuring Information |
- Up to two PCI-to-System Area Network adapters (CCMAB-AA) are supported in a single
system.
|
|
|
- Two-node clusters can be configured by ordering a CCMAB-AA for each node and one
BN39B-04 or BN39B-10 cable; cable connects directly to CCMAB-AA in each node.
- For a two-node cluster that will not need to be rebooted when adding additional members,
order one CCMAB-AA adapter and one BN39B-04 or BN39B-10 cable for each node, and one
CCMHB-AA hub for the cluster.
- For three- or four- node clusters, order one CCMAB-AA adapter and one
BN39B-04 or BN39B-10 cable for each node, and one CCMHB-AA hub for the cluster
|
|
|
- CCMHB-AA includes four CCMLB-AA line cards and supports up to four nodes; expansion up
to eight system nodes can be achieved by adding up to four CCMLB-AA line cards.
|
|
|
- If two CCMAB-AAs are configured in each system, a second CCMHB-AA is required.
|
|
|
- If nodes must be separated by a distance longer than standard copper cables allow the
CCMFB option converts the output of the standard CCMAB controller or CCMLB line card to
single-mode fiber optic cable. The fiber optic connection may be up to 2,000 meters long
between two CCMAB controllers connected in virtual hub mode, or 3,000 meters between a
CCMAB controller and a CCMHB hub. (The connection from the CCMHB hub to a second system
may also be 3,000 meters.) The CCMFB option requires a second PCI slot in the system from
which it draws power only. It is normally connected to the corresponding CCMAB controller
with the short BN39B-01 cable. The CCMFB is also used in the CCMHB hub where it occupies a
slot normally used by the CCMLB line card, limiting expansion to four radial fiber optic
connections.
|
|
|
- CCMHB-BA hub expansion box provides additional slots for up to eight fiber optic
connections. Two standard length single-mode fiber optic cables are available (BN34R-10
and BN34R-31); however, users normally provide this fiber optic connection. Fiber optic
connectivity is completely transparent to the systems using it and has no performance
impact.
|
|
|
- For integration of MEMORY CHANNEL hubs into cabinet configurations, a rackmount kit
(2T-MAVRK-AA) and power cord (BN35S-02) are required
|
|
| |
| MEMORY CHANNEL Controller |
PCI System Area
Network Controller, maximum two |
CCMAB-AA |
|
System Area Network
Hub with four line cards; includes BN19P-2E power cord for Canada, Japan, and U.S.
operations- for other regions, order appropriate power cord
from list below |
CCMHB-AA |
|
Hub expansion box
with no line cards |
CCMHB-BA |
|
Expansion line card
for CCMHB hub |
CCMLB-AA |
|
1-meter cable for
CCMAB and CCMHB |
BN39B-01 |
|
4-meter cable for
CCMAB and CCMHB |
BN39B-04 |
|
10-meter cable for
CCMAB and CCMHB |
BN39B-10 |
|
Copper-to-single mode
fiber optic converter - 5V (clock not affected) |
CCMFB-AA |
|
Rackmount kit for
CCMHB hub |
2T-MAVRK-AA |
|
Power cord for
rackmount CCMHB hub |
BN35S-02 |
| |
|
|
| MEMORY CHANNEL Power Cords |
Australia, New Zealand
(103541-011) |
BN19H-2E |
|
Central Europe |
BN19C-2E |
|
Denmark (103541-481) |
BN19K-2E |
|
Egypt, India (103541-AR1) |
BN19S-2E |
|
Ireland, United Kingdom |
BN19A-2E |
|
Israel |
BN18L-2E |
|
Italy (103541-461) |
BN35M-02 |
|
Switzerland (103541-511) |
BN19E-2E |
| |
| Step 14 -
Floor Stand |
|
Floor Stand for
AlphaServer/AlphaStation DS10 |
3X-BA73P-AA |
| |
|
|
| Step 15 -
Software - Required selection of media and documentation for first system on site |
|
- Software processor code = E
|
|
| |
|
|
| Tru64 UNIX |
- AlphaServer DS10Tru64 UNIX systems include Base license, Unlimited User license, Server
Extension license, Internet Express, and Compaq Secure Web Server
|
|
|
- AlphaStation DS10 Tru64 UNIX systems include 2-user Base license
|
|
| |
|
|
| When using Tru64
UNIX V5.0A or later |
Tru64 UNIX media and online
documentation on CD-ROM |
QA-6ADAA-H8 |
| Tru64 UNIX full hard copy
documentation |
QA-6ADAA-GZ |
|
TruCluster Plus Software Package
with licenses for TruCluster Server, Logical Storage Manager, and AdvFS Utilities |
QP-6R9AC-AA |
|
TruCluster Server License |
QL-6BRAC-AA |
|
AdvFS Utilities License |
QL-0EGAE-AA |
|
Logical Storage Manager License |
QL-2GVAE-AA |
|
Advanced Server for Tru64 UNIX,
25 client concurrent use license |
QL-5U29M-3D |
|
Advanced Server for Tru64 UNIX,
50 client concurrent use license |
QL-5U29M-3E |
|
Advanced Server for Tru64 UNIX,
100 client concurrent use license |
QL-5U29M-3F |
|
Advanced Server for Tru64 UNIX,
250 client concurrent use license |
QL-5U29M-3G |
|
Advanced Server for Tru64 UNIX,
500 client concurrent use license |
QL-5U29M-3H |
|
Layered products media and
documentation for Tru64 UNIX on CD-ROM |
QA-054AA-H8 |
|
DECnet/OSI end-system license for
Tru64 UNIX |
QL-MTJAE-AA |
|
DECnet/OSI extended function
license for Tru64 UNIX |
QL-MTKAE-AA |
| |
| OpenVMS |
- AlphaServer DS10 OpenVMS systems include Base license with System Manager license and
Compaq Enterprise Integration Server License Package for OpenVMS Revision V3.0A.
|
|
|
- AlphaStation DS10 OpenVMS systems include Base license, Concurrent Use
1-user license, and NAS 150 Client license.
|
|
|
- Compaq Enterprise Integration Package includes licenses for TCP/IP Services for OpenVMS,
DECwindows Motif for OpenVMS Alpha, DECprint Supervisor for OpenVMS Alpha Plus, DECprint
Supervisor for OpenVMS Open, DECnet-Plus for OpenVMS Alpha End System, Archive/Backup
System for OpenVMS Management Tools, Archive/Backup Agent for Windows NT, OpenVMS Disk
Services for Windows NT, Office Server for OpenVMS, PATHWORKS 32, PATHWORKS V6 for OpenVMS
Advanced Server, and DIGITAL Office Server Client Access License
|
|
|
OpenVMS V7.1-2 media and online
documentation on CD-ROM |
QA-MT1AR-H8 |
|
OpenVMS V7.2-1 media and online
documentation on CD-ROM |
QA-MT1AT-H8 |
|
OpenVMS media and online
documentation on CD-ROM |
QA-MT1AA-H8 |
|
OpenVMS hard copy documentation |
QA-001AA-GZ |
|
Layered products media and
documentation for OpenVMS on CD-ROM |
QA-03XAA-H8 |
|
Open3D for OpenVMS on CD-ROM,
includes graphics drivers |
QA-0ADAA-H8 |
|
- OpenVMS Concurrent Use licenses provide the right to interactively use the operating
system by the specified number of concurrent users on a designated OpenVMS system. OpenVMS
Concurrent Use licenses can be moved from one system to another at user discretion and can
be shared in a mixed OpenVMS VAX and OpenVMS Alpha cluster.
|
|
|
- OpenVMS Traditional Unlimited Use license is system specific and can only be used on one
single system at a time. It cannot be shared between systems or in an OpenVMS VAX or
OpenVMS Alpha Cluster.
|
|
|
Concurrent Use 1-user license |
QL-MT3AA-3B |
|
Concurrent Use 2-user license |
QL-MT3AA-3C |
|
Concurrent Use 4-user license |
QL-MT3AA-3D |
|
Concurrent Use 8-user license |
QL-MT3AA-3E |
|
Concurrent Use 16-user license |
QL-MT3AA-3F |
|
Concurrent Use 32-user license |
QL-MT3AA-3G |
|
Concurrent Use 64-user license |
QL-MT3AA-3H |
|
Concurrent Use 128-user license |
QL-MT3AA-3J |
|
Concurrent Use 256-user license |
QL-MT3AA-3K |
|
Traditional Unlimited User
license |
QL-MT2AE-AA |
|
OpenVMS Cluster license for Alpha
systems |
QL-MUZAC-AA |
|
OpenVMS Cluster Client license
for Alpha systems |
QL-3MRAC-AA |
|
OpenVMS Cluster Client-to-Full
OpenVMS Cluster Migration license |
QL-6J7AC-AA |
| |
|
|
| Linux Kit -
Optional |
Linux Red Hat CD-ROM Kit |
QA-6M1AA-H8 |
| |
| Step 16 -
Hardware and Software Support Services |
- Select one of the optional CarePaq Priority Service Packages described
below that best supports the customers operational requirements for system
availability.
|
|
| |
|
| CarePaq Priority Services |
- CarePaq Priority Services are available for AlphaServer/AlphaStation systems running
Tru64 UNIX or OpenVMS operating systems. Priority Services are designed for the growing
number of customers who need support beyond the basic warranty. Five packages are offered
- Priority, Priority 24, Priority Silver, Priority Gold, and Priority Executive with
coverage for both Principal servers/stations and SSPs (Subsequent System Packages) - that meet a full range of customer support requirements.
|
|
| |
|
|
| Program Features
Principal Server/Station |
|
| Priority |
|
9 x 5 HW/SW support |
|
|
|
4-hour response on-site hardware
support |
|
|
|
2-hour response for Bronze
software support |
|
|
|
License Subscription for Compaq
O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server
extensions for Tru64 UNIX) |
|
|
|
Condist update distribution for
OpenVMS or Tru64 UNIX and their layered products. (Layered products not included on
Condist can be ordered separately.) |
|
| |
|
|
| Priority 24 |
|
24 x 7 HW/SW support |
|
|
|
Named HW engineer |
|
|
|
4-hour response on-site hardware
support |
|
|
|
2-hour response for Bronze
software support |
|
|
|
License Subscription for Compaq
O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server
extensions for Tru64 UNIX) |
|
|
|
Condist update distribution for
OpenVMS or Tru64 UNIX and their layered products. (Layered products not included on
Condist can be ordered separately.) |
|
| |
|
|
|
| Priority Silver |
|
24 x 7 HW Support with Named
Engineer, 4-hour response |
|
|
|
24 x 7 Silver SW Support - Named
Account Rep, 1-hour response Monday Friday, 8AM-5PM local time; 2-hour response
remaining hours |
|
|
|
License Subscription for Compaq
O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server
extensions for Tru64 UNIX) |
|
|
|
Condist update distribution for
OpenVMS or Tru64 UNIX and their layered products. (Layered products not included on
Condist can be ordered separately.) |
|
|
|
Technical newsletter and SW
activity review |
|
|
|
Proactive Patch Notification |
|
|
|
One (1) System Healthcheck per
year |
|
| |
|
|
|
| Priority Gold |
|
24 x 7 HW support with Named
Engineer, 4-hour response for on-site support |
|
|
|
24 x 7 Gold SW support - Named
Account Rep |
|
|
|
30-minute callback (critical);
1-hour callback (non-critical) |
|
|
|
License Subscription for Compaq
O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server
extensions for Tru64 UNIX) |
|
|
|
Condist update distribution for
OpenVMS or Tru64 UNIX and their layered products. (Layered products not included on
Condist can be ordered separately.) |
|
|
|
Technical newsletter, SW activity
review and 10 hours Upgrade impact planning |
|
|
|
Proactive Revision Management |
|
|
|
Two (2) System Healthchecks per
year |
|
|
|
Mandatory pre-qualification
required |
|
| |
| Priority Gold Executive |
|
24 x 7 HW support with Named
Engineer, two-hour response for on-site support |
|
|
|
24 x 7 Gold SW support - Named
Account Rep |
|
|
|
30-minute callback (critical);
one-hour callback (non-critical) |
|
|
|
License Subscription for Compaq
O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server
extensions for Tru64 UNIX) |
|
|
|
Software update distribution on
CD-ROM: OpenVMS or Tru64 UNIX and their layered products (Layered products not included on
Condist can be ordered separately.) |
|
|
|
Technical newsletter, SW activity
review and 10 hours Upgrade impact planning |
|
|
|
Proactive Revision Management |
|
|
|
Two (2) System Healthchecks per
year |
|
|
|
Customer site must be within 25
miles of a Compaq service location |
|
|
|
Mandatory pre-qualification
required |
|
| |
|
|
| Program Features
Additional Services |
|
SSPs
(Subsequent System Packages) |
|
For Priority, Priority 24,
Priority Silver, Priority Gold, and Priority Gold Executive |
|
|
HW Support at same level as
corresponding package for Principal server/station |
|
|
|
License Subscription: Compaq O/S
(where applicable) |
|
|
|
Telephone support through
Principal server/station covered by full support package |
|
|
|
|
|
| Installation |
|
Pre-installation review |
|
|
|
Unpacking of equipment |
|
|
|
Assemble and test |
|
|
|
Basic product usage info |
|
|
|
No software installation added |
|
|
|
|
|
| Installation &
Startup Compaq O/S |
|
Pre-installation review |
|
|
Unpacking of equipment |
|
|
|
Assemble and test |
|
|
|
Basic product usage info |
|
|
|
Install operating systems |
|
|
|
Product configuration |
|
|
|
Print and network access |
|
|
|
Orientation |
|
| |
Model/CarePaq
Priority Service |
Principal
Server/Station
1 year |
Principal
Server/Station
3 years |
Subsequent Systems
1 year |
Subsequent Systems
3 years |
| AlphaServer/AlphaStation
DS10 |
|
|
|
| Priority |
FP-A01BA-12 |
FP-A01BA-36 |
FP-A21BA-12 |
FP-A21BA-36 |
| Priority 24 |
FP-A02BA -12 |
FP-A02BA-36 |
FP-A22BA-12 |
FP-A22BA-36 |
| Priority Silver |
FP-A04BA-12 |
FP-A04BA-36 |
FP-A24BA-12 |
FP-A24BA-36 |
| Priority Gold |
FP-A08BA-12 |
FP-A08BA-36 |
FP-A28BA-12 |
FP-A28BA-36 |
| Priority Gold Exec. |
FP-A09BA-12 |
FP-A09BA-36 |
FP-A29BA-12 |
FP-A29BA-36 |
| Installation |
FP-AINST-BA |
FP-AINST-BA |
FP-AINST-BA |
FP-AINST-BA |
| Priority |
FP-A01BA-12 |
FP-A01BA-36 |
FP-A21BA-12 |
FP-A21BA-36 |
| Installation &
Startup |
FP-ASTAR-BA |
FP-ASTAR-BA |
FP-ASTAR-BA |
FP-ASTAR-BA |
| |
NOTES:
- AlphaServer/AlphaStation DS10 systems include three years hardware warranty with 5x9,
on-site Next Business Day response.
- New Compaq hardware options internal to the AlphaServer/AlphaStation enclosure receive
the same warranty or service level as purchased with the server or station.
- External storage devices/cabinets carry their own level of warranty and should be quoted
separately for uplifted warranty services (CarePaq Priority Service).
- In addition to the CarePaq Priority Services, uplifted warranty Supplemental Services
are available for separate hardware and software support. For more information on Hardware
and Software Supplemental Services and other service options available for AlphaServers
and AlphaStations, consult your Sales Account Manager or visit
http://www.compaq.com/services/
NOTE: This website is available
in English only.
|
| |
|